Ice maker water line
I put a new water valve in the refrigerator,Now when i put back the copper
supply it has a small leak at the fitting. I cut the fitting off & installed a new compression ferrule & it still leaks no matter how tight i make it. Does it need teflon tape on the threads,it didn't have any before i changed the valve. How can i fix the leak ? -- Dell Inspiron Pentium dual-core 2.2 GHz 2 GB DDR2 SDRAM Windows Vista Home Premium SP1 --- news://freenews.netfront.net/ - complaints: --- |
#2
Posted to alt.home.repair
|
|||
|
|||
Ice maker water line
On Mar 30, 9:15*am, "desgnr" wrote:
I put a new water valve in the refrigerator,Now when i put back the copper supply it has a small leak at the fitting. I cut the fitting off & installed a new compression ferrule & it still leaks no matter how tight i make it. Does it need teflon tape on the threads,it didn't have any before i changed the valve. How can i fix the leak ? -- Dell Inspiron Pentium dual-core 2.2 GHz 2 GB DDR2 SDRAM Windows Vista Home Premium SP1 --- news://freenews.netfront.net/ - complaints: --- Nope, you don't use teflon tape on compression fittings. The threads are not sealing, the compression ring is. Teflon tape is only used on tapered pipe thread. Are you sure it is the compression fitting and not the nearby valve stem? I've seen a lot of these that leak at the valve stem after they have sat for years without being touched and then someone tunrs them off. Make sure the valve stem is all the way open and snug. If it is the compression fitting all I can suggest is trying again. Make sure everything is clean and the copper line is straight in the fitting and fully in as you tighten. |
#3
Posted to alt.home.repair
|
|||
|
|||
Ice maker water line
A couple things to try:
1) Spray the nut, ferrule, and end of the tube with oil before tightening. This allows the surfaces to slip instead of grab. 2) snug, not "as tight as you can get". The ferrules deform easily. I know of a plumber who uses Rectorseal #5 on compression fittings, but I've not had to do that. -- Christopher A. Young Learn more about Jesus www.lds.org .. "desgnr" wrote in message ... I put a new water valve in the refrigerator,Now when i put back the copper supply it has a small leak at the fitting. I cut the fitting off & installed a new compression ferrule & it still leaks no matter how tight i make it. Does it need teflon tape on the threads,it didn't have any before i changed the valve. How can i fix the leak ? -- Dell Inspiron Pentium dual-core 2.2 GHz 2 GB DDR2 SDRAM Windows Vista Home Premium SP1 --- news://freenews.netfront.net/ - complaints: --- |
#4
Posted to alt.home.repair
|
|||
|
|||
Ice maker water line
"desgnr" wrote in message ... I put a new water valve in the refrigerator,Now when i put back the copper supply it has a small leak at the fitting. I cut the fitting off & installed a new compression ferrule & it still leaks no matter how tight i make it. Does it need teflon tape on the threads,it didn't have any before i changed the valve. How can i fix the leak ? Try putting a liberal amount of pipe dope on\around the feral before tightening. |
#5
Posted to alt.home.repair
|
|||
|
|||
Ice maker water line
On Mar 30, 9:15*am, "desgnr" wrote:
I put a new water valve in the refrigerator,Now when i put back the copper supply it has a small leak at the fitting. I cut the fitting off & installed a new compression ferrule & it still leaks no matter how tight i make it. Does it need teflon tape on the threads,it didn't have any before i changed the valve. How can i fix the leak ? -- Dell Inspiron Pentium dual-core 2.2 GHz 2 GB DDR2 SDRAM Windows Vista Home Premium SP1 --- news://freenews.netfront.net/ - complaints: --- One of the most common mistakes with compression fittings is tightening them too tight. Sometimes if you have trouble with the brass ferrules you can try a plastic one. They seem to be a little more forgiving. Make sure the pipe is clean with no rough spots. Don't quite seat the pipe all the way against the stop. Google How to install a compression fitting" think there is a video with some good tips. Jimmie |
#6
Posted to alt.home.repair
|
|||
|
|||
Ice maker water line
