Steven Briggs
 
Posts: n/a
Default Screwfix Volex CU's

Anyone seen/used one of the Volex split load CU's listed by screwfix.
I'm looking to get the 12 way one, but the split is ambiguous.
Text says split 6+6, photo looks to be split 8+4. The later would be
better for me, with more fixed appliance and lighting circuits than
socket circuits.
Or is it flexible, i.e. cut your own live busbar to suit?

Other suitable CU recommendations welcome.

Ta.

--
Steven Briggs


  #2   Report Post  
Toby
 
Posts: n/a
Default Screwfix Volex CU's

Steven Briggs wrote:
Anyone seen/used one of the Volex split load CU's listed by screwfix.
I'm looking to get the 12 way one, but the split is ambiguous.
Text says split 6+6, photo looks to be split 8+4. The later would be
better for me, with more fixed appliance and lighting circuits than
socket circuits.
Or is it flexible, i.e. cut your own live busbar to suit?

Other suitable CU recommendations welcome.

Ta.


The Clipsal Screwfix one in clearance is 10way cut to suit 5/5, 6/4, 7/3
etc.

--
Toby.

'One day son, all this will be finished'


  #3   Report Post  
Steven Briggs
 
Posts: n/a
Default Screwfix Volex CU's

In message , Toby
writes
Steven Briggs wrote:
Anyone seen/used one of the Volex split load CU's listed by screwfix.
I'm looking to get the 12 way one, but the split is ambiguous.
Text says split 6+6, photo looks to be split 8+4. The later would be
better for me, with more fixed appliance and lighting circuits than
socket circuits.
Or is it flexible, i.e. cut your own live busbar to suit?

Other suitable CU recommendations welcome.

Ta.


The Clipsal Screwfix one in clearance is 10way cut to suit 5/5, 6/4, 7/3
etc.

Need 11 circuits, 4 on the RCD.

This one is a bargain, C/W 10 MCB's for 59.99
http://www.screwfix.com/app/sfd/cat/...18334&id=82204

This _looks_ to be the same, without MCB's, for, er, 59.99.
http://www.screwfix.com/app/sfd/cat/...18334&id=82031

--
Steven Briggs


  #4   Report Post  
Andy Hall
 
Posts: n/a
Default Screwfix Volex CU's

On Sat, 15 Nov 2003 17:09:36 +0000, Steven Briggs
wrote:

Anyone seen/used one of the Volex split load CU's listed by screwfix.
I'm looking to get the 12 way one, but the split is ambiguous.
Text says split 6+6, photo looks to be split 8+4. The later would be
better for me, with more fixed appliance and lighting circuits than
socket circuits.
Or is it flexible, i.e. cut your own live busbar to suit?

Other suitable CU recommendations welcome.

Ta.


MK Sentry Ones come with a bus bar that you can cut.



..andy

To email, substitute .nospam with .gl
  #5   Report Post  
Kalico
 
Posts: n/a
Default Screwfix Volex CU's

"Steven Briggs" wrote in message
...
[snip]

The Clipsal Screwfix one in clearance is 10way cut to suit 5/5, 6/4, 7/3
etc.

Need 11 circuits, 4 on the RCD.

This one is a bargain, C/W 10 MCB's for 59.99
http://www.screwfix.com/app/sfd/cat/...18334&id=82204

It is a bargain - buy one.
Rob




  #6   Report Post  
Martin Angove
 
Posts: n/a
Default Screwfix Volex CU's

In message ,
"Kalico" wrote:

"Steven Briggs" wrote in message
...
[snip]

The Clipsal Screwfix one in clearance is 10way cut to suit 5/5, 6/4, 7/3
etc.

Need 11 circuits, 4 on the RCD.

This one is a bargain, C/W 10 MCB's for 59.99
http://www.screwfix.com/app/sfd/cat/...18334&id=82204

It is a bargain - buy one.
Rob


Definitely. Used a previous version of this Volex at my last house, and
am currently rewiring with this very model. Comes with 40A, 4x32A,
2x16A, 3x6A MCBs, 100A main switch, 63A/30mA RCD. I need a 20A radial
and only 2x6A so bought an extra MCB at the same time. I dare say I'll
use the extra 6A sometime.

