  #1   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 354
Default put a euro socket in a uk house

would there be any regulations i'd be breaking if i fitted a german shuko
style 2 pin with side earth strip socket in my house?

i have a german pinball machine which still has the molded on right angle
shuko plug on it's power lead, inside it also has a german shuko power point
for the engineers lamp to plug into (that one is bakalite and non earthed,
machine was made in 1976, so not that old), But i'd like to keep the
origional lead... just to emphasize more that it's a german machine if that
makes sense

Basicaly all i'd do is get a single outlet shuko socket, if possible a
switched one, and mount it next to the double 13 amp uk sockets,

i wouldent usually even give this kind of thing a second thought, i'd put
one in... better than using an adaptor or the easy solution which i know is
to change the power lead to a uk version.

but we are going to have one of those bods from warm front come round and
assess how much insulation we need to have added (stair celing area is
totaly open to the roof and has no insulation at all)
and i can just imagine him noticing the shuko socket and getting arsey about
it and putting on his report that i have illegal sockets in the house or
something like that.

  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 7,688
Default put a euro socket in a uk house


"gazz" wrote in message
...
would there be any regulations i'd be breaking if i fitted a german shuko
style 2 pin with side earth strip socket in my house?

i have a german pinball machine which still has the molded on right angle
shuko plug on it's power lead, inside it also has a german shuko power

point
for the engineers lamp to plug into (that one is bakalite and non earthed,
machine was made in 1976, so not that old), But i'd like to keep the
origional lead... just to emphasize more that it's a german machine if

that
makes sense

Basicaly all i'd do is get a single outlet shuko socket, if possible a
switched one, and mount it next to the double 13 amp uk sockets,

i wouldent usually even give this kind of thing a second thought, i'd put
one in... better than using an adaptor or the easy solution which i know

is
to change the power lead to a uk version.

but we are going to have one of those bods from warm front come round and
assess how much insulation we need to have added (stair celing area is
totaly open to the roof and has no insulation at all)
and i can just imagine him noticing the shuko socket and getting arsey

about
it and putting on his report that i have illegal sockets in the house or
something like that.


The Warm front "engineers" will not notice nor care about your electrical
installation in this case.

Adam


  #3   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 11,175
Default put a euro socket in a uk house

In article ,
"gazz" writes:
would there be any regulations i'd be breaking if i fitted a german shuko
style 2 pin with side earth strip socket in my house?


Yes - it's not shuttered.

i have a german pinball machine which still has the molded on right angle
shuko plug on it's power lead, inside it also has a german shuko power point
for the engineers lamp to plug into (that one is bakalite and non earthed,
machine was made in 1976, so not that old), But i'd like to keep the
origional lead... just to emphasize more that it's a german machine if that
makes sense

Basicaly all i'd do is get a single outlet shuko socket, if possible a
switched one, and mount it next to the double 13 amp uk sockets,


I haven't seen a switched one, and it would need fusing at
13A or a 16A MCB.

Just buy a travel adaptor.

i wouldent usually even give this kind of thing a second thought, i'd put
one in... better than using an adaptor or the easy solution which i know is
to change the power lead to a uk version.


The adaptor will have a fuse in it.

--
Andrew Gabriel
[email address is not usable -- followup in the newsgroup]
  #4   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 2
Default put a euro socket in a uk house


"gazz" wrote in message
...
would there be any regulations i'd be breaking if i fitted a german shuko
style 2 pin with side earth strip socket in my house?


Who would know or even care?

but we are going to have one of those bods from warm front come round and
assess how much insulation we need


Wht has that got to do with a socket?

and i can just imagine him noticing the shuko socket and getting arsey
about it and putting on his report that i have illegal sockets in the
house or something like that.


Are you genuinely thick? You certainly come across that way.
Why don't you hand yourself in at the nearest police station!


  #5   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 2,024
Default put a euro socket in a uk house

On Sat, 1 Nov 2008 20:12:16 -0000, "gazz" wrote:

i have a german pinball machine which still has the molded on right angle
shuko plug on it's power lead, inside it also has a german shuko power point
for the engineers lamp to plug into (that one is bakalite and non earthed,
machine was made in 1976, so not that old), But i'd like to keep the
origional lead... just to emphasize more that it's a german machine if that
makes sense


http://cpc.farnell.com/PL01350/elect...=pro-elec-9680




  #6   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,118
Default put a euro socket in a uk house

"gazz" wrote:

would there be any regulations i'd be breaking if i fitted a german shuko
style 2 pin with side earth strip socket in my house?

i have a german pinball machine which still has the molded on right angle
shuko plug on it's power lead, inside it also has a german shuko power point
for the engineers lamp to plug into (that one is bakalite and non earthed,
machine was made in 1976, so not that old), But i'd like to keep the
origional lead... just to emphasize more that it's a german machine if that
makes sense

Basicaly all i'd do is get a single outlet shuko socket, if possible a
switched one, and mount it next to the double 13 amp uk sockets,

i wouldent usually even give this kind of thing a second thought, i'd put
one in... better than using an adaptor or the easy solution which i know is
to change the power lead to a uk version.

but we are going to have one of those bods from warm front come round and
assess how much insulation we need to have added (stair celing area is
totaly open to the roof and has no insulation at all)
and i can just imagine him noticing the shuko socket and getting arsey about
it and putting on his report that i have illegal sockets in the house or
something like that.



I have a 3-way Euro extension lead that I bought in Spain. Obviously,
it came with a lead that had a Euro plug on it. All I did was cut off
the plug and replace it with a UK 13A plug. I can now plug in up to
three appliances with Euro plugs on them - I own several.

I feel sure that you could get these extension leads here in the UK.

  #7   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 354
Default put a euro socket in a uk house


"Tim" wrote in message
...

"gazz" wrote in message
...
would there be any regulations i'd be breaking if i fitted a german shuko
style 2 pin with side earth strip socket in my house?


