I have a single switch down which controls a light near the front door it
also can be switched on or of by a double switch upstairs at the moment if you have the upstairs switch in one position you cant switch the light on or off. I also have another single switch down stairs which controls the light at the top of the stairs. that is also controlled by the double switch upstairs with that one the light only comes on by using the down stairs switch. this all came about when I tried to replace the switches. before I started I wrote down the way the switches were wired but I seem to have gone wrong somewhere . is there some where I can get a wiring diagram or can someone explain where I have gone wrong |
#2
![]() |
|||
|
|||
![]()
robert horsey wrote:
is there some where I can get a wiring diagram or can someone explain where I have gone wrong Try this:- http://www.diyfaq.org.uk/electrical/...l.html#two-way -- Cheers, John. /================================================== ===============\ | Internode Ltd - http://www.internode.co.uk | |-----------------------------------------------------------------| | John Rumm - john(at)internode(dot)co(dot)uk | \================================================= ================/ |
#3
![]() |
|||
|
|||
![]()
In article ,
robert horsey wrote: I have a single switch down which controls a light near the front door it also can be switched on or of by a double switch upstairs at the moment if you have the upstairs switch in one position you cant switch the light on or off. I also have another single switch down stairs which controls the light at the top of the stairs. that is also controlled by the double switch upstairs with that one the light only comes on by using the down stairs switch. this all came about when I tried to replace the switches. before I started I wrote down the way the switches were wired but I seem to have gone wrong somewhere . is there some where I can get a wiring diagram or can someone explain where I have gone wrong L1 L1 0===========0 0===========0============= Line | \ / | C 0================================O C \ / \ / 0===========0 0===========0============= Switch return L2 Optional L2 Intermediate -- *Starfishes have no brains * Dave Plowman London SW To e-mail, change noise into sound. |
#4
![]() |
|||
|
|||
![]() "robert horsey" wrote in message ... I have a single switch down which controls a light near the front door it also can be switched on or of by a double switch upstairs at the moment if you have the upstairs switch in one position you cant switch the light on or off. I also have another single switch down stairs which controls the light at the top of the stairs. that is also controlled by the double switch upstairs with that one the light only comes on by using the down stairs switch. this all came about when I tried to replace the switches. before I started I wrote down the way the switches were wired but I seem to have gone wrong somewhere . is there some where I can get a wiring diagram or can someone explain where I have gone wrong When you said you noted down which wires went where did you note down top right top middle top left etc? or com L1 L2 If the first then you could find if you look at the back of your old and new double (2 gang) switches that they may be arranged differently eg looking at the top row of terminals one might be com L1 L2 the other L2 L1 com Different makes of switches have the backs arranged differently some are like /\ \/ and others \/ /\ the base of the V being the com If so then the answer after looking at the faq would be to work out how the circuits were wired originally com L1 L2 etc and then wire your new one up with the wires going to the correct terminals Steve |
#5
![]() |
|||
|
|||
![]()
On 2 Oct 2004 "robert horsey" wrote:
I have a single switch down which controls a light near the front door it also can be switched on or of by a double switch upstairs at the moment if you have the upstairs switch in one position you cant switch the light on or off. What do you mean by this? Is the light permanently off or permanently on, or as I interpret your description, does it stay in whatever state it was set to by the downstairs switch when you put the upstairs switch in this position? I find this somewhat difficult to believe. It's more likely that you have connected one of the wires from the light to the common terminal instead of one of the other two. That way if either switch is in the on position you won't be able to turn the light off using the other switch. I also have another single switch down stairs which controls the light at the top of the stairs. that is also controlled by the double switch upstairs with that one the light only comes on by using the down stairs switch. I'm beginning to think that you may have cross-wired the two sections of the double switch upstairs, or that one of the wires is not connected or one switch is duff. I'd be inclined to take the switches off, suss out what does what if the terminals aren't clearly marked and start again. this all came about when I tried to replace the switches. before I started I wrote down the way the switches were wired but I seem to have gone wrong somewhere . Is there some where I can get a wiring diagram or can someone explain where I have gone wrong It should be straightforward. Both switches are connected by a triple core (+ earth) cable. Make sure you connect C to C, L1 to L1 and L2 to L2. C is the common terminal which is connected by the switch to either L1 or L2. If the switch isn't marked then test it with a circuit tester or multimeter or lamp and battery (when it's not connected to the mains of course). Never mind what physical positions the wires were in before because switch designs vary. At one of the switches - probably the downstairs switch for the downstairs light and the upstairs switch for the upstairs light - there will also be a two core (+ earth) cable. This should be connected to L1 and L2, not C. I'm not sure what the regs say but on the triple core cable I use red for the live side, connected to red on the twin, blue for the load side, connected to black on the twin, and yellow between the commons. All earth wires, if provided, should be sleeved and terminated on the wall boxes. If there's an earth terminal on the switch (if it has a metal face plate) this should also be connected. The way it operates is that if the common wire is connected to live at one switch and load (the lamp) at the other switch then the lamp is on; if common is connected to the same side on both switches the lamp is off. -- Richard Porter Mail to username ricp at domain minijem.plus.com "You can't have Windows without pains." |