Home Repair (alt.home.repair) For all homeowners and DIYers with many experienced tradesmen. Solve your toughest home fix-it problems.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 100
Default Honda Co-Generation Unit

Hi,

I was just wondering if in the USA anyone has one of these units? What
it is is a small One Cylinder engine, with electrical power generation
(1kw) and hot water heater heating (2.8 kw).

It is sort of efficient in that it unlike normal standby power
generation, alot of the heat is used for heating and hot water, just
line he Steam heat supplied in Manhattan New York.

Best, Mike.



http://world.honda.com/news/2004/c041020.html
  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 6,199
Default Honda Co-Generation Unit

On Jan 3, 11:04�am, hobbes wrote:
Hi,

I was just wondering if in the USA anyone has one of these units? What
it is is a small One Cylinder engine, with electrical power generation
(1kw) and hot water heater heating (2.8 kw).

It is sort of efficient in that it unlike normal standby power
generation, alot of the heat is used for heating and hot water, just
line he Steam heat supplied in Manhattan New York.

Best, Mike.

http://world.honda.com/news/2004/c041020.html


its a interesting concept. but how practical is it other than for
emergencies?
  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 4,500
Default Honda Co-Generation Unit

On Jan 3, 12:06Â*pm, " wrote:
On Jan 3, 11:04�am, hobbes wrote:

Hi,


I was just wondering if in the USA anyone has one of these units? What
it is is a small One Cylinder engine, with electrical power generation
(1kw) and hot water heater heating (2.8 kw).


It is sort of efficient in that it unlike normal standby power
generation, alot of the heat is used for heating and hot water, just
line he Steam heat supplied in Manhattan New York.


Best, Mike.


http://world.honda.com/news/2004/c041020.html


its a interesting concept. but how practical is it other than for
emergencies?



I'm not even sure how this widget is even designed to operate. They
talk about it being used an average of 10 hours a day in a typical
Japanese home, which makes it sound as if it's there to supplement the
normal electric demand. It only produces 1KW, which is very small.
The traditional emergency stationary backup units for homes are many
times that. Plus, Japanese homes are typically much smaller than a US
home.
  #4   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 6,199
Default Honda Co-Generation Unit

On Jan 3, 12:17Â*pm, wrote:
On Jan 3, 12:06Â*pm, " wrote:





On Jan 3, 11:04�am, hobbes wrote:


Hi,


I was just wondering if in the USA anyone has one of these units? What
it is is a small One Cylinder engine, with electrical power generation
(1kw) and hot water heater heating (2.8 kw).


It is sort of efficient in that it unlike normal standby power
generation, alot of the heat is used for heating and hot water, just
line he Steam heat supplied in Manhattan New York.


Best, Mike.


http://world.honda.com/news/2004/c041020.html


its a interesting concept. but how practical is it other than for
emergencies?


I'm not even sure how this widget is even designed to operate. Â*They
talk about it being used an average of 10 hours a day in a typical
Japanese home, which makes it sound as if it's there to supplement the
normal electric demand. Â*It only produces 1KW, which is very small.
The traditional emergency stationary backup units for homes are many
times that. Â*Plus, Japanese homes are typically much smaller than a US
home.- Hide quoted text -

- Show quoted text -


i wonder if it includes a sychronous inverter allowing the meter to
turn backwards? selling power back to the utility company.

certinally coal nuclear and oil fired plants with thoise big cooling
towers waste lots of heat........

  #6   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 8,803
Default Honda Co-Generation Unit


"hobbes" wrote in message
...
Hi,

I was just wondering if in the USA anyone has one of these units? What
it is is a small One Cylinder engine, with electrical power generation
(1kw) and hot water heater heating (2.8 kw).

It is sort of efficient in that it unlike normal standby power
generation, alot of the heat is used for heating and hot water, just
line he Steam heat supplied in Manhattan New York.

Best, Mike.



http://world.honda.com/news/2004/c041020.html


At 85% total efficiency, a 90+ furnace extracts more useful energy from the gas
used.


