Can somebody help me.
I have a combi boiler, when I run a bath the water is only hot if I keep the
tap turned low, (minimal pressure)
If I open the tap fully the water is tepid.
However the kitchen sink does not have this problem.
My bathroom and kitchen are on the same level (next to each other)
I am wanting to fit a mixer tap shower but need to resolve this problem first.
Is this a blockage? In the pipe, however no pressure is lost,.
Or is it because the taps on the bath have a wider outlet flow than the
kitchen sink, therefore the boiler cant heat the water up fast enough?
Please can someone advise.
Thank you

--
for full context, visit https://www.homeownershub.com/uk-diy...s-1280114-.htm


  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 3,237
Default Hot water problems

Ciaran flanagan m
wrote:

Can somebody help me.
I have a combi boiler, when I run a bath the water is only hot if I keep the
tap turned low, (minimal pressure)
If I open the tap fully the water is tepid.
However the kitchen sink does not have this problem.
My bathroom and kitchen are on the same level (next to each other)
I am wanting to fit a mixer tap shower but need to resolve this problem first.
Is this a blockage? In the pipe, however no pressure is lost,.
Or is it because the taps on the bath have a wider outlet flow than the
kitchen sink, therefore the boiler can't heat the water up fast enough?
Please can someone advise.
Thank you


Most likely your last theory is right, what happens if you adjust the
bath tap to about the same flow as the kitchen tap? Test by timing
filling a bucket if not sure. Should still be enough for a reasonable
shower. What power is the combi?

Another possibility if the amount of hot water seems less than it used
to be is a problem with the valve switching off the central heating when
hot water is demanded, but there may well not be anything wrong.


--

Roger Hayter
  #3   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 25,191
Default Hot water problems

On 07/04/2018 19:44, Ciaran flanagan wrote:

Can somebody help me.
I have a combi boiler, when I run a bath the water is only hot if I keep
the
tap turned low, (minimal pressure)
If I open the tap fully the water is tepid.
However the kitchen sink does not have this problem. My bathroom and
kitchen are on the same level (next to each other) I am wanting to fit a
mixer tap shower but need to resolve this problem first. Is this a
blockage? In the pipe, however no pressure is lost,.
Or is it because the taps on the bath have a wider outlet flow than the
kitchen sink, therefore the boiler cant heat the water up fast enough?


Yup, that is likely the case - you can't change the basic laws of
physics. The boiler only has enough power to heat a certain amount of
water per minute to a usable temperature. If you pull water through it
faster than that, the temperature will have to fall. If the water starts
out colder (say in winter) then again you will have accept a lower
maximum flow rate if you want the water as the same temperature as in
summer.

Now if you are saying that it used to be better, then its possible that
the boiler is not working as well as it did before. It might be for
example that the secondary heat exchanger that heats the hot water is
partially blocked (lime-scale etc). That could reduce the maximum rate
of heat transfer.

To work out what is actually happening you will need to do some tests
and some sums. Firstly measure the temperature of the cold water, and
also of what you consider to be "hot enough" on the hot water. Then work
out the flow rates you can get from the various taps in litres per min.
After that all you need know is the specific heat capacity of water
(about 4200 J/kg/c) and the power of the boiler.

So for example, say the mains cold is coming in a 7 degrees C, and you
want it heated to 45 degrees. That's a 38 deg change in temperature. Say
you have 24kW boiler (and lets assume that is the actual heat output to
the water and not its input gas rate (which will be a bit higher)). 24kW
is 24,000 Joules per second. So in a minute that gives 60 x 24,000 =
1,440,000 J of energy available.

Now just divide that by the temperature rise, and the SHC of water:

1,440,000 / 37 / 4200 = 9.25 kg

So that means the maximum flow rate is 9.25L (since 1L of water is 1kg)
per minute. Plenty for a good shower, but could take 10 to 15 mins to
fill a bath.

If you turn the tap on hard and take 15 lpm, it won't be 45 degrees any
more. (not some boilers actually include a flow regulator to keep the
output water temp as the requested level - however many don't. You can
achieve much the same thing by throttling the flow rate at the bath tap
with its service valve if it has one)





--
Cheers,

John.

/================================================== ===============\
| Internode Ltd - http://www.internode.co.uk |
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\================================================= ================/
  #4   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 4,120
Default Hot water problems

On 07/04/2018 20:23, Roger Hayter wrote:
Ciaran flanagancaedfaa9ed1216d60ef78a6f660f5f85_12720@ex ample.com
wrote:

Can somebody help me.
I have a combi boiler, when I run a bath the water is only hot if I keep the
tap turned low, (minimal pressure)
If I open the tap fully the water is tepid.
However the kitchen sink does not have this problem.
My bathroom and kitchen are on the same level (next to each other)
I am wanting to fit a mixer tap shower but need to resolve this problem first.
Is this a blockage? In the pipe, however no pressure is lost,.
Or is it because the taps on the bath have a wider outlet flow than the
kitchen sink, therefore the boiler can't heat the water up fast enough?
Please can someone advise.
Thank you


Most likely your last theory is right, what happens if you adjust the
bath tap to about the same flow as the kitchen tap? Test by timing
filling a bucket if not sure. Should still be enough for a reasonable
shower. What power is the combi?

Another possibility if the amount of hot water seems less than it used
to be is a problem with the valve switching off the central heating when
hot water is demanded, but there may well not be anything wrong.



Wot he sed. Make sure you're comparing apples with apples. If you can
really get a much higher flow rate of properly hot water from the
kitchen sink than from the bath, there's something very odd going on.

Don't forget that the incoming cold water is much colder this time of
year than in the summer, so the boiler has a lot more work to do to make
it hot - limiting the rate at which it can produce hot water.
--
Cheers,
Roger
____________
Please reply to Newsgroup. Whilst email address is valid, it is seldom
checked.
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Choosing a HOT WATER RECIRCULATOR for QUICK HOT WATER DELIVERY or for HOT WATER ON D'MAND is now a whole lot easier. [email protected] Home Repair 22 June 7th 06 01:09 AM
water cooler, water coolers, water dispenser, water dispensers,bottleless water cooler,bottleless water coolers,bottleless water dispenser,bottleless water dispensers water coolers UK diy 3 January 5th 06 08:23 PM
Hot Water Heater not making enough hot water -- Ringo Langly Home Repair 20 March 6th 05 03:38 AM
Circulating hot water vs two hot water heaters [email protected] Home Ownership 10 March 3rd 05 06:17 AM
hot water recirculator, instant hot water but not a water heating unit, saves water, gas, time, money HeatMan Home Repair 0 August 24th 03 12:26 PM


All times are GMT +1. The time now is 11:31 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"