#1
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
would there be any regulations i'd be breaking if i fitted a german shuko
style 2 pin with side earth strip socket in my house? i have a german pinball machine which still has the molded on right angle shuko plug on it's power lead, inside it also has a german shuko power point for the engineers lamp to plug into (that one is bakalite and non earthed, machine was made in 1976, so not that old), But i'd like to keep the origional lead... just to emphasize more that it's a german machine if that makes sense Basicaly all i'd do is get a single outlet shuko socket, if possible a switched one, and mount it next to the double 13 amp uk sockets, i wouldent usually even give this kind of thing a second thought, i'd put one in... better than using an adaptor or the easy solution which i know is to change the power lead to a uk version. but we are going to have one of those bods from warm front come round and assess how much insulation we need to have added (stair celing area is totaly open to the roof and has no insulation at all) and i can just imagine him noticing the shuko socket and getting arsey about it and putting on his report that i have illegal sockets in the house or something like that. |
#2
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
"gazz" wrote in message ... would there be any regulations i'd be breaking if i fitted a german shuko style 2 pin with side earth strip socket in my house? i have a german pinball machine which still has the molded on right angle shuko plug on it's power lead, inside it also has a german shuko power point for the engineers lamp to plug into (that one is bakalite and non earthed, machine was made in 1976, so not that old), But i'd like to keep the origional lead... just to emphasize more that it's a german machine if that makes sense Basicaly all i'd do is get a single outlet shuko socket, if possible a switched one, and mount it next to the double 13 amp uk sockets, i wouldent usually even give this kind of thing a second thought, i'd put one in... better than using an adaptor or the easy solution which i know is to change the power lead to a uk version. but we are going to have one of those bods from warm front come round and assess how much insulation we need to have added (stair celing area is totaly open to the roof and has no insulation at all) and i can just imagine him noticing the shuko socket and getting arsey about it and putting on his report that i have illegal sockets in the house or something like that. The Warm front "engineers" will not notice nor care about your electrical installation in this case. Adam |
#3
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
In article ,
"gazz" writes: would there be any regulations i'd be breaking if i fitted a german shuko style 2 pin with side earth strip socket in my house? Yes - it's not shuttered. i have a german pinball machine which still has the molded on right angle shuko plug on it's power lead, inside it also has a german shuko power point for the engineers lamp to plug into (that one is bakalite and non earthed, machine was made in 1976, so not that old), But i'd like to keep the origional lead... just to emphasize more that it's a german machine if that makes sense Basicaly all i'd do is get a single outlet shuko socket, if possible a switched one, and mount it next to the double 13 amp uk sockets, I haven't seen a switched one, and it would need fusing at 13A or a 16A MCB. Just buy a travel adaptor. i wouldent usually even give this kind of thing a second thought, i'd put one in... better than using an adaptor or the easy solution which i know is to change the power lead to a uk version. The adaptor will have a fuse in it. -- Andrew Gabriel [email address is not usable -- followup in the newsgroup] |
#4
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
"gazz" wrote in message ... would there be any regulations i'd be breaking if i fitted a german shuko style 2 pin with side earth strip socket in my house? Who would know or even care? but we are going to have one of those bods from warm front come round and assess how much insulation we need Wht has that got to do with a socket? and i can just imagine him noticing the shuko socket and getting arsey about it and putting on his report that i have illegal sockets in the house or something like that. Are you genuinely thick? You certainly come across that way. Why don't you hand yourself in at the nearest police station! |
#5
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
On Sat, 1 Nov 2008 20:12:16 -0000, "gazz" wrote:
i have a german pinball machine which still has the molded on right angle shuko plug on it's power lead, inside it also has a german shuko power point for the engineers lamp to plug into (that one is bakalite and non earthed, machine was made in 1976, so not that old), But i'd like to keep the origional lead... just to emphasize more that it's a german machine if that makes sense http://cpc.farnell.com/PL01350/elect...=pro-elec-9680 |
#6
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
"gazz" wrote:
would there be any regulations i'd be breaking if i fitted a german shuko style 2 pin with side earth strip socket in my house? i have a german pinball machine which still has the molded on right angle shuko plug on it's power lead, inside it also has a german shuko power point for the engineers lamp to plug into (that one is bakalite and non earthed, machine was made in 1976, so not that old), But i'd like to keep the origional lead... just to emphasize more that it's a german machine if that makes sense Basicaly all i'd do is get a single outlet shuko socket, if possible a switched one, and mount it next to the double 13 amp uk sockets, i wouldent usually even give this kind of thing a second thought, i'd put one in... better than using an adaptor or the easy solution which i know is to change the power lead to a uk version. but we are going to have one of those bods from warm front come round and assess how much insulation we need to have added (stair celing area is totaly open to the roof and has no insulation at all) and i can just imagine him noticing the shuko socket and getting arsey about it and putting on his report that i have illegal sockets in the house or something like that. I have a 3-way Euro extension lead that I bought in Spain. Obviously, it came with a lead that had a Euro plug on it. All I did was cut off the plug and replace it with a UK 13A plug. I can now plug in up to three appliances with Euro plugs on them - I own several. I feel sure that you could get these extension leads here in the UK. |
#7
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