  #7   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 4,926
Default Honda Co-Generation Unit

On Jan 3, 10:04*am, hobbes wrote:
Hi,

I was just wondering if in the USA anyone has one of these units? What
it is is a small One Cylinder engine, with electrical power generation
(1kw) and hot water heater heating (2.8 kw).

It is sort of efficient in that it unlike normal standby power
generation, alot of the heat is used for heating and hot water, just
line he Steam heat supplied in Manhattan New York.

Best, Mike.

http://world.honda.com/news/2004/c041020.html


If you were off the grid it would be interesting try
alt.energy.homepower for off grid people that know about these
things. I believe it is very expensive.
  #8   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 6,746
Default Honda Co-Generation Unit

ransley wrote:

On Jan 3, 10:04 am, hobbes wrote:
Hi,

I was just wondering if in the USA anyone has one of these units? What
it is is a small One Cylinder engine, with electrical power generation
(1kw) and hot water heater heating (2.8 kw).

It is sort of efficient in that it unlike normal standby power
generation, alot of the heat is used for heating and hot water, just
line he Steam heat supplied in Manhattan New York.

Best, Mike.

http://world.honda.com/news/2004/c041020.html


If you were off the grid it would be interesting try
alt.energy.homepower for off grid people that know about these
things. I believe it is very expensive.


If it has the Honda name, it's inherently expensive.

I believe at lest some of the folks on the a.e.h. group are in northern
"heat all the time" climates and do similar homebrew co-gen setups.
  #9   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 8,803
Default Honda Co-Generation Unit


"ransley" wrote in message
...
On Jan 3, 10:04 am, hobbes wrote:
Hi,

I was just wondering if in the USA anyone has one of these units? What
it is is a small One Cylinder engine, with electrical power generation.
(1kw) and hot water heater heating (2.8 kw).

It is sort of efficient in that it unlike normal standby power
generation, alot of the heat is used for heating and hot water, just
line he Steam heat supplied in Manhattan New York.

Best, Mike.

http://world.honda.com/news/2004/c041020.html


If you were off the grid it would be interesting try
alt.energy.homepower for off grid people that know about these
things. I believe it is very expensive.


How many people off-grid have natural gas?



  #10   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 6,746
Default Honda Co-Generation Unit

Bob F wrote:

"ransley" wrote in message
...
On Jan 3, 10:04 am, hobbes wrote:
Hi,

I was just wondering if in the USA anyone has one of these units? What
it is is a small One Cylinder engine, with electrical power generation.
(1kw) and hot water heater heating (2.8 kw).

It is sort of efficient in that it unlike normal standby power
generation, alot of the heat is used for heating and hot water, just
line he Steam heat supplied in Manhattan New York.

Best, Mike.

http://world.honda.com/news/2004/c041020.html


If you were off the grid it would be interesting try
alt.energy.homepower for off grid people that know about these
things. I believe it is very expensive.


How many people off-grid have natural gas?


Many have LP, and an engine that will run on natural gas will also run
on LP with minimal changes.


  #12   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 775
Default Honda Co-Generation Unit

dpb wrote:
wrote:
certinally coal nuclear and oil fired plants with thoise big cooling
towers waste lots of heat........


I'll wager their overall thermal efficiency is higher than these units.


Sure... 100% is the theoretical limit for cogen. The Intelligen 5 kW unit
got a combined 93% efficiency ((heat+elec output)/fuel heating value.)

Nick

  #13   Report Post  
Posted to alt.home.repair
M Q M Q is offline
external usenet poster
 
Posts: 257
Default Honda Co-Generation Unit

hobbes wrote:

Hi,

I was just wondering if in the USA anyone has one of these units? What
it is is a small One Cylinder engine, with electrical power generation
(1kw) and hot water heater heating (2.8 kw).

It is sort of efficient in that it unlike normal standby power
generation, alot of the heat is used for heating and hot water, just
line he Steam heat supplied in Manhattan New York.



