Colour flagging of wires
On this subject I'm surprised wholesalers don't sell Hellerman sleeving in
the right colours and sizes for identification - much better than a bit of PVC which can fall off. -- *The most wasted day of all is one in which we have not laughed.* Dave Plowman London SW To e-mail, change noise into sound. |
#2
Posted to uk.d-i-y
|
|||
|
|||
Colour flagging of wires
In article ,
"Dave Plowman (News)" writes: On this subject I'm surprised wholesalers don't sell Hellerman sleeving in the right colours and sizes for identification - much better than a bit of PVC which can fall off. It needs a tool to get it on (and ideally some sleave oil). Too slow/fiddly/expensive for something the trade seems to consider as a waste of time. -- Andrew Gabriel [email address is not usable -- followup in the newsgroup] |
#3
Posted to uk.d-i-y
|
|||
|
|||
Colour flagging of wires
Andrew Gabriel formulated the question :
In article , "Dave Plowman (News)" writes: On this subject I'm surprised wholesalers don't sell Hellerman sleeving in the right colours and sizes for identification - much better than a bit of PVC which can fall off. It needs a tool to get it on (and ideally some sleave oil). Too slow/fiddly/expensive for something the trade seems to consider as a waste of time. I'm surprised no one uses those white slide on tags as used in panels, with letters/numbers printed on them in black. Two tags marked S and W, to make up SW for switch wire -would leave no one in any doubt. -- Regards, Harry (M1BYT) (L) http://www.ukradioamateur.co.uk |
#4
Posted to uk.d-i-y
|
|||
|
|||
Colour flagging of wires
In article ,
Harry Bloomfield writes: I'm surprised no one uses those white slide on tags as used in panels, with letters/numbers printed on them in black. Two tags marked S and W, to make up SW for switch wire -would leave no one in any doubt. When I was redoing the lighting in a house for home-automation (all lighting points and switch cables run to a central wiring point, a bit like cat5 cabling), I found biro writes very nicely on white PVC sheath, and labelled all the wires that way. -- Andrew Gabriel [email address is not usable -- followup in the newsgroup] |
#5
Posted to uk.d-i-y
|
|||
|
|||
Colour flagging of wires
"Andrew Gabriel" wrote in message ... In article , Harry Bloomfield writes: I'm surprised no one uses those white slide on tags as used in panels, with letters/numbers printed on them in black. Two tags marked S and W, to make up SW for switch wire -would leave no one in any doubt. When I was redoing the lighting in a house for home-automation (all lighting points and switch cables run to a central wiring point, a bit like cat5 cabling), I found biro writes very nicely on white PVC sheath, and labelled all the wires that way. Andrew Gabriel And a 10p Biro does thousands of cables. :-) |
#6
Posted to uk.d-i-y
|
|||
|
|||
Colour flagging of wires
We were somewhere around Barstow, on the edge of the desert, when the
drugs began to take hold. I remember (Andrew Gabriel) saying something like: When I was redoing the lighting in a house for home-automation (all lighting points and switch cables run to a central wiring point, a bit like cat5 cabling), I found biro writes very nicely on white PVC sheath, and labelled all the wires that way. I generally use a tab of white insulating tape and a CD marker, if it's a jb or fitting I'll be coming back to, sometimes weeks later. |
#7
Posted to uk.d-i-y
|
|||
|
|||
Colour flagging of wires
We were somewhere around Barstow, on the edge of the desert, when the
drugs began to take hold. I remember Harry Bloomfield saying something like: I'm surprised no one uses those white slide on tags as used in panels, with letters/numbers printed on them in black. Two tags marked S and W, to make up SW for switch wire -would leave no one in any doubt. For a wire which will, in all probability, never be looked at again? Get real. Such things are useful in control panels for plant, where the opening of the lid more than once and someone rooting around fixing a fault is very likely during the lifetime of the equipment. |
#8
Posted to uk.d-i-y
|
|||
|
|||
Colour flagging of wires
In article ,
Andrew Gabriel wrote: In article , "Dave Plowman (News)" writes: On this subject I'm surprised wholesalers don't sell Hellerman sleeving in the right colours and sizes for identification - much better than a bit of PVC which can fall off. It needs a tool to get it on (and ideally some sleave oil). Too slow/fiddly/expensive for something the trade seems to consider as a waste of time. The right size will slip on with a bit of spit ;-) - secure enough not to fall off afterwards. -- *A journey of a thousand sites begins with a single click * Dave Plowman London SW To e-mail, change noise into sound. |
#9
Posted to uk.d-i-y
|
|||
|
|||
Colour flagging of wires