Who would know or even care?


official people who like to **** stir,
come to do one job, nose around and report the things they find wrong whilst
in your house to the authorities?



but we are going to have one of those bods from warm front come round and
assess how much insulation we need


Wht has that got to do with a socket?


if it's not allowed to be used in england, then it's like having a gas
cooker connected with a length of rubber hose pushed onto a 1920's gas tap,


and i can just imagine him noticing the shuko socket and getting arsey
about it and putting on his report that i have illegal sockets in the
house or something like that.


Are you genuinely thick? You certainly come across that way.
Why don't you hand yourself in at the nearest police station!


course im thick, or i wouldent be asking questions here would i

we used to be allowed to do pretty much what we likes to our own houses at
one time, nowadays your not even allowed to put a patio down without asking
permision,

if we want to add a new ring main, we have to get it put in by a certified
bod with all the costs involved,

they wont empty your bin if you put the wrong items in it, fill it too full
or put it out before it's supposed to be put out,

i know if i added something to the gas supply that wasnt allowed, and it was
seen or reported to an official, they'd come round and cap the supply off,

i just wanted to check what the situation was with adding a german socket to
a uk house mains system,

easy enough to shutter the shuko socket if needed, a brat proof insert, you
have to twist the plug as you insert it to open the shutters,

  #8   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 3,356
Default put a euro socket in a uk house

On Sat, 1 Nov 2008 20:12:16 -0000 someone who may be "gazz"
wrote this:-

would there be any regulations i'd be breaking if i fitted a german shuko
style 2 pin with side earth strip socket in my house?


Yes. Such a socket does not maintain polarity, which means it falls
foul of the UK Wiring Regulations.

However, the Wiring Regulations do allow "non-standard"
equipment/installations on the say-so of a suitably qualified
electrical engineer, provided it provides an equivalent level of
safety. You would need to be prepared to argue this out in court
should something happen and you would be arguing this out with a
****** who knows bugger all about electrical systems, a lawyer.

Some may well think that you will also fall foul of some Mickey
Mouse UK laws, like "The Plugs and Sockets etc. (Safety) Regulations
1994". However you can argue, to the same ******, that this stuff
should never have been passed by the rogues' gallery at Westminster
as it is in conflict with the Single European Act of 1986 and
subsequent laws. I like the Single European Act as both the current
and previous Tory governments dare not speak against it, as it was
pushed through by the mad Woman of Finchley.

Your choice.

i have a german pinball machine which still has the molded on right angle
shuko plug on it's power lead, inside it also has a german shuko power point
for the engineers lamp to plug into (that one is bakalite and non earthed,
machine was made in 1976, so not that old), But i'd like to keep the
origional lead... just to emphasize more that it's a german machine if that
makes sense


Shuko sockets are **** poor compared to the BS 1363 design. However,
in this case I would consider it worth keeping the primitive plug as
an illustration of how poor other electrical wiring systems are. The
concept of RCDs for all socket outlets is ridiculous, but in the
case of a Shuko socket it is a good idea to fit one.

but we are going to have one of those bods from warm front come round and
assess how much insulation we need to have added (stair celing area is
totaly open to the roof and has no insulation at all)
and i can just imagine him noticing the shuko socket and getting arsey about
it and putting on his report that i have illegal sockets in the house or
something like that.


I doubt it. If you are worried then put the offensive socket a
little to the side of the BS 1363 sockets and disguise the Shuko
socket in some way for the visit. Use your initiative to work out
the disguise, don't expect to be spoon fed.



--
David Hansen, Edinburgh
I will *always* explain revoked encryption keys, unless RIP prevents me
http://www.opsi.gov.uk/acts/acts2000/00023--e.htm#54
  #9   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 666
Default put a euro socket in a uk house


"gazz" wrote in message
...
would there be any regulations i'd be breaking if i fitted a german shuko
style 2 pin with side earth strip socket in my house?

i have a german pinball machine which still has the molded on right angle
shuko plug on it's power lead, inside it also has a german shuko power

point
for the engineers lamp to plug into (that one is bakalite and non earthed,
machine was made in 1976, so not that old), But i'd like to keep the
origional lead... just to emphasize more that it's a german machine if

that
makes sense

Basicaly all i'd do is get a single outlet shuko socket, if possible a
switched one, and mount it next to the double 13 amp uk sockets,

i wouldent usually even give this kind of thing a second thought, i'd put
one in... better than using an adaptor or the easy solution which i know

is
to change the power lead to a uk version.

but we are going to have one of those bods from warm front come round and
assess how much insulation we need to have added (stair celing area is
totaly open to the roof and has no insulation at all)
and i can just imagine him noticing the shuko socket and getting arsey

about
it and putting on his report that i have illegal sockets in the house or
something like that.


ROFLMAO !!!!!!!!!!!!!!!!!!!!!!!!!!!

A Euro adapter costs about 3 quid at most. Why the hell would you want to
start messing about with the house wiring when the adapter is cheaper to buy
than the actual socket.

Remember this advice well. Put your brain into gear before picking up the
tools. An hour of useful thought is much better than an hour of useless
humiliation.

  #10   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 3,861
Default put a euro socket in a uk house

In message , BigWallop
writes

"gazz" wrote in message
...
would there be any regulations i'd be breaking if i fitted a german shuko
style 2 pin with side earth strip socket in my house?

.... ...
i wouldent usually even give this kind of thing a second thought, i'd put
one in... better than using an adaptor or the easy solution which i know

is
to change the power lead to a uk version.

but we are going to have one of those bods from warm front come round and
assess how much insulation we need to have added (stair celing area is
totaly open to the roof and has no insulation at all)
and i can just imagine him noticing the shuko socket and getting arsey

about
it and putting on his report that i have illegal sockets in the house or
something like that.


ROFLMAO !!!!!!!!!!!!!!!!!!!!!!!!!!!

A Euro adapter costs about 3 quid at most. Why the hell would you want to
start messing about with the house wiring when the adapter is cheaper to buy
than the actual socket.

Remember this advice well. Put your brain into gear before picking up the
tools. An hour of useful thought is much better than an hour of useless
humiliation.

