Howdy all. Does anyone have a tip for working in an attic covered with
cellulose insulation? We have knob and tube wiring in the attic covered with mounds of insulation at least 18 inches thick. I need a way to get the cellulose insulation out of the way so I can trace the wiring and inspect/replace it. I can't just shovel the stuff out of the way because of the wiring. I'm tempted to take my leaf blower up there this weekend and see how that works. Anyway, I'm open for suggestions. Thanks, Felder |
#2
Posted to alt.home.repair
|
|||
|
|||
Working in Cellulose Insulation...
Felder wrote:
Howdy all. Does anyone have a tip for working in an attic covered with cellulose insulation? We have knob and tube wiring in the attic covered with mounds of insulation at least 18 inches thick. I need a way to get the cellulose insulation out of the way so I can trace the wiring and inspect/replace it. I can't just shovel the stuff out of the way because of the wiring. I'm tempted to take my leaf blower up there this weekend and see how that works. Anyway, I'm open for suggestions. Thanks, Felder Argh! Leaf blower will make a huge mess and dust throughout the house, I bet. In addition, you will need substantial respirator protection. Consider a fan pump fresh air into the work area as well. How about experimenting on a smaller scale with a vacuum cleaner connected to blow? If not a shovel, maybe a hoe? Technically, cellulose shouldn't cover K&T. However, one large city (Philly, I think) did a study involving a large number of city houses retrofitted with cellulose and found no problems. Link he http://www.waptac.org/doclib/openfile.asp?id=605 Jim |
#3
Posted to alt.home.repair
|
|||
|
|||
Working in Cellulose Insulation...
On Aug 21, 7:51 pm, Felder wrote:
Howdy all. Does anyone have a tip for working in an attic covered with cellulose insulation? We have knob and tube wiring in the attic covered with mounds of insulation at least 18 inches thick. I need a way to get the cellulose insulation out of the way so I can trace the wiring and inspect/replace it. I can't just shovel the stuff out of the way because of the wiring. I'm tempted to take my leaf blower up there this weekend and see how that works. Anyway, I'm open for suggestions. Thanks, Felder ahhhhhhh welcome to my nightmare. well a dust pan fits between most bays nicely and maybe a bunch of trash bags, bag some and remove then pile some of it in areas already inspected or void of wiring. hmmm gonna be some cussin goin on. |
#4
Posted to alt.home.repair
|
|||
|
|||
Working in Cellulose Insulation...
Felder wrote:
Howdy all. Does anyone have a tip for working in an attic covered with cellulose insulation? We have knob and tube wiring in the attic covered with mounds of insulation at least 18 inches thick. I need a way to get the cellulose insulation out of the way so I can trace the wiring and inspect/replace it. I can't just shovel the stuff out of the way because of the wiring. I'm tempted to take my leaf blower up there this weekend and see how that works. Anyway, I'm open for suggestions. Thanks, Felder Can you just scoop it with gloved hands? How about a large shop vac? BTW, insulation over K&T wiring maybe kind of iffy. I am not sure, but you may want to check into that. It seems that NEC prohibits insulation over "concealed knob and tube" (392.12 NEC 2005), but seems to be silent on "open wiring on insulators" (Article 398 NEC 2005). Various jurisdictions seem to sometimes have different rules than NEC. |
#5
Posted to alt.home.repair
|
|||
|
|||
Working in Cellulose Insulation...
"Felder" wrote in message ups.com... Howdy all. Does anyone have a tip for working in an attic covered with cellulose insulation? We have knob and tube wiring in the attic covered with mounds of insulation at least 18 inches thick. I need a way to get the cellulose insulation out of the way so I can trace the wiring and inspect/replace it. I can't just shovel the stuff out of the way because of the wiring. I'm tempted to take my leaf blower up there this weekend and see how that works. Anyway, I'm open for suggestions. Thanks, Felder A contractor quoted me $2000. I bought a Harbor Freight dust collector for $180. I stuck the blower in the center of my attic and ran 30 feet of 4 inch pipe out the end of my attic. I hooked up two sets of vacuum hoses to the blower and my wife and I vacuumed the attic clean in two days. We shoveled the pile of insulation into lawn bags and took it to the dump. |
#6
Posted to alt.home.repair
|
|||
|
|||
Working in Cellulose Insulation...