"Tim" wrote in message ... "gazz" wrote in message ... would there be any regulations i'd be breaking if i fitted a german shuko style 2 pin with side earth strip socket in my house? Who would know or even care? official people who like to **** stir, come to do one job, nose around and report the things they find wrong whilst in your house to the authorities? but we are going to have one of those bods from warm front come round and assess how much insulation we need Wht has that got to do with a socket? if it's not allowed to be used in england, then it's like having a gas cooker connected with a length of rubber hose pushed onto a 1920's gas tap, and i can just imagine him noticing the shuko socket and getting arsey about it and putting on his report that i have illegal sockets in the house or something like that. Are you genuinely thick? You certainly come across that way. Why don't you hand yourself in at the nearest police station! course im thick, or i wouldent be asking questions here would i we used to be allowed to do pretty much what we likes to our own houses at one time, nowadays your not even allowed to put a patio down without asking permision, if we want to add a new ring main, we have to get it put in by a certified bod with all the costs involved, they wont empty your bin if you put the wrong items in it, fill it too full or put it out before it's supposed to be put out, i know if i added something to the gas supply that wasnt allowed, and it was seen or reported to an official, they'd come round and cap the supply off, i just wanted to check what the situation was with adding a german socket to a uk house mains system, easy enough to shutter the shuko socket if needed, a brat proof insert, you have to twist the plug as you insert it to open the shutters, |
#8
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
On Sat, 1 Nov 2008 20:12:16 -0000 someone who may be "gazz"
wrote this:- would there be any regulations i'd be breaking if i fitted a german shuko style 2 pin with side earth strip socket in my house? Yes. Such a socket does not maintain polarity, which means it falls foul of the UK Wiring Regulations. However, the Wiring Regulations do allow "non-standard" equipment/installations on the say-so of a suitably qualified electrical engineer, provided it provides an equivalent level of safety. You would need to be prepared to argue this out in court should something happen and you would be arguing this out with a ****** who knows bugger all about electrical systems, a lawyer. Some may well think that you will also fall foul of some Mickey Mouse UK laws, like "The Plugs and Sockets etc. (Safety) Regulations 1994". However you can argue, to the same ******, that this stuff should never have been passed by the rogues' gallery at Westminster as it is in conflict with the Single European Act of 1986 and subsequent laws. I like the Single European Act as both the current and previous Tory governments dare not speak against it, as it was pushed through by the mad Woman of Finchley. Your choice. i have a german pinball machine which still has the molded on right angle shuko plug on it's power lead, inside it also has a german shuko power point for the engineers lamp to plug into (that one is bakalite and non earthed, machine was made in 1976, so not that old), But i'd like to keep the origional lead... just to emphasize more that it's a german machine if that makes sense Shuko sockets are **** poor compared to the BS 1363 design. However, in this case I would consider it worth keeping the primitive plug as an illustration of how poor other electrical wiring systems are. The concept of RCDs for all socket outlets is ridiculous, but in the case of a Shuko socket it is a good idea to fit one. but we are going to have one of those bods from warm front come round and assess how much insulation we need to have added (stair celing area is totaly open to the roof and has no insulation at all) and i can just imagine him noticing the shuko socket and getting arsey about it and putting on his report that i have illegal sockets in the house or something like that. I doubt it. If you are worried then put the offensive socket a little to the side of the BS 1363 sockets and disguise the Shuko socket in some way for the visit. Use your initiative to work out the disguise, don't expect to be spoon fed. -- David Hansen, Edinburgh I will *always* explain revoked encryption keys, unless RIP prevents me http://www.opsi.gov.uk/acts/acts2000/00023--e.htm#54 |
#9
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
"gazz" wrote in message ... would there be any regulations i'd be breaking if i fitted a german shuko style 2 pin with side earth strip socket in my house? i have a german pinball machine which still has the molded on right angle shuko plug on it's power lead, inside it also has a german shuko power point for the engineers lamp to plug into (that one is bakalite and non earthed, machine was made in 1976, so not that old), But i'd like to keep the origional lead... just to emphasize more that it's a german machine if that makes sense Basicaly all i'd do is get a single outlet shuko socket, if possible a switched one, and mount it next to the double 13 amp uk sockets, i wouldent usually even give this kind of thing a second thought, i'd put one in... better than using an adaptor or the easy solution which i know is to change the power lead to a uk version. but we are going to have one of those bods from warm front come round and assess how much insulation we need to have added (stair celing area is totaly open to the roof and has no insulation at all) and i can just imagine him noticing the shuko socket and getting arsey about it and putting on his report that i have illegal sockets in the house or something like that. ROFLMAO !!!!!!!!!!!!!!!!!!!!!!!!!!! A Euro adapter costs about 3 quid at most. Why the hell would you want to start messing about with the house wiring when the adapter is cheaper to buy than the actual socket. Remember this advice well. Put your brain into gear before picking up the tools. An hour of useful thought is much better than an hour of useless humiliation. |
#10
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
In message , BigWallop
writes "gazz" wrote in message ... would there be any regulations i'd be breaking if i fitted a german shuko style 2 pin with side earth strip socket in my house? .... ... i wouldent usually even give this kind of thing a second thought, i'd put one in... better than using an adaptor or the easy solution which i know is to change the power lead to a uk version. but we are going to have one of those bods from warm front come round and assess how much insulation we need to have added (stair celing area is totaly open to the roof and has no insulation at all) and i can just imagine him noticing the shuko socket and getting arsey about it and putting on his report that i have illegal sockets in the house or something like that. ROFLMAO !!!!!!!!!!!!!!!!!!!!!!!!!!! A Euro adapter costs about 3 quid at most. Why the hell would you want to start messing about with the house wiring when the adapter is cheaper to buy than the actual socket. Remember this advice well. Put your brain into gear before picking up the tools. An hour of useful thought is much better than an hour of useless humiliation. Unfortunately, it's become common practice here of late posting before thinking or asking the actual relevant authority has become the norm like the eejit who posted a while back asking how to remove a sticker from his car rear window - much stupid discussion ensued, then he actually tried removing it and it just peeled off The ask first, think later culture is well and truly here -- geoff |