Unfortunately, it's become common practice here of late

posting before thinking or asking the actual relevant authority has
become the norm

like the eejit who posted a while back asking how to remove a sticker
from his car rear window - much stupid discussion ensued, then he
actually tried removing it and it just peeled off

The ask first, think later culture is well and truly here

--
geoff


  #11   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 305
Default put a euro socket in a uk house

geoff wrote:
In message , BigWallop
writes

"gazz" wrote in message
...
would there be any regulations i'd be breaking if i fitted a german
shuko
style 2 pin with side earth strip socket in my house?

... ...
i wouldent usually even give this kind of thing a second thought, i'd
put
one in... better than using an adaptor or the easy solution which i know

is
to change the power lead to a uk version.

but we are going to have one of those bods from warm front come round
and
assess how much insulation we need to have added (stair celing area is
totaly open to the roof and has no insulation at all)
and i can just imagine him noticing the shuko socket and getting arsey

about
it and putting on his report that i have illegal sockets in the house or
something like that.


ROFLMAO !!!!!!!!!!!!!!!!!!!!!!!!!!!

A Euro adapter costs about 3 quid at most. Why the hell would you
want to
start messing about with the house wiring when the adapter is cheaper
to buy
than the actual socket.

Remember this advice well. Put your brain into gear before picking up
the
tools. An hour of useful thought is much better than an hour of useless
humiliation.

Unfortunately, it's become common practice here of late

posting before thinking or asking the actual relevant authority has
become the norm

like the eejit who posted a while back asking how to remove a sticker
from his car rear window - much stupid discussion ensued, then he
actually tried removing it and it just peeled off

The ask first, think later culture is well and truly here

but sometimes asking first is better than FUBAR then asking how to put
it back together

--
Kevin R
Reply address works
  #12   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 3,861
Default put a euro socket in a uk house

In message , Kevin
writes
geoff wrote:
In message ,
BigWallop writes

"gazz" wrote in message
...
would there be any regulations i'd be breaking if i fitted a german
shuko
style 2 pin with side earth strip socket in my house?

... ...
i wouldent usually even give this kind of thing a second thought,
i'd put
one in... better than using an adaptor or the easy solution which i know
is
to change the power lead to a uk version.

but we are going to have one of those bods from warm front come
round and
assess how much insulation we need to have added (stair celing area is
totaly open to the roof and has no insulation at all)
and i can just imagine him noticing the shuko socket and getting arsey
about
it and putting on his report that i have illegal sockets in the house or
something like that.


ROFLMAO !!!!!!!!!!!!!!!!!!!!!!!!!!!

A Euro adapter costs about 3 quid at most. Why the hell would you
want to
start messing about with the house wiring when the adapter is
cheaper to buy
than the actual socket.

Remember this advice well. Put your brain into gear before picking
up the
tools. An hour of useful thought is much better than an hour of useless
humiliation.

Unfortunately, it's become common practice here of late
posting before thinking or asking the actual relevant authority has
become the norm
like the eejit who posted a while back asking how to remove a
sticker from his car rear window - much stupid discussion ensued,
then he actually tried removing it and it just peeled off
The ask first, think later culture is well and truly here

but sometimes asking first is better than FUBAR then asking how to put
it back together

I'm not talking about that

I'm on about posting first, thinking later

--
geoff
  #13   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 43
Default put a euro socket in a uk house


"gazz" wrote in message
...
would there be any regulations i'd be breaking if i fitted a german shuko
style 2 pin with side earth strip socket in my house?


You may well be breaking some regulations depending on how you achieve it,
but in principle it is perfectly possible to fit Shuko sockets in UK. Some
hotels do. Have a look at the "Use of Guidance" section of the Approved
Document Part P of the Building Regs which says you can use:

..... an alternative national technical specification of any state which is a
contracting party to the European Economic Area which, in use, is
equivalent........

Convincing the Building Control Officer with your equivalent to the MWC in
German is another matter!

As others have said, there are simpler ways though.
BruceB


  #14   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 8,319
Default put a euro socket in a uk house

David Hansen wrote:


Shuko sockets are **** poor compared to the BS 1363 design. However,
in this case I would consider it worth keeping the primitive plug as
an illustration of how poor other electrical wiring systems are. The
concept of RCDs for all socket outlets is ridiculous, but in the
case of a Shuko socket it is a good idea to fit one.


Not wishing to start a fight here, but could someone elaborate on why the
Shuko socket/plug is **** poor compared to ours?

I've also heard it said that our overall domestic electrical system is far
better than the European system, which is why we haven't harmonised. Could
someone elaborate on that?


--
Dave - The Medway Handyman
www.medwayhandyman.co.uk


  #15   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 3,356
Default put a euro socket in a uk house

On Sun, 02 Nov 2008 09:46:19 GMT someone who may be "The Medway
Handyman" wrote this:-

Not wishing to start a fight here, but could someone elaborate on why the
Shuko socket/plug is **** poor compared to ours?


Does not maintain polarity. Unfused. Primitive earth connection.
Versions without an earth connection were (perhaps still are)
available, which leads to equipment needing to be earthed being
plugged into sockets without an earth connection. Shuttering not
standard.

That doesn't mean everyone dies in places with this sort of
equipment, but it is less safe than the UK designs.

I've also heard it said that our overall domestic electrical system is far
better than the European system, which is why we haven't harmonised. Could
someone elaborate on that?


Well the UK is in Europe (both Europe and the EU, which are two
separate things). There is also no one type of electrical socket and
wiring in the rest of Europe. However, two excellent features of the
UK approach are ring final circuits and BC lampholders. The former
allows anything portable to be plugged into any socket without much
concern. It is far more flexible and just works. The latter is
diminishing with new types of lamp and a desire amongst some
manufacturers to reduce their costs, but not the prices they charge,
by using ES lampholders. The main poor features of ES lampholders
are the way the lamp unscrews (due to heat) and the possibility of
wiring the live to the threaded bit (which is bound to happen in a
system with unpolarised plugs and sockets).


--
David Hansen, Edinburgh
I will *always* explain revoked encryption keys, unless RIP prevents me
http://www.opsi.gov.uk/acts/acts2000/00023--e.htm#54


  #16   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 43,017
Default put a euro socket in a uk house

In article ,
gazz wrote:
would there be any regulations i'd be breaking if i fitted a german
shuko style 2 pin with side earth strip socket in my house?


