Home |
Search |
Today's Posts |
![]() |
|
UK diy (uk.d-i-y) For the discussion of all topics related to diy (do-it-yourself) in the UK. All levels of experience and proficency are welcome to join in to ask questions or offer solutions. |
Reply |
|
LinkBack | Thread Tools | Display Modes |
#1
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
Hi all
I need to extend the Bowden cable for my bath pop-up waste. I have got a replacement cable and now struggling to fit it. The old cable is terminated at each end with a brass fitting which allows the full cable in one side but only the core the other. I had to cut the old sheath off the brass fitting and the bit inside came out buy twisting it with a pliers and pulling it out. Now having fitted the new one, when I operate the waste the sheath pops out of the brass fitting so just ends up using the force to move the sheath into a bit of an arc. It would appear that the sheath needs to be attached to the brass fitting somehow. Both old and new sheaths are a fairly loose fitting in the brass fitting so glue may not be strong enough (if I could work out which to use). The inside of the brass fitting is smooth so threading it on doesn't seem to be the trick either. Anyone have any idea how this is supposed to be attached ? Maybe I am missing something about how Bowden cables work and the sheath doesn't need to be attached. Any help appreciated Thanks Lee. |
#2
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
In article ,
wrote: Anyone have any idea how this is supposed to be attached ? Maybe I am missing something about how Bowden cables work and the sheath doesn't need to be attached. If you look at high load situations where you need flexible cables - like say a car gearchange - they generally use two so the load is taken by each as a pull. If you wish to have one which both pulls and pushes - for low load only - it need a solid inner (so far less flexible) and the outer secured at both ends. That can be with a clamp, or a crimped on ferrule secured to a bracket by a circlip, etc. -- *Wrinkled was not one of the things I wanted to be when I grew up Dave Plowman London SW To e-mail, change noise into sound. |
#3
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]() |
#4
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
On Sat, 09 Jun 2018 12:24:05 +0100, "Dave Plowman (News)"
wrote: In article , wrote: Anyone have any idea how this is supposed to be attached ? Maybe I am missing something about how Bowden cables work and the sheath doesn't need to be attached. If you look at high load situations where you need flexible cables - like say a car gearchange - they generally use two so the load is taken by each as a pull. I thought they generally had two for the two planes of movement, one doing the push pull and the other the rotation (to duplicate the 'H' gear selector gate)? If you wish to have one which both pulls and pushes - for low load only - it need a solid inner (so far less flexible) and the outer secured at both ends. That can be with a clamp, or a crimped on ferrule secured to a bracket by a circlip, etc. Yup, because the gear change on my Messerschmitt KR200 is 'sequential' it just has a push-pull cable with more rigid 'ends' where it connects to the gear change lever or gear selector arm on the engine. It actually travels in a open 'Z', from by your right knee, up the RHS of the cockpit, across the back and out into the engine bay and onto the engine. I think the brand is 'Teleflex'. http://www.tnorrismarine.co.uk/produ...-morse-cables/ Cheers, T i m |
#5
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
Thanks both. It works on a push and pull basis. Essentially when you turn the knob one way it pulls the inner cable which in turn pulls a lever at the plug end and the plug pops up (or down can't recall which way around). When you turn the knob in the opposite direction it pushes the lever at the plug end and the plug does the opposite.
I have both solid and stranded core to try once I get the mechanism working.. Sounds like I have to somehow secure the outer sheath to the brass fittings.. Any ideas? |
#6
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]() |
#7
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
Yes it is a steel spiral encased in plastic. The brass is thick (couple of mm) so no way to crimp it onto the sheath unfortunately.
|
#8
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]() |
#9
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
Thanks Fredxx. I am using the Google groups forum site so not sure why it doesn't quite the text.
