Default Too Many BENDS in Plumbing?

I'm going to install a sediment filter after my water softener which
runs to my well. An ideal place would be just above the softener tank,
but the particular location would require me to add at least two more
(3/4" copper) elbows. Given the effects adding bends has on air-
ducting, I'd expect it would have a negative effect on water flow as
well. Or am I exaggerating the importance of this?

Thanks!

Mark

  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 385
Default Too Many BENDS in Plumbing?


"gmark" wrote in message
oups.com...
I'm going to install a sediment filter after my water softener which
runs to my well. An ideal place would be just above the softener tank,
but the particular location would require me to add at least two more
(3/4" copper) elbows. Given the effects adding bends has on air-
ducting, I'd expect it would have a negative effect on water flow as
well. Or am I exaggerating the importance of this?

Thanks!

Mark


I don't think it would do that much. Could you use a flex hose and tie it
inline? Might make the filter easier to service, too.

Steve


  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 746
Default Too Many BENDS in Plumbing?

gmark wrote:

I'm going to install a sediment filter after my water softener which
runs to my well. An ideal place would be just above the softener tank,
but the particular location would require me to add at least two more
(3/4" copper) elbows. Given the effects adding bends has on air-
ducting, I'd expect it would have a negative effect on water flow as
well. Or am I exaggerating the importance of this?

Thanks!

Mark


Not of great importance. It's akin to
adding a few more feet of straight run.
The resistance of the filter itself will
outweigh the effect of 2 EL's.

Jim
  #4   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 929
Default Too Many BENDS in Plumbing?

On Apr 9, 4:30 pm, "gmark" wrote:
I'm going to install a sediment filter after my water softener which
runs to my well. An ideal place would be just above the softener tank,
but the particular location would require me to add at least two more
(3/4" copper) elbows. Given the effects adding bends has on air-
ducting, I'd expect it would have a negative effect on water flow as
well. Or am I exaggerating the importance of this?

Thanks!

Mark


Or am I exaggerating the importance of this?


Perhaps slightly........ but an excessive number of fttings will
increase the pressure drop

when sizing / designing plumbing systems......fittings; elbows,
valves, etc "add" an equivalent length of straight ......that way it's
easy it figure the pressure drop

3/4" 90's "add" about 2 feet

http://www.copper.org/applications/p...cth_table7.htm


cheers
Bob

  #5   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 5,823
Default Too Many BENDS in Plumbing?


"gmark" wrote in message
oups.com...
I'm going to install a sediment filter after my water softener which
runs to my well. An ideal place would be just above the softener tank,
but the particular location would require me to add at least two more
(3/4" copper) elbows. Given the effects adding bends has on air-
ducting, I'd expect it would have a negative effect on water flow as
well. Or am I exaggerating the importance of this?


Two elbows won't be noticed. OTOH, the filter should be before the softener
to prevent sediment from gunking up the softener valves.

Also, I don't understand why a softener would run to the well. The well
line should run to the softener. Either your plumbing or your sentence
structure is incorrect.




  #6   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 695
Default Too Many BENDS in Plumbing?

Elbow away, they'll make no difference.

--
Steve Barker




"gmark" wrote in message
oups.com...
I'm going to install a sediment filter after my water softener which
runs to my well. An ideal place would be just above the softener tank,
but the particular location would require me to add at least two more
(3/4" copper) elbows. Given the effects adding bends has on air-
ducting, I'd expect it would have a negative effect on water flow as
well. Or am I exaggerating the importance of this?

Thanks!

Mark



  #7   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,300
Default Too Many BENDS in Plumbing?

gmark wrote:
I'm going to install a sediment filter after my water softener which
runs to my well. An ideal place would be just above the softener tank,
but the particular location would require me to add at least two more
(3/4" copper) elbows. Given the effects adding bends has on air-
ducting, I'd expect it would have a negative effect on water flow as
well. Or am I exaggerating the importance of this?

Thanks!

Mark


I think as others have said, you probably won't notice too much
difference in water flow.

But, if you're anal about minimizing the pressure drop and don't mind
paying a couple of bucks more for the parts, then spring for larger
radius "long turn" elbows like these:

http://www.bramec.com/categories/detail.asp?cat=2171

Many fitting manufacturers make them.

Jeff

--
Jeffry Wisnia
(W1BSV + Brass Rat '57 EE)
The speed of light is 1.8*10^12 furlongs per fortnight.

  #8   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 14
Default Too Many BENDS in Plumbing?

On Apr 10, 3:29 pm, Jeff Wisnia wrote:
gmarkwrote:
I'm going to install a sediment filter after mywatersoftener which
runs to my well. An ideal place would be just above the softener tank,
but the particular location would require me to add at least two more
(3/4" copper) elbows. Given the effects adding bends has on air-
ducting, I'd expect it would have a negative effect onwaterflow as
well. Or am I exaggerating the importance of this?


