A/C Outside Fan Not Running
Hi,
I have an air conditioner that has an inside unit and an outside unit. When I turn on the air conditioning the attic fans blow but it only blows warmish air. I know that this is most likely because of a blown fuse or a breaker. Where would I find the fuses and how can I replace them? Thanks! -Keegan |
#2
Posted to alt.home.repair
|
|||
|
|||
A/C Outside Fan Not Running
On May 3, 6:19 am, Keegan wrote:
Hi, I have an air conditioner that has an inside unit and an outside unit. When I turn on the air conditioning the attic fans blow but it only blows warmish air. I know that this is most likely because of a blown fuse or a breaker. Where would I find the fuses and how can I replace them? Thanks! -Keegan There should be a circuit breaker in the AC panel for the outside compressor unit. If it's not marked, it should be easy to spot, typically 40 amp, 240V double breaker. There may also be another fuse located in a weatherproof box outside near the unit. |
#3
Posted to alt.home.repair
|
|||
|
|||
A/C Outside Fan Not Running
If the outside fan isn't running, the compressor may be running
and getting ready to burn out. I'd suggest to call a HVAC repair company. What you know (blown fuse or breaker) might be correct. But I can think of several other things that could be wrong. -- Christopher A. Young You can't shout down a troll. You have to starve them. .. "Keegan" wrote in message ps.com... : Hi, : : I have an air conditioner that has an inside unit and an outside unit. : When I turn on the air conditioning the attic fans blow but it only : blows warmish air. I know that this is most likely because of a blown : fuse or a breaker. : : Where would I find the fuses and how can I replace them? : : Thanks! : : -Keegan : |
#4
Posted to alt.home.repair
|
|||
|
|||
A/C Outside Fan Not Running
I'd be highly suspicious of the starting capacitor.
|
#5
Posted to alt.home.repair
|
|||
|
|||
A/C Outside Fan Not Running
On May 3, 10:26 am, wrote:
I'd be highly suspicious of the starting capacitor. When its on, I don't hear any noise compressor or otherwise. |
#6
Posted to alt.home.repair
|
|||
|
|||
A/C Outside Fan Not Running
90% of the time the condenser fan just needs a little oil after
sitting idle all winter. On 3 May 2007 08:49:56 -0700, Keegan wrote: On May 3, 10:26 am, wrote: I'd be highly suspicious of the starting capacitor. When its on, I don't hear any noise compressor or otherwise. Cheers, Joe |
#7
Posted to alt.home.repair
|
|||
|
|||
A/C Outside Fan Not Running
On 3 May 2007 07:26:22 -0700, wrote:
I'd be highly suspicious of the starting capacitor. That's what went wrong on mine. When that happened, the outside fan world run (indicating it's not the breaker, this unit is wired foe 240V only - no neutral) but the compressor would not. BTW, it's a good idea to learn to recognize the different sounds. The compressor will make a deeper sound. -- Mark Lloyd http://notstupid.laughingsquid.com "Unlike biological evolution. 'intelligent design' is not a genuine scientific theory and, therefore, has no place in the curriculum of our nation's public school classes." -- Ted Kennedy |
#8
Posted to alt.home.repair
|
|||
|
|||
A/C Outside Fan Not Running
On 3 May 2007 08:49:56 -0700, Keegan wrote:
On May 3, 10:26 am, wrote: I'd be highly suspicious of the starting capacitor. When its on, I don't hear any noise compressor or otherwise. Is the thermostat requesting cooling? If so, it could be the relay in the unit, but check the fuse or breaker first. BTW, in my case it's a double-pole breaker in a box outside next to the unit. -- Mark Lloyd http://notstupid.laughingsquid.com "Unlike biological evolution. 'intelligent design' is not a genuine scientific theory and, therefore, has no place in the curriculum of our nation's public school classes." -- Ted Kennedy |
#9
Posted to alt.home.repair
|
|||
|
|||
A/C Outside Fan Not Running
All things being said, if the breakers aren't tripped, you should call a
qualified HVAC repair person to find the problem. It can range from something as simple as a low voltage problem [rat in attic cut control line for example] to something serious [like a burned high voltage connection on the contactor.] And, if the unit needs any cleaning, refrigerant charge adjustment, or oil, he could do it then. -- Zyp "Mark Lloyd" wrote in message news On 3 May 2007 07:26:22 -0700, wrote: I'd be highly suspicious of the starting capacitor. That's what went wrong on mine. When that happened, the outside fan world run (indicating it's not the breaker, this unit is wired foe 240V only - no neutral) but the compressor would not. BTW, it's a good idea to learn to recognize the different sounds. The compressor will make a deeper sound. -- Mark Lloyd http://notstupid.laughingsquid.com "Unlike biological evolution. 'intelligent design' is not a genuine scientific theory and, therefore, has no place in the curriculum of our nation's public school classes." -- Ted Kennedy |
#10
Posted to alt.home.repair
|
|||
|
|||
A/C Outside Fan Not Running
Joe wrote:
90% of the time the condenser fan just needs a little oil after sitting idle all winter. We have a Trane AC and the condenser fan did not run for a while one day. Then it started running again. I think it was the first hot day last year. I had a technician come out and he said that there was nothing wrong with the unit. He said that the only service I should do is to clean the coils with a stream from the garden hose. Should I be oiling the fan on my unit? If so, how do I do it? Thank you in advance for all replies. -- I don't understand why they make gourmet cat foods. I have known many cats in my life and none of them were gourmets. They were all gourmands! |