Based on your post, am I supposed to cut the sheath such that it is tight between the 2 end points? I cut it with some slack to give me some room in case I needed to move something slightly. The brass on the fitting is around 2mm thick around the hole the sheath goes into. . The depth of the hole is around 6mm |
#10
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
Fredxx explained on 09/06/2018 :
Bowden cables are best where the sheath is in tension. They really don't work well in compression. Sheath in compression, inner in tension! |
#11
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
I can't put the sheath in compression as it runs from the trap of the bath up to the knob on top of the bath so needs to flex around contour of the bath.
|
#12
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]() |
#13
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
On 09/06/18 15:28, Harry Bloomfield wrote:
presented the following explanation : I can't put the sheath in compression as it runs from the trap of the bath up to the knob on top of the bath so needs to flex around contour of the bath. Usually Bowden cables work with the inner being pulled (tension) against the outer, which is compressed. Outers have limited ability to withstand tension, because if too much tension is applied, then they easily stretch. I don't think the outer compresses much. It is a spiral wrap so it is flexible but, as it bends, the spiral turns are in contact. I doubt the metal will compress much. The 'gap' between the turns on the outer of the bend may close a bit as the device is operated- typically you see the outer move a bit. As you say, the inner is under tension. |
#14
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
On 09/06/2018 15:11, Harry Bloomfield wrote:
Fredxx explained on 09/06/2018 : Bowden cables are best where the sheath is in tension. They really don't work well in compression. Sheath in compression, inner in tension! Apologies - spot on for noticing. |
#15
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
Brian Reay was thinking very hard :
I don't think the outer compresses much. It is a spiral wrap so it is flexible but, as it bends, the spiral turns are in contact. I doubt the metal will compress much. The 'gap' between the turns on the outer of the bend may close a bit as the device is operated- typically you see the outer move a bit. As you say, the inner is under tension. I agree, the outer doesn't compress much, but they come under compression when the lever or what ever is operated. |
#16
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]() |
#18
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
On 09/06/2018 12:24, Dave Plowman (News) wrote:
In article , wrote: Anyone have any idea how this is supposed to be attached ? Maybe I am missing something about how Bowden cables work and the sheath doesn't need to be attached. If you look at high load situations where you need flexible cables - like say a car gearchange - they generally use two so the load is taken by each as a pull. If you wish to have one which both pulls and pushes - for low load only - it need a solid inner (so far less flexible) and the outer secured at both ends. That can be with a clamp, or a crimped on ferrule secured to a bracket by a circlip, etc. Agreed. The common instance of a push-pull cable, in the good old days, was in car choke cables. IIRC bonnet releases also sometimes had (and still have) a solid inner. But then they have a pretty fixed run and don't need much flexibility. --- This email has been checked for viruses by Avast antivirus software. https://www.avast.com/antivirus |
#19
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
Looks like soldering the sheath into the fitting is the best next step. Do I use a normal blow torch and plumbers solder? Is also would the fit copper pipe?
|
#20
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
Hi all
I have taken some photos and tried to upload them to a public album (hopefully not done this for ages). They show the fittings and particularly the brass fitting I need to connect the sheath to. Hopefully this works https://photos.app.goo.gl/L44RinHPY2v2UeEbA I have tried some searching but can only find examples of soldering the fitting to the wire rather than the sheath to the fitting. They seemed to use "silver solder" which I assume is not the same as plumbing solder Thanks Lee. |
#21
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
wrote:
Hi all I have taken some photos and tried to upload them to a public album (hopefully not done this for ages). They show the fittings and particularly the brass fitting I need to connect the sheath to. Hopefully this works https://photos.app.goo.gl/L44RinHPY2v2UeEbA I have tried some searching but can only find examples of soldering the fitting to the wire rather than the sheath to the fitting. They seemed to use "silver solder" which I assume is not the same as plumbing solder Thanks Lee. I think this would have been crimped to the sheath originally. I doubt youll have much joy soldering. Id try epoxy resin or replace the whole mech (control and pop-up) as I doubt it was designed to be replace piecemeal. Tim -- Please don't feed the trolls |
#22
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
On 12/06/18 20:30, wrote:
Hi all I have taken some photos and tried to upload them to a public album (hopefully not done this for ages). They show the fittings and particularly the brass fitting I need to connect the sheath to. Hopefully this works https://photos.app.goo.gl/L44RinHPY2v2UeEbA I have tried some searching but can only find examples of soldering the fitting to the wire rather than the sheath to the fitting. They seemed to use "silver solder" which I assume is not the same as plumbing solder Thanks Lee. Bowden cables typically only work in tension so there is no need to fix the outer to the ferrule |
#23
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
The brass of the fitting it too thick for it to be crimped and it is perfectly smooth with no sign of buckling. A few people here have said the sheath needs to be under tension. Given the Bowden cable forms an arch from the waste to the knob, how do I put it under tension? Pushing the ends of the sheath just alters the curve of the arc. I suspect I am missing something - sorry
|
#24
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
wrote:
The brass of the fitting it too thick for it to be crimped and it is perfectly smooth with no sign of buckling. A few people here have said the sheath needs to be under tension. Given the Bowden cable forms an arch from the waste to the knob, how do I put it under tension? Pushing the ends of the sheath just alters the curve of the arc. I suspect I am missing something - sorry Its only under tension when you turn the knob to pop the plug up. Its not pre-tensioned. The sheath just has to be securely anchored at each end. Tim -- Please don't feed the trolls |
#25
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
Tim+ wrote:
wrote: The brass of the fitting it too thick for it to be crimped and it is perfectly smooth with no sign of buckling. A few people here have said the sheath needs to be under tension. Given the Bowden cable forms an arch from the waste to the knob, how do I put it under tension? Pushing the ends of the sheath just alters the curve of the arc. I suspect I am missing something - sorry Its only under tension when you turn the knob to pop the plug up. Its not pre-tensioned. The sheath just has to be securely anchored at each end. Tim Which is why typically replacement mechs incorporate both ends (with no need to cobble bits together). https://www.ebay.co.uk/itm/Concealed...e/171874130165 Tim -- Please don't feed the trolls |
#26
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
On Tue, 12 Jun 2018 12:30:52 -0700 (PDT), wrote:
Hi all I have taken some photos and tried to upload them to a public album (hopefully not done this for ages). They show the fittings and particularly the brass fitting I need to connect the sheath to. Hopefully this works https://photos.app.goo.gl/L44RinHPY2v2UeEbA A picture speaks 1000 words. ;-) I have tried some searching but can only find examples of soldering the fitting to the wire rather than the sheath to the fitting. They seemed to use "silver solder" which I assume is not the same as plumbing solder If that fitting is plastic and that brass socket doesn't release from the fitting I wouldn't want to solder it in place. As I believe has been mentioned, it might be best (therefore) to 'glue' the Bowden outer to the socket using a 'Liquid Metal' epoxy. The bond will be in shear and as long as it's all nice and clean and dry when done, shouldn't ever come out again. ;-) Cheers, T i m |
#27
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
Luckily the brass bit does come out it is secured using a clip the other side.
|
#28
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]() |
#29
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
On 12/06/2018 20:30, wrote:
Hi all I have taken some photos and tried to upload them to a public album (hopefully not done this for ages). They show the fittings and particularly the brass fitting I need to connect the sheath to. Hopefully this works https://photos.app.goo.gl/L44RinHPY2v2UeEbA I have tried some searching but can only find examples of soldering the fitting to the wire rather than the sheath to the fitting. They seemed to use "silver solder" which I assume is not the same as plumbing solder Thanks Lee. Very helpful. "Silver soldering" is done at red heat, I think even "soft soldering" (i.e. plumbing / electrical) will deform the plastic however careful you are. I would go for epoxy: abrade and degrease the parts first. Someone has already suggested this. --- This email has been checked for viruses by Avast antivirus software. https://www.avast.com/antivirus |
#30
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
On 13/06/2018 08:27, T i m wrote:
On Tue, 12 Jun 2018 23:32:31 -0700 (PDT), wrote: Luckily the brass bit does come out it is secured using a clip the other side. Whilst that is good, I'd still not bother trying to solder any of those bits together because it will still probably melt the sheath off the outer. Clean the inside of the brass bit out with some coarse abrasive paper / round file / sharp small screwdriver (to remove and debris and create a key) and clean both parts with a suitable solvent. Mix up some suitable quantity of a quality epoxy, apply to both parts, put together and leave 24 hours. Refit and just forever without that part ever being a problem ever again? Personally I think JB Weld would be ideal (if not overkill) but it's not quite so easy to get in the UK as it was (but still on eBay etc). Cheers, T i m Spot on, I was going to say the same thing. --- This email has been checked for viruses by Avast antivirus software. https://www.avast.com/antivirus |