Almost certainly.

i have a german pinball machine which still has the molded on right
angle shuko plug on it's power lead, inside it also has a german shuko
power point for the engineers lamp to plug into (that one is bakalite
and non earthed, machine was made in 1976, so not that old), But i'd
like to keep the origional lead... just to emphasize more that it's a
german machine if that makes sense


Basicaly all i'd do is get a single outlet shuko socket, if possible a
switched one, and mount it next to the double 13 amp uk sockets,


i wouldent usually even give this kind of thing a second thought, i'd
put one in... better than using an adaptor or the easy solution which i
know is to change the power lead to a uk version.


Given the size of a pinball machine would an adaptor lead make that much
difference?

but we are going to have one of those bods from warm front come round
and assess how much insulation we need to have added (stair celing area
is totaly open to the roof and has no insulation at all) and i can just
imagine him noticing the shuko socket and getting arsey about it and
putting on his report that i have illegal sockets in the house or
something like that.


I doubt he'd be qualified in this sort of thing let alone interested.


If I were to do as you want I'd feed it via its own FCU/RCD unit. Like
this:-

http://www.tlc-direct.co.uk/Main_Ind...e_2/index.html

--
*If a pig loses its voice, is it disgruntled?

Dave Plowman London SW
To e-mail, change noise into sound.
  #17   Report Post  
Posted to uk.d-i-y
Rod Rod is offline
external usenet poster
 
Posts: 2,892
Default put a euro socket in a uk house

David Hansen wrote:
On Sun, 02 Nov 2008 09:46:19 GMT someone who may be "The Medway
Handyman" wrote this:-

Not wishing to start a fight here, but could someone elaborate on why the
Shuko socket/plug is **** poor compared to ours?


Does not maintain polarity. Unfused. Primitive earth connection.
Versions without an earth connection were (perhaps still are)
available, which leads to equipment needing to be earthed being
plugged into sockets without an earth connection. Shuttering not
standard.

That doesn't mean everyone dies in places with this sort of
equipment, but it is less safe than the UK designs.

I've also heard it said that our overall domestic electrical system is far
better than the European system, which is why we haven't harmonised. Could
someone elaborate on that?


Well the UK is in Europe (both Europe and the EU, which are two
separate things). There is also no one type of electrical socket and
wiring in the rest of Europe. However, two excellent features of the
UK approach are ring final circuits and BC lampholders. The former
allows anything portable to be plugged into any socket without much
concern. It is far more flexible and just works. The latter is
diminishing with new types of lamp and a desire amongst some
manufacturers to reduce their costs, but not the prices they charge,
by using ES lampholders. The main poor features of ES lampholders
are the way the lamp unscrews (due to heat) and the possibility of
wiring the live to the threaded bit (which is bound to happen in a
system with unpolarised plugs and sockets).


Sorry, is that the BC lampholder which allows two live connections to be
touched? (I accept that ES also suffers this possibility.)

I had been rather hoping that one positive aspect of CFLs (and other
efficient lamp technologies) might have been widespread use of, say, SES
which is much more difficult to stick my fingers into.

--
Rod

Hypothyroidism is a seriously debilitating condition with an insidious
onset.
Although common it frequently goes undiagnosed.
www.thyromind.info www.thyroiduk.org www.altsupportthyroid.org
  #18   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 532
Default put a euro socket in a uk house

BruceB wrote:
Have a look at the "Use of Guidance" section of the Approved
Document Part P of the Building Regs which says you can use:

..... an alternative national technical specification of any state which is a
contracting party to the European Economic Area which, in use, is
equivalent........

Convincing the Building Control Officer with your equivalent to the MWC in
German is another matter!


Who would counter with the observation that one can't pick-&-mix parts
of an electrical installation with others; you either use the German
standard in its entirety, or stick with the British one.

He may also proffer the opinion that the use of such wording is a
standard preamble to all the Approved Documents, and is merely a sop to
the courts to show that the guidance meets all the relevant
'single-market' regulations.

And then go tell you that the addition of a socket-outlet that is the
extension of an existing ring or radial circuit is not notifiable
(unless it is in a kitchen or special location).
--
Hugo Nebula
"If no-one on the internet wants a piece of this,
just how far from the pack have you strayed"?
  #19   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 305
Default put a euro socket in a uk house

geoff wrote:
In message , Kevin
writes
geoff wrote:
In message ,
BigWallop writes

"gazz" wrote in message
...
would there be any regulations i'd be breaking if i fitted a german
shuko
style 2 pin with side earth strip socket in my house?

... ...
i wouldent usually even give this kind of thing a second thought,
i'd put
one in... better than using an adaptor or the easy solution which i
know
is
to change the power lead to a uk version.

but we are going to have one of those bods from warm front come
round and
assess how much insulation we need to have added (stair celing area is
totaly open to the roof and has no insulation at all)
and i can just imagine him noticing the shuko socket and getting arsey
about
it and putting on his report that i have illegal sockets in the
house or
something like that.


ROFLMAO !!!!!!!!!!!!!!!!!!!!!!!!!!!

A Euro adapter costs about 3 quid at most. Why the hell would you
want to
start messing about with the house wiring when the adapter is
cheaper to buy
than the actual socket.

Remember this advice well. Put your brain into gear before picking
up the
tools. An hour of useful thought is much better than an hour of
useless
humiliation.

Unfortunately, it's become common practice here of late
posting before thinking or asking the actual relevant authority has
become the norm
like the eejit who posted a while back asking how to remove a
sticker from his car rear window - much stupid discussion ensued,
then he actually tried removing it and it just peeled off
The ask first, think later culture is well and truly here

but sometimes asking first is better than FUBAR then asking how to put
it back together

I'm not talking about that

I'm on about posting first, thinking later

that's exactly the same is it not????

--
Kevin R
Reply address works
  #20   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 14,085
Default put a euro socket in a uk house

On Sun, 02 Nov 2008 10:01:41 +0000, David Hansen wrote:

Does not maintain polarity.


Doesn't have to there is no such concept as "polarity" in the continental
wiring system. You have two wires with 230v (nominal) between them niether
is connected to earth.

