Do thermal fuses fail from old age?
'Course the minuscule size of today's electronics and my aging
eyesight makes it a no-win game for me to try and do much fixing of that kind of stuff those days. I just bought an illuminated head-mount magnifier from Harbor Freight for $5. It's surprisingly good. The optics have little distortion and no chromatic aberration. There are four magnifications, but the lights "focus" at only the lowest magnification. |
#42
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
On Fri, 23 Mar 2012 12:48:47 -0700, "William Sommerwerck"
wrote: 'Course the minuscule size of today's electronics and my aging eyesight makes it a no-win game for me to try and do much fixing of that kind of stuff those days. I just bought an illuminated head-mount magnifier from Harbor Freight for $5. It's surprisingly good. The optics have little distortion and no chromatic aberration. There are four magnifications, but the lights "focus" at only the lowest magnification. I don't really like the plastic head mounted magnifiers. I'm constantly going from whatever I'm working on, to picking up tools, soldering iron, parts, probes, etc, on the bench. I have to keep raising and lowering the magnifier in order to switch. With an LCD screen, everything is roughly the same distance away, so no raising or lowering. If I were to buy a head mounted magnifier, it will probably be a surgical loupe. https://www.google.com/search?q=surgical+loupe&tbm=isch Lots of styles and types to choose from, all seriously expensive. I've played with some and am rather impressed. If I can keep the working distance constant, it's as good or better than my USB camera microscope. Mounted on eyeglasses, they are a bit heavy, but headband mounts are available. -- Jeff Liebermann 150 Felker St #D http://www.LearnByDestroying.com Santa Cruz CA 95060 http://802.11junk.com Skype: JeffLiebermann AE6KS 831-336-2558 |
#43
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
William Sommerwerck wrote:
'Course the minuscule size of today's electronics and my aging eyesight makes it a no-win game for me to try and do much fixing of that kind of stuff those days. I just bought an illuminated head-mount magnifier from Harbor Freight for $5. It's surprisingly good. The optics have little distortion and no chromatic aberration. There are four magnifications, but the lights "focus" at only the lowest magnification. Those things and drugstore reading glasses are great if you happen to have just the right interpupillary distance. I buy lab glasses from Zenni Optical for about $35 a pair--+0.75 diopter for reading, +2.5 for close work, coated, good frames, just the right interpupillary distance to avoid eyestrain. Highly recommended. Cheers Phil Hobbs -- Dr Philip C D Hobbs Principal Consultant ElectroOptical Innovations LLC Optics, Electro-optics, Photonics, Analog Electronics 160 North State Road #203 Briarcliff Manor NY 10510 845-480-2058 hobbs at electrooptical dot net http://electrooptical.net |
#44
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
"Jeff Liebermann = Nut Case ****wit " The coffee distillery is double insulated, which means it doesn't need a ground pin on the power plug. Since a fault can affect either side of the power line in such a symmertical arrangement, two fuses are required. ** Horse manure. Yep. ** Glad you agree- ****wit. One fuse is sufficient to break the circuit in case of current overload. http://www.freewebs.com/valvewizard/fuses.html Some appliances use two fuses, one for live and one for neutral. While there is some argument against using a neutral fuse, there is no law against it (in the UK anyway). You can buy IEC inlet sockets with built-in fuse holders, which greatly simplifies construction. ** Utterly irrelevant crap. http://www.appliance411.com/faq/dryerheat.shtml There are 2 fuses or breakers for the dryer, both must be good in order for the dryer to function properly. ** That schem shows TWO PHASE power being used. You ****ing tenth wit. Thermal fuses act on temperature, not current at all. True. ** Glad you agree - ****head. The max current rating given by makers is based on self heating to ensure the fuse stays within temp rating tolerance. The max current rating is the maximum current at which it will operate safely without self-heating and blowing the fuse. ** There is only a few degrees of self heating at the rated current. So to melt the material inside takes at least 5 times that current. I found out the hard way that it's much like the rating on a typical wire fuse. If you run a 5A fuse, at 5 amps at room temperature, it will eventually blow. ** Wire fuses run very hot at rated current, the wire inside may bend or even glow in the dark - ie nothing like thermal fuses. Same with a thermal fuse. ** Blatant LIE. If you run it near it's rated maximum current (usually 5A, 15A, or 30A), it will eventually get warm enough to melt the wax and trip the fuse. ** MASSIVE BULL**** !!!!!!!!!! With a short circuit across the power line, the self-heating will blow the thermal fuse almost instantly. ** Nope - it will trip the supply breaker. With a 10 times or more overload, breakers trip in a few milliseconds. You stupid asshole. .... Phil |
#45
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
N_Cook wrote: Michael A. Terrell wrote in message m... N_Cook wrote: Perhaps the voltage rating was lower than the required use, ie in fused state not rated for the service voltage across the broken section so someone thought, I know , we'll put 2 in series ;-) Which would do nothing, if they couldnn't handle the voltage. Have you ever looked at the wiring in a furnace? They use multple thermal shutdowns, for liability in the US. so you have no visual sense for emoticons I did too many fire restoration jobs after a pair of switches failed and people died. I see no humor in people dying from failed and jury rigged repairs. Laugh all you want. It fits you. -- You can't have a sense of humor, if you have no sense. |
#46
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
The Daring Dufas wrote: P.S. They often get mad when someone like me is teasing them. o_O Some just consider the source, and ignore you. -- You can't have a sense of humor, if you have no sense. |
#47
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
On Thu, 22 Mar 2012 10:12:07 -0400, Phil Hobbs
wrote: Nasty cheap Chinese thermal fuses-higher rate of failure to open in a real overtemp condition-using two in series may keep your house from burning down, if they don't both fail the same way. Maybe. Such guesswork would be greatly reduced if the original poster would kindly provide the Braun model number. https://www.google.com/search?&q=braun+coffee+maker&tbm=isch If the coffee maker is of the drip type automatic variety, then there are two heaters. The upper heater, that heats the water before it goes through the coffee filter, and the warmer at the base, that keeps the pot of coffee warm. Such a derrangement requires two thermal fuses, one for each heater. Incidentally, I had a really old Mr Coffee maker overheat and melt the plastic case. The thermal fuse never blew. The consensus was that water somehow invaded the Microtemp thermal fuse, and rusted everything in place. -- Jeff Liebermann 150 Felker St #D http://www.LearnByDestroying.com Santa Cruz CA 95060 http://802.11junk.com Skype: JeffLiebermann AE6KS 831-336-2558 |
