I have an aging ferroli Hawk II combi boiler and it has developed a
fault. It had a loss of pressure, which it often does, but now I have
refilled it no heating. The hot water is OK and the Pump is working
but all that happens for heating is that the boiler fires for approx
30 seconds then goes off for 10 minutes and then repeats. The
radiators are very slightly warm. Any help and ideas would be
appreciated
Thanks
  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 3,861
Default Hawk II combi no Heating

In message
,
" writes
I have an aging ferroli Hawk II combi boiler and it has developed a
fault. It had a loss of pressure, which it often does, but now I have
refilled it no heating. The hot water is OK and the Pump is working
but all that happens for heating is that the boiler fires for approx
30 seconds then goes off for 10 minutes and then repeats. The
radiators are very slightly warm. Any help and ideas would be
appreciated
Thanks


Air lock ?


--
geoff
  #4   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 16
Default Hawk II combi no Heating

On 17 Dec, 19:10, Ed Sirett wrote:
On Sun, 16 Dec 2007 11:44:21 -0800, wrote:
I have an aging ferroli Hawk II combi boiler and it has developed a
fault. It had a loss of pressure, which it often does, but now I have
refilled it no heating. The hot water is OK and the Pump is working but
all that happens for heating is that the boiler fires for approx 30
seconds then goes off for 10 minutes and then repeats. The radiators are
very slightly warm. Any help and ideas would be appreciated
Thanks


Pump problem (despite what you say).
Air locks.
detached impellor.
Temperature sensor.

Main flow/return isolator(s) closed.

See SealedCH FAQ about the pressure.

--
Ed Sirett - Property maintainer and registered gas fitter.
The FAQ for uk.diy is athttp://www.diyfaq.org.uk
Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html
Sealed CH FAQhttp://www.makewrite.demon.co.uk/SealedCH.html
Choosing a Boiler FAQhttp://www.makewrite.demon.co.uk/BoilerChoice.html


Took everything apart, then back together and it started going, don't
know why. The day before I undid the screw on the outside of the pump
and I can hear the pump stop, if i push in the hole with a screwdriver
it starts. Bleed the heat exchanger and found no air. If I listen at
the rads I can hear the pump pushing water so if it is the pump what
else can I do to confirm this. The mother board has diagnostic LEDs to
show whats going on and when working and power applied some should
light, however I have never seen any of them lite. Checked temp sensor
and 1K which corresponds to cold water in Rads, CH overheat
thermostate closed. I think it could well have needed venting, which I
did but never found any air. Just hope it keeps going
Thanks
  #5   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 16
Default Hawk II combi no Heating

On 18 Dec, 10:42, " wrote:
On 17 Dec, 19:10, Ed Sirett wrote:



On Sun, 16 Dec 2007 11:44:21 -0800, wrote:
I have an aging ferroli Hawk II combi boiler and it has developed a
fault. It had a loss of pressure, which it often does, but now I have
refilled it no heating. The hot water is OK and the Pump is working but
all that happens for heating is that the boiler fires for approx 30
seconds then goes off for 10 minutes and then repeats. The radiators are
very slightly warm. Any help and ideas would be appreciated
Thanks


Pump problem (despite what you say).
Air locks.
detached impellor.
Temperature sensor.


Main flow/return isolator(s) closed.


See SealedCH FAQ about the pressure.


--
Ed Sirett - Property maintainer and registered gas fitter.
The FAQ for uk.diy is athttp://www.diyfaq.org.uk
Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html
Sealed CH FAQhttp://www.makewrite.demon.co.uk/SealedCH.html
Choosing a Boiler FAQhttp://www.makewrite.demon.co.uk/BoilerChoice.html


Took everything apart, then back together and it started going, don't
know why. The day before I undid the screw on the outside of the pump
and I can hear the pump stop, if i push in the hole with a screwdriver
it starts. Bleed the heat exchanger and found no air. If I listen at
the rads I can hear the pump pushing water so if it is the pump what
else can I do to confirm this. The mother board has diagnostic LEDs to
show whats going on and when working and power applied some should
light, however I have never seen any of them lite. Checked temp sensor
and 1K which corresponds to cold water in Rads, CH overheat
thermostate closed. I think it could well have needed venting, which I
did but never found any air. Just hope it keeps going
Thanks


I think I will try and replace the pressure release vent valve which
is causing the loss of pressure, how easy is it to replace.
Thanks
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Anyone use the Hawk Routershop? A Lurker Woodworking 4 April 5th 06 11:50 PM
Hurco Hawk knee mill Cliff Metalworking 5 February 17th 05 01:10 PM
Hawk Jointability David Wittenberg Woodworking 1 December 6th 04 11:22 PM
Combi Boiler woes - first heating & no DHW, now DHW and no heating.... RichardS UK diy 8 April 8th 04 09:52 PM
Hayter Hawk Mower Paul Bowden UK diy 7 September 14th 03 10:41 PM


All times are GMT +1. The time now is 10:42 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"