Wiring mains smoke alarms
Please help me to channel into the walls just once... :-)
I want to install two or three mains smoke alarms, and interlink them (so when one goes off, they all go off). What type of smoke alarm is recommended for a hall way near a kitchen, a den, and an upstairs landing? As I'll probably put the wiring into the walls before buying the smoke alarms, what cable should I lay to power and interlink all three devices? Cheers, David. |
#2
|
|||
|
|||
Wiring mains smoke alarms
These are fairly easy to source and install, I fitted four interlinked
about 3 years ago, I think they were about £20 to £23 each. Use a heat dectecting one in the kitchen so it;s not affected by smoke and ordinary smoke dectectors elsewhere.Use three core (red,blue,yellow) plus earth to interconnect them, red/blue for mains supply and yellow to interconnect them, dont be tempted to use ordinary twin & earth using earth to interconnect - not allowed. Pick up mains supply from lighting circuit at fuse board, not protected by RCD as you want lights and alarms to work in event of emergency. Mark Atherton On 8 Dec 2003 04:04:51 -0800, (David Robinson) wrote: Please help me to channel into the walls just once... :-) I want to install two or three mains smoke alarms, and interlink them (so when one goes off, they all go off). What type of smoke alarm is recommended for a hall way near a kitchen, a den, and an upstairs landing? As I'll probably put the wiring into the walls before buying the smoke alarms, what cable should I lay to power and interlink all three devices? Cheers, David. |
#3
|
|||
|
|||
Wiring mains smoke alarms
lighting circuit at fuse board, not protected by RCD as you want
lights and alarms to work in event of emergency. Yes... that reminds me. I was wondering the other day why manufacturers don't combine burglar alarms with smoke alarms. Certainly would cut down on the wiring(?) Colin |
#4
|
|||
|
|||
Wiring mains smoke alarms
In article ,
"Colin" writes: lighting circuit at fuse board, not protected by RCD as you want lights and alarms to work in event of emergency. Yes... that reminds me. I was wondering the other day why manufacturers don't combine burglar alarms with smoke alarms. Certainly would cut down on the wiring(?) Many burglar alarms support smoke alarms. I've got 3 on mine. -- Andrew Gabriel |
#5
|
|||
|
|||
Wiring mains smoke alarms
I bought 12v linked detectors and wired them into our house alarm on the
24hr loop. -- Pete Cross "Colin" wrote in message ... lighting circuit at fuse board, not protected by RCD as you want lights and alarms to work in event of emergency. Yes... that reminds me. I was wondering the other day why manufacturers don't combine burglar alarms with smoke alarms. Certainly would cut down on the wiring(?) Colin |
#6
|
|||
|
|||
Wiring mains smoke alarms
"Colin" wrote in message ... lighting circuit at fuse board, not protected by RCD as you want lights and alarms to work in event of emergency. Yes... that reminds me. I was wondering the other day why manufacturers don't combine burglar alarms with smoke alarms. Certainly would cut down on the wiring(?) Colin An alarm panel with Personal Attack zone can also be used for smoke detection devices. The PA zone is a constant circuit, so a smoke detector with a normally closed switch (there are many on the market) can be placed on this loop. There are also alarm panels with a zone or two, which can be programmed as fire detection circuits, so you're not stuck if you wish to place fire and intruder all in one panel. --- http://www.basecuritysystems.no-ip.com Outgoing mail is certified Virus Free. Checked by AVG anti-virus system (http://www.grisoft.com). Version: 6.0.545 / Virus Database: 339 - Release Date: 27/11/03 |
#7
|
|||
|
|||
Wiring mains smoke alarms
"Pete Cross" 1@2 wrote in message ... I bought 12v linked detectors and wired them into our house alarm on the 24hr loop. Interesting idea. I was actually thinking of the actual sensor housing having a PIR as well as a smoke detector. Also using the same wires. Wouldn't you want a different siren for smoke? With a burglar alarm you run into the house and lock the doors... and the other, you run out... Colin |
#8
|
|||
|
|||
Wiring mains smoke alarms
On Mon, 8 Dec 2003 16:16:53 -0000, "Colin"
wrote: "Pete Cross" 1@2 wrote in message ... I bought 12v linked detectors and wired them into our house alarm on the 24hr loop. Interesting idea. I was actually thinking of the actual sensor housing having a PIR as well as a smoke detector. Also using the same wires. Wouldn't you want a different siren for smoke? With a burglar alarm you run into the house and lock the doors... and the other, you run out... The alarm panel I installed in my last house in the mid 90s supported a separate fire circuit, and the PIRs had smoke detectors in 'em. There was a separate bell box connection for the fire circuit too, so I wired it up to an old firebell I had lying around I think it was an Omnicron but I wouldn't swear to it.....the name MST3000 springs to mind too. It's time to source a similar panel for this house too I think. After fitting mains powered detectors in other houses I want them here as well, as well as an extra couple of zones. -- cheers, witchy/binarydinosaurs |
#9
|
|||
|
|||
Wiring mains smoke alarms
And be sure they also carry the battery back-up system.