#48
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
On 3/23/2012 5:02 PM, Michael A. Terrell wrote:
N_Cook wrote: Michael A. wrote in message m... N_Cook wrote: Perhaps the voltage rating was lower than the required use, ie in fused state not rated for the service voltage across the broken section so someone thought, I know , we'll put 2 in series ;-) Which would do nothing, if they couldnn't handle the voltage. Have you ever looked at the wiring in a furnace? They use multple thermal shutdowns, for liability in the US. so you have no visual sense for emoticons I did too many fire restoration jobs after a pair of switches failed and people died. I see no humor in people dying from failed and jury rigged repairs. Laugh all you want. It fits you. I repaired a furnace for one of my favorite customers, a little old lady about 90 who had her children and grandchildren staying with her and she had no heat. I found that water flooding the basement had shorted out the control board for her furnace but some moron had bypassed the roll-out safety switch on the furnace because another safety wasn't working. Needless to say, I had to replace a whole section of the wiring harness because the flames blew back from the burners destroying the wiring. It was a lucky break that the burned wiring shorted out killing the furnace or I fear the house would have caught fire with all those folks in there. I wish I could get my hands around the neck of the asshole who decided it was a good idea to bypass the safety switches on that furnace. o_O TDD |
#49
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
The Daring Dufas wrote: On 3/23/2012 5:02 PM, Michael A. Terrell wrote: N_Cook wrote: Michael A. wrote in message m... N_Cook wrote: Perhaps the voltage rating was lower than the required use, ie in fused state not rated for the service voltage across the broken section so someone thought, I know , we'll put 2 in series ;-) Which would do nothing, if they couldnn't handle the voltage. Have you ever looked at the wiring in a furnace? They use multple thermal shutdowns, for liability in the US. so you have no visual sense for emoticons I did too many fire restoration jobs after a pair of switches failed and people died. I see no humor in people dying from failed and jury rigged repairs. Laugh all you want. It fits you. I repaired a furnace for one of my favorite customers, a little old lady about 90 who had her children and grandchildren staying with her and she had no heat. I found that water flooding the basement had shorted out the control board for her furnace but some moron had bypassed the roll-out safety switch on the furnace because another safety wasn't working. Needless to say, I had to replace a whole section of the wiring harness because the flames blew back from the burners destroying the wiring. It was a lucky break that the burned wiring shorted out killing the furnace or I fear the house would have caught fire with all those folks in there. I wish I could get my hands around the neck of the asshole who decided it was a good idea to bypass the safety switches on that furnace. o_O I used to subcontract electronic repair for a fire restoration company. Most of their jobs were to repair the buildings so the heirs could sell them. They wanted nothing to do with the place their parent or parents died. More than one death was caused by an incompetent repair. A thermal overload failed? No big deal: "he terminals on the wires will push together, so all I need is some tape and I'll charge the suckers a couple hundred dollars." TDD -- You can't have a sense of humor, if you have no sense. |
#50
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
Jeff Liebermann wrote in
: On Thu, 22 Mar 2012 19:30:18 -0400, jeff_wisnia wrote: 'Course the current miniscule size of todays electronics and my aging eyesight makes it a no-win game for me to try and do much fixing of that kind of stuff those days. I use a microscope camera: http://www.ebay.com/itm/260969643003 $30 I have it plugged into a junk computah and LCD display. The original plan was to attach it to a wrist strap, to make it easier for me to see what I'm doing while soldering, but that didn't work. So, I now use it on a plastic camera tripod, which works well. Saving the JPG's has been handy for recording my work. Unfortunately, I still have to wear my reading glasses in order to see the LCD display. You can also use some cell phone cameras as a microscope, if they have auto-focus (iPhone 3GS, most Droids, etc). I have reading glasses(2.75X) and also have a separate binocular magnifier of 2.5X. you can buy "clip-on" binocular magnifiers for pretty low cost on Ebay,I got mine for $5 USD,plus shipping. they either clip on your regular glasses,or clip on their own eyeglass frame. They are easier to see around than the hobby binoc flip-up magnifiers,when you don't need close up vision,you don't have to move them out of the way. -- Jim Yanik jyanik at localnet dot com |
#51
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
On 3/23/2012 7:06 PM, Michael A. Terrell wrote:
The Daring Dufas wrote: On 3/23/2012 5:02 PM, Michael A. Terrell wrote: N_Cook wrote: Michael A. wrote in message m... N_Cook wrote: Perhaps the voltage rating was lower than the required use, ie in fused state not rated for the service voltage across the broken section so someone thought, I know , we'll put 2 in series ;-) Which would do nothing, if they couldnn't handle the voltage. Have you ever looked at the wiring in a furnace? They use multple thermal shutdowns, for liability in the US. so you have no visual sense for emoticons I did too many fire restoration jobs after a pair of switches failed and people died. I see no humor in people dying from failed and jury rigged repairs. Laugh all you want. It fits you. I repaired a furnace for one of my favorite customers, a little old lady about 90 who had her children and grandchildren staying with her and she had no heat. I found that water flooding the basement had shorted out the control board for her furnace but some moron had bypassed the roll-out safety switch on the furnace because another safety wasn't working. Needless to say, I had to replace a whole section of the wiring harness because the flames blew back from the burners destroying the wiring. It was a lucky break that the burned wiring shorted out killing the furnace or I fear the house would have caught fire with all those folks in there. I wish I could get my hands around the neck of the asshole who decided it was a good idea to bypass the safety switches on that furnace. o_O I used to subcontract electronic