#11
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
geoff wrote:
In message , BigWallop writes "gazz" wrote in message ... would there be any regulations i'd be breaking if i fitted a german shuko style 2 pin with side earth strip socket in my house? ... ... i wouldent usually even give this kind of thing a second thought, i'd put one in... better than using an adaptor or the easy solution which i know is to change the power lead to a uk version. but we are going to have one of those bods from warm front come round and assess how much insulation we need to have added (stair celing area is totaly open to the roof and has no insulation at all) and i can just imagine him noticing the shuko socket and getting arsey about it and putting on his report that i have illegal sockets in the house or something like that. ROFLMAO !!!!!!!!!!!!!!!!!!!!!!!!!!! A Euro adapter costs about 3 quid at most. Why the hell would you want to start messing about with the house wiring when the adapter is cheaper to buy than the actual socket. Remember this advice well. Put your brain into gear before picking up the tools. An hour of useful thought is much better than an hour of useless humiliation. Unfortunately, it's become common practice here of late posting before thinking or asking the actual relevant authority has become the norm like the eejit who posted a while back asking how to remove a sticker from his car rear window - much stupid discussion ensued, then he actually tried removing it and it just peeled off The ask first, think later culture is well and truly here but sometimes asking first is better than FUBAR then asking how to put it back together -- Kevin R Reply address works |
#12
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
In message , Kevin
writes geoff wrote: In message , BigWallop writes "gazz" wrote in message ... would there be any regulations i'd be breaking if i fitted a german shuko style 2 pin with side earth strip socket in my house? ... ... i wouldent usually even give this kind of thing a second thought, i'd put one in... better than using an adaptor or the easy solution which i know is to change the power lead to a uk version. but we are going to have one of those bods from warm front come round and assess how much insulation we need to have added (stair celing area is totaly open to the roof and has no insulation at all) and i can just imagine him noticing the shuko socket and getting arsey about it and putting on his report that i have illegal sockets in the house or something like that. ROFLMAO !!!!!!!!!!!!!!!!!!!!!!!!!!! A Euro adapter costs about 3 quid at most. Why the hell would you want to start messing about with the house wiring when the adapter is cheaper to buy than the actual socket. Remember this advice well. Put your brain into gear before picking up the tools. An hour of useful thought is much better than an hour of useless humiliation. Unfortunately, it's become common practice here of late posting before thinking or asking the actual relevant authority has become the norm like the eejit who posted a while back asking how to remove a sticker from his car rear window - much stupid discussion ensued, then he actually tried removing it and it just peeled off The ask first, think later culture is well and truly here but sometimes asking first is better than FUBAR then asking how to put it back together I'm not talking about that I'm on about posting first, thinking later -- geoff |
#13
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
"gazz" wrote in message ... would there be any regulations i'd be breaking if i fitted a german shuko style 2 pin with side earth strip socket in my house? You may well be breaking some regulations depending on how you achieve it, but in principle it is perfectly possible to fit Shuko sockets in UK. Some hotels do. Have a look at the "Use of Guidance" section of the Approved Document Part P of the Building Regs which says you can use: ..... an alternative national technical specification of any state which is a contracting party to the European Economic Area which, in use, is equivalent........ Convincing the Building Control Officer with your equivalent to the MWC in German is another matter! As others have said, there are simpler ways though. BruceB |
#14
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
David Hansen wrote:
Shuko sockets are **** poor compared to the BS 1363 design. However, in this case I would consider it worth keeping the primitive plug as an illustration of how poor other electrical wiring systems are. The concept of RCDs for all socket outlets is ridiculous, but in the case of a Shuko socket it is a good idea to fit one. Not wishing to start a fight here, but could someone elaborate on why the Shuko socket/plug is **** poor compared to ours? I've also heard it said that our overall domestic electrical system is far better than the European system, which is why we haven't harmonised. Could someone elaborate on that? -- Dave - The Medway Handyman www.medwayhandyman.co.uk |
#15
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
On Sun, 02 Nov 2008 09:46:19 GMT someone who may be "The Medway
Handyman" wrote this:- Not wishing to start a fight here, but could someone elaborate on why the Shuko socket/plug is **** poor compared to ours? Does not maintain polarity. Unfused. Primitive earth connection. Versions without an earth connection were (perhaps still are) available, which leads to equipment needing to be earthed being plugged into sockets without an earth connection. Shuttering not standard. That doesn't mean everyone dies in places with this sort of equipment, but it is less safe than the UK designs. I've also heard it said that our overall domestic electrical system is far better than the European system, which is why we haven't harmonised. Could someone elaborate on that? Well the UK is in Europe (both Europe and the EU, which are two separate things). There is also no one type of electrical socket and wiring in the rest of Europe. However, two excellent features of the UK approach are ring final circuits and BC lampholders. The former allows anything portable to be plugged into any socket without much concern. It is far more flexible and just works. The latter is diminishing with new types of lamp and a desire amongst some manufacturers to reduce their costs, but not the prices they charge, by using ES lampholders. The main poor features of ES lampholders are the way the lamp unscrews (due to heat) and the possibility of wiring the live to the threaded bit (which is bound to happen in a system with unpolarised plugs and sockets). -- David Hansen, Edinburgh I will *always* explain revoked encryption keys, unless RIP prevents me http://www.opsi.gov.uk/acts/acts2000/00023--e.htm#54 |