I am not sure if co-generation is that useful with internal combustion
engines. Usually it seems to be used with steam turbine power conversion
where the process necessarily has a lot of waste heat which normally
goes to a cooling tower or to a river.
The cooling tower portion of the power plant is replaced by the space heating
and water heating needs of a local town or city.

Does anyone know if internal combustion engines produce as significant
portion of waste heat as steam turbines?

  #14   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 6,746
Default Honda Co-Generation Unit

M Q wrote:

hobbes wrote:

Hi,

I was just wondering if in the USA anyone has one of these units? What
it is is a small One Cylinder engine, with electrical power generation
(1kw) and hot water heater heating (2.8 kw).

It is sort of efficient in that it unlike normal standby power
generation, alot of the heat is used for heating and hot water, just
line he Steam heat supplied in Manhattan New York.


I am not sure if co-generation is that useful with internal combustion
engines. Usually it seems to be used with steam turbine power conversion
where the process necessarily has a lot of waste heat which normally
goes to a cooling tower or to a river.
The cooling tower portion of the power plant is replaced by the space heating
and water heating needs of a local town or city.

Does anyone know if internal combustion engines produce as significant
portion of waste heat as steam turbines?


Thermal efficiency of ICEs is worse than steam turbines. As was noted
further up in the post, the electrical output is 1kW while the thermal
output is 2.8kW on the unit in question.
  #16   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 4,926
Default Honda Co-Generation Unit

On Jan 3, 1:11*pm, "Bob F" wrote:
"ransley" wrote in message

news:a9b2317a-e0e1-4359-9643-3cb8a9990__BEGIN_MASK_n#9g02mG7!__...__END_MASK_i ...





On Jan 3, 10:04 am, hobbes wrote:
Hi,


I was just wondering if in the USA anyone has one of these units? What
it is is a small One Cylinder engine, with electrical power generation..
(1kw) and hot water heater heating (2.8 kw).


It is sort of efficient in that it unlike normal standby power
generation, alot of the heat is used for heating and hot water, just
line he Steam heat supplied in Manhattan New York.


Best, Mike.


http://world.honda.com/news/2004/c041020.html

If you were off the grid it would be interesting try
alt.energy.homepower *for off grid people that know about these
things. I believe it is very expensive.


How many people off-grid have natural gas?- Hide quoted text -

- Show quoted text -


They get propane
  #17   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 361
Default Honda Co-Generation Unit

dpb writes:
wrote:


certinally coal nuclear and oil fired plants with thoise big cooling
towers waste lots of heat........


I'll wager their overall thermal efficiency is higher than these units.
You can't escape the 2nd law...


A thermal power plant's useful output is electricity only. It's hard to
generate electricity from heat, and a lot of the heat ends up being
dumped by the cooling tower in order to create a larger temperature
differential to boost the efficiency of the turbines.

With a cogeneration unit, the heat output is counted as useful output
instead of waste heat when calculating efficiency. But that's fair only
if you actually need the water heating.

So the cogen unit is almost certainly less efficient at generating
electricity than the large utility unit, if that's the only output you
count. The cogen unit is also probably less efficient at heating water
than a high-efficiency dedicated water heater, if you only measure water
temperature rise as useful output. It's only when you count *both*
water heat and electricity that you end up with the high quoted
efficiency.

Dave
  #18   Report Post  
Posted to alt.home.repair
dpb dpb is offline
external usenet poster
 
Posts: 12,595
Default Honda Co-Generation Unit

Dave Martindale wrote:
dpb writes:
wrote:


certinally coal nuclear and oil fired plants with thoise big cooling
towers waste lots of heat........


I'll wager their overall thermal efficiency is higher than these units.
You can't escape the 2nd law...


A thermal power plant's useful output is electricity only.


Not necessarily, some of them use waste heat as well or process steam
albeit not a tremendous number.

It's hard to
generate electricity from heat, and a lot of the heat ends up being
dumped by the cooling tower in order to create a larger temperature
differential to boost the efficiency of the turbines.