repair for a fire restoration company. Most of their jobs were to repair the buildings so the heirs could sell them. They wanted nothing to do with the place their parent or parents died. More than one death was caused by an incompetent repair. A thermal overload failed? No big deal: "he terminals on the wires will push together, so all I need is some tape and I'll charge the suckers a couple hundred dollars." That's basically what the idiot did and I come across that sort of thing all the time across the many fields I work in. My friend GB who owned the mechanical company I often helped him with was very much like me in that we couldn't live with ourselves if we were to cheat folks. GB passed away last fall so I'm not doing much in the way of residential HVAC work but there is enough commercial work to keep me occupied along with all the other stuff. I see incompetent work and dangerous shortcuts quite often and I make sure the customer is aware of how dangerous that sort of thing is and I would be absolutely devastated if someone were harmed because of something I did, especially if it was a child. If you've ever come across the website "There, I Fixed It" and seen some of the insane shortcuts and godawful dangerous things people do you may laugh like I do because I've actually seen people do the same crazy things. o_O TDD |
#52
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
The Daring Dufas wrote: On 3/23/2012 7:06 PM, Michael A. Terrell wrote: The Daring Dufas wrote: I repaired a furnace for one of my favorite customers, a little old lady about 90 who had her children and grandchildren staying with her and she had no heat. I found that water flooding the basement had shorted out the control board for her furnace but some moron had bypassed the roll-out safety switch on the furnace because another safety wasn't working. Needless to say, I had to replace a whole section of the wiring harness because the flames blew back from the burners destroying the wiring. It was a lucky break that the burned wiring shorted out killing the furnace or I fear the house would have caught fire with all those folks in there. I wish I could get my hands around the neck of the asshole who decided it was a good idea to bypass the safety switches on that furnace. o_O I used to subcontract electronic repair for a fire restoration company. Most of their jobs were to repair the buildings so the heirs could sell them. They wanted nothing to do with the place their parent or parents died. More than one death was caused by an incompetent repair. A thermal overload failed? No big deal: "he terminals on the wires will push together, so all I need is some tape and I'll charge the suckers a couple hundred dollars." That's basically what the idiot did and I come across that sort of thing all the time across the many fields I work in. My friend GB who owned the mechanical company I often helped him with was very much like me in that we couldn't live with ourselves if we were to cheat folks. GB passed away last fall so I'm not doing much in the way of residential HVAC work but there is enough commercial work to keep me occupied along with all the other stuff. I see incompetent work and dangerous shortcuts quite often and I make sure the customer is aware of how dangerous that sort of thing is and I would be absolutely devastated if someone were harmed because of something I did, especially if it was a child. If you've ever come across the website "There, I Fixed It" and seen some of the insane shortcuts and godawful dangerous things people do you may laugh like I do because I've actually seen people do the same crazy things. o_O Ever looked at "White Trash Repairs"? Some dangerous idiots on that site like the guy who blows up microwave ovens, or the one making fireworks in his house. The losers who do some electrical work should have to live in the houses they wire. I installed the computer networking, fire alarms and TV antenna systems at a new college campus years ago. The HVAC crew was the biggest idiot's I've ever had the misfortune to work around. The blueprints showed where every air handler was supposed to go, so that the ducting would have plenty of clearance. They not only set them in the wrong places, one was backwards, with their wiring hanging from the 20 foot ceilings. the gofer for the general contractor kept running around pulling the fire boxes while I was trying to test the prewire, until I caught him in the act. I followed him to his bosses office and read him the riot act. Then I promised to kick his sorry ass all the way across the campus if anyone pulled another box. he told me I couldn't do it, but his boss said that he would be a fool to try, and find out for sure. When it was time for the state inspector & his punch list he said the system failed, because the glass break rods were missing. I told him they would be installed, but only after the building was accepted and that the weren't installed due to over 100 attempts to cause a false alarm. That was the last time I did any sub work for that electrical contractor. -- You can't have a sense of humor, if you have no sense. |
#53
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
On 3/23/2012 9:36 PM, Michael A. Terrell wrote:
The Daring Dufas wrote: On 3/23/2012 7:06 PM, Michael A. Terrell wrote: The Daring Dufas wrote: I repaired a furnace for one of my favorite customers, a little old lady about 90 who had her children and grandchildren staying with her and she had no heat. I found that water flooding the basement had shorted out the control board for her furnace but some moron had bypassed the roll-out safety switch on the furnace because another safety wasn't working. Needless to say, I had to replace a whole section of the wiring harness because the flames blew back from the burners destroying the wiring. It was a lucky break that the burned wiring shorted out killing the furnace or I fear the house would have caught fire with all those folks in there. I wish I could get my hands around the neck of the asshole who decided it was a good idea to bypass the safety switches on that furnace. o_O I used to subcontract electronic repair for a fire restoration company. Most of their jobs were to repair the buildings so the heirs could sell them. They wanted nothing to do with the place their parent or parents died. More than one death was caused by an incompetent repair. A thermal overload failed? No big deal: "he terminals on the wires will push together, so all I need is some tape and I'll charge the suckers a couple hundred dollars." That's basically what the idiot did and I come across that sort of thing all the time across the many fields I work in. My friend GB who owned the mechanical company I often helped him with was very much like me in that we couldn't live with ourselves if we were to cheat folks. GB passed away last fall so I'm not doing much in the way of residential HVAC work but there is enough commercial work to keep me occupied along with all the