#16
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
In article ,
gazz wrote: would there be any regulations i'd be breaking if i fitted a german shuko style 2 pin with side earth strip socket in my house? Almost certainly. i have a german pinball machine which still has the molded on right angle shuko plug on it's power lead, inside it also has a german shuko power point for the engineers lamp to plug into (that one is bakalite and non earthed, machine was made in 1976, so not that old), But i'd like to keep the origional lead... just to emphasize more that it's a german machine if that makes sense Basicaly all i'd do is get a single outlet shuko socket, if possible a switched one, and mount it next to the double 13 amp uk sockets, i wouldent usually even give this kind of thing a second thought, i'd put one in... better than using an adaptor or the easy solution which i know is to change the power lead to a uk version. Given the size of a pinball machine would an adaptor lead make that much difference? but we are going to have one of those bods from warm front come round and assess how much insulation we need to have added (stair celing area is totaly open to the roof and has no insulation at all) and i can just imagine him noticing the shuko socket and getting arsey about it and putting on his report that i have illegal sockets in the house or something like that. I doubt he'd be qualified in this sort of thing let alone interested. If I were to do as you want I'd feed it via its own FCU/RCD unit. Like this:- http://www.tlc-direct.co.uk/Main_Ind...e_2/index.html -- *If a pig loses its voice, is it disgruntled? Dave Plowman London SW To e-mail, change noise into sound. |
#17
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
David Hansen wrote:
On Sun, 02 Nov 2008 09:46:19 GMT someone who may be "The Medway Handyman" wrote this:- Not wishing to start a fight here, but could someone elaborate on why the Shuko socket/plug is **** poor compared to ours? Does not maintain polarity. Unfused. Primitive earth connection. Versions without an earth connection were (perhaps still are) available, which leads to equipment needing to be earthed being plugged into sockets without an earth connection. Shuttering not standard. That doesn't mean everyone dies in places with this sort of equipment, but it is less safe than the UK designs. I've also heard it said that our overall domestic electrical system is far better than the European system, which is why we haven't harmonised. Could someone elaborate on that? Well the UK is in Europe (both Europe and the EU, which are two separate things). There is also no one type of electrical socket and wiring in the rest of Europe. However, two excellent features of the UK approach are ring final circuits and BC lampholders. The former allows anything portable to be plugged into any socket without much concern. It is far more flexible and just works. The latter is diminishing with new types of lamp and a desire amongst some manufacturers to reduce their costs, but not the prices they charge, by using ES lampholders. The main poor features of ES lampholders are the way the lamp unscrews (due to heat) and the possibility of wiring the live to the threaded bit (which is bound to happen in a system with unpolarised plugs and sockets). Sorry, is that the BC lampholder which allows two live connections to be touched? (I accept that ES also suffers this possibility.) I had been rather hoping that one positive aspect of CFLs (and other efficient lamp technologies) might have been widespread use of, say, SES which is much more difficult to stick my fingers into. -- Rod Hypothyroidism is a seriously debilitating condition with an insidious onset. Although common it frequently goes undiagnosed. www.thyromind.info www.thyroiduk.org www.altsupportthyroid.org |
#18
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
BruceB wrote:
Have a look at the "Use of Guidance" section of the Approved Document Part P of the Building Regs which says you can use: ..... an alternative national technical specification of any state which is a contracting party to the European Economic Area which, in use, is equivalent........ Convincing the Building Control Officer with your equivalent to the MWC in German is another matter! Who would counter with the observation that one can't pick-&-mix parts of an electrical installation with others; you either use the German standard in its entirety, or stick with the British one. He may also proffer the opinion that the use of such wording is a standard preamble to all the Approved Documents, and is merely a sop to the courts to show that the guidance meets all the relevant 'single-market' regulations. And then go tell you that the addition of a socket-outlet that is the extension of an existing ring or radial circuit is not notifiable (unless it is in a kitchen or special location). -- Hugo Nebula "If no-one on the internet wants a piece of this, just how far from the pack have you strayed"? |
#19
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
geoff wrote:
In message , Kevin writes geoff wrote: In message , BigWallop writes "gazz" wrote in message ... would there be any regulations i'd be breaking if i fitted a german shuko style 2 pin with side earth strip socket in my house? ... ... i wouldent usually even give this kind of thing a second thought, i'd put one in... better than using an adaptor or the easy solution which i know is to change the power lead to a uk version. but we are going to have one of those bods from warm front come round and assess how much insulation we need to have added (stair celing area is totaly open to the roof and has no insulation at all) and i can just imagine him noticing the shuko socket and getting arsey about it and putting on his report that i have illegal sockets in the house or something like that. ROFLMAO !!!!!!!!!!!!!!!!!!!!!!!!!!! A Euro adapter costs about 3 quid at most. Why the hell would you want to start messing about with the house wiring when the adapter is cheaper to buy than the actual socket. Remember this advice well. Put your brain into gear before picking up the tools. An hour of useful thought is much better than an hour of useless humiliation. Unfortunately, it's become common practice here of late posting before thinking or asking the actual relevant authority has become the norm like the eejit who posted a while back asking how to remove a sticker from his car rear window - much stupid discussion ensued, then he actually tried removing it and it just peeled off The ask first, think later culture is well and truly here but sometimes asking first is better than FUBAR then asking how to put it back together I'm not talking about that I'm on about posting first, thinking later that's exactly the same is it not???? -- Kevin R Reply address works |
