Default Ice Maker Line Question

Trying to replace icemaker line as the old copper one sprung a leak.
I bought the kit and you would think it wouldn't be much harder than
hooking up a hose to a faucet but of course I am running into trouble,
and I would like to blame it on the vague directions on the bag. I am
having a bitch of a time getting the compression screw onto the
nozzle. How far should the copper line go through the screw?

  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 5,823
Default Ice Maker Line Question


"Jeffy3" wrote in message
oups.com...
Trying to replace icemaker line as the old copper one sprung a leak.
I bought the kit and you would think it wouldn't be much harder than
hooking up a hose to a faucet but of course I am running into trouble,
and I would like to blame it on the vague directions on the bag. I am
having a bitch of a time getting the compression screw onto the
nozzle. How far should the copper line go through the screw?


There are no screws on a compression fitting. Do you mean the nut? if so,
put the nut over the tubing, slip the ferrule over the tubing and leave
about 1/4" showing. Slip that into the female end of the fitting and
tighten the nut.


  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 64
Default Ice Maker Line Question



On Jan 27, 2:18 pm, "Edwin Pawlowski" wrote:
ooglegroups.com...
?There are no screws on a compression fitting. Do you mean the nut?
if so,
put the nut over the tubing, slip the ferrule over the tubing and leave
about 1/4" showing. Slip that into the female end of the fitting and
tighten the nut.



Thanks. I meant a compression nut. The compression nuts which came
with the kit had the ferrule already inside the nut. Should the nut
be able to completely screw onto the female end of the T fitting? I
can't get it on more than halfway, and there's a slow drip coming out
of the other side of the nut (not the side closest to the T fitting).
What is normal cause of a drip? Not tight enough? Too tight?
Ferrule in wrong place?

  #4   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 4,500
Default Ice Maker Line Question



On Jan 28, 1:27 pm, "Jeffy3" wrote:
On Jan 27, 2:18 pm, "Edwin Pawlowski" wrote:
ooglegroups.com...
?There are no screws on a compression fitting. Do you mean the nut?
if so,

put the nut over the tubing, slip the ferrule over the tubing and leave
about 1/4" showing. Slip that into the female end of the fitting and
tighten the nut.Thanks. I meant a compression nut. The compression nuts which came

with the kit had the ferrule already inside the nut. Should the nut
be able to completely screw onto the female end of the T fitting? I
can't get it on more than halfway, and there's a slow drip coming out
of the other side of the nut (not the side closest to the T fitting).
What is normal cause of a drip? Not tight enough? Too tight?
Ferrule in wrong place?


The nut should go on most, or all of the way. The ferrule should be
seperate from the nut. As Edwin stated, the nut goes on the tubing,
then the ferrule, and then you insert the tubing as far as it will go
into the fitting. While keeping some pressure on it to make sure it
stays all the way in, tighten down the nut, which compresses the
ferrule against the tubing. If you botched it, easiest thing is to
cut of the end of the tubing, get a new ferrule and redo.

  #5   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 64
Default Ice Maker Line Question



On Jan 28, 1:47 pm, wrote:
On Jan 28, 1:27 pm, "Jeffy3" wrote:

On Jan 27, 2:18 pm, "Edwin Pawlowski" wrote:
ooglegroups.com...
?There are no screws on a compression fitting. Do you mean the nut?
if so,


put the nut over the tubing, slip the ferrule over the tubing and leave
about 1/4" showing. Slip that into the female end of the fitting and
tighten the nut.Thanks. I meant a compression nut. The compression nuts which came

with the kit had the ferrule already inside the nut. Should the nut
be able to completely screw onto the female end of the T fitting? I
can't get it on more than halfway, and there's a slow drip coming out
of the other side of the nut (not the side closest to the T fitting).
What is normal cause of a drip? Not tight enough? Too tight?
Ferrule in wrong place?The nut should go on most, or all of the way. The ferrule should be

seperate from the nut. As Edwin stated, the nut goes on the tubing,
then the ferrule, and then you insert the tubing as far as it will go
into the fitting. While keeping some pressure on it to make sure it
stays all the way in, tighten down the nut, which compresses the
ferrule against the tubing. If you botched it, easiest thing is to
cut of the end of the tubing, get a new ferrule and redo.