other stuff. I see incompetent work and dangerous shortcuts quite often and I make sure the customer is aware of how dangerous that sort of thing is and I would be absolutely devastated if someone were harmed because of something I did, especially if it was a child. If you've ever come across the website "There, I Fixed It" and seen some of the insane shortcuts and godawful dangerous things people do you may laugh like I do because I've actually seen people do the same crazy things. o_O Ever looked at "White Trash Repairs"? Some dangerous idiots on that site like the guy who blows up microwave ovens, or the one making fireworks in his house. The losers who do some electrical work should have to live in the houses they wire. I installed the computer networking, fire alarms and TV antenna systems at a new college campus years ago. The HVAC crew was the biggest idiot's I've ever had the misfortune to work around. The blueprints showed where every air handler was supposed to go, so that the ducting would have plenty of clearance. They not only set them in the wrong places, one was backwards, with their wiring hanging from the 20 foot ceilings. the gofer for the general contractor kept running around pulling the fire boxes while I was trying to test the prewire, until I caught him in the act. I followed him to his bosses office and read him the riot act. Then I promised to kick his sorry ass all the way across the campus if anyone pulled another box. he told me I couldn't do it, but his boss said that he would be a fool to try, and find out for sure. When it was time for the state inspector& his punch list he said the system failed, because the glass break rods were missing. I told him they would be installed, but only after the building was accepted and that the weren't installed due to over 100 attempts to cause a false alarm. That was the last time I did any sub work for that electrical contractor. I will no longer tolerate sabotage or someone fooling around with my work on a construction project. I've decided the best thing to do is call the police and file a report along with a dollar value of the damage based on my highest hourly rate. I will definitely have one of perpetrators jailed on felony charges if the dollar amount is enough. The police reports come in handy for a lawsuit against a contractor with a "Screw You!" attitude. I was doing some control work with an engineer friend of mine I had met when we worked on a construction project for The Star Wars "SDI" program back in the 80's and we were installing a large HVAC control system for a new school in the 90's and on that job, one of the young don't give a damn electricians decided to cut and pull our control wire out of a roof penetration conduit so he could use it. The conduit was 40' in the air and luckily one of the other electricians told us before the ceiling was installed. The kid's excuse for ripping out our wire was that it was in his way and when asked why he didn't tell us so we could handle the problem was the fact that we weren't there that day. I don't know if personal civilian Tasers were available at the time but I would have liked to have owned one. ^_^ P.S. Some day I'll have to tell you of my adventures the with the Halon fire suppression system I installed in Mission Control at the missile range. o_O TDD |
#54
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
On Fri, 23 Mar 2012 22:36:09 -0400, "Michael A. Terrell"
wrote: Ever looked at "White Trash Repairs"? http://thereifixedit.failblog.org -- Jeff Liebermann 150 Felker St #D http://www.LearnByDestroying.com Santa Cruz CA 95060 http://802.11junk.com Skype: JeffLiebermann AE6KS 831-336-2558 |
#55
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
Maybe their thermal fuses opened?
Christopher A. Young Learn more about Jesus www.lds.org .. "Michael A. Terrell" wrote in message m... The Daring Dufas wrote: P.S. They often get mad when someone like me is teasing them. o_O Some just consider the source, and ignore you. -- You can't have a sense of humor, if you have no sense. |
#56
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
Not only thermal fuses, as you've found. I've also seen compressor thermal
overloads hanging loose in the air. With the compressor cooking hot. One other one I saw, was a dehumidifier (commercial model, mounted in a cellar) that would regularly freeze over. I had a look, and find the freeze sensor hanging in the air, rather than clipped to the (frozen) suction line. Christopher A. Young Learn more about Jesus www.lds.org .. "Michael A. Terrell" wrote in message m... I used to subcontract electronic repair for a fire restoration company. Most of their jobs were to repair the buildings so the heirs could sell them. They wanted nothing to do with the place their parent or parents died. More than one death was caused by an incompetent repair. A thermal overload failed? No big deal: "he terminals on the wires will push together, so all I need is some tape and I'll charge the suckers a couple hundred dollars." -- You can't have a sense of humor, if you have no sense. |
#57
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
using other contractor's penetrations
Reminds me of the one time I was helping extend some HVAC duct work. The
other fellow had spent all day cutting a rectangle shaped hole in a cinderblock wall. We came back the next day, the cable TV installer had run a wire diagonally through our hard won duct hole. I suggested taking the wire out with diags. Christopher A. Young Learn more about Jesus www.lds.org .. "The Daring Dufas" wrote in message ... I was doing some control work with an engineer friend of mine I had met when we worked on a construction project for The Star Wars "SDI" program back in the 80's and we were installing a large HVAC control system for a new school in the 90's and on that job, one of the young don't give a damn electricians decided to cut and pull our control wire out of a roof penetration conduit so he could use it. The conduit was 40' in the air and luckily one of the other electricians told us before the ceiling was installed. The kid's excuse for ripping out our wire was that it was in his way and when asked why he didn't tell us so we could handle the problem was the fact that we weren't there that day. I don't know if personal civilian Tasers were available at the time but I would have liked to have owned one. ^_^ TDD |
#58
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
halon system
I'd like to hear. I've learned a litle about these, but I'm sure your first
hand experience will be interesting. Christopher A. Young Learn more about Jesus www.lds.org .. "The Daring Dufas" wrote in message ... P.S. Some day I'll have to tell you of my adventures the with the Halon fire suppression system I installed in Mission Control at the missile range. o_O TDD |
#59
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
work place sabotage
I've seen some moments when people weren't working together. But sabotage?
