Home Repair (alt.home.repair) For all homeowners and DIYers with many experienced tradesmen. Solve your toughest home fix-it problems.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,526
Default remove barbed fitting from irrigation tubing

I have a piece of 160 PSI irrigation tubing. OD a hair over an inch, ID just a bit over 3/4.

It broke at a connection. Well, the barbed connector fitting broke in half.

It would be easy to replace, except I can't get the old one out.

I don't want to shorten the tubing, as it's the right length now, or I would just cut each end and start over. I could do that and insert a piece, but I would have to buy a 100 foot roll.

Is there any good way to do this?
  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,636
Default remove barbed fitting from irrigation tubing

On 4/15/18 5:17 PM, TimR wrote:
I have a piece of 160 PSI irrigation tubing. OD a hair over an inch, ID just a bit over 3/4.

It broke at a connection. Well, the barbed connector fitting broke in half.

It would be easy to replace, except I can't get the old one out.

I don't want to shorten the tubing, as it's the right length now, or I would just cut each end and start over. I could do that and insert a piece, but I would have to buy a 100 foot roll.

Is there any good way to do this?

Does it have to be exactly the same tubing for some reason? If
not, go down to
your local farm supply store or Ace hardware. Buy a couple feet or so
of hose
and splice that in. A double hose barb and maybe some hose clamps
should get
you started. NAPA or another auto parts store might have something.
Could you
splice in a pvc hose nipple?
  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 15,279
Default remove barbed fitting from irrigation tubing

On Sunday, April 15, 2018 at 6:17:51 PM UTC-4, TimR wrote:
I have a piece of 160 PSI irrigation tubing. OD a hair over an inch, ID just a bit over 3/4.

It broke at a connection. Well, the barbed connector fitting broke in half.

It would be easy to replace, except I can't get the old one out.

I don't want to shorten the tubing, as it's the right length now, or I would just cut each end and start over. I could do that and insert a piece, but I would have to buy a 100 foot roll.

Is there any good way to do this?


Heat it very carefully with a propane torch or heat gun.
  #4   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 118
Default remove barbed fitting from irrigation tubing

On Sun, 15 Apr 2018 15:17:46 -0700 (PDT), TimR
wrote:

I don't want to shorten the tubing, as it's the right length now, or I would just cut each
end and start over. I could do that and insert a piece, but I would have to buy a 100 foot roll.


Go to a local plumber and ask to buy a few feet. Splice as needed.....

Or buy the 100ft roll and sell what is left on ebay or craigslist.

  #5   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 748
Default remove barbed fitting from irrigation tubing

On 4/15/2018 at 3:17:46 PM, TimR wrote:


I have a piece of 160 PSI irrigation tubing. OD a hair over an inch,
ID just a bit over 3/4.

It broke at a connection. Well, the barbed connector fitting broke
in half.

It would be easy to replace, except I can't get the old one out.

I don't want to shorten the tubing, as it's the right length now, or
I would just cut each end and start over. I could do that and insert
a piece, but I would have to buy a 100 foot roll.

Is there any good way to do this?


You didn't mention what kind of a fitting; tee, coupler, elbow etc. I
use a lot of this poly tubing on my properties. Instead of removing the
fitting from the tube, purchase the type of fitting that slips on over
the outside of the tubing. If you have a hard time wiggling it on with
the broken fitting in the tube, spray the tube with a little WD-40.

Other methods, boil a small pot of water, bring it outside, soak the
end of the tube with the broken fitting. The tube and the fitting have
a different thermal coefficient of expansion, the tubing will expand
more than the fitting and you should be able to pull it out.

OR

use a hack saw blade inside the fitting and carefully cut through the
fitting twice, 180 degrees apart, being careful to not damage the
tubing.

OR

Use a pair of pliers, wrap a rag around the tubing and try to crush the
broken fitting inside the tube, which will make it easier to remove.



--
"In matters of conscience, the law of the majority has no place."

"Truth Sounds Like Hate To Those Who Hate The Truth"


  #6   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 12
Default remove barbed fitting from irrigation tubing

All the fittings and tubing you ever wanted. Brass, stainless, etc.

https://www.mcmaster.com/#Standard-S...s-Steel-Tubing


"TimR" wrote in message ...
I have a piece of 160 PSI irrigation tubing. OD a hair over an inch, ID just a bit over 3/4.