Why'd you throw it away? you could have blown it back in when you were
done. steve "Pat" wrote in message ... "Felder" wrote in message ups.com... Howdy all. Does anyone have a tip for working in an attic covered with cellulose insulation? We have knob and tube wiring in the attic covered with mounds of insulation at least 18 inches thick. I need a way to get the cellulose insulation out of the way so I can trace the wiring and inspect/replace it. I can't just shovel the stuff out of the way because of the wiring. I'm tempted to take my leaf blower up there this weekend and see how that works. Anyway, I'm open for suggestions. Thanks, Felder A contractor quoted me $2000. I bought a Harbor Freight dust collector for $180. I stuck the blower in the center of my attic and ran 30 feet of 4 inch pipe out the end of my attic. I hooked up two sets of vacuum hoses to the blower and my wife and I vacuumed the attic clean in two days. We shoveled the pile of insulation into lawn bags and took it to the dump. |
#7
Posted to alt.home.repair
|
|||
|
|||
Working in Cellulose Insulation...
"Steve Barker" wrote in message ... Why'd you throw it away? you could have blown it back in when you were done. I considered it. Decided to have new fiberglass installed after the work is done. As it turned out it would have been rained on anyway. I put the blower back in the box and sold it for almost as much as I paid for it. Made the job very inexpensive. |
#8
Posted to alt.home.repair
|
|||
|
|||
Working in Cellulose Insulation...
"Steve Barker" wrote in message ... Why'd you throw it away? you could have blown it back in when you were done. Tried to give it away. No one wanted it. |
#9
Posted to alt.home.repair
|
|||
|
|||
Working in Cellulose Insulation...
"Felder" wrote in message ups.com... Howdy all. Does anyone have a tip for working in an attic covered with cellulose insulation? We have knob and tube wiring in the attic covered with mounds of insulation at least 18 inches thick. I need a way to get the cellulose insulation out of the way so I can trace the wiring and inspect/replace it. I can't just shovel the stuff out of the way because of the wiring. I'm tempted to take my leaf blower up there this weekend and see how that works. Anyway, I'm open for suggestions. Broom. |
#10
Posted to alt.home.repair
|
|||
|
|||
Working in Cellulose Insulation...
On Jan 29, 2:11�pm, "Bob F" wrote:
"Felder" wrote in message ups.com... Howdy all. Does anyone have a tip for working in an attic covered with cellulose insulation? We have knob and tube wiring in the attic covered with mounds of insulation at least 18 inches thick. I need a way to get the cellulose insulation out of the way so I can trace the wiring and inspect/replace it. I can't just shovel the stuff out of the way because of the wiring. I'm tempted to take my leaf blower up there this weekend and see how that works. Anyway, I'm open for suggestions. Broom. YOU SHOULD NEVER COVER KNOB AND TUBE WITH ANY INSULATION EVER!! Its past time to rewire your home, and if you have a house fire its very possible insurance wouldnt cover your loss |
#11
Posted to alt.home.repair
|
|||
|
|||
Working in Cellulose Insulation...