#11
Posted to alt.home.repair
|
|||
|
|||
A/C Outside Fan Not Running
On May 6, 8:20 am, Daniel Prince wrote:
Joe wrote: 90% of the time the condenser fan just needs a little oil after sitting idle all winter. We have a Trane AC and the condenser fan did not run for a while one day. Then it started running again. I think it was the first hot day last year. I had a technician come out and he said that there was nothing wrong with the unit. He said that the only service I should do is to clean the coils with a stream from the garden hose. Should I be oiling the fan on my unit? If so, how do I do it? Thank you in advance for all replies. No, because like most motors of this type and era, they are sealed and not designed to need or accept oil. If they were meant to be oiled, the tech would have done it. -- I don't understand why they make gourmet cat foods. I have known many cats in my life and none of them were gourmets. They were all gourmands! |
#12
Posted to alt.home.repair
|
|||
|
|||
A/C Outside Fan Not Running
We have a Trane AC and the condenser fan did not run for a while one day. Then it started running again. I think it was the first hot day last year. The fan did not run at all on a hot day? Some upper end units have fan cycle switches that do not allow the fan "outside" to come on until the pressure in the system gets high enough. This is a more efficient setup. Soem fans come on as soon as the compressor starts "most are this way" I had a technician come out and he said that there was nothing wrong with the unit. He said that the only service I should do is to clean the coils with a stream from the garden hose. turn the breaker off first and look inside the coil as well. If you have a double row coil, it will need split and cleaned by a profesional eventually. Not "Joe Bobs service" Should I be oiling the fan on my unit? If so, how do I do it? If the fan motor has a little cap on the side of the bearing housing "end plates" then they are to be removed once a year and about 3-5 drops of oil inserted with a Zoom spout oiler. "It's very light oil" maybe 20 weight. like 3N1 oil. At the beginiing of the cooling season maybe turn the breaker off and take a long then screwdriver and insert it through the fand guard and give the blade a spin. you would be amazed. If the fan turns easily and makes no noise your bearing are probably good. There can be other reasons for failure. Faulty Capaciter, open winding in motor, Shorted wires/windings. Service techs can truely earn the money you pay them.... No, because like most motors of this type and era, they are sealed and not designed to need or accept oil. If they were meant to be oiled, the tech would have done it. Yea, Every tech will do everything perfect. Especially on a Friday after putting in 12 yours and no lunch break. I have had bad days... also |
#13
Posted to alt.home.repair
|
|||
|
|||
A/C Outside Fan Not Running
On May 6, 8:54 am, "Luca" wrote:
We have a Trane AC and the condenser fan did not run for a while one day. Then it started running again. I think it was the first hot day last year. The fan did not run at all on a hot day? Some upper end units have fan cycle switches that do not allow the fan "outside" to come on until the pressure in the system gets high enough. This is a more efficient setup. Soem fans come on as soon as the compressor starts "most are this way" I had a technician come out and he said that there was nothing wrong with the unit. He said that the only service I should do is to clean the coils with a stream from the garden hose. turn the breaker off first and look inside the coil as well. If you have a double row coil, it will need split and cleaned by a profesional eventually. Not "Joe Bobs service" Should I be oiling the fan on my unit? If so, how do I do it? If the fan motor has a little cap on the side of the bearing housing "end plates" then they are to be removed once a year and about 3-5 drops of oil inserted with a Zoom spout oiler. "It's very light oil" maybe 20 weight. like 3N1 oil. At the beginiing of the cooling season maybe turn the breaker off and take a long then screwdriver and insert it through the fand guard and give the blade a spin. you would be amazed. If the fan turns easily and makes no noise your bearing are probably good. There can be other reasons for failure. Faulty Capaciter, open winding in motor, Shorted wires/windings. Service techs can truely earn the money you pay them.... No, because like most motors of this type and era, they are sealed and not designed to need or accept oil. If they were meant to be oiled, the tech would have done it. Yea, Every tech will do everything perfect. Especially on a Friday after putting in 12 yours and no lunch break. I have had bad days... also Not a question of doing "everything" perfect. The service call was specifically for a fan not turning. You'd have to be either totally incompetent or a cheat to not oil a fan that was meant to be oiled under those circumstances. Have you actually seen a residential AC compressor unit in the last couple of decades meant to be oiled once a year? I haven't. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Running an extractor fan for long periods (damp cellar)? | UK diy | |||
running 120V muffin fan on 240V | Electronics | |||
running fan/light off 1mm | UK diy | |||
outside air conditioning cooling fan keeps running | Home Repair | |||
ok, my problem seems to be with the furnace fan constantly running | Home Repair |