It's a shame that people make life dificult for each other, on purpose. Christopher A. Young Learn more about Jesus www.lds.org .. "The Daring Dufas" wrote in message ... I will no longer tolerate sabotage or someone fooling around with my work on a construction project. I've decided the best thing to do is call the police and file a report along with a dollar value of the damage based on my highest hourly rate. I will definitely have one of perpetrators jailed on felony charges if the dollar amount is enough. The police reports come in handy for a lawsuit against a contractor with a "Screw You!" attitude. TDD |
#60
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
"Infinite Energy 3.0" is wonderful. The creator went to a lot of trouble to
set it up. |
#61
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
My job involves repairing machines with thermal fuses. does anyone
make 20 amp or 30 amp rated ones? the machines i repair have 15 amp thermal fuses on high inrush loads, and the fuses fatigue fail from being close to or at their current limit. the machines draw a instaneous 20 amps for a moment on start up i would rather install a higher amp fuse, of the right temp, and save tons of time and gasoline replacing the same part over and over again......... |
#62
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
On Sat, 24 Mar 2012 09:24:35 -0700 (PDT), bob haller
wrote: My job involves repairing machines with thermal fuses. does anyone make 20 amp or 30 amp rated ones? http://www.thermodisc.com/uploads/specs/TCO.pdf G8 series goes to 25A. -- Jeff Liebermann 150 Felker St #D http://www.LearnByDestroying.com Santa Cruz CA 95060 http://802.11junk.com Skype: JeffLiebermann AE6KS 831-336-2558 |
#63
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
Jeff Liebermann wrote:
On Thu, 22 Mar 2012 10:12:07 -0400, Phil Hobbs wrote: Nasty cheap Chinese thermal fuses-higher rate of failure to open in a real overtemp condition-using two in series may keep your house from burning down, if they don't both fail the same way. Maybe. Such guesswork would be greatly reduced if the original poster would kindly provide the Braun model number. https://www.google.com/search?&q=braun+coffee+maker&tbm=isch If the coffee maker is of the drip type automatic variety, then there are two heaters. The upper heater, that heats the water before it goes through the coffee filter, and the warmer at the base, that keeps the pot of coffee warm. Such a derrangement requires two thermal fuses, one for each heater. Incidentally, I had a really old Mr Coffee maker overheat and melt the plastic case. The thermal fuse never blew. The consensus was that water somehow invaded the Microtemp thermal fuse, and rusted everything in place. Our Bunn is a Model GRX. The two thermal series connected fuses are both located side by side on top of the heated water tank. There was no accessable thermal fuse I could see located on the warmer heater, but maybe one was buried inside it. Jeff -- Jeffry Wisnia (W1BSV + Brass Rat '57 EE) The speed of light is 1.8*10e12 furlongs per fortnight. |
#64
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
using other contractor's penetrations
On 3/24/2012 7:30 AM, Stormin Mormon wrote:
Reminds me of the one time I was helping extend some HVAC duct work. The other fellow had spent all day cutting a rectangle shaped hole in a cinderblock wall. We came back the next day, the cable TV installer had run a wire diagonally through our hard won duct hole. I suggested taking the wire out with diags. Christopher A. Young Learn more about Jesus www.lds.org . "The Daring wrote in message ... I was doing some control work with an engineer friend of mine I had met when we worked on a construction project for The Star Wars "SDI" program back in the 80's and we were installing a large HVAC control system for a new school in the 90's and on that job, one of the young don't give a damn electricians decided to cut and pull our control wire out of a roof penetration conduit so he could use it. The conduit was 40' in the air and luckily one of the other electricians told us before the ceiling was installed. The kid's excuse for ripping out our wire was that it was in his way and when asked why he didn't tell us so we could handle the problem was the fact that we weren't there that day. I don't know if personal civilian Tasers were available at the time but I would have liked to have owned one. ^_^ TDD TDD - Please fix your newsreader so it indents the previous poster's contribution. It's very confusing when its all at the same indent level. |
#65
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
Would it help to put two thermals, in parallel?
Christopher A. Young Learn more about Jesus www.lds.org .. "bob haller" wrote in message ... My job involves repairing machines with thermal fuses. does anyone make 20 amp or 30 amp rated ones? the machines i repair have 15 amp thermal fuses on high inrush loads, and the fuses fatigue fail from being close to or at their current limit. the machines draw a instaneous 20 amps for a moment on start up i would rather install a higher amp fuse, of the right temp, and save tons of time and gasoline replacing the same part over and over again......... |
#66
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
On Sat, 24 Mar 2012 14:04:36 -0400, "Stormin Mormon"
wrote: Would it help to put two thermals, in parallel? No. You could not guarantee that the current would split evenly between the two thermal fuses. A more serious problem is that it would require BOTH thermal fuses to blow in order to protect the appliance. -- Jeff Liebermann 150 Felker St #D http://www.LearnByDestroying.com Santa Cruz CA 95060 http://802.11junk.com Skype: JeffLiebermann AE6KS 831-336-2558 |
#67
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
On Sat, 24 Mar 2012 13:11:45 -0400, jeff_wisnia
wrote: Our Bunn is a Model GRX. Thanks. Is it GRX-B, GRX-W, GRX-Basic??? http://www.walmart.com/ip/Bunn-O-Matic-10-cup-Black-Professional-Coffee-Brewer-GRX-B/4891346 http://www.bunnathome.com/products/velocity-brew/velocity-brew-gr http://www.bunnathome.com/sites/bunnathome.com/files/GR_use&carebooklet_english.pdf That style would require two thermal fuses. One on top and one on the warmer. I couldn't find anyone selling internal repair parts that might also have an exploded view showing the fuses. Looks like it has a 3 year warranty. Find your receipt. Support 1-800-352-2866. Call and ask. The two thermal series connected fuses are both located side by side on top of the heated water tank. Well, that's the most likely to overheat, but it certainly would not require two fuses to do the job. Something is wrong here. There was no accessable thermal fuse I could see located on the warmer heater, but maybe one was buried inside it. Maybe, but more likely the factory forgot to install one on the warmer. So they put it where it would fit easily, which is next to the upper heater fuse. QA? Whazzat? -- Jeff Liebermann 150 Felker St #D http://www.LearnByDestroying.com Santa Cruz CA 95060 http://802.11junk.com Skype: JeffLiebermann AE6KS 831-336-2558 |
#68
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
