Electronics Repair (sci.electronics.repair) Discussion of repairing electronic equipment. Topics include requests for assistance, where to obtain servicing information and parts, techniques for diagnosis and repair, and annecdotes about success, failures and problems.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 189
Default Smart plug energy monitoring chip

Does anyone recognise this energy monitoring chip? The marking I see is
"1852AVH":

https://www.dropbox.com/s/pzf0km6m85c0a1s/SmartPlugEnergyChip2.jpg
https://www.dropbox.com/s/46sl5cxqapm9v4r/SmartPlugEnergyChip3.jpg

It's in an Aldi (Medion brand) WiFi smart plug.

Clifford Heath.
  #2   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 4,045
Default Smart plug energy monitoring chip

On Tue, 24 Sep 2019 10:28:09 +1000, Clifford Heath
wrote:

Does anyone recognise this energy monitoring chip? The marking I see is
"1852AVH":
https://www.dropbox.com/s/pzf0km6m85c0a1s/SmartPlugEnergyChip2.jpg
https://www.dropbox.com/s/46sl5cxqapm9v4r/SmartPlugEnergyChip3.jpg


The "8" is really a "B". Try 1B52AVH instead.
Some image enhancement:
http://www.learnbydestroying.com/jeffl/crud/1B52AVH.jpg
Unfortunatly, I couldn't find anything with that part number using
Google search.

It's in an Aldi (Medion brand) WiFi smart plug.


Model number? Photo? Any patent numbers in the docs?

I couldn't find the logo:
https://www.elnec.com/en/support/ic-logos/?method=logo
http://www.siliconinvestigations.com/Logos/logos.htm
http://www.ecadata.de/herst/myshowlogo.php?F_SPRACHE=2

I don't know if this is the same product, but it's easy enough to try:
"Kankun Runs on OpenWrt firmware"
http://www.htlinux.com/kankun-runs-on-openwrt-firmware/


--
Jeff Liebermann
150 Felker St #D
http://www.LearnByDestroying.com
Santa Cruz CA 95060 http://802.11junk.com
Skype: JeffLiebermann AE6KS 831-336-2558
  #3   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 189
Default Smart plug energy monitoring chip

On 24/9/19 11:21 am, Jeff Liebermann wrote:
On Tue, 24 Sep 2019 10:28:09 +1000, Clifford Heath
wrote:
Does anyone recognise this energy monitoring chip? The marking I see is
"1852AVH":
https://www.dropbox.com/s/pzf0km6m85c0a1s/SmartPlugEnergyChip2.jpg
https://www.dropbox.com/s/46sl5cxqapm9v4r/SmartPlugEnergyChip3.jpg

The "8" is really a "B". Try 1B52AVH instead.


I tried that too, but (see 2nd image) I'm pretty sure it's an "8".

Anyhow more searching and it looks like someone has figured it out and
ported Tasmota to it, and they call it a BL0937 (first line of text, not
second). Still can't find a data sheet but there's a driver here. Same
code for HJL-01 which looks a lot like an HLW8012 supposedly:
https://github.com/arendst/Sonoff-Tasmota/blob/development/sonoff/xnrg_01_hlw8012.ino

It's in an Aldi (Medion brand) WiFi smart plug.

Model number? Photo? Any patent numbers in the docs?


"Medion LIFE+ Smart Plug", S85225, model number MD 93225.
It says it's compatible with Alexa and Google Home.
Similar is available he
https://www.ebay.com.au/itm/Smart-Plug-S85225-Compatible-with-Amazon-Alexa-Medion-Wifi-Life-Google-Home-/401785952652

I couldn't find the logo:


Me either .

https://www.elnec.com/en/support/ic-logos/?method=logo
http://www.siliconinvestigations.com/Logos/logos.htm
http://www.ecadata.de/herst/myshowlogo.php?F_SPRACHE=2


Thanks,

Clifford Heath.
  #4   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 4,045
Default Smart plug energy monitoring chip

On Tue, 24 Sep 2019 12:43:11 +1000, Clifford Heath
wrote:

On 24/9/19 11:21 am, Jeff Liebermann wrote:
On Tue, 24 Sep 2019 10:28:09 +1000, Clifford Heath
wrote:
Does anyone recognise this energy monitoring chip? The marking I see is
"1852AVH":
https://www.dropbox.com/s/pzf0km6m85c0a1s/SmartPlugEnergyChip2.jpg
https://www.dropbox.com/s/46sl5cxqapm9v4r/SmartPlugEnergyChip3.jpg

The "8" is really a "B". Try 1B52AVH instead.


I tried that too, but (see 2nd image) I'm pretty sure it's an "8".


I beg to differ. Take another look at my image at:
http://www.learnbydestroying.com/jeffl/crud/1B52AVH.jpg
Notice that the "B" in "BL" on the first line is exactly the same as
the "B" on the 2nd line.