Unfused. Primitive earth connection.
Versions without an earth connection were (perhaps still are)
available, which leads to equipment needing to be earthed being
plugged into sockets without an earth connection. Shuttering not
standard.

That doesn't mean everyone dies in places with this sort of
equipment, but it is less safe than the UK designs.

I've also heard it said that our overall domestic electrical system is

far
better than the European system, which is why we haven't harmonised.

Could
someone elaborate on that?


Well the UK is in Europe (both Europe and the EU, which are two
separate things). There is also no one type of electrical socket and
wiring in the rest of Europe. However, two excellent features of the
UK approach are ring final circuits and BC lampholders. The former
allows anything portable to be plugged into any socket without much
concern. It is far more flexible and just works. The latter is
diminishing with new types of lamp and a desire amongst some
manufacturers to reduce their costs, but not the prices they charge,
by using ES lampholders. The main poor features of ES lampholders
are the way the lamp unscrews (due to heat) and the possibility of
wiring the live to the threaded bit (which is bound to happen in a
system with unpolarised plugs and sockets).


--
David Hansen, Edinburgh
I will *always* explain revoked encryption keys, unless RIP prevents me
http://www.opsi.gov.uk/acts/acts2000/00023--e.htm#54


--
Cheers
Dave.





  #21   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 11,175
Default put a euro socket in a uk house

In article ,
Rod writes:
Sorry, is that the BC lampholder which allows two live connections to be
touched? (I accept that ES also suffers this possibility.)

I had been rather hoping that one positive aspect of CFLs (and other
efficient lamp technologies) might have been widespread use of, say, SES
which is much more difficult to stick my fingers into.


Whilst ES lampholders do seem to account for a number of
electrocutions, BC lampholders don't seem to have caused
a single one (in both cases, excluding faults).
In practice, I suspect its too difficult to get a good
enough connection between a finger and the pins, combined
with less opportunity to do so in normal use.
With ES lampholders, the main risk is gripping a bulb
to insert/remove it, and being electrocuted by exposed
metal of the lamp base. In most countries where it's
used, it's not possible to guarantee the live connection
is the tip, as live/neutral polarity isn't preserved into
appliances. (In the UK, it is required that the tip is
the live connection of an ES lampholder.)

--
Andrew Gabriel
[email address is not usable -- followup in the newsgroup]
  #22   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 11,175
Default put a euro socket in a uk house

In article et,
"Dave Liquorice" writes:
On Sun, 02 Nov 2008 10:01:41 +0000, David Hansen wrote:

Does not maintain polarity.


Doesn't have to there is no such concept as "polarity" in the continental
wiring system. You have two wires with 230v (nominal) between them niether
is connected to earth.


There are a few places like that (some Scandanavian countries derive
230V from 3-phase delta with one grounded leg, so 1 in 3 230V supplies
have no neutral, and some areas of France and probably elsewhere still
use IT earthing systems). However, the vast majority do have a grounded
neutral, and polarity is preserved as far as the back of the socket
outlet. With the socket outlets for the most part having no defined
polarity (French/Belgium) or being reversible (Schuko), that is where
it's lost. But given these sockets are used on supplies with no neutral
(however few), it must be assumed by all appliances that both sides are
phase connections.

--
Andrew Gabriel
[email address is not usable -- followup in the newsgroup]
  #23   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 3,356
Default put a euro socket in a uk house

On Sun, 02 Nov 2008 11:07:41 +0000 someone who may be Rod
wrote this:-

The main poor features of ES lampholders
are the way the lamp unscrews (due to heat) and the possibility of
wiring the live to the threaded bit (which is bound to happen in a
system with unpolarised plugs and sockets).


Sorry, is that the BC lampholder which allows two live connections to be
touched? (I accept that ES also suffers this possibility.)


The issue is when the lamps are in place. When the lamp is in place
in a BC lampholder it is not possible to touch any energised part.
However, when the lamp is in place in an ES lampholder it may be
possible to touch an energised part, particularly those with small
fingers, or push a metal item such as a knitting needle onto an
energised part.



--
David Hansen, Edinburgh
I will *always* explain revoked encryption keys, unless RIP prevents me
http://www.opsi.gov.uk/acts/acts2000/00023--e.htm#54
  #24   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 354
Default put a euro socket in a uk house


"The Medway Handyman" wrote in message
om...
David Hansen wrote:


Shuko sockets are **** poor compared to the BS 1363 design. However,
in this case I would consider it worth keeping the primitive plug as
an illustration of how poor other electrical wiring systems are. The
concept of RCDs for all socket outlets is ridiculous, but in the
case of a Shuko socket it is a good idea to fit one.


Not wishing to start a fight here, but could someone elaborate on why the
Shuko socket/plug is **** poor compared to ours?


i only lived in Germany when i was younger,

but from what i remember, the shuko socket has full length wiper style
contacts that give a much better connection to the plugs pins than the uk's
end contacts,

the shuko socket can do that as it doesn't need insulating strips like uk
ones do (with the exception of the 2 pin flat plugs on double insulated
appliances)
we need the insulation strips as out socket is a flat plate, the shuko one
is recessed, so it's impossible to tough the pins and you insert a shuko
socket like you can on a uk one.

the shuko socket and plugs are rated for 16 amps, uk 13 amps, to me that
says something about the design of the uk ones... i know why, it's those
little end contacts to stop electrocution if you insert an uninsulated pin
plug whilst touching the pins, don't make contact with the live bit till the
plug is practically all the way in.

i read so many stories of people buying things like welders from Germany,
they work fine over there on the 16 amp supply, but put a 13 amp plug on em
and they pop the fuse each time you strike an arc... meaning the expense of
installing a separate 16 amp supply and bulky blue socket just for the
welder.


yes you can plug the shuko plug in either way round, but in Europe the
appliances are double pole switched, i.e. switch live and neutral, not like
the uk with single pole switching,
there is supposed to be no polarity on AC supplies, so why the need to
insert the plug one way round only?

the earth strips on shuko sockets... whats wrong with them? there's 2 of
them to match the 2 earth strips on the plug, you get a good earth
connection which ever way you plug in.