#20
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
On Sun, 02 Nov 2008 10:01:41 +0000, David Hansen wrote:
Does not maintain polarity. Doesn't have to there is no such concept as "polarity" in the continental wiring system. You have two wires with 230v (nominal) between them niether is connected to earth. Unfused. Primitive earth connection. Versions without an earth connection were (perhaps still are) available, which leads to equipment needing to be earthed being plugged into sockets without an earth connection. Shuttering not standard. That doesn't mean everyone dies in places with this sort of equipment, but it is less safe than the UK designs. I've also heard it said that our overall domestic electrical system is far better than the European system, which is why we haven't harmonised. Could someone elaborate on that? Well the UK is in Europe (both Europe and the EU, which are two separate things). There is also no one type of electrical socket and wiring in the rest of Europe. However, two excellent features of the UK approach are ring final circuits and BC lampholders. The former allows anything portable to be plugged into any socket without much concern. It is far more flexible and just works. The latter is diminishing with new types of lamp and a desire amongst some manufacturers to reduce their costs, but not the prices they charge, by using ES lampholders. The main poor features of ES lampholders are the way the lamp unscrews (due to heat) and the possibility of wiring the live to the threaded bit (which is bound to happen in a system with unpolarised plugs and sockets). -- David Hansen, Edinburgh I will *always* explain revoked encryption keys, unless RIP prevents me http://www.opsi.gov.uk/acts/acts2000/00023--e.htm#54 -- Cheers Dave. |
#21
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
In article ,
Rod writes: Sorry, is that the BC lampholder which allows two live connections to be touched? (I accept that ES also suffers this possibility.) I had been rather hoping that one positive aspect of CFLs (and other efficient lamp technologies) might have been widespread use of, say, SES which is much more difficult to stick my fingers into. Whilst ES lampholders do seem to account for a number of electrocutions, BC lampholders don't seem to have caused a single one (in both cases, excluding faults). In practice, I suspect its too difficult to get a good enough connection between a finger and the pins, combined with less opportunity to do so in normal use. With ES lampholders, the main risk is gripping a bulb to insert/remove it, and being electrocuted by exposed metal of the lamp base. In most countries where it's used, it's not possible to guarantee the live connection is the tip, as live/neutral polarity isn't preserved into appliances. (In the UK, it is required that the tip is the live connection of an ES lampholder.) -- Andrew Gabriel [email address is not usable -- followup in the newsgroup] |
#22
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
In article et,
"Dave Liquorice" writes: On Sun, 02 Nov 2008 10:01:41 +0000, David Hansen wrote: Does not maintain polarity. Doesn't have to there is no such concept as "polarity" in the continental wiring system. You have two wires with 230v (nominal) between them niether is connected to earth. There are a few places like that (some Scandanavian countries derive 230V from 3-phase delta with one grounded leg, so 1 in 3 230V supplies have no neutral, and some areas of France and probably elsewhere still use IT earthing systems). However, the vast majority do have a grounded neutral, and polarity is preserved as far as the back of the socket outlet. With the socket outlets for the most part having no defined polarity (French/Belgium) or being reversible (Schuko), that is where it's lost. But given these sockets are used on supplies with no neutral (however few), it must be assumed by all appliances that both sides are phase connections. -- Andrew Gabriel [email address is not usable -- followup in the newsgroup] |
#23
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
On Sun, 02 Nov 2008 11:07:41 +0000 someone who may be Rod
wrote this:- The main poor features of ES lampholders are the way the lamp unscrews (due to heat) and the possibility of wiring the live to the threaded bit (which is bound to happen in a system with unpolarised plugs and sockets). Sorry, is that the BC lampholder which allows two live connections to be touched? (I accept that ES also suffers this possibility.) The issue is when the lamps are in place. When the lamp is in place in a BC lampholder it is not possible to touch any energised part. However, when the lamp is in place in an ES lampholder it may be possible to touch an energised part, particularly those with small fingers, or push a metal item such as a knitting needle onto an energised part. -- David Hansen, Edinburgh I will *always* explain revoked encryption keys, unless RIP prevents me http://www.opsi.gov.uk/acts/acts2000/00023--e.htm#54 |
#24
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
"The Medway Handyman" wrote in message om... David Hansen wrote: Shuko sockets are **** poor compared to the BS 1363 design. However, in this case I would consider it worth keeping the primitive plug as an illustration of how poor other electrical wiring systems are. The concept of RCDs for all socket outlets is ridiculous, but in the case of a Shuko socket it is a good idea to fit one. Not wishing to start a fight here, but could someone elaborate on why the Shuko socket/plug is **** poor compared to ours? i only lived in Germany when i was younger, but from what i remember, the shuko socket has full length wiper style contacts that give a much better connection to the plugs pins than the uk's end contacts, the shuko socket can do that as it doesn't need insulating strips like uk ones do (with the exception of the 2 pin flat plugs on double insulated appliances) we need the insulation strips as out socket is a flat plate, the shuko one is recessed, so it's impossible to tough the pins and you insert a shuko socket like you can on a uk one. the shuko socket and plugs are rated for 16 amps, uk 13 amps, to me that says something about the design of the uk ones... i know why, it's those little end contacts to stop electrocution if you insert an uninsulated pin plug whilst touching the pins, don't make contact with the live bit till the plug is