Woodworking (rec.woodworking) Discussion forum covering all aspects of working with wood. All levels of expertise are encouraged to particiapte.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 2,223
Default just got very lucky

Last day of work today.
left early , went down to the shop, fired up the compressor and it
didn't shut at the right pressure. Switch is still giving me a problem.
So I shut it, and go to check it.

I hear leaking in 2 spots..
My Home Depot (HUSKY) 3/8 to 1/4 adapter has blown... it just came
slightly apart. I don't even bother with the other leak... I notice that
it's wobbling... Thought the air filter was the culprit, thought it lost
the threads, being an HF unit. Not the case.
I throw the lever valves open and discharge it.

Boy I did not know how lucky I was until it was empty.

See the pics in alt binaries... had that blown with 100psi I am sure it
would have done some damage to the stuff across from it, paint cans and
wood storage.
--
Jeff
  #2   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 3,350
Default just got very lucky


"woodchucker" wrote:

Last day of work today.
left early , went down to the shop, fired up the compressor and it
didn't shut at the right pressure. Switch is still giving me a
problem.
So I shut it, and go to check it.

I hear leaking in 2 spots..
My Home Depot (HUSKY) 3/8 to 1/4 adapter has blown... it just came
slightly apart. I don't even bother with the other leak... I notice
that it's wobbling... Thought the air filter was the culprit,
thought it lost the threads, being an HF unit. Not the case.
I throw the lever valves open and discharge it.

Boy I did not know how lucky I was until it was empty.

See the pics in alt binaries... had that blown with 100psi I am sure
it would have done some damage to the stuff across from it, paint
cans and wood storage.


-----------------------------------------------------
Time to redo your plumbing.

You had an accident waiting to happen and it did.

You had placed an excessive bending load on a brass fitting and it
failed.

Don't feel like the Lone Ranger, it's a more common error than you
might
think.

Lew



  #3   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 2,223
Default just got very lucky

On 12/31/2013 2:23 PM, Lew Hodgett wrote:
"woodchucker" wrote:

Last day of work today.
left early , went down to the shop, fired up the compressor and it
didn't shut at the right pressure. Switch is still giving me a
problem.
So I shut it, and go to check it.

I hear leaking in 2 spots..
My Home Depot (HUSKY) 3/8 to 1/4 adapter has blown... it just came
slightly apart. I don't even bother with the other leak... I notice
that it's wobbling... Thought the air filter was the culprit,
thought it lost the threads, being an HF unit. Not the case.
I throw the lever valves open and discharge it.

Boy I did not know how lucky I was until it was empty.

See the pics in alt binaries... had that blown with 100psi I am sure
it would have done some damage to the stuff across from it, paint
cans and wood storage.


-----------------------------------------------------
Time to redo your plumbing.

You had an accident waiting to happen and it did.

You had placed an excessive bending load on a brass fitting and it
failed.

Don't feel like the Lone Ranger, it's a more common error than you
might
think.

Lew



You might be right about that Lew, was not thinking that way.
Might be time to move the filter and manifold to the wall and run flex
line to it.

--
Jeff
  #4   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 3,350
Default just got very lucky

Time to redo your plumbing.

You had an accident waiting to happen and it did.

You had placed an excessive bending load on a brass fitting and it
failed.

Don't feel like the Lone Ranger, it's a more common error than you
might
think.

Lew

-----------------------------------------------------
"woodchucker" wrote:
You might be right about that Lew, was not thinking that way.
Might be time to move the filter and manifold to the wall and run
flex line to it.

-----------------------------------------------------
For a few $ worth of pipe fittings, you can create a well engineered
manifold.

Get some 3/4 pipe nipples, 6''-8" long.

Assemble a manifold using these nipples and some 3/4" x 3/4" x 1/2"
(side)
pipe tees.

At each tee, assemble a pair if 1/2" street ells in a 180 degree turn
around.

The idea is to get the air to reverse direction so any water vapor
drops out.

You now have a 1/2" female pipe fitting facing down that you can equip
with a hose coupling so that a hose will hang down when coupled
together.

Cap one end with a 3/4" cap and the other with a petcock to drain any
water
in the pipe manifold and a 3/4 x 3/4 x 3/4 tee on the entry end for
the 3/4
hose from the regulator.

Incline the 3/4" pipe about 1'4"/ft and you are good to go.

Install regulator at tank and connect regulator to manifold with a
3/4" hose
and you are good to go.

The manifold can be expanded at any time with more pipe fittings.

Have fun.

Lew


  #5   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 583
Default just got very lucky



"Lew Hodgett" wrote

The idea is to get the air to reverse direction so any water vapor drops
out.


I use a piece of 1 1/2" steel pipe in a vertical position, and put the air
into a t at the bottom of the pipe. Petcock to drain water. At the top of
said 5 foot pip, the air comes out, cool and de-moistened.

My idea is to get the air to move slowly, and plenty-O-surface area to cool.
Slow means water will not get pushed upwards with the air flow. Cool means
water does not condense in the lines as the air does not cool later
downstream. I have a couple manifolds with disconnects in differing numbers
so I can use them anywhere in the shop as needs arise.

Jim in NC


---
This email is free from viruses and malware because avast! Antivirus protection is active.
http://www.avast.com



  #6   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 2,223
Default just got very lucky

On 1/2/2014 11:50 PM, Morgans wrote:


"Lew Hodgett" wrote

The idea is to get the air to reverse direction so any water vapor
drops out.


I use a piece of 1 1/2" steel pipe in a vertical position, and put the
air into a t at the bottom of the pipe. Petcock to drain water. At the
top of said 5 foot pip, the air comes out, cool and de-moistened.

My idea is to get the air to move slowly, and plenty-O-surface area to
cool. Slow means water will not get pushed upwards with the air flow.
Cool means water does not condense in the lines as the air does not cool
later downstream. I have a couple manifolds with disconnects in
differing numbers so I can use them anywhere in the shop as needs arise.

Jim in NC

---
This email is free from viruses and malware because avast! Antivirus
protection is active.
http://www.avast.com


Yea, that's not a bad idea. I have similar in each of the drops, the t's
allow air to t off, but the moisture drops to the bottom of the pipe
where a ball valve allows me to relieve the line of moisture.

But starting out that way seems like a good idea too, as all the
moisture is there to begin with.

--
Jeff
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
OT; Lucky? The Medway Handyman UK diy 30 October 19th 13 02:37 PM
Almost got lucky with the VFD... Bob La Londe Metalworking 6 January 2nd 11 02:04 AM
Sometimes you just get lucky Brian Henderson Woodworking 15 October 26th 07 04:48 PM
Are you lucky ? [email protected] Home Repair 2 February 8th 07 10:35 PM
How lucky we are [email protected] UK diy 0 September 23rd 06 09:45 PM


All times are GMT +1. The time now is 05:13 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"