|
#10
|
|||
|
|||
Wiring mains smoke alarms
"Colin" wrote in message ... "Pete Cross" 1@2 wrote in message ... I bought 12v linked detectors and wired them into our house alarm on the 24hr loop. Interesting idea. I was actually thinking of the actual sensor housing having a PIR as well as a smoke detector. There might then be a problem with the positioning of such a combined device. Smoke detectors need to be away from the corners of walls and ceilings to aid a fast detection of smoke and PIRs are usually placed in such places. -- Adam |
#11
|
|||
|
|||
Wiring mains smoke alarms
In article ,
"Colin" writes: "Pete Cross" 1@2 wrote in message ... I bought 12v linked detectors and wired them into our house alarm on the 24hr loop. Interesting idea. I was actually thinking of the actual sensor housing having a PIR as well as a smoke detector. Also using the same wires. Generally, PIRs tend to be put in positions where a smoke alarm doesn't work properly, in corners between ceiling and wall, or worse, ceiling and two walls. Wouldn't you want a different siren for smoke? With a burglar alarm you run into the house and lock the doors... and the other, you run out... If the alarm has fire detection zones or can program zones for this purpose, then yes. In my case, the siren for fire is three blasts and then a silence where the fourth would be, repeated. That's in addition to the smoke detector's built-in siren. -- Andrew Gabriel |
#12
|
|||
|
|||
Wiring mains smoke alarms
For siting recommendations & ability to d/load
wiring instructions see www.smoke-alarms.co.uk [Wiring is shown in Installer manuals/see tab for this page] (David Robinson) wrote in message . com... Please help me to channel into the walls just once... :-) I want to install two or three mains smoke alarms, and interlink them (so when one goes off, they all go off). What type of smoke alarm is recommended for a hall way near a kitchen, a den, and an upstairs landing? As I'll probably put the wiring into the walls before buying the smoke alarms, what cable should I lay to power and interlink all three devices? Cheers, David. |
#14
|
|||
|
|||
Wiring mains smoke alarms
see www.smoke-alarms.co.uk
Suggest D/load installer manuals [pdf] on Manuals page. (Andrew Gabriel) wrote in message ... In article , "Colin" writes: lighting circuit at fuse board, not protected by RCD as you want lights and alarms to work in event of emergency. Yes... that reminds me. I was wondering the other day why manufacturers don't combine burglar alarms with smoke alarms. Certainly would cut down on the wiring(?) Many burglar alarms support smoke alarms. I've got 3 on mine. |
#15
|
|||
|
|||
Wiring mains smoke alarms
"David Robinson" wrote in message om... Please help me to channel into the walls just once... :-) I want to install two or three mains smoke alarms, and interlink them (so when one goes off, they all go off). What type of smoke alarm is recommended for a hall way near a kitchen, a den, and an upstairs landing? As I'll probably put the wiring into the walls before buying the smoke alarms, what cable should I lay to power and interlink all three devices? I wrote a sect for the UK Selfbuild FAQ on this .... you can get the FAQ on www.borpin.co.uk/sbfaq or original doc on SelfBuild site in files area: http://uk.groups.yahoo.com/group/UK_Selfbuild/ Rick |
#16
|
|||
|
|||
Wiring mains smoke alarms
Colin wrote:
lighting circuit at fuse board, not protected by RCD as you want lights and alarms to work in event of emergency. Yes... that reminds me. I was wondering the other day why manufacturers don't combine burglar alarms with smoke alarms. Certainly would cut down on the wiring(?) Essentially because the placement requirements for the two things are different. Colin |
#17
|
|||
|
|||
Wiring mains smoke alarms
Thank you all for your help, and for the excellent links.
Cheers, David. |
#18
|
|||
|
|||
Wiring mains smoke alarms
Wouldn't you want a different siren for smoke? With a burglar alarm
you run into the house and lock the doors... and the other, you run out... My alarm gives a separate ring tone if the zone is set to be a fire zone. If you set it to be a 24h fire zone, you don't need to set the alarm for protection, either. I've wired my intruder alarm up to my mains smoke detectors via an optional relay control output. You get the detector alarms plus the alarm buzzer. You'll even get the outside bell box going, when I can be bothered to fit it. Christian. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Mains/Battery smoke alarms | UK diy | |||
Cheap battery operated smoke alarms... grrrr.... | UK diy | |||
wiring for mains halogen lighting | UK diy | |||
Smoke Alarms in domestic/holiday homes - new build, bank holiday wiring | UK diy | |||
Linked Mains Smoke Detectors | UK diy |