Non-Metalic Wire?
I saw this and was wondering how long it has been around and how does it
work. What is it made out of to deliver electricity? https://www.lowesforpros.com/pd/Sout...e-Roll/1193433 What am I missing? Are they actually talking about the casing? The casing is not wire... |
#2
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On 3/8/19 11:03 AM, Leon wrote:
I saw this and was wondering how long it has been around and how does it work.Â* What is it made out of to deliver electricity? https://www.lowesforpros.com/pd/Sout...e-Roll/1193433 What am I missing?Â* Are they actually talking about the casing?Â* The casing is not wire... I believe the Non-Metallic (NM) means the sheathing is made of plastic, not metal. There are times when it's required to have metal-sheathed wire and times when you can use Romex, non-metallic sheathed wire. So that's the designation. MC for metal clad, and NM for non-metallic. -- -MIKE- "Playing is not something I do at night, it's my function in life" --Elvin Jones (1927-2004) -- www.mikedrums.com |
#3
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On Fri, 8 Mar 2019 11:03:11 -0600, Leon lcb11211@swbelldotnet wrote:
I saw this and was wondering how long it has been around and how does it work. What is it made out of to deliver electricity? https://www.lowesforpros.com/pd/Sout...e-Roll/1193433 What am I missing? Are they actually talking about the casing? The casing is not wire... The product category is under " non metallic jacket wire " shortened to " non metallic wire " in the product page - just to confuse people .. John T. |
#4
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
Leon lcb11211@swbelldotnet writes:
I saw this and was wondering how long it has been around and how does it work. What is it made out of to deliver electricity? https://www.lowesforpros.com/pd/Sout...e-Roll/1193433 What am I missing? Are they actually talking about the casing? The casing is not wire... NM is the typical NEC abbreviation for Romex(brand)-style cabling. |
#5
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On Friday, March 8, 2019 at 12:03:28 PM UTC-5, Leon wrote:
I saw this and was wondering how long it has been around and how does it work. What is it made out of to deliver electricity? https://www.lowesforpros.com/pd/Sout...e-Roll/1193433 What am I missing? Are they actually talking about the casing? The casing is not wire... See he https://www.doityourself.com/stry/nm...-armored-cable |
#6
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On 3/8/2019 11:12 AM, -MIKE- wrote:
On 3/8/19 11:03 AM, Leon wrote: I saw this and was wondering how long it has been around and how does it work.Â* What is it made out of to deliver electricity? https://www.lowesforpros.com/pd/Sout...e-Roll/1193433 What am I missing?Â* Are they actually talking about the casing?Â* The casing is not wire... I believe the Non-Metallic (NM) means the sheathing is made of plastic, not metal. There are times when it's required to have metal-sheathed wire and times when you can use Romex, non-metallic sheathed wire. So that's the designation.Â* MC for metal clad, and NM for non-metallic. Understood but it specifically says non metallic "wire". And I do not ever recall Romex ever being called metallic or non metallic. Probably another situation where those persons naming parts or describing something have no idea what the meaning of words are. Functionality, never needed to replace the word function. And for that matter, "almost any word that has had "ality" added in the last 10~12 years. Utilize, never needed to replace the word use. And while I am on the soap box, When did the word button start being pronounced but-in. Garden, now pronounced gar-din. Classic example of school no longer teaching students how to read the dictionary. All future left voters. |
#8
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On Friday, March 8, 2019 at 1:25:44 PM UTC-5, Leon wrote:
On 3/8/2019 11:12 AM, -MIKE- wrote: On 3/8/19 11:03 AM, Leon wrote: I saw this and was wondering how long it has been around and how does it work.Â* What is it made out of to deliver electricity? https://www.lowesforpros.com/pd/Sout...e-Roll/1193433 What am I missing?Â* Are they actually talking about the casing?Â* The casing is not wire... I believe the Non-Metallic (NM) means the sheathing is made of plastic, not metal. There are times when it's required to have metal-sheathed wire and times when you can use Romex, non-metallic sheathed wire. So that's the designation.Â* MC for metal clad, and NM for non-metallic. Understood but it specifically says non metallic "wire". And I do not ever recall Romex ever being called metallic or non metallic. It's not uncommon, assuming that you accept that by referring to something by using the initials NM, it is being referred to as non-metallic. https://www.thespruce.com/what-does-...m-mean-1821530 "Romex® is the specific brand name for a non-metallic (NM) building wire made by Southwire. In other words, Romex® is technically just one brand of NM cable. However, the term Romex is often used generically (though inaccurately) to describe any type of NM cable, no matter which manufacturer made it." |