using other contractor's penetrations
On 3/24/2012 1:30 PM, mjb wrote:
On 3/24/2012 7:30 AM, Stormin Mormon wrote: Reminds me of the one time I was helping extend some HVAC duct work. The other fellow had spent all day cutting a rectangle shaped hole in a cinderblock wall. We came back the next day, the cable TV installer had run a wire diagonally through our hard won duct hole. I suggested taking the wire out with diags. Christopher A. Young Learn more about Jesus www.lds.org . "The Daring wrote in message ... I was doing some control work with an engineer friend of mine I had met when we worked on a construction project for The Star Wars "SDI" program back in the 80's and we were installing a large HVAC control system for a new school in the 90's and on that job, one of the young don't give a damn electricians decided to cut and pull our control wire out of a roof penetration conduit so he could use it. The conduit was 40' in the air and luckily one of the other electricians told us before the ceiling was installed. The kid's excuse for ripping out our wire was that it was in his way and when asked why he didn't tell us so we could handle the problem was the fact that we weren't there that day. I don't know if personal civilian Tasers were available at the time but I would have liked to have owned one. ^_^ TDD TDD - Please fix your newsreader so it indents the previous poster's contribution. It's very confusing when its all at the same indent level. Actually, Stormin Mormin is the one with the broken newsreader. |
#69
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
Jeffry Wisnia (W1BSV + Brass Rat '57 EE) The speed of light is 1.8*10e12 furlongs per fortnight. Jeff Liebermann wrote: On Sat, 24 Mar 2012 13:11:45 -0400, jeff_wisnia wrote: Our Bunn is a Model GRX. Thanks. Is it GRX-B, GRX-W, GRX-Basic??? http://www.walmart.com/ip/Bunn-O-Matic-10-cup-Black-Professional-Coffee-Brewer-GRX-B/4891346 http://www.bunnathome.com/products/velocity-brew/velocity-brew-gr http://www.bunnathome.com/sites/bunnathome.com/files/GR_use&carebooklet_english.pdf That style would require two thermal fuses. One on top and one on the warmer. I couldn't find anyone selling internal repair parts that might also have an exploded view showing the fuses. Looks like it has a 3 year warranty. Find your receipt. Support 1-800-352-2866. Call and ask. The two thermal series connected fuses are both located side by side on top of the heated water tank. Well, that's the most likely to overheat, but it certainly would not require two fuses to do the job. Something is wrong here. There was no accessable thermal fuse I could see located on the warmer heater, but maybe one was buried inside it. Maybe, but more likely the factory forgot to install one on the warmer. So they put it where it would fit easily, which is next to the upper heater fuse. QA? Whazzat? I'm finding it somewhat hard to believe that the warmer heater would overheat, since there's no thermostat in or on it which could fail in the closed mode and cause such overheating. I'll await comments from others regarding the need and/or usage of a thermal fuse on the warmer. Jeff |
#70
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
On Sat, 24 Mar 2012 08:48:09 +1100, "Phil Allison"
wrote: If you run it near it's rated maximum current (usually 5A, 15A, or 30A), it will eventually get warm enough to melt the wax and trip the fuse. ** MASSIVE BULL**** !!!!!!!!!! With a short circuit across the power line, the self-heating will blow the thermal fuse almost instantly. ** Nope - it will trip the supply breaker. With a 10 times or more overload, breakers trip in a few milliseconds. You stupid asshole. See: UL 60691 for testing of the the thermal fuse: http://bbs.dianyuan.com/bbs/u/32/1122972217.pdf Section 10.8 discusses its use as a short circuit protection overcurrent fuse. (This is rev 3. Rev 5 is the current version). -- Jeff Liebermann 150 Felker St #D http://www.LearnByDestroying.com Santa Cruz CA 95060 http://802.11junk.com Skype: JeffLiebermann AE6KS 831-336-2558 |
#71
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
On Sat, 24 Mar 2012 18:55:44 -0400, jeff_wisnia
wrote: I'm finding it somewhat hard to believe that the warmer heater would overheat, since there's no thermostat in or on it which could fail in the closed mode and cause such overheating. UL coffee maker standards: http://ulstandardsinfonet.ul.com/scopes/1082.html http://bbs.dianyuan.com/bbs/u/33/1127541096.pdf Section 18.x for thermal cutoff requirements. Section 23.x for whether a thermal cutoff is required. Table 33.1 shows the maximum temperature rise allowed. As I read between the lines, any part that might rise above the stated temperatures, requires a thermal fuse. UL 60691 for testing of the thermal fuse: http://bbs.dianyuan.com/bbs/u/32/1122972217.pdf Section 10.8 discusses its use as a short circuit protection fuse. You might find this interesting: http://www.fixya.com/search/p89511-bunn_nhb_coffee_maker/thermal_fuse It's a different model Bunn coffee maker, but the problems are probably similar. I'll await comments from others regarding the need and/or usage of a thermal fuse on the warmer. Ah, truth by consensus and acclamation. Much as I like the concept, I've seen it fail far too often. -- Jeff Liebermann 150 Felker St #D http://www.LearnByDestroying.com Santa Cruz CA 95060 http://802.11junk.com Skype: JeffLiebermann AE6KS 831-336-2558 |
#72
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
"Jeff Liberian" wrote in message
... On Sat, 24 Mar 2012 18:55:44 -0400, Jeff_wins wrote: I'll await comments from others regarding the need and/or usage of a thermal fuse on the warmer. Ah, truth by consensus and acclamation. Much as I like the concept, I've seen it fail far too often. If I were to reassemble the device differently than the way it was designed, I would be certain to run it in an area with nothing nearby that could catch fire for a while to see if the consensus was correct. (-: Protection devices are sometimes added to products when beta testing reveals a potentially dangerous condition. Their requirement might not be obvious by simple inspection later on. I would only omit a fuse or protective device if it was impossible to find an identical replacement. Even then, I would probably use the most similar component I could find. We're talking about a device that's often operating out a human's presence that has ignition potential. Bad kimshi. -- Bobby G. |
#73
Posted to sci.electronics.repair
|
|||
|
|||
halon system
"Stormin Mormon" wrote:
I'd like to hear. I've learned a litle about these, but I'm sure your first hand experience will be interesting. Christopher A. Young Learn more about Jesus www.lds.org . "The Daring Dufas" wrote in message ... P.S. Some day I'll have to tell you of my adventures the with the Halon fire suppression system I installed in Mission Control at the missile range. o_O TDD All I know, I got a little handheld unit. Aren't you suppose to vacate ? Greg |
#74
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
Well, Bob Haller said he had 15 amp thermals, and occasional 20 amp inrush.