Anyhow more searching and it looks like someone has figured it out and
ported Tasmota to it, and they call it a BL0937 (first line of text, not
second).


Oops. I didn't think of that.

Still can't find a data sheet but there's a driver here. Same
code for HJL-01 which looks a lot like an HLW8012 supposedly:
https://github.com/arendst/Sonoff-Tasmota/blob/development/sonoff/xnrg_01_hlw8012.ino


I don't think so. Looking at the circuitry around the chip, it looks
like some kind of analog device, not a energy monitor, which usually
has an SPI bus and talks digital. Googling for BL0937, I find an
analog current regulator:
https://lcsc.com/product-detail/PMIC-Current-Regulation_BL0937_C94616.html
If you zoom into the photo on the above page, it looks exactly like
your two photos.

Mo
https://www.google.com/search?q=BL0937&tbm=isch

It's in an Aldi (Medion brand) WiFi smart plug.

Model number? Photo? Any patent numbers in the docs?


"Medion LIFE+ Smart Plug", S85225, model number MD 93225.
It says it's compatible with Alexa and Google Home.
Similar is available he
https://www.ebay.com.au/itm/Smart-Plug-S85225-Compatible-with-Amazon-Alexa-Medion-Wifi-Life-Google-Home-/401785952652


I couldn't find the logo:


Me either .


Foundit. It's Shanghai Belling Co., Ltd., formerly known as Shanghai
Belling Microelectronics Manufacturing Co., Ltd:
https://lcsc.com/brand-detail/158.html
Notice the logo at:
https://assets.lcsc.com/images/manufacturer/158.jpg


--
Jeff Liebermann
150 Felker St #D
http://www.LearnByDestroying.com
Santa Cruz CA 95060 http://802.11junk.com
Skype: JeffLiebermann AE6KS 831-336-2558
  #5   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 189
Default Smart plug energy monitoring chip

On 24/9/19 2:54 pm, Jeff Liebermann wrote:
On Tue, 24 Sep 2019 12:43:11 +1000, Clifford Heath
wrote:

On 24/9/19 11:21 am, Jeff Liebermann wrote:
On Tue, 24 Sep 2019 10:28:09 +1000, Clifford Heath
wrote:
Does anyone recognise this energy monitoring chip? The marking I see is
"1852AVH":
https://www.dropbox.com/s/pzf0km6m85c0a1s/SmartPlugEnergyChip2.jpg
https://www.dropbox.com/s/46sl5cxqapm9v4r/SmartPlugEnergyChip3.jpg

Anyhow more searching and it looks like someone has figured it out and
ported Tasmota to it, and they call it a BL0937 (first line of text, not
second).


Oops. I didn't think of that.


Well, for some reason the data sheet doesn't come up in Google, but here
it is:
https://github.com/xoseperez/espurna/files/1861834/BL0937_Datasheet_V1.01.pdf.zip
or from the manufactorer's site:
http://www.belling.com.cn/en/product_info.html?id=138

A differential input (across a 0.001R resistor), a voltage input, both
connected to ADCs and thence to voltage-to-frequency converters. There
are two frequency outputs, and a selector pin for voltage or current on
one of them. The other frequency indicates power; presumably closer to
instantaneous power whereas the I and V can't be read simultaneously.

That matches the pinout of the HLW8012 also, but the select polarity is
reversed or some such nonsense; the driver writer has worked it out
anyhow, see the thread at https://github.com/xoseperez/espurna/issues/737.

I don't think so. Looking at the circuitry around the chip, it looks
like some kind of analog device, not a energy monitor, which usually
has an SPI bus and talks digital. Googling for BL0937, I find an
analog current regulator:
https://lcsc.com/product-detail/PMIC-Current-Regulation_BL0937_C94616.html
If you zoom into the photo on the above page, it looks exactly like
your two photos.


Nevertheless that's not it.

I couldn't find the logo:

Me either .

Foundit. It's Shanghai Belling Co., Ltd., formerly known as Shanghai
Belling Microelectronics Manufacturing Co., Ltd:
https://lcsc.com/brand-detail/158.html
Notice the logo at:
https://assets.lcsc.com/images/manufacturer/158.jpg


Thank you.

Clifford Heath.
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Smart meter replacement 'Smart energy display'. Roland Perry UK diy 6 July 22nd 18 07:35 AM
Smart meters not smart enough Brian Gaff UK diy 16 May 25th 17 08:22 AM
What is smart about a smart DVD player? micky Electronics Repair 9 December 16th 13 06:07 PM
Smart Tool Level or Smart Level Cynthia McGraw Metalworking 6 September 1st 09 06:06 AM
Advice on how locating ( Chip FA4111 & chip M52722P) in the UK ? (for a vgood 21" monitor) Chris Electronics 1 January 29th 04 03:46 AM


All times are GMT +1. The time now is 04:32 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us