" wrote:
On Jan 29, 2:11�pm, "Bob F" wrote: "Felder" wrote in message ups.com... Howdy all. Does anyone have a tip for working in an attic covered with cellulose insulation? We have knob and tube wiring in the attic covered with mounds of insulation at least 18 inches thick. I need a way to get the cellulose insulation out of the way so I can trace the wiring and inspect/replace it. I can't just shovel the stuff out of the way because of the wiring. I'm tempted to take my leaf blower up there this weekend and see how that works. Anyway, I'm open for suggestions. Broom. YOU SHOULD NEVER COVER KNOB AND TUBE WITH ANY INSULATION EVER!! Its past time to rewire your home, and if you have a house fire its very possible insurance wouldnt cover your loss Second that, *HUGE* fire risk there. K&T wiring was and still is quite safe - when it is left as it was when it was installed - all the risk of K&T comes from people modifying it, over fusing it, burying it in insulation and other changes. At this point the only practical thing to do is to vacuum it out with the biggest shop vac you can get (rent a true industrial one) and empty the vac'd insulation into some really big moving boxes for temporary storage. After removing all the insulation, remove all the K&T wiring and replace it to current code. After the wiring issues are resolved, rent an insulation blower and plow the insulation back into the attic. Remember your PPE - Goggles and respirator, as well as gloves, knee pads and a hard hat (roofing nails to the head hurt). |
#12
Posted to alt.home.repair
|
|||
|
|||
Working in Cellulose Insulation...
On Jan 29, 5:43Â*pm, "Pete C." wrote:
" wrote: On Jan 29, 2:11�pm, "Bob F" wrote: "Felder" wrote in message oups.com... Howdy all. Does anyone have a tip for working in an attic covered with cellulose insulation? We have knob and tube wiring in the attic covered with mounds of insulation at least 18 inches thick. I need a way to get the cellulose insulation out of the way so I can trace the wiring and inspect/replace it. I can't just shovel the stuff out of the way because of the wiring. I'm tempted to take my leaf blower up there this weekend and see how that works. Anyway, I'm open for suggestions. Broom. YOU SHOULD NEVER COVER KNOB AND TUBE WITH ANY INSULATION EVER!! Its past time to rewire your home, and if you have a house fire its very possible insurance wouldnt cover your loss Second that, *HUGE* fire risk there. K&T wiring was and still is quite safe - when it is left as it was when it was installed - all the risk of K&T comes from people modifying it, over fusing it, burying it in insulation and other changes. At this point the only practical thing to do is to vacuum it out with the biggest shop vac you can get (rent a true industrial one) and empty the vac'd insulation into some really big moving boxes for temporary storage. After removing all the insulation, remove all the K&T wiring and replace it to current code. After the wiring issues are resolved, rent an insulation blower and plow the insulation back into the attic. Remember your PPE - Goggles and respirator, as well as gloves, knee pads and a hard hat (roofing nails to the head hurt).- Hide quoted text - - Show quoted text - and check all the walls too. some insurance companies dont cover K&T wiring and it can be very hard to sell a home with K&T because the buyer cant get homeowners insurance |
#13
Posted to alt.home.repair
|
|||
|
|||
Working in Cellulose Insulation...
|
#14
Posted to alt.home.repair
|
|||
|
|||
Working in Cellulose Insulation...
Bob F wrote:
"Felder" wrote in message .... there this weekend and see how that works. Anyway, I'm open for suggestions. Broom. Don't suppose responding here in January will help OP much for a coming weekend last August... -- |
#15
Posted to alt.home.repair
|
|||
|
|||
Working in Cellulose Insulation...
Pete C. wrote:
" wrote: On Jan 29, 2:11�pm, "Bob F" wrote: "Felder" wrote in message ups.com... Howdy all. Does anyone have a tip for working in an attic covered with cellulose insulation? We have knob and tube wiring in the attic covered with mounds of insulation at least 18 inches thick. I need a way to get the cellulose insulation out of the way so I can trace the wiring and inspect/replace it. I can't just shovel the stuff out of the way because of the wiring. I'm tempted to take my leaf blower up there this weekend and see how that works. Anyway, I'm open for suggestions. Broom. YOU SHOULD NEVER COVER KNOB AND TUBE WITH ANY INSULATION EVER!! Its past time to rewire your home, and if you have a house fire its very possible insurance wouldnt cover your loss Second that, *HUGE* fire risk there. K&T wiring was and still is quite safe - when it is left as it was when it was installed - all the risk of K&T comes from people modifying it, over fusing it, burying it in insulation and other changes. .. It has been a code violation to insulation after about 1987 (394.12-5). Never cover? Huge fire risk? http://www.waptac.org/sp.asp?id=7190 (originally posted by Phil Munro) is a report to the Illinois Department of Commerce and Community Affairs on adding building insulation around existing K&T wiring. No record of hazard was found in the large number of K&T installations that had insulation added around them. Also addresses how some jurisdictions have handled the code aspects. If the post was timely, I would suggest moving cellulose with a large piece of cardboard. (good eye Duane) -- bud-- |
#17
Posted to alt.home.repair
|
|||
|
|||
Working in Cellulose Insulation...