practically all the way in. i read so many stories of people buying things like welders from Germany, they work fine over there on the 16 amp supply, but put a 13 amp plug on em and they pop the fuse each time you strike an arc... meaning the expense of installing a separate 16 amp supply and bulky blue socket just for the welder. yes you can plug the shuko plug in either way round, but in Europe the appliances are double pole switched, i.e. switch live and neutral, not like the uk with single pole switching, there is supposed to be no polarity on AC supplies, so why the need to insert the plug one way round only? the earth strips on shuko sockets... whats wrong with them? there's 2 of them to match the 2 earth strips on the plug, you get a good earth connection which ever way you plug in. I've never seen a non earthed shuko socket that could take an earthed plug. they do have 2 types of plug in Germany, the round 2 pin with earth strip 16 amp plug for appliances needing earth and full power, then you have the flat 2 pin plug (like a shaver plug) no earth on them as they are only fitted to 2 core wire connected to double insulated appliances... TV, videos' and the like. you can plug one of them into an earthed shuko socket, but you cant plug an earthed plug into a non earthed socket (only seen extension leads with the flat non earthed sockets) all shuko sockets have a recess that matches the plug's type, unlike a uk flat plate socket, The thing i liked about German extension leads... you could buy some with pin holes per socket, this is so you can plug in a single earthed plug, or 2 x flat non earthed plugs in a single socket, ideal for the hifi or tv/video/dvd/sat box extension. the flat non earthed plugs are for lower current appliances, 8 amps max i'd guess, but could be lower, afaik europe uses radial circuits, i certainly remember the breaker box in our house in Germany being massive (1985 time), had a breaker for almost every socket and light, tripping one would not plunge the whole house into darkness or shut everything off like it does over here. yes no fuses in the plugs, but hence the breakers for the sockets. i also liked how if you reach the end of the cord.. say hoovering, and tugged it a bit, you just pull the plug out the socket, over her you bend the damn thing up a bit, straining the wire like hell, I've also have a few times where I've gone to unplug a uk plug, and had the top come away from a failed screw thread, leaving exposed terminals, that's impossible to do with a shuko plug, the screw goes right through the plug and is at 90 degrees to the way you pull it out the socket, so will never come undone to expose live terminals whilst it is in the socket. so it seems the only thing to complain about with the German system is the lack of polarity, for which as mentioned the only thing that affects is a table lamp, if you are stupid enough to unscrew the bulb while it's still plugged in, whilst touching something earthed with one hand and reaching right down and touching the screw thread of the bulb whilst unscrewing it.... the rcd just trips when you do that anyway, Give me the shuko plugs and sockets anyday, |
#25
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
gazz coughed up some electrons that declared:
would there be any regulations i'd be breaking if i fitted a german shuko style 2 pin with side earth strip socket in my house? i have a german pinball machine which still has the molded on right angle shuko plug on it's power lead, inside it also has a german shuko power point for the engineers lamp to plug into (that one is bakalite and non earthed, machine was made in 1976, so not that old), But i'd like to keep the origional lead... just to emphasize more that it's a german machine if that makes sense Basicaly all i'd do is get a single outlet shuko socket, if possible a switched one, and mount it next to the double 13 amp uk sockets, i wouldent usually even give this kind of thing a second thought, i'd put one in... better than using an adaptor or the easy solution which i know is to change the power lead to a uk version. but we are going to have one of those bods from warm front come round and assess how much insulation we need to have added (stair celing area is totaly open to the roof and has no insulation at all) and i can just imagine him noticing the shuko socket and getting arsey about it and putting on his report that i have illegal sockets in the house or something like that. Personally, if you really want a fixed Shuko (as opposed to the very good suggestions here of using a travel adaptor or shuko-strip) I would install it off the end of a switched fused connection unit, fused correctly for the application. It'll be safe (as any shuko socket is), neat, switched and easy to de-install (replace FCU with 13A socket). Cheers Tim |
#26
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
"Hugo Nebula" abuse@localhost wrote in message ... Who would counter with the observation that one can't pick-&-mix parts of an electrical installation with others; you either use the German standard in its entirety, or stick with the British one. He might counter with that but he would not be able to cite a regulation that says so in those terms. There appear to be examples of mixed installations in UK that have been accepted as discussed in this thread: http://www.theiet.org/Forums/Forum/m...threadid=25916 Regards BruceB |
#27
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
gazz wrote:
"The Medway Handyman" wrote in message om... David Hansen wrote: yes you can plug the shuko plug in either way round, but in Europe the appliances are double pole switched, i.e. switch live and neutral, not like the uk with single pole switching, there is supposed to be no polarity on AC supplies, so why the need to insert the plug one way round only? where did you get that idea from? AC has a Live cable which kills and a neutral that does not, so yes it does mater which way round its plugged in, usually over here only the live is fused so if you plug in a piece of equipment the wrong way round yes it will work but under a fault condition the fuse could blow on the neutral and the current still could flow between Live and Earth |
#28
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
