UK diy (uk.d-i-y) For the discussion of all topics related to diy (do-it-yourself) in the UK. All levels of experience and proficency are welcome to join in to ask questions or offer solutions.

 
 
LinkBack Thread Tools Search this Thread Display Modes
Prev Previous Post   Next Post Next
  #1   Report Post  
Junior Member
 
Location: Ireland
Posts: 14
Default Stud Wall for Shed - Bracing and Spacing

So I'm building a timber framed and metal sheet cladded garden shed. It will be approx 6m x 3m x 2.5m, constructed from 4 x 2s and bolted down onto a concrete pad. The cladding sheets are just under a metre in width.

Question - How closely should I space the studs? Should the studs coincide with the edges of the metal cladding so that the vertical edges of the cladding can be screwed to them rather than just screwing adjacent sheets together with short screws? Would 1 metre be too far apart to space the studs?

Do I need to brace the stud walls or would the metal sheets provide sufficient bracing to stiffen everything up?

Edit: The cladding manufacturer suggests that aligning studs with overlaps of adjacent sheets is unnecessary and stitcher screws will do the job ok.

If I add noggings which would be staggered up and down along the wall, what's the best way of locating these noggings when I'm fixing the sheets so I can screw and not miss. Is it better to measure up from the bottom plate and mark a line, or use a square from the edge of the sheet and mark a line on it?

Last edited by Eugbug : September 6th 16 at 04:45 PM
 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Metal siding and stud spacing on walls stryped[_3_] Home Repair 11 April 28th 10 02:23 PM
Bracing a short wall Ivan Vegvary Woodworking 5 August 11th 08 01:23 PM
Shed pier spacing C Miller Woodworking 5 July 7th 06 04:04 AM
bracing wall query [email protected] UK diy 3 May 23rd 06 02:16 PM
Soil pipe of elliptical or rectangular cross section. To fit within stud 70mm wall spacing. Does such a product exist? Peter UK diy 6 January 26th 05 11:02 PM