The problem with this theory is that it's never been proven. There's never
been a fire that was proven to be because of K&T wiring that was covered by insulation. It sounds good on paper and gave the NEC boys something else to screw people over about, but in all reality, it just doesn't happen. s wrote in message ... K&T was designed for free air flow around conductors at all times. insulation prevents that and can cause overheating and ultimately a fire since connections are soldered in walls, get solder hot enough and it will fail |
#18
Posted to alt.home.repair
|
|||
|
|||
Working in Cellulose Insulation...
"bud--" wrote in message news:762bb$47a03604$4213ea39 Never cover? Huge fire risk? http://www.waptac.org/sp.asp?id=7190 (originally posted by Phil Munro) is a report to the Illinois Department of Commerce and Community Affairs on adding building insulation around existing K&T wiring. No record of hazard was found in the large number of K&T installations that had insulation added around them. Also addresses how some jurisdictions have handled the code aspects. Thanks for that. It's a good read, and could affect me since I'm in Washington. |
#19
Posted to alt.home.repair
|
|||
|
|||
Working in Cellulose Insulation...
If, as the paper said, K&T was typically #12 wire fused for 15 Amps, I can
certainly see why the worry is exagerated. "S. Barker" wrote in message ... The problem with this theory is that it's never been proven. There's never been a fire that was proven to be because of K&T wiring that was covered by insulation. It sounds good on paper and gave the NEC boys something else to screw people over about, but in all reality, it just doesn't happen. s wrote in message ... K&T was designed for free air flow around conductors at all times. insulation prevents that and can cause overheating and ultimately a fire since connections are soldered in walls, get solder hot enough and it will fail |
#20
Posted to alt.home.repair
|
|||
|
|||
Working in Cellulose Insulation...
On Feb 12, 8:04�pm, "Bob F" wrote:
If, as the paper said, K&T was typically #12 wire fused for 15 Amps, I can certainly see why the worry is exagerated. "S. Barker" wrote in message ... The problem with this theory is that it's never been proven. �There's never been a fire that was proven to be because of K&T wiring that was covered by insulation. �It sounds good on paper and gave the NEC boys something else to screw people over about, but in all reality, �it just doesn't happen. s wrote in message ... K&T was designed for free air flow around conductors at all times. insulation prevents that and can cause overheating and ultimately a fire since connections are soldered in walls, get solder hot enough and it will fail- Hide quoted text - - Show quoted text - is it worth the risk of having K&T covered by cellouse? one has no way to know what if any repairs modifications and damage that may have occured over a 100 years or more............... but hey its your home, doesnt effect anyone but you.............. |
#21
Posted to alt.home.repair
|
|||
|
|||
Working in Cellulose Insulation...
wrote:
is it worth the risk of having K&T covered by cellouse? one has no way to know what if any repairs modifications and damage that may have occured over a 100 years or more............... The report to the Illinois Department of Commerce and Community Affairs http://www.waptac.org/sp.asp?id=7190 did not find evidence of a risk. You have not provided a link to a reputable source documenting the risk of K&T in insulation. Or the risk of K&T. Or that rubber insulation burns at a low temperature. Just more FUD. -- bud-- |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Cellulose Insulation without Machine | Home Repair | |||
Insulation - Cellulose over Batts? | Home Repair | |||
cellulose insulation issues | Home Repair | |||
Cellulose insulation ok? | Home Repair | |||
Blown in Cellulose Insulation | Home Ownership |