#31
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
On Wed, 13 Jun 2018 09:23:54 +0100, newshound
wrote: SNIP Mix up some suitable quantity of a quality epoxy, apply to both parts, put together and leave 24 hours. Refit and just forever without that part ever being a problem ever again? Personally I think JB Weld would be ideal (if not overkill) but it's not quite so easy to get in the UK as it was (but still on eBay etc). Spot on, I was going to say the same thing. I think if you have tried to do this sort of thing before (and I have, many times) I think it's both the easiest and most-likely-to-succeed option. ;-) The key is the material to be glued. As long as it's all stuff that you have had experience of before and know it to be good, then the total outcome should be good. If one is (say) an unknown type of plastic then I might try a test first and go from there. The other thing is 'what are you trying to get the adhesive to do?' If it's to provide material / support itself then 'it' has to be strong enough to do so (like JB Weld). If you were retaining something that might need to move a bit but wouldn't have a lot of strain on it then something like silicone / Evo-Stick can be 'better' than something more rigid. In the OP's case I believe the goal is to rigidly bond the outer of a 'flexible link' to a bracket that uses a form or ferrule that was previously attached somehow. Therefore, a rigid bond should be fine and as both steel (coil outer) and brass are very compatible with JB weld, I think as long as the surfaces are (chemically) clean and even just enough applied to both surfaces to fill the void as completely as possible, you would be hard pressed to get the two apart without destroying both (that is my ultimate test). ;-) Cheers, T i m |
#32
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
On 13/06/18 09:22, newshound wrote:
On 12/06/2018 20:30, wrote: Hi all I have taken some photos and tried to upload them to a public album (hopefully not done this for ages). They show the fittings and particularly the brass fitting I need to connect the sheath to. Hopefully this works https://photos.app.goo.gl/L44RinHPY2v2UeEbA I have tried some searching but can only find examples of soldering the fitting to the wire rather than the sheath to the fitting.Â* They seemed to use "silver solder" which I assume is not the same as plumbing solder Thanks Lee. Very helpful. "Silver soldering" is done at red heat, I think even "soft soldering" (i.e. plumbing / electrical) will deform the plastic however careful you are. I would go for epoxy: abrade and degrease the parts first. Someone has already suggested this. --- This email has been checked for viruses by Avast antivirus software. https://www.avast.com/antivirus Silver soldreing is done at a bit less than red heat, but yes, its way above 'soft solder' -- "And if the blind lead the blind, both shall fall into the ditch". Gospel of St. Mathew 15:14 |
#33
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
On 13/06/2018 19:08, The Natural Philosopher wrote:
On 13/06/18 09:22, newshound wrote: On 12/06/2018 20:30, wrote: Hi all I have taken some photos and tried to upload them to a public album (hopefully not done this for ages). They show the fittings and particularly the brass fitting I need to connect the sheath to. Hopefully this works https://photos.app.goo.gl/L44RinHPY2v2UeEbA I have tried some searching but can only find examples of soldering the fitting to the wire rather than the sheath to the fitting.Â* They seemed to use "silver solder" which I assume is not the same as plumbing solder Thanks Lee. Very helpful. "Silver soldering" is done at red heat, I think even "soft soldering" (i.e. plumbing / electrical) will deform the plastic however careful you are. I would go for epoxy: abrade and degrease the parts first. Someone has already suggested this. --- This email has been checked for viruses by Avast antivirus software. https://www.avast.com/antivirus Silver soldreing is done at a bit less than red heat, but yes, its way above 'soft solder' Easy Flo No 2 is one of the lowest, 608 to 617 C, which is very dark red. I reckon you need to get your work up to near enough 700 to be practicable, which is dull red. Not bright, I agree, but clearly visible in a dark-ish workshop. |
#34
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
In article ,
Tjoepstil wrote: Bowden cables typically only work in tension so there is no need to fix the outer to the ferrule Do try and keep up. -- *I'm planning to be spontaneous tomorrow * Dave Plowman London SW To e-mail, change noise into sound. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
How does my new oven work? How did my old oven work? | Home Repair | |||
What does this do? How does this remote contorl extender work? | Electronics Repair | |||
Online retailers give you the best selection of mens work uniforms.Whether you're looking for bib overalls or the full ensemble in workingapparel, you can find them through online retailers and at the right place.Work wear does not just provide quali | UK diy | |||
Online retailers give you the best selection of mens work uniforms.Whether you're looking for bib overalls or the full ensemble in workingapparel, you can find them through online retailers and at the right place.Work wear does not just provide quali | Home Repair | |||
Electrical work - would inspector check previously done work? | Home Repair |