I've never seen a non earthed shuko socket that could take an earthed plug.

they do have 2 types of plug in Germany, the round 2 pin with earth strip 16
amp plug for appliances needing earth and full power,

then you have the flat 2 pin plug (like a shaver plug) no earth on them as
they are only fitted to 2 core wire connected to double insulated
appliances... TV, videos' and the like.

you can plug one of them into an earthed shuko socket, but you cant plug an
earthed plug into a non earthed socket (only seen extension leads with the
flat non earthed sockets) all shuko sockets have a recess that matches the
plug's type, unlike a uk flat plate socket,

The thing i liked about German extension leads... you could buy some with
pin holes per socket, this is so you can plug in a single earthed plug, or 2
x flat non earthed plugs in a single socket, ideal for the hifi or
tv/video/dvd/sat box extension.

the flat non earthed plugs are for lower current appliances, 8 amps max i'd
guess, but could be lower,


afaik europe uses radial circuits, i certainly remember the breaker box in
our house in Germany being massive (1985 time), had a breaker for almost
every socket and light, tripping one would not plunge the whole house into
darkness or shut everything off like it does over here.
yes no fuses in the plugs, but hence the breakers for the sockets.

i also liked how if you reach the end of the cord.. say hoovering, and
tugged it a bit, you just pull the plug out the socket, over her you bend
the damn thing up a bit, straining the wire like hell,

I've also have a few times where I've gone to unplug a uk plug, and had the
top come away from a failed screw thread, leaving exposed terminals,
that's impossible to do with a shuko plug, the screw goes right through the
plug and is at 90 degrees to the way you pull it out the socket, so will
never come undone to expose live terminals whilst it is in the socket.

so it seems the only thing to complain about with the German system is the
lack of polarity, for which as mentioned the only thing that affects is a
table lamp, if you are stupid enough to unscrew the bulb while it's still
plugged in, whilst touching something earthed with one hand and reaching
right down and touching the screw thread of the bulb whilst unscrewing
it.... the rcd just trips when you do that anyway,

Give me the shuko plugs and sockets anyday,

  #25   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 2,538
Default put a euro socket in a uk house

gazz coughed up some electrons that declared:

would there be any regulations i'd be breaking if i fitted a german shuko
style 2 pin with side earth strip socket in my house?

i have a german pinball machine which still has the molded on right angle
shuko plug on it's power lead, inside it also has a german shuko power
point for the engineers lamp to plug into (that one is bakalite and non
earthed, machine was made in 1976, so not that old), But i'd like to keep
the origional lead... just to emphasize more that it's a german machine if
that makes sense

Basicaly all i'd do is get a single outlet shuko socket, if possible a
switched one, and mount it next to the double 13 amp uk sockets,

i wouldent usually even give this kind of thing a second thought, i'd put
one in... better than using an adaptor or the easy solution which i know
is to change the power lead to a uk version.

but we are going to have one of those bods from warm front come round and
assess how much insulation we need to have added (stair celing area is
totaly open to the roof and has no insulation at all)
and i can just imagine him noticing the shuko socket and getting arsey
about it and putting on his report that i have illegal sockets in the
house or something like that.


Personally, if you really want a fixed Shuko (as opposed to the very good
suggestions here of using a travel adaptor or shuko-strip) I would install
it off the end of a switched fused connection unit, fused correctly for the
application.

It'll be safe (as any shuko socket is), neat, switched and easy to
de-install (replace FCU with 13A socket).

Cheers

Tim




  #26   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 43
Default put a euro socket in a uk house


"Hugo Nebula" abuse@localhost wrote in message
...

Who would counter with the observation that one can't pick-&-mix parts of
an electrical installation with others; you either use the German standard
in its entirety, or stick with the British one.

He might counter with that but he would not be able to cite a regulation
that says so in those terms. There appear to be examples of mixed
installations in UK that have been accepted as discussed in this thread:
http://www.theiet.org/Forums/Forum/m...threadid=25916
Regards
BruceB


  #27   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 305
Default put a euro socket in a uk house

gazz wrote:

"The Medway Handyman" wrote in
message om...
David Hansen wrote:



yes you can plug the shuko plug in either way round, but in Europe the
appliances are double pole switched, i.e. switch live and neutral, not
like the uk with single pole switching,
there is supposed to be no polarity on AC supplies, so why the need to
insert the plug one way round only?


where did you get that idea from? AC has a Live cable which kills and a
neutral that does not, so yes it does mater which way round its plugged
in, usually over here only the live is fused so if you plug in a piece
of equipment the wrong way round yes it will work but under a fault
condition the fuse could blow on the neutral and the current still could
flow between Live and Earth
  #28   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 354
Default put a euro socket in a uk house


"Tim S" wrote in message
...

Personally, if you really want a fixed Shuko (as opposed to the very good
suggestions here of using a travel adaptor or shuko-strip) I would install
it off the end of a switched fused connection unit, fused correctly for
the
application.


that's what i'll do, have it on a travel adaptor at the moment, but dont
like it, sticks out a lot, looks ugly, and after a few days the 2 plugs seem
to be hanging from the sockets... prolly me catching the wire slightly.

the sockets in the games room are all at chest of shoulder height, so the
machines can be switched on and off easily and we dont leave one of them on
by mistake as would be the case if we had to crawl under the desks/machines
to get at a floor level socket (im prolly breaking regs having the 13 amp
sockets where i do anyway)

just it would look a hell of a lot neater to have a proper wall mounted
shuko socket or 2 next to the 13 amp sockets, as i plan to get another
pinball machine sometime, and the best ones come from germany,

also just noticed the travel adaptor i have in use dosent earth the shuko
socket, so i may as well have stuck a screwdriver in the earth hole of the
13 amp socket to open the shutters, and jammed the shuko's pins in the power
holes.

  #29   Report Post  
Posted to uk.d-i-y
Rod Rod is offline
external usenet poster
 
Posts: 2,892
Default put a euro socket in a uk house

Andrew Gabriel wrote:
In article ,
Rod writes:
Sorry, is that the BC lampholder which allows two live connections to be
touched? (I accept that ES also suffers this possibility.)