It broke at a connection. Well, the barbed connector fitting broke in half.

It would be easy to replace, except I can't get the old one out.

I don't want to shorten the tubing, as it's the right length now, or I would just cut each end and start over. I could do that and insert a piece, but I would have to buy a 100 foot roll.

Is there any good way to do this?

  #7   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 9,074
Default remove barbed fitting from irrigation tubing

On 04/15/2018 04:17 PM, TimR wrote:
I have a piece of 160 PSI irrigation tubing. OD a hair over an inch, ID just a bit over 3/4.

It broke at a connection. Well, the barbed connector fitting broke in half.

It would be easy to replace, except I can't get the old one out.

I don't want to shorten the tubing, as it's the right length now, or I would just cut each end and start over. I could do that and insert a piece, but I would have to buy a 100 foot roll.

Is there any good way to do this?


Heat gun to soften it up?
  #8   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,526
Default remove barbed fitting from irrigation tubing

On Sunday, April 15, 2018 at 10:03:23 PM UTC-4, rbowman wrote:
Heat gun to soften it up?


That's my next plan.

I've also wondered if I could smash it with a big hammer and anvil and get the pieces out without too much damage to the pipe.

  #9   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,636
Default remove barbed fitting from irrigation tubing

On 4/16/18 6:00 AM, TimR wrote:
On Sunday, April 15, 2018 at 10:03:23 PM UTC-4, rbowman wrote:
Heat gun to soften it up?


That's my next plan.

I've also wondered if I could smash it with a big hammer and anvil and get the pieces out without too much damage to the pipe.

I might be more inclined to used vise grips or a C clamp for the
smashing idea.
You could see what's happening. Someone mentioned using a hacksaw to
cut the
fitting from the inside. Maybe cut the fitting a bit, then try
squeezing it.
  #10   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,526
Default remove barbed fitting from irrigation tubing

On Monday, April 16, 2018 at 7:09:05 AM UTC-4, Dean Hoffman wrote:
On 4/16/18 6:00 AM, TimR wrote:
On Sunday, April 15, 2018 at 10:03:23 PM UTC-4, rbowman wrote:
Heat gun to soften it up?


That's my next plan.

I've also wondered if I could smash it with a big hammer and anvil and get the pieces out without too much damage to the pipe.

I might be more inclined to used vise grips or a C clamp for the
smashing idea.


Ah, I like that. Seems worth a try.

I would have thought this to be a common problem, but I guess anyone using this stuff usually has plenty of extra around.


  #11   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 748
Default remove barbed fitting from irrigation tubing

On 4/16/2018 at 5:17:05 AM, TimR wrote:


On Monday, April 16, 2018 at 7:09:05 AM UTC-4, Dean Hoffman wrote:
On 4/16/18 6:00 AM, TimR wrote:
On Sunday, April 15, 2018 at 10:03:23 PM UTC-4, rbowman wrote:
Heat gun to soften it up?

That's my next plan.

I've also wondered if I could smash it with a big hammer and
anvil and get the pieces out without too much damage to the pipe.

I might be more inclined to used vise grips or a C clamp for
the smashing idea.


Ah, I like that. Seems worth a try.

I would have thought this to be a common problem, but I guess anyone
using this stuff usually has plenty of extra around.


Next time, install with plenty of slack to deal with these type of
situations. No matter how careful, you will always end up with broken
fittings or some kind of damage to the tubing.


--
"In matters of conscience, the law of the majority has no place."

"Truth Sounds Like Hate To Those Who Hate The Truth"
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Sell:Brass Male Adapter,Swivel Female Adapter,Flare Adapter,Tee,Connector,Barbed Tee,Elbow, valvetom Home Repair 0 November 27th 06 05:50 PM
Barbed Wire supplier ? Andrew Mawson UK diy 10 January 13th 06 12:21 PM
Stainless barbed insert adapter sizing?? Loren Amelang Metalworking 3 July 19th 05 09:51 PM
Any suggestions where to get brass barbed fittings? Sleeker GT Phwoar UK diy 3 May 19th 05 10:12 PM
Barbed/Slot Hinge Gotcha charlie b Woodworking 10 October 18th 04 09:07 AM


All times are GMT +1. The time now is 09:48 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"