Andrew Gabriel wrote:
In article , "Dave Plowman (News)" writes: On this subject I'm surprised wholesalers don't sell Hellerman sleeving in the right colours and sizes for identification - much better than a bit of PVC which can fall off. It needs a tool to get it on (and ideally some sleave oil). ....and probably doesn't meet BS 2848 (or its harmonised EN equivalent) as required by BS 7671. For a long time I used 2 mm i/d silicone rubber sleeving for this purpose - e.g. RS stock code 399-445. It complies with the standard, pushes nicely on to a 1.0 or 1.5 mm^2 conductor without special tools, stays put and looks neat. However I've been unable to source this material in brown and blue at anything like a sensible price. RS told me they had no plans to introduce those colours. Siegrist Orel were surprisingly unhelpful, wanting a large MOQ and a small order surcharge - GBP 70+ for 20 m of sleeving seemed just a little OTT! So I've taken to using heatshrink - but if anyone knows of a source of brown & blue silicone in small quantity, sensibly priced, I'd be most interested to hear. -- Andy |
#10
Posted to uk.d-i-y
|
|||
|
|||
Colour flagging of wires
I wrote:
[Re. Hellerman (Helsyn) sleeves] ...and probably doesn't meet BS 2848 (or its harmonised EN equivalent) as required by BS 7671. Sorry, ignore that bit - complete bollo. BS 2848 (now BS EN 60684 series) is only mandated for earth sleeving. Colour marking sleeving needs to meet BS 3858, which I've just looked up. It covers Hellerman type sleeving (polychloroprene), PVC and silicone types. For a long time I used 2 mm i/d silicone rubber sleeving for this purpose - e.g. RS stock code 399-445. It complies with the standard, pushes nicely on to a 1.0 or 1.5 mm^2 conductor without special tools, stays put and looks neat. However I've been unable to source this material in brown and blue at anything like a sensible price. RS told me they had no plans to introduce those colours. Siegrist Orel were surprisingly unhelpful, wanting a large MOQ and a small order surcharge - GBP 70+ for 20 m of sleeving seemed just a little OTT! So I've taken to using heatshrink - but if anyone knows of a source of brown & blue silicone in small quantity, sensibly priced, I'd be most interested to hear. Stet. -- Andy |
#11
Posted to uk.d-i-y
|
|||
|
|||
Colour flagging of wires
In article ,
Andy Wade wrote: [Re. Hellerman (Helsyn) sleeves] ...and probably doesn't meet BS 2848 (or its harmonised EN equivalent) as required by BS 7671. Sorry, ignore that bit - complete bollo. BS 2848 (now BS EN 60684 series) is only mandated for earth sleeving. Colour marking sleeving needs to meet BS 3858, which I've just looked up. It covers Hellerman type sleeving (polychloroprene), PVC and silicone types. Good - I'd not use it for earth sleeving anyway as that's ok. Just to inform others RS components etc stock Hellerman sleeving in suitable sizes and colours. Comes in packs of 100 about an inch long - so only suitable for identification in this application. -- *He who laughs last, thinks slowest. Dave Plowman London SW To e-mail, change noise into sound. |
#12
Posted to uk.d-i-y
|
|||
|
|||
Colour flagging of wires
In article ,
"Dave Plowman (News)" writes: In article , Andy Wade wrote: [Re. Hellerman (Helsyn) sleeves] ...and probably doesn't meet BS 2848 (or its harmonised EN equivalent) as required by BS 7671. Sorry, ignore that bit - complete bollo. BS 2848 (now BS EN 60684 series) is only mandated for earth sleeving. Colour marking sleeving needs to meet BS 3858, which I've just looked up. It covers Hellerman type sleeving (polychloroprene), PVC and silicone types. Good - I'd not use it for earth sleeving anyway as that's ok. Just to inform others RS components etc stock Hellerman sleeving in suitable sizes and colours. Comes in packs of 100 about an inch long - so only suitable for identification in this application. I bought mine from Farnell. CPC do some too, but annoyingly don't do the sleeve oil. I used to by it in tiny jars that lasted me 5 or more years. Last time, I could only find it in a large bottle, but at least I don't ever envisage having to buy any more in my lifetime. The sleeving all has use-by dates on it. Some of mine is now 15+ years past the dates, but it still seems OK. I make a point of storing it in the dark (I've noticed used pieces can deteriorate in sunlight). -- Andrew Gabriel [email address is not usable -- followup in the newsgroup] |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Colour flagging of wires | UK diy | |||
Adding new Circuits to Room Addition... 2 wires or 2 wires + Ground? | Home Repair | |||
Flagging Over Tarmac & Concrete | UK diy | |||
Blue colour instead of true colour in the monitor - how to fix it? | Electronics Repair | |||
Grounding Of Ground Wires In An Electrical Gang Box (how to handle the green ground wires) | Home Repair |