I have a potterton suprima 60 boiler which over the last 2 weeks has
gradually got worse with the locking out problem. I've had the PCB out
, fan, air pressure switch ( which i have tested for continuity)
cleaned all contacts. Everytime I have a look at the innards of the
boiler( 3-4 times so far) it works perfectly for 24-36 hours before
starting to lock out more and more frequently until it goes straight
to lock out after a few attempts at lighting. At the moment the boiler
ignites and burns for a few seconds but the the green light continues
to flash at high frequency instead of going on continuously as it
should , the burner then extinguishes. According to the fault finder
flow chart the problem is either with the PCB or the gas valve,
depending on whether there is 300vDC between red and black wires to
the gas valve. I need to get a volt meter to check this. The PCB is a
reconditioned unit from CETltd which I purchased last Winter after
similar lock out problems although last years problems were sorted out
with a new air pressure switch. When I took the PCB out I noticed some
scorch marks around some of the resisters on the middle of the board.
My gut instinct is to replace the PCB again as this seems to be the
common fault with these boilers. It seems like the control is not
getting a boiler has lit signal and so switches off the gas valve. Any
suggestions gratefully received.

Jim
 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Potterton Suprima 80 "Lockout" David Longley UK diy 25 April 26th 05 11:49 PM
Potterton Suprima 30 lockout Mike W UK diy 3 November 17th 04 08:21 PM
Grudfos Alpha & Potterton Suprima 'bug'? Rory UK diy 28 October 28th 04 12:44 AM
Potterton Suprima 100 update Richard Savage UK diy 2 April 19th 04 08:35 PM
CH boiler - making droning noise - Potterton Suprima 60 Eric the Red UK diy 2 September 29th 03 03:01 PM


All times are GMT +1. The time now is 01:38 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"