UK diy (uk.d-i-y) For the discussion of all topics related to diy (do-it-yourself) in the UK. All levels of experience and proficency are welcome to join in to ask questions or offer solutions.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
No-one
 
Posts: n/a
Default Inset gas fires - query as to pipe run

I have an old style gas fire siiting in front of a fire surround on
the hearth. The gas supply is via a chrome pipe attached to the pipe
supply which exits the floor some 2 feet to the right of the fire.

I am considering getting opening up the fireplace and getting an inset
gas fire. Before I decide on this, what is the likely way the pipe
would be made to run from the supply to the fire, given that it would
be in the fireplace proper? Would a fitter bury the pipe behind the
skirting (possibly into the plaster) or run it in much the same way as
it is now?

TIA
  #2   Report Post  
Roger Mills
 
Posts: n/a
Default Inset gas fires - query as to pipe run


"No-one" wrote in message
...
I have an old style gas fire siiting in front of a fire surround on
the hearth. The gas supply is via a chrome pipe attached to the pipe
supply which exits the floor some 2 feet to the right of the fire.

I am considering getting opening up the fireplace and getting an inset
gas fire. Before I decide on this, what is the likely way the pipe
would be made to run from the supply to the fire, given that it would
be in the fireplace proper? Would a fitter bury the pipe behind the
skirting (possibly into the plaster) or run it in much the same way as
it is now?

TIA


Is it a solid or wooden floor? If the latter, it shouldn't be too difficult
to re-route the pipe under the floor boards and to make it emerge inside the
builder's opening where your inset fire will go - thus making it invisible.

If it's buried in a solid floor, it's not quite so easy - but may still be
possible.

Roger


  #3   Report Post  
David Hearn
 
Posts: n/a
Default Inset gas fires - query as to pipe run


"Roger Mills" wrote in message
...

"No-one" wrote in message
...
I have an old style gas fire siiting in front of a fire surround on
the hearth. The gas supply is via a chrome pipe attached to the pipe
supply which exits the floor some 2 feet to the right of the fire.

I am considering getting opening up the fireplace and getting an inset
gas fire. Before I decide on this, what is the likely way the pipe
would be made to run from the supply to the fire, given that it would
be in the fireplace proper? Would a fitter bury the pipe behind the
skirting (possibly into the plaster) or run it in much the same way as
it is now?

TIA


Is it a solid or wooden floor? If the latter, it shouldn't be too

difficult
to re-route the pipe under the floor boards and to make it emerge inside

the
builder's opening where your inset fire will go - thus making it

invisible.

If it's buried in a solid floor, it's not quite so easy - but may still be
possible.


Ours is like your first suggestion, but the previous people built a large
brick fireplace ontop of the boards it seems. Pipe exits just in front of
the fire (through mortar/brickwork) - so if we needed to replace it, it
might be a problem. The pipe has a slight kink in it (badly bent? knocked
with the grating?) and it's not leaking or anything - but I suspect that
should anyone inspect/service it, they'd notice it and it might be a
problem.

So - running under floorboards is great - just done set it in brickwork
afterwards!!!

D


  #4   Report Post  
Chris J Dixon
 
Posts: n/a
Default Inset gas fires - query as to pipe run

No-one wrote:

I have an old style gas fire siiting in front of a fire surround on
the hearth. The gas supply is via a chrome pipe attached to the pipe
supply which exits the floor some 2 feet to the right of the fire.

I am considering getting opening up the fireplace and getting an inset
gas fire. Before I decide on this, what is the likely way the pipe
would be made to run from the supply to the fire, given that it would
be in the fireplace proper? Would a fitter bury the pipe behind the
skirting (possibly into the plaster) or run it in much the same way as
it is now?


When I accidentally drilled a copper gas pipe which had been
buried in the plaster around the chimney breast, the gas board
turned up to sort it out. When we chopped out to find the
connection to the original steel pipe it was declared to be a
very dodgy installation, and they insisted that the replacement
pipe was surface run.