#9
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On Friday, March 8, 2019 at 11:03:28 AM UTC-6, Leon wrote:
I saw this and was wondering how long it has been around and how does it work. What is it made out of to deliver electricity? https://www.lowesforpros.com/pd/Sout...e-Roll/1193433 What am I missing? Are they actually talking about the casing? The casing is not wire... Under description " Copper conductors are annealed (soft) copper " |
#10
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On Friday, March 8, 2019 at 1:25:44 PM UTC-5, Leon wrote:
On 3/8/2019 11:12 AM, -MIKE- wrote: On 3/8/19 11:03 AM, Leon wrote: I saw this and was wondering how long it has been around and how does it work.Â* What is it made out of to deliver electricity? https://www.lowesforpros.com/pd/Sout...e-Roll/1193433 What am I missing?Â* Are they actually talking about the casing?Â* The casing is not wire... I believe the Non-Metallic (NM) means the sheathing is made of plastic, not metal. There are times when it's required to have metal-sheathed wire and times when you can use Romex, non-metallic sheathed wire. So that's the designation.Â* MC for metal clad, and NM for non-metallic. Understood but it specifically says non metallic "wire". And I do not ever recall Romex ever being called metallic or non metallic. Interesting story (at least to me) about NM wire. I'm sure that most of us are familiar with the "cloth covered" NM wiring in older homes. You know, same concept as Romex, except that all the sheathing is cloth, not plastic. Well... My godparents lived on Narragansett Blvd in Chicopee MA. (be sure to remember the name of that street) Their house was where I learned about knob-and-tube wiring as a teenager. I helped my godfather pull some new wires through the K&T fixtures. It was my first experience with house wiring. Fast forward a decade or so when I was about to buy my first house, a house located in western NY. While visiting my godparents they handed me a wad of cash to help with the down-payment. So, I move in and I'm getting ready to do some wiring work on my own house. A house that some nice folks that lived on Narragansett Blvd helped me buy. Narragansett Blvd, where I had my very first experience with house wiring. Imagine my surprise when I looked at the cloth covered NM wiring and noticed the name "Narragansett Wire Company" printed on the sheathing! That was a very spooky feeling! |
#11
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
I saw this and was wondering how long it has been around and how does it work. What is it made out of to deliver electricity? https://www.lowesforpros.com/pd/Sout...e-Roll/1193433 What am I missing? Are they actually talking about the casing? The casing is not wire... The product category is " non metallic jacket wire" shortened to " non metallic wire " in the product page. John T. Yeah, another example would be 2x4. .. if you say so ? John T. |
#12
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On Fri, 8 Mar 2019 11:03:11 -0600, Leon lcb11211@swbelldotnet wrote:
I saw this and was wondering how long it has been around and how does it work. What is it made out of to deliver electricity? https://www.lowesforpros.com/pd/Sout...e-Roll/1193433 What am I missing? Are they actually talking about the casing? The casing is not wire... Yes it is still a copper conductor, it is the sheathing compared to armored cable which the description is also confuusing because it say aluminum and the conductors are copper. |
#13
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On Fri, 8 Mar 2019 12:25:28 -0600, Leon lcb11211@swbelldotnet wrote:
On 3/8/2019 11:12 AM, -MIKE- wrote: On 3/8/19 11:03 AM, Leon wrote: I saw this and was wondering how long it has been around and how does it work.* What is it made out of to deliver electricity? https://www.lowesforpros.com/pd/Sout...e-Roll/1193433 What am I missing?* Are they actually talking about the casing?* The casing is not wire... I believe the Non-Metallic (NM) means the sheathing is made of plastic, not metal. There are times when it's required to have metal-sheathed wire and times when you can use Romex, non-metallic sheathed wire. So that's the designation.* MC for metal clad, and NM for non-metallic. Understood but it specifically says non metallic "wire". And I do not ever recall Romex ever being called metallic or non metallic. Probably another situation where those persons naming parts or describing something have no idea what the meaning of words are. Functionality, never needed to replace the word function. And for that matter, "almost any word that has had "ality" added in the last 10~12 years. Utilize, never needed to replace the word use. And while I am on the soap box, When did the word button start being pronounced but-in. Garden, now pronounced gar-din. Classic example of school no longer teaching students how to read the dictionary. All future left voters. Another word peeve with = wid? |