Are there alternate names for these ferrules? I don't recall seeing
anything by that name in the hardware store where the compression nuts
were.



  #6   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 4,500
Default Ice Maker Line Question



On Jan 29, 8:53 am, "Jeffy3" wrote:
On Jan 28, 1:47 pm, wrote:





On Jan 28, 1:27 pm, "Jeffy3" wrote:


On Jan 27, 2:18 pm, "Edwin Pawlowski" wrote:
ooglegroups.com...
?There are no screws on a compression fitting. Do you mean the nut?
if so,


put the nut over the tubing, slip the ferrule over the tubing and leave
about 1/4" showing. Slip that into the female end of the fitting and
tighten the nut.Thanks. I meant a compression nut. The compression nuts which came
with the kit had the ferrule already inside the nut. Should the nut
be able to completely screw onto the female end of the T fitting? I
can't get it on more than halfway, and there's a slow drip coming out
of the other side of the nut (not the side closest to the T fitting).
What is normal cause of a drip? Not tight enough? Too tight?
Ferrule in wrong place?The nut should go on most, or all of the way. The ferrule should be

seperate from the nut. As Edwin stated, the nut goes on the tubing,
then the ferrule, and then you insert the tubing as far as it will go
into the fitting. While keeping some pressure on it to make sure it
stays all the way in, tighten down the nut, which compresses the
ferrule against the tubing. If you botched it, easiest thing is to
cut of the end of the tubing, get a new ferrule and redo.Are there alternate names for these ferrules? I don't recall seeing

anything by that name in the hardware store where the compression nuts
were.- Hide quoted text -- Show quoted text -




They may call them compression sleeves. Regardless of what they call
them, they should be located with the compression fittings and very
obvious. You get several of them in a small bag.

  #7   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 64
Default Ice Maker Line Question



On Jan 29, 9:10 am, wrote:
On Jan 29, 8:53 am, "Jeffy3" wrote:





On Jan 28, 1:47 pm, wrote:


On Jan 28, 1:27 pm, "Jeffy3" wrote:


On Jan 27, 2:18 pm, "Edwin Pawlowski" wrote:
ooglegroups.com...
?There are no screws on a compression fitting. Do you mean the nut?
if so,


put the nut over the tubing, slip the ferrule over the tubing and leave
about 1/4" showing. Slip that into the female end of the fitting and
tighten the nut.Thanks. I meant a compression nut. The compression nuts which came
with the kit had the ferrule already inside the nut. Should the nut
be able to completely screw onto the female end of the T fitting? I
can't get it on more than halfway, and there's a slow drip coming out
of the other side of the nut (not the side closest to the T fitting).
What is normal cause of a drip? Not tight enough? Too tight?
Ferrule in wrong place?The nut should go on most, or all of the way. The ferrule should be
seperate from the nut. As Edwin stated, the nut goes on the tubing,
then the ferrule, and then you insert the tubing as far as it will go
into the fitting. While keeping some pressure on it to make sure it
stays all the way in, tighten down the nut, which compresses the
ferrule against the tubing. If you botched it, easiest thing is to
cut of the end of the tubing, get a new ferrule and redo.Are there alternate names for these ferrules? I don't recall seeing

anything by that name in the hardware store where the compression nuts
were.- Hide quoted text -- Show quoted text -They may call them compression sleeves. Regardless of what they call

them, they should be located with the compression fittings and very
obvious. You get several of them in a small bag.- Hide quoted text -- Show quoted text -




Thanks. I believe they did have "sleeves"

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Dumb Ice Maker Question? SMcK Home Repair 37 January 8th 07 04:02 PM
Ice Maker Question [email protected] Home Repair 1 July 1st 06 05:10 PM
kenmore ice maker stopped making ice ESM Home Repair 3 September 7th 05 03:21 AM
Ice Maker Question Mr Mow Town Home Repair 9 September 5th 05 08:37 PM
Automatic ice maker question Scall5 Home Repair 7 November 8th 04 02:39 AM


All times are GMT +1. The time now is 06:23 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"