I had been rather hoping that one positive aspect of CFLs (and other
efficient lamp technologies) might have been widespread use of, say, SES
which is much more difficult to stick my fingers into.


Whilst ES lampholders do seem to account for a number of
electrocutions, BC lampholders don't seem to have caused
a single one (in both cases, excluding faults).
In practice, I suspect its too difficult to get a good
enough connection between a finger and the pins, combined
with less opportunity to do so in normal use.
With ES lampholders, the main risk is gripping a bulb
to insert/remove it, and being electrocuted by exposed
metal of the lamp base. In most countries where it's
used, it's not possible to guarantee the live connection
is the tip, as live/neutral polarity isn't preserved into
appliances. (In the UK, it is required that the tip is
the live connection of an ES lampholder.)


Thanks - I must admit surprise.

I think the nearest to bad outcomes I have had occurred when the glass
bulb separated from the metal base or when the bulb actually broke
leaving spikes of filament support. I doubt there is much difference
between ES and BC in this specific regard - though one may be more
likely than the other to separate like that.

In fact, thinking about it, the best improvement might be to ensure
double-pole switches are used. But I am probably missing something
important... (Yes - I know that would play havoc with multi-way
switching. :-) But would be feasible for table and standard lamps.)

--
Rod

Hypothyroidism is a seriously debilitating condition with an insidious
onset.
Although common it frequently goes undiagnosed.
www.thyromind.info www.thyroiduk.org www.altsupportthyroid.org
  #30   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 354
Default put a euro socket in a uk house


"David Hansen" wrote in message
...

The issue is when the lamps are in place. When the lamp is in place
in a BC lampholder it is not possible to touch any energised part.
However, when the lamp is in place in an ES lampholder it may be
possible to touch an energised part, particularly those with small
fingers, or push a metal item such as a knitting needle onto an
energised part.


we all gotta learn not to poke around in things we dont understand sometime
done we, it's all very well making things brat proof, but surely it's better
to teach the brats not to try inserting things into sockets/bulb holders,

i learnt not to put my fingers into a street lamp that had it's cover
missing, wont be doing that again and it taught me to be a bit more
respectfull of electricity....

think that's the word here, too many people fear electricity, give it a bit
of respect and you'll get on fine,



  #31   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 2,024
Default put a euro socket in a uk house

On Sun, 2 Nov 2008 14:00:18 -0000, "gazz" wrote:

"The Medway Handyman" wrote in message
. com...
David Hansen wrote:


Shuko sockets are **** poor compared to the BS 1363 design. However,
in this case I would consider it worth keeping the primitive plug as
an illustration of how poor other electrical wiring systems are. The
concept of RCDs for all socket outlets is ridiculous, but in the
case of a Shuko socket it is a good idea to fit one.


Not wishing to start a fight here, but could someone elaborate on why the
Shuko socket/plug is **** poor compared to ours?


i only lived in Germany when i was younger,

but from what i remember, the shuko socket has full length wiper style
contacts that give a much better connection to the plugs pins than the uk's
end contacts,


The "Schuko" comes in many forms both earthed and not earthed. In the
house we had in Germany it was wired with a mixture of both. The same
plug fitted both.

the shuko socket can do that as it doesn't need insulating strips like uk
ones do (with the exception of the 2 pin flat plugs on double insulated
appliances)
we need the insulation strips as out socket is a flat plate, the shuko one
is recessed, so it's impossible to tough the pins and you insert a shuko
socket like you can on a uk one.


Some are recessed but there are also flush mounting non-earthed
variants which allow you to touch both pins when inserting them.

the shuko socket and plugs are rated for 16 amps, uk 13 amps, to me that
says something about the design of the uk ones...


It says nothing other than you have forgotten the design voltage. Both
plugs are essentially similar in current handling capacity. The
Schuko is rated at 16A at 220V (3,520W) the BS1363 at 13A at 240V
(3,120W). If anything the 13A plug/socket is more reliable at high
currents. as the contact area is larger. The relatively high rating
of the Schuko means it has to be a tight fit in the socket which makes
it difficult for people with arthritic hands to plug them in properly
or remove them. It is common to find Schuko plugs very loose in the
sockets as they are not fully inserted.

i read so many stories


You shouldn't believe everything you read.

yes you can plug the shuko plug in either way round, but in Europe the
appliances are double pole switched, i.e. switch live and neutral, not like
the uk with single pole switching,


Appliances are switched identically in the UK and the rest of the EU.
I've never seen a non earthed shuko socket that could take an earthed plug.


They are very common.

afaik europe uses radial circuits, i certainly remember the breaker box in
our house in Germany being massive (1985 time), had a breaker for almost
every socket and light, tripping one would not plunge the whole house into
darkness or shut everything off like it does over here.


It usually does plunge everything into darkness as lighting circuits
are rarely wired one to each circuit breaker but as in the UK. Power
sockets are individually fused or done in groups.

i also liked how if you reach the end of the cord.. say hoovering, and
tugged it a bit, you just pull the plug out the socket, over her you bend
the damn thing up a bit, straining the wire like hell,


It also creates far more cases where plugs get broken or damaged by
furniture being pushed against them or people trip over the leads.

I've also have a few times where I've gone to unplug a uk plug, and had the
top come away from a failed screw thread, leaving exposed terminals,
that's impossible to do with a shuko plug,


But it's very easy to use the cable to pull it out (and often
necessary given the shape of some Schuko plugs) and pull one conductor
off in the process leaving you with an exposed live wire.
  #32   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 2,988
Default put a euro socket in a uk house

On Sun, 02 Nov 2008 11:07:41 +0000, Rod
wrote:


Sorry, is that the BC lampholder which allows two live connections to be
touched?


No - there's only one 'live' terminal.

--
Frank Erskine
  #33   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 2,538
Default put a euro socket in a uk house

gazz coughed up some electrons that declared:


"Tim S" wrote in message
...