It isn't heat that is used (directly) to generate the electricity; the
heat is used to make steam.

The use of a cooling tower is simply one alternative--other plants use
water exchangers.

But in the end, yes, there has to be an ultimate heat sink and the
colder it is, the better.

But, just as a central generating unit uses the best ultimate
temperature sink, they also pull vacuum on the turbine exhaust.

Plus, it might even operate the boiler side at supercritical. All of
these features far exceed the thermal efficiency of any little
generating unit.


With a cogeneration unit, the heat output is counted as useful output
instead of waste heat when calculating efficiency. But that's fair only
if you actually need the water heating.


Precisely my point -- when posting that the cooling towers indicate that
the central generating station is less efficient, that implied the
comparison to the generation. Ain't no little pos generator such as
this going to come close for the generation side efficiency which is all
I was referring to.
--
  #19   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 6,199
Default Honda Co-Generation Unit


With a cogeneration unit, the heat output is counted as useful output
instead of waste heat when calculating efficiency. �But that's fair only
if you actually need the water heating.


Precisely my point -- when posting that the cooling towers indicate that
the central generating station is less efficient, that implied the
comparison to the generation. �Ain't no little pos generator such as
this going to come close for the generation side efficiency which is all
I was referring to.
--


true,

another thing people living off grid in rural places may have a gas
well, around here they are pretty common.....

sometimes they wqere drilled for oil many years ago, when production
decreases the original property owner pays a fee to buy the well, for
its natural gas.

i met a guy that did just that, he heated his home etc off free
natural gas, although he wasnt off grid. around karns city pa.

  #20   Report Post  
Posted to alt.home.repair
dpb dpb is offline
external usenet poster
 
Posts: 12,595
Default Honda Co-Generation Unit

wrote:
With a cogeneration unit, the heat output is counted as useful output
instead of waste heat when calculating efficiency. �But that's fair only
if you actually need the water heating.

Precisely my point -- when posting that the cooling towers indicate that
the central generating station is less efficient, that implied the
comparison to the generation. �Ain't no little pos generator such as
this going to come close for the generation side efficiency which is all
I was referring to.
--


true,

another thing people living off grid in rural places may have a gas
well, around here they are pretty common.....

sometimes they wqere drilled for oil many years ago, when production
decreases the original property owner pays a fee to buy the well, for
its natural gas.

i met a guy that did just that, he heated his home etc off free
natural gas, although he wasnt off grid. around karns city pa.


Very few any more that still allow a free tap if the well is in
production at all. Totally abandoned and expired lease, but how many of
those are there...

Until about 10 years ago or so, we had an uncharged tap off the main
cross-country pipeline that was a condition grandfather made when
negotiating right-of-way. That lasted for 60 years or so, but no more.
At least we weren't cut off entirely which is what most of the
lease-holders have done for the single-well taps. It's been a major
problem for those who relied on it for irrigation wells, grain driers,
and other agricultural needs even more than simply household heating.

--




  #21   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 212
Default Honda Co-Generation Unit

Does anyone know if internal combustion engines produce as significant
portion of waste heat as steam turbines?


Well, I do know that some combustion turbine (my preferred term over "gas
turbine") plants feed the turbine exhaust into a boiler (aka "heat recovery
steam generator") and then the steam can either go to a steam turbine
(combined cycle) for more electricity or be used for heating or as process
steam (co-generation).

Previously turbine power plants were used mostly for peaking plants not for
base load but combined cycle ups the efficiency enough to make them useful
for base load despite using premium fuels (lighter oil or natural gas).
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Wind electric generation question Jim-Poncin Home Repair 7 February 2nd 06 10:19 PM
Generation X helpers Robert Allison Woodworking 7 April 2nd 05 08:59 PM
next generation of power tools S R Woodworking 14 January 14th 05 03:45 AM
Router Lifts - the next generation? Never Enough Money Woodworking 57 October 26th 04 07:49 PM


All times are GMT +1. The time now is 08:43 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"