#14
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
Markem writes:
On Fri, 8 Mar 2019 12:25:28 -0600, Leon lcb11211@swbelldotnet wrote: And while I am on the soap box, When did the word button start being pronounced but-in. Garden, now pronounced gar-din. Classic example of school no longer teaching students how to read the dictionary. Classic example of geographical variation, y'all. |
#15
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On Fri, 08 Mar 2019 12:27:15 -0600, Leon wrote:
Yeah, another example would be 2x4. In my carpenter apprentice classes, it's neither 2 nor 4 but 38 x 89. Shocked me to learn that the blade of my skill saw is 89mm from the edge of the sole plate: it's been aqn inch and a half since Pontius was a pilot. |
#16
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On 3/8/2019 11:03 AM, Leon wrote:
I saw this and was wondering how long it has been around and how does it work. What is it made out of to deliver electricity? https://www.lowesforpros.com/pd/Sout...e-Roll/1193433 What am I missing?Â* Are they actually talking about the casing?Â* The casing is not wire... Apparently they are talking about the casing. Down at the bottom of the page they say Copper conductors are annealed (soft) copper. Poorly written ad. Can anyone here name a non-metallic material that a good conductor of electricity? Who educates these people? |
#17
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On Fri, 8 Mar 2019 11:03:11 -0600, Leon lcb11211@swbelldotnet wrote:
I saw this and was wondering how long it has been around and how does it work. What is it made out of to deliver electricity? https://www.lowesforpros.com/pd/Sout...e-Roll/1193433 What am I missing? Are they actually talking about the casing? The casing is not wire... It is non metallic sheathed cable by definiution - has copper conductors. What do you expect af a big box store's description of technical products??? |
#18
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
gray_wolf wrote:
Can anyone here name a non-metallic material that a good conductor of electricity? Graphite https://www.youtube.com/embed/s9eE2jFoioM?autoplay=1&rel=0 |
#19
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On Fri, 8 Mar 2019 12:25:28 -0600, Leon lcb11211@swbelldotnet wrote:
On 3/8/2019 11:12 AM, -MIKE- wrote: On 3/8/19 11:03 AM, Leon wrote: I saw this and was wondering how long it has been around and how does it work.* What is it made out of to deliver electricity? https://www.lowesforpros.com/pd/Sout...e-Roll/1193433 What am I missing?* Are they actually talking about the casing?* The casing is not wire... I believe the Non-Metallic (NM) means the sheathing is made of plastic, not metal. There are times when it's required to have metal-sheathed wire and times when you can use Romex, non-metallic sheathed wire. So that's the designation.* MC for metal clad, and NM for non-metallic. Understood but it specifically says non metallic "wire". And I do not ever recall Romex ever being called metallic or non metallic. Probably another situation where those persons naming parts or describing something have no idea what the meaning of words are. Functionality, never needed to replace the word function. And for that matter, "almost any word that has had "ality" added in the last 10~12 years. Utilize, never needed to replace the word use. And while I am on the soap box, When did the word button start being pronounced but-in. Garden, now pronounced gar-din. Classic example of school no longer teaching students how to read the dictionary. All future left voters. I thought it was the inbread homeschooled backwoods southern repugnicans who couldn't read or write past a 3rd grade level. Those and the sons of rich new york mobsters that run for president as a way to "improve their brand" In other word - current "right" voters (or at least TRUMP voters) and Trump offspring |
#20
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On Fri, 8 Mar 2019 11:12:19 -0800 (PST), DerbyDad03