Why would that need to be "current split evenly"? Supposing they are carrying 15 amps and 5 amps. What's the problem? If the thermals are properly placed, they would both melt open when the device overheated. And suppose one thermal fails from old age? Then, Bob is back where he was when he started. I don't see the big problem. Christopher A. Young Learn more about Jesus www.lds.org .. "Jeff Liebermann" wrote in message ... On Sat, 24 Mar 2012 14:04:36 -0400, "Stormin Mormon" wrote: Would it help to put two thermals, in parallel? No. You could not guarantee that the current would split evenly between the two thermal fuses. A more serious problem is that it would require BOTH thermal fuses to blow in order to protect the appliance. -- Jeff Liebermann 150 Felker St #D http://www.LearnByDestroying.com Santa Cruz CA 95060 http://802.11junk.com Skype: JeffLiebermann AE6KS 831-336-2558 |
#75
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
On Mar 25, 7:53*am, "Stormin Mormon"
wrote: Well, Bob Haller said he had 15 amp thermals, and occasional 20 amp inrush. Why would that need to be "current split evenly"? Supposing they are carrying 15 amps and 5 amps. What's the problem? If the thermals are properly placed, they would both melt open when the device overheated. And suppose one thermal fails from old age? Then, Bob is back where he was when he started. I don't see the big problem. Christopher A. Young Learn more about Jesus *www.lds.org . "Jeff Liebermann" wrote in message ... On Sat, 24 Mar 2012 14:04:36 -0400, "Stormin Mormon" wrote: Would it help to put two thermals, in parallel? No. *You could not guarantee that the current would split evenly between the two thermal fuses. *A more serious problem is that it would require BOTH thermal fuses to blow in order to protect the appliance. -- Jeff Liebermann * * 150 Felker St #D * *http://www.LearnByDestroying.com Santa Cruz CA 95060http://802.11junk.com Skype: JeffLiebermann * * AE6KS * *831-336-2558 I have used thermal fuses in parell. But really dont like it as it would cause too many problems if a fire occured. thanks for the link for the high current thermal fuses anything that decreases my gasoline expense is well worth it......... |
#76
Posted to sci.electronics.repair
|
|||
|
|||
Do thermal fuses fail from old age?
On Fri, 23 Mar 2012 13:27:05 -0700, Jeff Liebermann
wrote: On Fri, 23 Mar 2012 12:48:47 -0700, "William Sommerwerck" wrote: 'Course the minuscule size of today's electronics and my aging eyesight makes it a no-win game for me to try and do much fixing of that kind of stuff those days. I just bought an illuminated head-mount magnifier from Harbor Freight for $5. It's surprisingly good. The optics have little distortion and no chromatic aberration. There are four magnifications, but the lights "focus" at only the lowest magnification. I don't really like the plastic head mounted magnifiers. I'm constantly going from whatever I'm working on, to picking up tools, soldering iron, parts, probes, etc, on the bench. I have to keep raising and lowering the magnifier in order to switch. With an LCD screen, everything is roughly the same distance away, so no raising or lowering. If I were to buy a head mounted magnifier, it will probably be a surgical loupe. https://www.google.com/search?q=surgical+loupe&tbm=isch Lots of styles and types to choose from, all seriously expensive. I've played with some and am rather impressed. If I can keep the working distance constant, it's as good or better than my USB camera microscope. Mounted on eyeglasses, they are a bit heavy, but headband mounts are available. I use magnifiers in my work regularly and have been using a camera and display for some of the work I do. I bought a camera and lens and display and set it up for lathe work. But I need to get better components because some of the details I need to see accurately are less than .001". So even though the system I put together seemed at first to be fine it is still has problems with contrast and distortion. One thing that has really helped with magnifiers though is bright lights. The really bright lighting, by causing my pupils to constrict, gives me much more depth of field. Eric |
#77
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
On Sun, 25 Mar 2012 07:53:23 -0400, "Stormin Mormon"
wrote: Well, Bob Haller said he had 15 amp thermals, and occasional 20 amp inrush. Why would that need to be "current split evenly"? Supposing they are carrying 15 amps and 5 amps. What's the problem? A 15A thermal fuse will not blow on a 20A inrush. It needs some time to melt the wax inside the fuse and blow. I'm not sure how much is required to blow it up reliably, but a short circuit across the line should do the trick. The problem with unequal current distribution is that the fusing current is not predictable. However, you're partially correct. If one fuse blows at some current, the full current load will transfer to the other parallel fuse, which will then have enough current to blow. The problem is that if it takes one minute for the first fuse to blow, it will probably take more than an additional minute to blow the 2nd fuse because of the higher series resistance which is what causes the unequal current distribution in the first place. In effect, such a derangement extends the time it takes for the power to be cut, and a fire prevented. If the thermals are properly placed, they would both melt open when the device overheated. That's a big if. Presumably, if the heating element was one contiguous device, with no possibility of a partial short to the metal water tank, there would be no thermal gradient across the water tank. However, if the heater was a series of heating elements, distributed in some artistic pattern across the bottom of the water tank, and only a partial short occurs, the resulting thermal gradient will cause one thermal fuse to be much hotter than the other, especially if the water tank is empty. And suppose one thermal fails from old age? Then, Bob is back where he was when he started. From: UL 60691 Pg 17 NOTE 2 For reasons of safety, it should be made clear in the documentation that a THERMAL-LINK is a non-repairable item and that, in case of replacement, an equivalent THERMAL-LINK from the same manufacturer and having the same catalogue reference should be used, mounted in exactly the same way. This might explain why every pot warmer I could find has the plastic base solvent welded shut, or metal base riveted together, to prevent (or at least discourage) thermal fuse replacement. However, in the case of the coffee machine, UL contradicts itself: From: UL 1082 Pg 26 18.1 If an appliance is provided with a thermal cutoff, it shall be secured in place and shall be so located that it will be accessible for replacement without damaging other connections or internal wiring. See 50.6. So, one spec says it should be un repairable, while another says that it should be accessible for replacement. Toss a coin. Incidentally, if the thermal fuse blows, one should consider asking why it blew. It isn't always old age or crappy quality. There may be an intermittent or obscure fault causing it to blow. I don't see the big problem. Look harder and you'll see. What you're suggesting is not in itself unsafe. It is possible to run parallel thermal fuses and still have it perform its intended function. However, it's much safer to put them in series. -- Jeff Liebermann 150 Felker St #D http://www.LearnByDestroying.com Santa Cruz CA 95060 http://802.11junk.com Skype: JeffLiebermann AE6KS 831-336-2558 |