Personally, if you really want a fixed Shuko (as opposed to the very good
suggestions here of using a travel adaptor or shuko-strip) I would
install it off the end of a switched fused connection unit, fused
correctly for the
application.


that's what i'll do, have it on a travel adaptor at the moment, but dont
like it, sticks out a lot, looks ugly, and after a few days the 2 plugs
seem to be hanging from the sockets... prolly me catching the wire
slightly.

the sockets in the games room are all at chest of shoulder height, so the
machines can be switched on and off easily and we dont leave one of them
on by mistake as would be the case if we had to crawl under the
desks/machines to get at a floor level socket (im prolly breaking regs
having the 13 amp sockets where i do anyway)

just it would look a hell of a lot neater to have a proper wall mounted
shuko socket or 2 next to the 13 amp sockets, as i plan to get another
pinball machine sometime, and the best ones come from germany,

also just noticed the travel adaptor i have in use dosent earth the shuko
socket, so i may as well have stuck a screwdriver in the earth hole of the
13 amp socket to open the shutters, and jammed the shuko's pins in the
power holes.


I'll just add to that, if using a switched fused unit, make sure that it's a
double pole switch, as the shuko is polarity-reversible (as pointed out by
everyone else). That will avoid an edge case of you thinking you've shut it
off, then fiddling inside your pinball machine and getting a nasty
surprise.

eg:

http://www.screwfix.com/prods/93481/...-13A-DP-Sw-FCU

You'd have unplugged the machine in this case, of course, but, well, you
know...

Cheers

Tim
  #34   Report Post  
Posted to uk.d-i-y
Rod Rod is offline
external usenet poster
 
Posts: 2,892
Default put a euro socket in a uk house

Frank Erskine wrote:
On Sun, 02 Nov 2008 11:07:41 +0000, Rod
wrote:


Sorry, is that the BC lampholder which allows two live connections to be
touched?


No - there's only one 'live' terminal.

Two potentially live connections...

--
Rod

Hypothyroidism is a seriously debilitating condition with an insidious
onset.
Although common it frequently goes undiagnosed.
www.thyromind.info www.thyroiduk.org www.altsupportthyroid.org
  #35   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 2,538
Default put a euro socket in a uk house

Tim S coughed up some electrons that declared:

I'll just add to that, if using a switched fused unit, make sure that it's
a double pole switch, as the shuko is polarity-reversible (as pointed out
by everyone else). That will avoid an edge case of you thinking you've
shut it off, then fiddling inside your pinball machine and getting a nasty
surprise.


Sorry. Brain spasm. I need to get some coffee.

The way I've written that is stupid. You are in control of the polarity up
until the shuko socket so you can never get an unswitched phase to the
machine even with a single pole switch.


Mind you, technically "neutral" is to be considered "live" (oridinary
people's "live" is actually called "phase" or "line"), and a DP switch will
offer protection against odd supply or wiring faults that involve the
neutral floating up to 240V above earth.

Still reasonable advice to use a DP switch (or none at all), but for
slightly different reasons to the way it appeared in the last post.

Cheers

Tim


  #36   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 3,356
Default put a euro socket in a uk house

On Sun, 2 Nov 2008 15:22:26 -0000 someone who may be "gazz"
wrote this:-

i learnt not to put my fingers into a street lamp that had it's cover
missing, wont be doing that again and it taught me to be a bit more
respectfull of electricity....


My father learn't the same lesson when he put a metal knitting
needle into a Shuko socket.



--
David Hansen, Edinburgh
I will *always* explain revoked encryption keys, unless RIP prevents me
http://www.opsi.gov.uk/acts/acts2000/00023--e.htm#54
  #37   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 3,356
Default put a euro socket in a uk house

On Sun, 2 Nov 2008 14:00:18 -0000 someone who may be "gazz"
wrote this:-

I've never seen a non earthed shuko socket that could take an earthed plug.


I have.


--
David Hansen, Edinburgh
I will *always* explain revoked encryption keys, unless RIP prevents me
http://www.opsi.gov.uk/acts/acts2000/00023--e.htm#54
  #38   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,031
Default put a euro socket in a uk house

Andrew Gabriel wrote:

With ES lampholders, the main risk is gripping a bulb
to insert/remove it, and being electrocuted by exposed
metal of the lamp base. In most countries where it's
used, it's not possible to guarantee the live connection
is the tip, as live/neutral polarity isn't preserved into
appliances. (In the UK, it is required that the tip is
the live connection of an ES lampholder.)


But all the recent ES lampholders I've seen are designed so that the
threaded part of the cap doesn't make contact until the lamp is screwed
almost fully home and the skirt extends just beyond the cap making it quite
difficult to touch a live cap. Illustrated fitting instructions (e.g. Ikea)
tend to be a bit vague but often seem to imply that live should be
connected to the outer contact and neutral to the central pin.

With this arrangement the live contact in an empty lampholder is less easy
to touch with your fingers than the contacts of a BC lampholder.

--
Mike Clarke
  #39   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 48
Default put a euro socket in a uk house

David Hansen wrote:
On Sun, 2 Nov 2008 15:22:26 -0000 someone who may be "gazz"
wrote this:-

i learnt not to put my fingers into a street lamp that had it's cover
missing, wont be doing that again and it taught me to be a bit more
respectfull of electricity....


My father learn't the same lesson when he put a metal knitting
needle into a Shuko socket.



I trust he was not demonstrating to a child the danger of sticking
knitting needles into sockets
  #40   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 11,175
Default put a euro socket in a uk house

In article ,
David Hansen writes:
On Sun, 2 Nov 2008 14:00:18 -0000 someone who may be "gazz"
wrote this:-

I've never seen a non earthed shuko socket that could take an earthed plug.


I have.


There are parts of Europe where it's been standard; Holland IIRC,
where protection against electric shock by non-conducting location
means no earths are permitted on outlets in such areas.

--
Andrew Gabriel
[email address is not usable -- followup in the newsgroup]
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Rojek Euro Saw. Pat Woodworking 0 September 4th 07 08:47 PM
euro convertor [email protected] UK diy 4 January 25th 07 08:08 PM
Euro Saws charlie b Woodworking 4 July 12th 05 12:03 AM
Euro Electrics John Rumm UK diy 415 June 12th 05 11:01 PM
EURO JIG charlie b Woodworking 0 December 15th 04 03:52 PM