wrote: On Friday, March 8, 2019 at 1:25:44 PM UTC-5, Leon wrote: On 3/8/2019 11:12 AM, -MIKE- wrote: On 3/8/19 11:03 AM, Leon wrote: I saw this and was wondering how long it has been around and how does it work.* What is it made out of to deliver electricity? https://www.lowesforpros.com/pd/Sout...e-Roll/1193433 What am I missing?* Are they actually talking about the casing?* The casing is not wire... I believe the Non-Metallic (NM) means the sheathing is made of plastic, not metal. There are times when it's required to have metal-sheathed wire and times when you can use Romex, non-metallic sheathed wire. So that's the designation.* MC for metal clad, and NM for non-metallic. Understood but it specifically says non metallic "wire". And I do not ever recall Romex ever being called metallic or non metallic. It's not uncommon, assuming that you accept that by referring to something by using the initials NM, it is being referred to as non-metallic. https://www.thespruce.com/what-does-...m-mean-1821530 "Romex® is the specific brand name for a non-metallic (NM) building wire made by Southwire. In other words, Romex® is technically just one brand of NM cable. However, the term Romex is often used generically (though inaccurately) to describe any type of NM cable, no matter which manufacturer made it." "Romex" is not wire - it is CABLE. A "wire" is a single conductor |
#21
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On Friday, March 8, 2019 at 9:00:49 PM UTC-5, gray_wolf wrote:
On 3/8/2019 11:03 AM, Leon wrote: I saw this and was wondering how long it has been around and how does it work. What is it made out of to deliver electricity? https://www.lowesforpros.com/pd/Sout...e-Roll/1193433 What am I missing?Â* Are they actually talking about the casing?Â* The casing is not wire... Apparently they are talking about the casing. Down at the bottom of the page they say Copper conductors are annealed (soft) copper. Poorly written ad. Can anyone here name a non-metallic material that a good conductor of electricity? Who educates these people? Water |
#22
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On Fri, 8 Mar 2019 11:47:32 -0800 (PST), DerbyDad03
wrote: On Friday, March 8, 2019 at 1:25:44 PM UTC-5, Leon wrote: On 3/8/2019 11:12 AM, -MIKE- wrote: On 3/8/19 11:03 AM, Leon wrote: I saw this and was wondering how long it has been around and how does it work.* What is it made out of to deliver electricity? https://www.lowesforpros.com/pd/Sout...e-Roll/1193433 What am I missing?* Are they actually talking about the casing?* The casing is not wire... I believe the Non-Metallic (NM) means the sheathing is made of plastic, not metal. There are times when it's required to have metal-sheathed wire and times when you can use Romex, non-metallic sheathed wire. So that's the designation.* MC for metal clad, and NM for non-metallic. Understood but it specifically says non metallic "wire". And I do not ever recall Romex ever being called metallic or non metallic. Interesting story (at least to me) about NM wire. I'm sure that most of us are familiar with the "cloth covered" NM wiring in older homes. You know, same concept as Romex, except that all the sheathing is cloth, not plastic. Well... The original "romex" WAS the tar/paper/fabrick covered stuff. My godparents lived on Narragansett Blvd in Chicopee MA. (be sure to remember the name of that street) Their house was where I learned about knob-and-tube wiring as a teenager. I helped my godfather pull some new wires through the K&T fixtures. It was my first experience with house wiring. Fast forward a decade or so when I was about to buy my first house, a house located in western NY. While visiting my godparents they handed me a wad of cash to help with the down-payment. So, I move in and I'm getting ready to do some wiring work on my own house. A house that some nice folks that lived on Narragansett Blvd helped me buy. Narragansett Blvd, where I had my very first experience with house wiring. Imagine my surprise when I looked at the cloth covered NM wiring and noticed the name "Narragansett Wire Company" printed on the sheathing! That was a very spooky feeling! |
#23
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On Friday, March 8, 2019 at 9:00:49 PM UTC-5, gray_wolf wrote:
On 3/8/2019 11:03 AM, Leon wrote: I saw this and was wondering how long it has been around and how does it work. What is it made out of to deliver electricity? https://www.lowesforpros.com/pd/Sout...e-Roll/1193433 What am I missing?Â* Are they actually talking about the casing?Â* The casing is not wire... Apparently they are talking about the casing. Down at the bottom of the page they say Copper conductors are annealed (soft) copper. Poorly written ad. Can anyone here name a non-metallic material that a good conductor of electricity? Who educates these people? Air (at high enough voltages) Ever heard of lightening? |
#24
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On Friday, March 8, 2019 at 9:55:31 PM UTC-5, DerbyDad03 wrote:
On Friday, March 8, 2019 at 9:00:49 PM UTC-5, gray_wolf wrote: On 3/8/2019 11:03 AM, Leon wrote: I saw this and was wondering how long it has been around and how does it work. What is it made out of to deliver electricity? https://www.lowesforpros.com/pd/Sout...e-Roll/1193433 What am I missing?Â* Are they actually talking about the casing?Â* The casing is not wire... Apparently they are talking about the casing. Down at the bottom of the page they say Copper conductors are annealed (soft) copper. Poorly written ad. Can anyone here name a non-metallic material that a good conductor of electricity? Who educates these people? Air (at high enough voltages) Ever heard of lightening? Without the "e"? ;-) |
#25
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On Friday, March 8, 2019 at 9:53:21 PM UTC-5, Clare Snyder wrote:
On Fri, 8 Mar 2019 11:47:32 -0800 (PST), DerbyDad03 wrote: On Friday, March 8, 2019 at 1:25:44 PM UTC-5, Leon wrote: On 3/8/2019 11:12 AM, -MIKE- wrote: On 3/8/19 11:03 AM, Leon wrote: I saw this and was wondering how long it has been around and how does it work.Â* What is it made out of to deliver electricity? https://www.lowesforpros.com/pd/Sout...e-Roll/1193433 What am I missing?Â* Are they actually talking about the casing?Â* The casing is not wire... I believe the Non-Metallic (NM) means the sheathing is made of plastic, not metal. There are times when it's required to have metal-sheathed wire and times when you can use Romex, non-metallic sheathed wire. So that's the designation.Â* MC for metal clad, and NM for non-metallic. Understood but it specifically says non metallic "wire". And I do not ever recall Romex ever being called metallic or non metallic. Interesting story (at least to me) about NM wire. I'm sure that most of us are familiar with the "cloth covered" NM wiring in older homes. You know, same concept as Romex, except that all the sheathing is cloth, not plastic. Well... The original "romex" WAS the tar/paper/fabrick covered stuff. Romex® is the specific brand name for a non-metallic (NM) building wire made by Southwire. "tar/paper/fabrick covered stuff" was branded under other names, as is the plastic covered stuff sold today. The Narragansett Wire Company did not make "Romex". |
#26
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On 3/8/2019 8:56 PM, DerbyDad03 wrote:
On Friday, March 8, 2019 at 9:55:31 PM UTC-5, DerbyDad03 wrote: On Friday, March 8, 2019 at 9:00:49 PM UTC-5, gray_wolf wrote: On 3/8/2019 11:03 AM, Leon wrote: I saw this and was wondering how long it has been around and how does it work. What is it made out of to deliver electricity? https://www.lowesforpros.com/pd/Sout...e-Roll/1193433 What am I missing?Â* Are they actually talking about the casing?Â* The casing is not wire... Apparently they are talking about the casing. Down at the bottom of the page they say Copper conductors are annealed (soft) copper. Poorly written ad. Can anyone here name a non-metallic material that a good conductor of electricity? Who educates these people? Air (at high enough voltages) Ever heard of lightening? Without the "e"? ;-) concrete, leather, fabric. . . damn near anything if the moisture content and voltage are high enough. |
#27
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On Fri, 8 Mar 2019 20:00:46 -0600, gray_wolf
wrote: On 3/8/2019 11:03 AM, Leon wrote: I saw this and was wondering how long it has been around and how does it work. What is it made out of to deliver electricity? https://www.lowesforpros.com/pd/Sout...e-Roll/1193433 What am I missing?* Are they actually talking about the casing?* The casing is not wire... Apparently they are talking about the casing. Down at the bottom of the page they say Copper conductors are annealed (soft) copper. Poorly written ad. Can anyone here name a non-metallic material that a good conductor of electricity? Who educates these people? graphite isn't bad - then there are conductive gasses and PLASMA |
#28
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On Fri, 8 Mar 2019 18:52:44 -0800 (PST), DerbyDad03
wrote: On Friday, March 8, 2019 at 9:00:49 PM UTC-5, gray_wolf wrote: On 3/8/2019 11:03 AM, Leon wrote: I saw this and was wondering how long it has been around and how does it work. What is it made out of to deliver electricity? https://www.lowesforpros.com/pd/Sout...e-Roll/1193433 What am I missing?* Are they actually talking about the casing?* The casing is not wire... Apparently they are talking about the casing. Down at the bottom of the page they say Copper conductors are annealed (soft) copper. Poorly written ad. Can anyone here name a non-metallic material that a good conductor of electricity? Who educates these people? Wate actually, PURE water is a pretty lousy conductor - it is disolved mineral salts that make it a reasonable conductor. |
#29
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On Fri, 8 Mar 2019 19:02:30 -0800 (PST), DerbyDad03