"Tim S" wrote in message ... Personally, if you really want a fixed Shuko (as opposed to the very good suggestions here of using a travel adaptor or shuko-strip) I would install it off the end of a switched fused connection unit, fused correctly for the application. that's what i'll do, have it on a travel adaptor at the moment, but dont like it, sticks out a lot, looks ugly, and after a few days the 2 plugs seem to be hanging from the sockets... prolly me catching the wire slightly. the sockets in the games room are all at chest of shoulder height, so the machines can be switched on and off easily and we dont leave one of them on by mistake as would be the case if we had to crawl under the desks/machines to get at a floor level socket (im prolly breaking regs having the 13 amp sockets where i do anyway) just it would look a hell of a lot neater to have a proper wall mounted shuko socket or 2 next to the 13 amp sockets, as i plan to get another pinball machine sometime, and the best ones come from germany, also just noticed the travel adaptor i have in use dosent earth the shuko socket, so i may as well have stuck a screwdriver in the earth hole of the 13 amp socket to open the shutters, and jammed the shuko's pins in the power holes. |
#29
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
Andrew Gabriel wrote:
In article , Rod writes: Sorry, is that the BC lampholder which allows two live connections to be touched? (I accept that ES also suffers this possibility.) I had been rather hoping that one positive aspect of CFLs (and other efficient lamp technologies) might have been widespread use of, say, SES which is much more difficult to stick my fingers into. Whilst ES lampholders do seem to account for a number of electrocutions, BC lampholders don't seem to have caused a single one (in both cases, excluding faults). In practice, I suspect its too difficult to get a good enough connection between a finger and the pins, combined with less opportunity to do so in normal use. With ES lampholders, the main risk is gripping a bulb to insert/remove it, and being electrocuted by exposed metal of the lamp base. In most countries where it's used, it's not possible to guarantee the live connection is the tip, as live/neutral polarity isn't preserved into appliances. (In the UK, it is required that the tip is the live connection of an ES lampholder.) Thanks - I must admit surprise. I think the nearest to bad outcomes I have had occurred when the glass bulb separated from the metal base or when the bulb actually broke leaving spikes of filament support. I doubt there is much difference between ES and BC in this specific regard - though one may be more likely than the other to separate like that. In fact, thinking about it, the best improvement might be to ensure double-pole switches are used. But I am probably missing something important... (Yes - I know that would play havoc with multi-way switching. :-) But would be feasible for table and standard lamps.) -- Rod Hypothyroidism is a seriously debilitating condition with an insidious onset. Although common it frequently goes undiagnosed. www.thyromind.info www.thyroiduk.org www.altsupportthyroid.org |
#30
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
"David Hansen" wrote in message ... The issue is when the lamps are in place. When the lamp is in place in a BC lampholder it is not possible to touch any energised part. However, when the lamp is in place in an ES lampholder it may be possible to touch an energised part, particularly those with small fingers, or push a metal item such as a knitting needle onto an energised part. we all gotta learn not to poke around in things we dont understand sometime done we, it's all very well making things brat proof, but surely it's better to teach the brats not to try inserting things into sockets/bulb holders, i learnt not to put my fingers into a street lamp that had it's cover missing, wont be doing that again and it taught me to be a bit more respectfull of electricity.... think that's the word here, too many people fear electricity, give it a bit of respect and you'll get on fine, |
#31
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
On Sun, 2 Nov 2008 14:00:18 -0000, "gazz" wrote:
"The Medway Handyman" wrote in message . com... David Hansen wrote: Shuko sockets are **** poor compared to the BS 1363 design. However, in this case I would consider it worth keeping the primitive plug as an illustration of how poor other electrical wiring systems are. The concept of RCDs for all socket outlets is ridiculous, but in the case of a Shuko socket it is a good idea to fit one. Not wishing to start a fight here, but could someone elaborate on why the Shuko socket/plug is **** poor compared to ours? i only lived in Germany when i was younger, but from what i remember, the shuko socket has full length wiper style contacts that give a much better connection to the plugs pins than the uk's end contacts, The "Schuko" comes in many forms both earthed and not earthed. In the house we had in Germany it was wired with a mixture of both. The same plug fitted both. the shuko socket can do that as it doesn't need insulating strips like uk ones do (with the exception of the 2 pin flat plugs on double insulated appliances) we need the insulation strips as out socket is a flat plate, the shuko one is recessed, so it's impossible to tough the pins and you insert a shuko socket like you can on a uk one. Some are recessed but there are also flush mounting non-earthed variants which allow you to touch both pins when inserting them. the shuko socket and plugs are rated for 16 amps, uk 13 amps, to me that says something about the design of the uk ones... It says nothing other than you have forgotten the design voltage. Both plugs are essentially similar in current handling capacity. The Schuko is rated at 16A at 220V (3,520W) the BS1363 at 13A at 240V (3,120W). If anything the 13A plug/socket is more reliable at high currents. as the contact area is larger. The relatively high rating of the Schuko means it has to be a tight fit in the socket which makes it difficult for people with arthritic hands to plug them in properly or remove them. It is common to find Schuko plugs very loose in the sockets as they are not fully inserted. i read so many stories You shouldn't believe everything you read. yes you can plug the shuko plug in either way round, but in Europe the appliances are double pole switched, i.e. switch live and neutral, not like the uk with single pole switching, Appliances are switched identically in the UK and the rest of the EU. I've never seen a non earthed shuko socket that could take an earthed plug. They are very common. afaik europe uses radial circuits, i certainly remember the breaker box in our house in Germany being massive (1985 time), had a breaker for almost every socket and light, tripping one would not plunge the whole house into darkness or shut everything off like it does over here. It usually does plunge everything into darkness as lighting circuits are rarely wired one to each circuit breaker but as in the UK. Power sockets are individually fused or done in groups. i also liked how if you reach the end of the cord.. say hoovering, and tugged it a bit, you just pull the plug out the socket, over her you bend the damn thing up a bit, straining the wire like hell, It also creates far more cases where plugs get broken or damaged by furniture being pushed against them or people trip over the leads. I've also have a few times where I've gone to unplug a uk plug, and had the top come away from a failed screw thread, leaving exposed terminals, that's impossible to do with a shuko plug, But it's very easy to use the cable to pull it out (and often necessary given the shape of some Schuko plugs) and pull one conductor off in the process leaving you with an exposed live wire. |