#78
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
On Mar 25, 7:01*pm, Jeff Liebermann wrote:
On Sun, 25 Mar 2012 07:53:23 -0400, "Stormin Mormon" wrote: Well, Bob Haller said he had 15 amp thermals, and occasional 20 amp inrush. Why would that need to be "current split evenly"? Supposing they are carrying 15 amps and 5 amps. What's the problem? A 15A thermal fuse will not blow on a 20A inrush. *It needs some time to melt the wax inside the fuse and blow. *I'm not sure how much is required to blow it up reliably, but a short circuit across the line should do the trick. The problem with unequal current distribution is that the fusing current is not predictable. *However, you're partially correct. *If one fuse blows at some current, the full current load will transfer to the other parallel fuse, which will then have enough current to blow. The problem is that if it takes one minute for the first fuse to blow, it will probably take more than an additional minute to blow the 2nd fuse because of the higher series resistance which is what causes the unequal current distribution in the first place. *In effect, such a derangement extends the time it takes for the power to be cut, and a fire prevented. If the thermals are properly placed, they would both melt open when the device overheated. That's a big if. *Presumably, if the heating element was one contiguous device, with no possibility of a partial short to the metal water tank, there would be no thermal gradient across the water tank. However, if the heater was a series of heating elements, distributed in some artistic pattern across the bottom of the water tank, and only a partial short occurs, the resulting thermal gradient will cause one thermal fuse to be much hotter than the other, especially if the water tank is empty. And suppose one thermal fails from old age? Then, Bob is back where he was when he started. From: UL 60691 Pg 17 * *NOTE 2 For reasons of safety, it should be made clear in the * *documentation that a THERMAL-LINK is a non-repairable item * *and that, in case of replacement, an equivalent THERMAL-LINK * *from the same manufacturer and having the same catalogue * *reference should be used, mounted in exactly the same way. This might explain why every pot warmer I could find has the plastic base solvent welded shut, or metal base riveted together, to prevent (or at least discourage) thermal fuse replacement. However, in the case of the coffee machine, UL contradicts itself: From: UL 1082 Pg 26 * *18.1 If an appliance is provided with a thermal cutoff, it * *shall be secured in place and shall be so located that it will * *be accessible for replacement without damaging other connections * *or internal wiring. See 50.6. So, one spec says it should be un repairable, while another says that it should be accessible for replacement. *Toss a coin. Incidentally, if the thermal fuse blows, one should consider asking why it blew. *It isn't always old age or crappy quality. *There may be an intermittent or obscure fault causing it to blow. I don't see the big problem. Look harder and you'll see. *What you're suggesting is not in itself unsafe. *It is possible to run parallel thermal fuses and still have it perform its intended function. *However, it's much safer to put them in series. -- Jeff Liebermann * * 150 Felker St #D * *http://www.LearnByDestroying.com Santa Cruz CA 95060http://802.11junk.com Skype: JeffLiebermann * * AE6KS * *831-336-2558 a 15 amp thermal fuse on a high inrush load causes premature failure of the fuse, not from device malfunction but the repeated high current rush. this can and does cause cause the thermal fuse to fail while the device is fine. with gasoline so expensive i want to minimize unnecessary calls. they annoy the customer and waste my time.// I am ordering some high current thermal fuses in the AM |
#79
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
On Sun, 25 Mar 2012 20:24:33 -0700 (PDT), bob haller
wrote: a 15 amp thermal fuse on a high inrush load causes premature failure of the fuse, not from device malfunction but the repeated high current rush. this can and does cause cause the thermal fuse to fail while the device is fine. with gasoline so expensive i want to minimize unnecessary calls. they annoy the customer and waste my time.// I am ordering some high current thermal fuses in the AM What is the device? I ask because it might be easier to install a thermistor inrush current limiter on the input power leads, than a bigger thermal fuse. Inrush current limiting devices: http://www.ametherm.com/inrush-current/ http://www.rtie.com/category-s/48.htm According to the data sheets they have devices rated from 1 to 36 amps. -- Jeff Liebermann 150 Felker St #D http://www.LearnByDestroying.com Santa Cruz CA 95060 http://802.11junk.com Skype: JeffLiebermann AE6KS 831-336-2558 |
#80
Posted to sci.electronics.repair,alt.home.repair
|
|||
|
|||
Do thermal fuses fail from old age?
On 3/25/2012 11:08 PM, Jeff Liebermann wrote:
On Sun, 25 Mar 2012 20:24:33 -0700 (PDT), bob wrote: a 15 amp thermal fuse on a high inrush load causes premature failure of the fuse, not from device malfunction but the repeated high current rush. this can and does cause cause the thermal fuse to fail while the device is fine. with gasoline so expensive i want to minimize unnecessary calls. they annoy the customer and waste my time.// I am ordering some high current thermal fuses in the AM What is the device? I ask because it might be easier to install a thermistor inrush current limiter on the input power leads, than a bigger thermal fuse. Inrush current limiting devices: http://www.ametherm.com/inrush-current/ http://www.rtie.com/category-s/48.htm According to the data sheets they have devices rated from 1 to 36 amps. Back about 4 decades when I tried my hand at TV repair, me and the guys I worked with had to replace a lot of what were called "glowbars/globars", they were actually PTC devices hooked to the degaussing coil around the CRT of a TV set to power the degaussing coil for a short period every time a TV set was turned on. When you first turn on a TV or CRT monitor equipped with one you may hear a "GRONK" sound and that's the degaussing circuit. The PTC thermistor allows a big rush of current to the coil until it heats up which causes its resistance to increase stopping the flow of current until it cools off. There could be a way to use a globar and one of those mil spec power resistors in that finned aluminum case that has mounting ears and one flat surface. The resister could be epoxied to the metal in the appliance and hooked in series with the thermistor across the incoming power to temper any inrush current before it hit the heating element circuit. I see several diagrams forming in my mind's eye including one with a low value power resister in series with the heating element connected to the thermistor circuit and another with an NTC device in series with the heating element and the power. The only problem would be coming up with a thermistor that could handle the current of the heating element when it's connected in series with it. Oh well, it's my mind, I'll have fun playing in there. ^_^ TDD |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Simple Question about Thermal Cutoff (tco) & Fuses | Electronics Repair | |||
MOT Fail | UK diy | |||
MOT fail ? | UK diy | |||
MOT fail ? | UK diy | |||
Can I Replace All My Fuses WIth Time Delay Fuses? | Home Repair |