wrote: On Friday, March 8, 2019 at 9:53:21 PM UTC-5, Clare Snyder wrote: On Fri, 8 Mar 2019 11:47:32 -0800 (PST), DerbyDad03 wrote: On Friday, March 8, 2019 at 1:25:44 PM UTC-5, Leon wrote: On 3/8/2019 11:12 AM, -MIKE- wrote: On 3/8/19 11:03 AM, Leon wrote: I saw this and was wondering how long it has been around and how does it work.* What is it made out of to deliver electricity? https://www.lowesforpros.com/pd/Sout...e-Roll/1193433 What am I missing?* Are they actually talking about the casing?* The casing is not wire... I believe the Non-Metallic (NM) means the sheathing is made of plastic, not metal. There are times when it's required to have metal-sheathed wire and times when you can use Romex, non-metallic sheathed wire. So that's the designation.* MC for metal clad, and NM for non-metallic. Understood but it specifically says non metallic "wire". And I do not ever recall Romex ever being called metallic or non metallic. Interesting story (at least to me) about NM wire. I'm sure that most of us are familiar with the "cloth covered" NM wiring in older homes. You know, same concept as Romex, except that all the sheathing is cloth, not plastic. Well... The original "romex" WAS the tar/paper/fabrick covered stuff. Romex® is the specific brand name for a non-metallic (NM) building wire made by Southwire. "tar/paper/fabrick covered stuff" was branded under other names, as is the plastic covered stuff sold today. The Narragansett Wire Company did not make "Romex". My dad was an electrician and pulled miles of ROMEX Long before the plastic stuff came out. Invented and trademarked in 1922 by the Rome Wire Co in Rome New York. First described in the NEC of 1926. Rome Wire became General Cable which was bought out by southwire in 2001 (sept 5, to be exact). Narragansett cable produced a "eomex" style cabble under the name NARAX. The original "fabric" romex type cable was in common use up until aproxemately 1975 when the price of the plastic insulated pruduct became competetive (available from the mid-sixties) The original romex used eubber insulated wire, with thermoplastic becoming common in the mid fifties. Dad came home blacker from his electrical work in the early years than he did from the iron foundry where he fed the Bessemer. |
#30
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On Fri, 08 Mar 2019 21:48:27 -0500, Clare Snyder wrote:
I thought it was the inbread homeschooled backwoods southern repugnicans who couldn't read or write past a 3rd grade level. Those and the sons of rich new york mobsters that run for president as a way to "improve their brand" In other word - current "right" voters (or at least TRUMP voters) and Trump offspring Looks like time to update the killfile: this kind of snide ad hominem bull**** is a complete waste of time, and totally out of place in an exchange of ideas and experience of woodworking. Colin |
#31
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On 3/8/19 8:42 PM, Spalted Walt wrote:
gray_wolf wrote: Can anyone here name a non-metallic material that a good conductor of electricity? Graphite https://www.youtube.com/embed/s9eE2jFoioM?autoplay=1&rel=0 We used to draw out DC circuits in pencil to test them out. -- -MIKE- "Playing is not something I do at night, it's my function in life" --Elvin Jones (1927-2004) -- www.mikedrums.com |
#32
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On 3/8/19 8:52 PM, DerbyDad03 wrote:
On Friday, March 8, 2019 at 9:00:49 PM UTC-5, gray_wolf wrote: On 3/8/2019 11:03 AM, Leon wrote: I saw this and was wondering how long it has been around and how does it work. What is it made out of to deliver electricity? https://www.lowesforpros.com/pd/Sout...e-Roll/1193433 What am I missing?Â* Are they actually talking about the casing?Â* The casing is not wire... Apparently they are talking about the casing. Down at the bottom of the page they say Copper conductors are annealed (soft) copper. Poorly written ad. Can anyone here name a non-metallic material that a good conductor of electricity? Who educates these people? Water Since we're talking science. To the best of my knowledge, technically, water will not conduct electricity. That is, pure H2O. Tap water, like in a tub when someone drops the hair dryer in it before the advent of GFI circuits, would obviously conduct electricity and electrocute the poor soul in the tub. However, it's not the water that is passing the electrons. It's the minerals in the tap water. Electric power plants use pure, distilled, H2O to cool their generators. If that water conducted electricity, it would short out the generators. At least, that's what my electrical engineer buddy who works for the 3rd largest power supplier in the US tells me. -- -MIKE- "Playing is not something I do at night, it's my function in life" --Elvin Jones (1927-2004) -- www.mikedrums.com |
#33
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On Friday, March 8, 2019 at 10:50:54 PM UTC-5, Clare Snyder wrote:
On Fri, 8 Mar 2019 19:02:30 -0800 (PST), DerbyDad03 wrote: On Friday, March 8, 2019 at 9:53:21 PM UTC-5, Clare Snyder wrote: On Fri, 8 Mar 2019 11:47:32 -0800 (PST), DerbyDad03 wrote: On Friday, March 8, 2019 at 1:25:44 PM UTC-5, Leon wrote: On 3/8/2019 11:12 AM, -MIKE- wrote: On 3/8/19 11:03 AM, Leon wrote: I saw this and was wondering how long it has been around and how does it work.Â* What is it made out of to deliver electricity? https://www.lowesforpros.com/pd/Sout...e-Roll/1193433 What am I missing?Â* Are they actually talking about the casing?Â* The casing is not wire... I believe the Non-Metallic (NM) means the sheathing is made of plastic, not metal. There are times when it's required to have metal-sheathed wire and times when you can use Romex, non-metallic sheathed wire. So that's the designation.Â* MC for metal clad, and NM for non-metallic. Understood but it specifically says non metallic "wire". And I do not ever recall Romex ever being called metallic or non metallic. Interesting story (at least to me) about NM wire. I'm sure that most of us are familiar with the "cloth covered" NM wiring in older homes. You know, same concept as Romex, except that all the sheathing is cloth, not plastic. Well... The original "romex" WAS the tar/paper/fabrick covered stuff. Romex® is the specific brand name for a non-metallic (NM) building wire made by Southwire. "tar/paper/fabrick covered stuff" was branded under other names, as is the plastic covered stuff sold today. The Narragansett Wire Company did not make "Romex". My dad was an electrician and pulled miles of ROMEX Long before the plastic stuff came out. Invented and trademarked in 1922 by the Rome Wire Co in Rome New York. First described in the NEC of 1926. Rome Wire became General Cable which was bought out by southwire in 2001 (sept 5, to be exact). Narragansett cable produced a "eomex" style cabble under the name NARAX. The original "fabric" romex type cable was in common use up until aproxemately 1975 when the price of the plastic insulated pruduct became competetive (available from the mid-sixties) The original romex used eubber insulated wire, with thermoplastic becoming common in the mid fifties. Dad came home blacker from his electrical work in the early years than he did from the iron foundry where he fed the Bessemer. So, basically, you just used a lot more words to say exactly what I said. Romex is brand name. |
#34
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On Friday, March 8, 2019 at 11:03:05 PM UTC-5, -MIKE- wrote:
On 3/8/19 8:52 PM, DerbyDad03 wrote: On Friday, March 8, 2019 at 9:00:49 PM UTC-5, gray_wolf wrote: On 3/8/2019 11:03 AM, Leon wrote: I saw this and was wondering how long it has been around and how does it work. What is it made out of to deliver electricity? https://www.lowesforpros.com/pd/Sout...e-Roll/1193433 What am I missing?Â* Are they actually talking about the casing?Â* The casing is not wire... Apparently they are talking about the casing. Down at the bottom of the page they say Copper conductors are annealed (soft) copper. Poorly written ad. Can anyone here name a non-metallic material that a good conductor of electricity? Who educates these people? Water Since we're talking science. To the best of my knowledge, technically, water will not conduct electricity. That is, pure H2O. Tap water, like in a tub when someone drops the hair dryer in it before the advent of GFI circuits, would obviously conduct electricity and electrocute the poor soul in the tub. However, it's not the water that is passing the electrons. It's the minerals in the tap water. Electric power plants use pure, distilled, H2O to cool their generators. If that water conducted electricity, it would short out the generators. At least, that's what my electrical engineer buddy who works for the 3rd largest power supplier in the US tells me. Sure *pure* water doesn't conduct electricity. However, I'm pretty sure that it's a rare case that any of us are going to be near non-conductive water and electricity at the same time. If I see water, I'm going to assume that it will conduct. It's safer that way. ;-) |
#35
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On Friday, March 8, 2019 at 10:50:59 PM UTC-5, Colin Campbell wrote:
On Fri, 08 Mar 2019 21:48:27 -0500, Clare Snyder wrote: I thought it was the inbread homeschooled backwoods southern repugnicans who couldn't read or write past a 3rd grade level. Those and the sons of rich new york mobsters that run for president as a way to "improve their brand" In other word - current "right" voters (or at least TRUMP voters) and Trump offspring Looks like time to update the killfile: this kind of snide ad hominem bull**** is a complete waste of time, and totally out of place in an exchange of ideas and experience of woodworking. Colin I assume that you are going to killfile those on both sides of that conversation, right? You seemed to have snipped the original comment that prompted that response. Wouldn't it be hypocritical to killfile one, but not the other? Hmmm...come to think of it, this entire thread is totally out of place in an exchange of ideas and experience of woodworking. Your killfile is going to wipe out more than a couple of the few people left that actually discuss woodworking. |