#32
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
On Sun, 02 Nov 2008 11:07:41 +0000, Rod
wrote: Sorry, is that the BC lampholder which allows two live connections to be touched? No - there's only one 'live' terminal. -- Frank Erskine |
#33
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
gazz coughed up some electrons that declared:
"Tim S" wrote in message ... Personally, if you really want a fixed Shuko (as opposed to the very good suggestions here of using a travel adaptor or shuko-strip) I would install it off the end of a switched fused connection unit, fused correctly for the application. that's what i'll do, have it on a travel adaptor at the moment, but dont like it, sticks out a lot, looks ugly, and after a few days the 2 plugs seem to be hanging from the sockets... prolly me catching the wire slightly. the sockets in the games room are all at chest of shoulder height, so the machines can be switched on and off easily and we dont leave one of them on by mistake as would be the case if we had to crawl under the desks/machines to get at a floor level socket (im prolly breaking regs having the 13 amp sockets where i do anyway) just it would look a hell of a lot neater to have a proper wall mounted shuko socket or 2 next to the 13 amp sockets, as i plan to get another pinball machine sometime, and the best ones come from germany, also just noticed the travel adaptor i have in use dosent earth the shuko socket, so i may as well have stuck a screwdriver in the earth hole of the 13 amp socket to open the shutters, and jammed the shuko's pins in the power holes. I'll just add to that, if using a switched fused unit, make sure that it's a double pole switch, as the shuko is polarity-reversible (as pointed out by everyone else). That will avoid an edge case of you thinking you've shut it off, then fiddling inside your pinball machine and getting a nasty surprise. eg: http://www.screwfix.com/prods/93481/...-13A-DP-Sw-FCU You'd have unplugged the machine in this case, of course, but, well, you know... Cheers Tim |
#34
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
Frank Erskine wrote:
On Sun, 02 Nov 2008 11:07:41 +0000, Rod wrote: Sorry, is that the BC lampholder which allows two live connections to be touched? No - there's only one 'live' terminal. Two potentially live connections... -- Rod Hypothyroidism is a seriously debilitating condition with an insidious onset. Although common it frequently goes undiagnosed. www.thyromind.info www.thyroiduk.org www.altsupportthyroid.org |
#35
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
Tim S coughed up some electrons that declared:
I'll just add to that, if using a switched fused unit, make sure that it's a double pole switch, as the shuko is polarity-reversible (as pointed out by everyone else). That will avoid an edge case of you thinking you've shut it off, then fiddling inside your pinball machine and getting a nasty surprise. Sorry. Brain spasm. I need to get some coffee. The way I've written that is stupid. You are in control of the polarity up until the shuko socket so you can never get an unswitched phase to the machine even with a single pole switch. Mind you, technically "neutral" is to be considered "live" (oridinary people's "live" is actually called "phase" or "line"), and a DP switch will offer protection against odd supply or wiring faults that involve the neutral floating up to 240V above earth. Still reasonable advice to use a DP switch (or none at all), but for slightly different reasons to the way it appeared in the last post. Cheers Tim |
#36
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
On Sun, 2 Nov 2008 15:22:26 -0000 someone who may be "gazz"
wrote this:- i learnt not to put my fingers into a street lamp that had it's cover missing, wont be doing that again and it taught me to be a bit more respectfull of electricity.... My father learn't the same lesson when he put a metal knitting needle into a Shuko socket. -- David Hansen, Edinburgh I will *always* explain revoked encryption keys, unless RIP prevents me http://www.opsi.gov.uk/acts/acts2000/00023--e.htm#54 |
#37
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
On Sun, 2 Nov 2008 14:00:18 -0000 someone who may be "gazz"
wrote this:- I've never seen a non earthed shuko socket that could take an earthed plug. I have. -- David Hansen, Edinburgh I will *always* explain revoked encryption keys, unless RIP prevents me http://www.opsi.gov.uk/acts/acts2000/00023--e.htm#54 |
#38
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
Andrew Gabriel wrote:
With ES lampholders, the main risk is gripping a bulb to insert/remove it, and being electrocuted by exposed metal of the lamp base. In most countries where it's used, it's not possible to guarantee the live connection is the tip, as live/neutral polarity isn't preserved into appliances. (In the UK, it is required that the tip is the live connection of an ES lampholder.) But all the recent ES lampholders I've seen are designed so that the threaded part of the cap doesn't make contact until the lamp is screwed almost fully home and the skirt extends just beyond the cap making it quite difficult to touch a live cap. Illustrated fitting instructions (e.g. Ikea) tend to be a bit vague but often seem to imply that live should be connected to the outer contact and neutral to the central pin. With this arrangement the live contact in an empty lampholder is less easy to touch with your fingers than the contacts of a BC lampholder. -- Mike Clarke |
#39
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
David Hansen wrote:
On Sun, 2 Nov 2008 15:22:26 -0000 someone who may be "gazz" wrote this:- i learnt not to put my fingers into a street lamp that had it's cover missing, wont be doing that again and it taught me to be a bit more respectfull of electricity.... My father learn't the same lesson when he put a metal knitting needle into a Shuko socket. I trust he was not demonstrating to a child the danger of sticking knitting needles into sockets |
#40
Posted to uk.d-i-y
|
|||
|
|||
put a euro socket in a uk house
In article ,
David Hansen writes: On Sun, 2 Nov 2008 14:00:18 -0000 someone who may be "gazz" wrote this:- I've never seen a non earthed shuko socket that could take an earthed plug. I have. There are parts of Europe where it's been standard; Holland IIRC, where protection against electric shock by non-conducting location means no earths are permitted on outlets in such areas. -- Andrew Gabriel [email address is not usable -- followup in the newsgroup] |