Thanks!


Mark


I think as others have said, you probably won't notice too much
difference inwaterflow.

But, if you're anal about minimizing the pressure drop and don't mind
paying a couple of bucks more for the parts, then spring for larger
radius "long turn" elbows like these:

http://www.bramec.com/categories/detail.asp?cat=2171

Many fitting manufacturers make them.

Jeff



Excellent -- thanks!

I'll answer some questions --
1) Yes, it's my sentence structure. I'm talking about "runs" as in
"the pipe runs" -- not the water itself. The well goes to the
softener.
2) I'm putting the filter after the softener because the filter is a
fine porosity with a charcoal element, which I think wouldn't last
nearly as long if the softener is not removing some of the minerals,
etc.. And the last softener we rented from Eco never had any problems
with our water for at least 15 years. Plus, the location I have in
mind is right at eye level under the light, so checking the filter
should be a breeze.
3) I checked several manufacturers (which is likely also overkill,
since I didn't see any difference). I saw that the "Omni" looks pretty
much like all the others -- GE, Culligan, etc. -- but was a couple
bucks cheaper, and transparent (a plus, I think). The replacement
filters, however, had the same specs, but the others were between 10
and 35 bucks for replacements, while the Omni at Menards was 3-5
bucks, same specs. If this is temporary, or if there really is a
difference, at least I've got the plumbing done.
4) I stayed away from flex tubing for the same reason I've done so in
furnace ducting -- kinetc and viscous friction through the corrugated,
bendable hose. This may have been my exaggeration of the importance as
well. I guess from what everyone's said, viscous friction is of less
significance in water compared to air due to the energy consumed in
moving the mass of water. I found the equivalence of an elbow to the
effects of a length of straight pipe to be very informative, too!

Thanks again!

Mark

  #9   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 5,823
Default Too Many BENDS in Plumbing?


"gmark" wrote in message

3) I checked several manufacturers (which is likely also overkill,
since I didn't see any difference). I saw that the "Omni" looks pretty
much like all the others -- GE, Culligan, etc. -- but was a couple
bucks cheaper, and transparent (a plus, I think). The replacement
filters, however, had the same specs, but the others were between 10
and 35 bucks for replacements, while the Omni at Menards was 3-5
bucks, same specs. If this is temporary, or if there really is a
difference, at least I've got the plumbing done.


Can't say much about hte housing and I'm not familir with ti. I'd only have
a transparent one myself. As for element brands, I buy what I get at a good
price. For sediment, the brand does not seem to matter at all and I've been
using filters for about 20 years now. The kitchen filter though, I've had
better luck with Instapure charcoal filters for long life over other brands.




  #10   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 140
Default Too Many BENDS in Plumbing?

Abe wrote:
I'm going to install a sediment filter after my water softener which
runs to my well. An ideal place would be just above the softener tank,
but the particular location would require me to add at least two more
(3/4" copper) elbows. Given the effects adding bends has on air-
ducting, I'd expect it would have a negative effect on water flow as
well. Or am I exaggerating the importance of this?


Wouldn't it make more sense to install the filter before the water
softener?


Absolutely. You don't want sediment contaminating the resin bed.

Rob


  #11   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 17
Default Too Many BENDS in Plumbing?


"gmark" wrote in message
ups.com...
On Apr 10, 3:29 pm, Jeff Wisnia wrote:
gmarkwrote:
I'm going to install a sediment filter after mywatersoftener which
runs to my well. An ideal place would be just above the softener tank,
but the particular location would require me to add at least two more
(3/4" copper) elbows. Given the effects adding bends has on air-
ducting, I'd expect it would have a negative effect onwaterflow as
well. Or am I exaggerating the importance of this?


yes you are.


  #12   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1
Default Too Many BENDS in Plumbing?

On 10 apr, 00:30, "gmark" wrote:
I'm going to install a sediment filter after my water softener which
runs to my well. An ideal place would be just above the softener tank,
but the particular location would require me to add at least two more
(3/4" copper) elbows. Given the effects adding bends has on air-
ducting, I'd expect it would have a negative effect on water flow as
well. Or am I exaggerating the importance of this?

Thanks!

Mark



Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Plumbing Code - Can I tie my bathroom exaust fan into the main plumbing vent to the outside. johnnymo Home Repair 29 December 9th 18 02:08 AM
dryer vent length, multiple bends Joseph O'Brien Home Repair 10 January 17th 06 07:04 PM
Bending handbook was:tight radius bends in conduit Rick Metalworking 14 August 11th 05 01:43 AM
tight radius bends in conduit Don Foreman Metalworking 20 August 8th 05 03:15 PM
Tips on repetative multiple bends on rod... Jeff Metalworking 4 May 23rd 05 03:03 PM


All times are GMT +1. The time now is 08:12 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"