#36
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On 3/8/19 10:29 PM, DerbyDad03 wrote:
On Friday, March 8, 2019 at 11:03:05 PM UTC-5, -MIKE- wrote: On 3/8/19 8:52 PM, DerbyDad03 wrote: On Friday, March 8, 2019 at 9:00:49 PM UTC-5, gray_wolf wrote: On 3/8/2019 11:03 AM, Leon wrote: I saw this and was wondering how long it has been around and how does it work. What is it made out of to deliver electricity? https://www.lowesforpros.com/pd/Sout...e-Roll/1193433 What am I missing?Â* Are they actually talking about the casing?Â* The casing is not wire... Apparently they are talking about the casing. Down at the bottom of the page they say Copper conductors are annealed (soft) copper. Poorly written ad. Can anyone here name a non-metallic material that a good conductor of electricity? Who educates these people? Water Since we're talking science. To the best of my knowledge, technically, water will not conduct electricity. That is, pure H2O. Tap water, like in a tub when someone drops the hair dryer in it before the advent of GFI circuits, would obviously conduct electricity and electrocute the poor soul in the tub. However, it's not the water that is passing the electrons. It's the minerals in the tap water. Electric power plants use pure, distilled, H2O to cool their generators. If that water conducted electricity, it would short out the generators. At least, that's what my electrical engineer buddy who works for the 3rd largest power supplier in the US tells me. Sure *pure* water doesn't conduct electricity. However, I'm pretty sure that it's a rare case that any of us are going to be near non-conductive water and electricity at the same time. If I see water, I'm going to assume that it will conduct. It's safer that way. ;-) He said water. :-p -- -MIKE- "Playing is not something I do at night, it's my function in life" --Elvin Jones (1927-2004) -- www.mikedrums.com |
#37
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
Clare Snyder wrote:
I thought it was the inbread homeschooled backwoods southern repugnicans who couldn't read or write past a 3rd grade level. Those and the sons of rich new york mobsters that run for president as a way to "improve their brand" In other word - current "right" voters (or at least TRUMP voters) and Trump offspring https://i.imgur.com/ikbFXCw.jpg |
#38
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On 3/8/2019 10:03 PM, -MIKE- wrote:
.... Electric power plants use pure, distilled, H2O to cool their generators. Â*If that water conducted electricity, it would short out the generators. At least, that's what my electrical engineer buddy who works for the 3rd largest power supplier in the US tells me. While air, water and oil all have been (and still are in some cases) used for cooling, modern large power generators use H gas for generator cooling since its comparable low density, high specific heat and thermal conductivity allows a significant improvement in efficiency and commensurate reduction in size/expense. -- |
#39
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On 3/8/2019 9:15 PM, Unquestionably Confused wrote:
.... concrete, leather, fabric. . . damn near anything if the moisture content and voltage are high enough. In which case it is the ionized material that is the conductor... -- |
#40
Posted to rec.woodworking
|
|||
|
|||
Non-Metalic Wire?
On Sat, 9 Mar 2019 08:47:19 -0600, dpb wrote:
On 3/8/2019 10:03 PM, -MIKE- wrote: ... Electric power plants use pure, distilled, H2O to cool their generators. *If that water conducted electricity, it would short out the generators. At least, that's what my electrical engineer buddy who works for the 3rd largest power supplier in the US tells me. While air, water and oil all have been (and still are in some cases) used for cooling, modern large power generators use H gas for generator cooling since its comparable low density, high specific heat and thermal conductivity allows a significant improvement in efficiency and commensurate reduction in size/expense. Hydrogen sounds really dangerous around a generator (unless it's used as the fuel also). He is used as a coolant and, like water, won't go boom. He is as non-reactive as you can get. |
Reply |
|
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Metalic finish car paint. | UK diy | |||
non-toxic high-temperature non-stick paint | UK diy | |||
Non-yellowing, thin, non-gloss clear finish for maple? | UK diy | |||
Maintained, non-maintained or non-existant? | UK diy | |||
Non-fused and non-earthed | UK diy |