Busbar is supplied uncut and unfitted - just remember to make *two* cuts
in order to leave a gap between the RCD and non-RCD sides, unless you
are sure you only need 11 ways when you really should cut off the unused
bit of busbar. Also supplied with a "This installation or part of it..."
sticker and several printed and blank circuit ident labels.

The split load kit is supplied fitted, and it seems to be well enough
designed. It's the N feed from the main switch I'm having trouble with
- it is solid enamelled copper and snakes across the very place the
incomers have to be :-/ Don't forget to check factory fitted components
- the earthing bar was loose in mine.

There's a reasonable, though not overly generous, amount of wiring space
for circuit wires above the MCBs, but the knock-outs in the top face
(where most of my wires will be entering) are decidedly stingy. I've had
to "enlarge" them quite considerably. There are rather more knockouts in
the bottom face, and if you are lucky enough to be wiring from behind,
there are some quite generous holes there.

Only two things I don't understand:

1: Why the unpopulated version is exactly the same price as the one with
10x MCBs.

2: Why most split boards these days come with main switch at far left,
and RCD at far right. The previous version of this board I mentioned had
the RCD in the middle, and flexible split-load cables, so that you could
"read" the board left to right.

HTH

Hwyl!

M.

--
Martin Angove: http://www.tridwr.demon.co.uk/
Don't fight technology, live with it: http://www.livtech.co.uk/
.... SEGA and Nintendo are combining, they call it Windows NT
  #7   Report Post  
Steven Briggs
 
Posts: n/a
Default Screwfix Volex CU's

In message , Martin Angove
writes
Definitely. Used a previous version of this Volex at my last house, and
am currently rewiring with this very model. Comes with 40A, 4x32A,
2x16A, 3x6A MCBs, 100A main switch, 63A/30mA RCD. I need a 20A radial
and only 2x6A so bought an extra MCB at the same time. I dare say I'll
use the extra 6A sometime.

Busbar is supplied uncut and unfitted - just remember to make *two* cuts
in order to leave a gap between the RCD and non-RCD sides, unless you
are sure you only need 11 ways when you really should cut off the unused
bit of busbar. Also supplied with a "This installation or part of it..."
sticker and several printed and blank circuit ident labels.

The split load kit is supplied fitted, and it seems to be well enough
designed. It's the N feed from the main switch I'm having trouble with
- it is solid enamelled copper and snakes across the very place the
incomers have to be :-/ Don't forget to check factory fitted components
- the earthing bar was loose in mine.

There's a reasonable, though not overly generous, amount of wiring space
for circuit wires above the MCBs, but the knock-outs in the top face
(where most of my wires will be entering) are decidedly stingy. I've had
to "enlarge" them quite considerably. There are rather more knockouts in
the bottom face, and if you are lucky enough to be wiring from behind,
there are some quite generous holes there.

Only two things I don't understand:

1: Why the unpopulated version is exactly the same price as the one with
10x MCBs.

2: Why most split boards these days come with main switch at far left,
and RCD at far right. The previous version of this board I mentioned had
the RCD in the middle, and flexible split-load cables, so that you could
"read" the board left to right.

HTH

Hwyl!

M.

Thanks Martin. Just what I needed to know.
Most of my wiring will be from below, so should work out OK.
As to the price, well must be to done with that extra space dimension
associated with mail-order!

--
Steven Briggs


  #8   Report Post  
Dave Stanton
 
Posts: n/a
Default Screwfix Volex CU's


2: Why most split boards these days come with main switch at far left, and
RCD at far right. The previous version of this board I mentioned had the
RCD in the middle, and flexible split-load cables, so that you could
"read" the board left to right.


Wylex NH series CU come with main incomer on right.

Dave

--
And you were born knowing all about ms windows....??

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Volex or GE split load consumer unit? Kalico UK diy 4 November 4th 03 12:25 PM
Screwfix foam gun problems! Steve North UK diy 1 September 23rd 03 03:37 PM
Screwfix :-( Ian UK diy 13 September 3rd 03 06:15 PM
Screwfix Security drivers Grunff UK diy 7 July 5th 03 01:10 PM
Screwfix Ferm Jigsaw Cal Mac UK diy 4 July 5th 03 12:56 PM


All times are GMT +1. The time now is 06:58 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"