On Mar 30, 12:05*pm, JIMMIE wrote:
On Mar 30, 9:15*am, "desgnr" wrote: I put a new water valve in the refrigerator,Now when i put back the copper supply it has a small leak at the fitting. I cut the fitting off & installed a new compression ferrule & it still leaks no matter how tight i make it. Does it need teflon tape on the threads,it didn't have any before i changed the valve. How can i fix the leak ? -- Dell Inspiron Pentium dual-core 2.2 GHz 2 GB DDR2 SDRAM Windows Vista Home Premium SP1 --- news://freenews.netfront.net/ - complaints: --- One of the most common mistakes with compression fittings is tightening them too tight. Sometimes if you have trouble with the brass ferrules you can try a plastic one. They seem to be a little more forgiving. Make sure the pipe is clean with no rough spots. Don't quite seat the pipe all the way against the stop. Google How to install a compression fitting" think there is a video with some good tips. Jimmie I cant always think of how to tell someone how to do something so I went to my book. To keep from over tightening it. hand tighten the nut and then tighten about 3/4 a turn with a wrench. Very important, use a second wrench to hold the body of the fitting. Cu and nylon ferrules work a little better than the brass ones because they are softer. Jimmie |
#7
Posted to alt.home.repair
|
|||
|
|||
Ice maker water line
"Doug Miller" wrote in message ... Try putting a liberal amount of pipe dope on\around the feral before tightening. To the OP: No, don't. You already got very good advice from "jamesgangnc". To tom: don't answer questions when you don't know what you're talking about. That solution has worked for me on more than one occasion. Doug......perhaps you shouldn't respond to issues you're ignorant about. |
#8
Posted to alt.home.repair
|
|||
|
|||
Ice maker water line
In article , "tom" wrote:
"desgnr" wrote in message ... I put a new water valve in the refrigerator,Now when i put back the copper supply it has a small leak at the fitting. I cut the fitting off & installed a new compression ferrule & it still leaks no matter how tight i make it. Does it need teflon tape on the threads,it didn't have any before i changed the valve. How can i fix the leak ? Try putting a liberal amount of pipe dope on\around the feral before tightening. To the OP: No, don't. You already got very good advice from "jamesgangnc". To tom: don't answer questions when you don't know what you're talking about. |
#9
Posted to alt.home.repair
|
|||
|
|||
Ice maker water line
desgnr wrote:
I put a new water valve in the refrigerator,Now when i put back the copper supply it has a small leak at the fitting. I cut the fitting off & installed a new compression ferrule & it still leaks no matter how tight i make it. Does it need teflon tape on the threads,it didn't have any before i changed the valve. How can i fix the leak ? On more than one occasion I've "saved" an dripping overtightened ferrule fitting by putting a couple of wraps of teflon tape around the ferrule lapping it onto the far end of the copper tubing by about 1/8". The teflon compresses to form a "gasket" which seals the leak. Scoff if you will, but I've always said that the essence of pragmatism can be stated as, "If it woiks, use it." G Jeff -- Jeffry Wisnia (W1BSV + Brass Rat '57 EE) The speed of light is 1.8*10e12 furlongs per fortnight. |
#10
Posted to alt.home.repair
|
|||
|
|||
Ice maker water line
I wonder if the OP used the same nut and fitting from the previous
installation, while just buying a new ferrule. If the old fitting had been tightened too much, there might have been damage or deformation of the nut or seat. -- Nonny Suppose you were an idiot. And suppose you were a member of Congress.... But then I repeat myself.' -Mark Twain .. |
#11
Posted to alt.home.repair
|
|||
|
|||
Ice maker water line
In article , "tom" wrote:
"Doug Miller" wrote in message ... Try putting a liberal amount of pipe dope on\around the feral before tightening. To the OP: No, don't. You already got very good advice from "jamesgangnc". To tom: don't answer questions when you don't know what you're talking about. That solution has worked for me on more than one occasion. No, it hasn't. Maybe it *appeared* to work, because there wasn't enough pressure behind the leak to push the water past a massive glob of pipe dope, but it's still not the right way to do it. Pipe dope is not a sealant, and has no place on a compression ferrule. If a compression fitting leaks, it's due to a poor fit. The proper solution is to fix the problem causing the poor fit, not to cover it up with a blob of pipe dope. Doug......perhaps you shouldn't respond to issues you're ignorant about. I didn't. |
#12
Posted to alt.home.repair
|
|||
|
|||
Ice maker water line
Thanks all:
I will by a new ferrule & nut. Jeff The Drunk wrote in message ... On Tue, 30 Mar 2010 13:06:13 -0400, Jeff Wisnia wrote: desgnr wrote: I put a new water valve in the refrigerator,Now when i put back the copper supply it has a small leak at the fitting. I cut the fitting off & installed a new compression ferrule & it still leaks no matter how tight i make it. Does it need teflon tape on the threads,it didn't have any before i changed the valve. How can i fix the leak ? On more than one occasion I've "saved" an dripping overtightened ferrule fitting by putting a couple of wraps of teflon tape around the ferrule lapping it onto the far end of the copper tubing by about 1/8". The teflon compresses to form a "gasket" which seals the leak. Scoff if you will, but I've always said that the essence of pragmatism can be stated as, "If it woiks, use it." G Jeff Well that makes a little more sense than pipe dope. --- news://freenews.netfront.net/ - complaints: --- |
#13
Posted to alt.home.repair
|
|||
|
|||
Ice maker water line
I know a plumber who uses Rectorseal on both the ferrule,
and the threads of the nut. Might work better. I havn't tried it. -- Christopher A. Young Learn more about Jesus www.lds.org .. "tom" wrote in message ... Try putting a liberal amount of pipe dope on\around the feral before tightening. |
#14
Posted to alt.home.repair
|
|||
|
|||
Ice maker water line
Jeff The Drunk wrote:
On Tue, 30 Mar 2010 11:25:09 -0500, "tom" wrote: "Doug Miller" wrote in message ... Try putting a liberal amount of pipe dope on\around the feral before tightening. To the OP: No, don't. You already got very good advice from "jamesgangnc". To tom: don't answer questions when you don't know what you're talking about. That solution has worked for me on more than one occasion. Doug......perhaps you shouldn't respond to issues you're ignorant about. Pipe dope is not a sealer it's a thread lube to allow steel/cast fittings to be tightened without thread bind. I've NEVER had problems with ferruled connections leaking when they were done carefully. Another poster going by Jimmie pretty much explained how to make successfully and lasting compression joints. Pipe dope is a sealer also. It's made for pipe threads, not compression fittings, but still it is a sealer. Note the product information "Lubricates and seals all threaded joints" http://www.hardwareandtools.com/Grea...y-6596688.html |
#15
Posted to alt.home.repair
|
|||
|
|||
Ice maker water line
Doug Miller wrote:
In article , "tom" wrote: "Doug Miller" wrote in message ... Try putting a liberal amount of pipe dope on\around the feral before tightening. To the OP: No, don't. You already got very good advice from "jamesgangnc". To tom: don't answer questions when you don't know what you're talking about. That solution has worked for me on more than one occasion. No, it hasn't. Maybe it *appeared* to work, because there wasn't enough pressure behind the leak to push the water past a massive glob of pipe dope, but it's still not the right way to do it. Pipe dope is not a sealant, and has no place on a compression ferrule. It is also a sealant, not for compression fittings, but still it is a sealant. "Lubricates and seals all threaded joints" http://www.hardwareandtools.com/Grea...y-6596688.html |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
ICE MAKER --- No Water - No Ice????? | Home Repair | |||
Run ice maker line in the cold air return in slab? | Home Repair | |||
Ice Maker/Water Line Installation | Home Repair | |||
GE Ice Maker -- Water Won't Stop | Home Ownership | |||
Ice Maker Line Question | Home Repair |