Chris
--
Chris J Dixon Nottingham UK


Have dancing shoes, will ceilidh.
  #5   Report Post  
 
Posts: n/a
Default Inset gas fires - query as to pipe run

No-one wrote:

I have an old style gas fire siiting in front of a fire surround on
the hearth. The gas supply is via a chrome pipe attached to the pipe
supply which exits the floor some 2 feet to the right of the fire.

I am considering getting opening up the fireplace and getting an inset
gas fire. Before I decide on this, what is the likely way the pipe
would be made to run from the supply to the fire, given that it would
be in the fireplace proper? Would a fitter bury the pipe behind the
skirting (possibly into the plaster) or run it in much the same way as
it is now?

TIA


Others have answered your question but one point to note is if the fitter
buries the copper pipe in either the plaster or cement make sure he has
lagged the pipe.

I have taken out copper pipes from cement after 10 or so years and they are
green a corroding badly, a nuisance for water but a little scary for Gas

:-)

Andy


  #6   Report Post  
Lobster
 
Posts: n/a
Default Inset gas fires - query as to pipe run

No-one wrote in message . ..
I have an old style gas fire siiting in front of a fire surround on
the hearth. The gas supply is via a chrome pipe attached to the pipe
supply which exits the floor some 2 feet to the right of the fire.

I am considering getting opening up the fireplace and getting an inset
gas fire. Before I decide on this, what is the likely way the pipe
would be made to run from the supply to the fire, given that it would
be in the fireplace proper? Would a fitter bury the pipe behind the
skirting (possibly into the plaster) or run it in much the same way as
it is now?


It certainly can be buried, but the pipe should contact plaster/mortar
directly as it's likely to corrode. It can be wrapped in protective
tape, but your best bet is to have the actual gas pipe pass through a
plastic conduit if that's possible, so it can be easily accesssed and
serviced in the future. Me, I don't like burying pipes (gas or water)
in walls.

If you'll be paying a CORGI hourly rate to fit your fire, you might
want to do the donkey work of creating the conduit, or whatever,
yourself.

David
  #7   Report Post  
John Stumbles
 
Posts: n/a
Default Inset gas fires - query as to pipe run

"Lobster" wrote in message
om...
No-one wrote in message

. ..
I have an old style gas fire siiting in front of a fire surround on
the hearth. The gas supply is via a chrome pipe attached to the pipe
supply which exits the floor some 2 feet to the right of the fire.

I am considering getting opening up the fireplace and getting an inset
gas fire. Before I decide on this, what is the likely way the pipe
would be made to run from the supply to the fire, given that it would
be in the fireplace proper? Would a fitter bury the pipe behind the
skirting (possibly into the plaster) or run it in much the same way as
it is now?


It certainly can be buried, but the pipe should contact plaster/mortar
directly as it's likely to corrode. It can be wrapped in protective
tape, but your best bet is to have the actual gas pipe pass through a
plastic conduit if that's possible, so it can be easily accesssed and
serviced in the future. Me, I don't like burying pipes (gas or water)
in walls.


If it runs through a wall it _must_ be run in a sleeve

If you'll be paying a CORGI hourly rate to fit your fire, you might
want to do the donkey work of creating the conduit, or whatever,
yourself.


Before I got my dog licence I did this for a customer I was fitting a fire
surround and hearth for. I drilled a hole through from near the gas elbow
(connector) back into the builder's opening and ran some 15mm copper pipe
through as a conduit for the (8mm or 10mm) pipe for the fire itself (which
was later fitted by a qualified dog).



--
John Stumbles
-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-|-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
-+



Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Does anybody make 10cm pipe that is composed of 'cake slice' sections? Jo UK diy 1 November 3rd 03 01:43 AM
WC soil Pipe hays UK diy 17 October 30th 03 05:21 PM
Sensor pipe on Baxi Bermuda inset 2 Jonathan Curtis UK diy 1 October 17th 03 09:21 PM
Converting soil pipe access panel to allow 40mm pipe Scott UK diy 1 August 12th 03 10:14 PM
LPG cooker - gas supply query drlurch UK diy 2 July 14th 03 11:58 AM


All times are GMT +1. The time now is 09:01 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"