Home |
Search |
Today's Posts |
|
UK diy (uk.d-i-y) For the discussion of all topics related to diy (do-it-yourself) in the UK. All levels of experience and proficency are welcome to join in to ask questions or offer solutions. |
Reply |
|
LinkBack | Thread Tools | Display Modes |
#1
|
|||
|
|||
lighting rose driving me nuts arrrr help!!!!!!!!!
Hi I got a house 60s and I have replaced my rose with a new one.
Now I have 2 black wire one was by its self and one was wound round 1 thicker black/very dark gray wire + 2 red live wires wound together In the old rose the 2 red went to one wire the black and gray and one of the black went to the other connection and the last black wire to an earth that was not wired up to anything . I connected the 2 reds to the brow live of the new rose the gray and black to the neutral and the final black to the earth. When I replaced the fuse the light was inverted and was on when it should be off and when I turned it off it blew the fuse. So I swapped them around made no difference. Now I have placed the thicker gray in the neutral and the live in the live and the 2 black in the earth and now the lamp stays on all the time. I have tried every combination, and it is either inverted or always on or always off. Help |
#2
|
|||
|
|||
lighting rose driving me nuts arrrr help!!!!!!!!!
In article ,
"db" wrote: Now I have placed the thicker gray in the neutral and the live in the live and the 2 black in the earth and now the lamp stays on all the time. I have tried every combination, and it is either inverted or always on or always off. You need a wiring diagram. I made exactly the same mistake when my daughter pulled one of the wires out changing a bulb. The mistake I made was not to credit that the wire could reach across to the switch. Finally I realised I needed help and consulted the Collins DIY manual. One of the roses detailed in there was what I had and then it was fixed. Get yourself a relevant book before proceeding or call a sparky. Peter -- Peter Ashby School of Life Sciences, University of Dundee, Scotland To assume that I speak for the University of Dundee is to be deluded. Reverse the Spam and remove to email me. |
#3
|
|||
|
|||
lighting rose driving me nuts arrrr help!!!!!!!!!
In article ,
db wrote: When I replaced the fuse the light was inverted and was on when it should be off and when I turned it off it blew the fuse. Many ceiling roses from a DIY store include a wiring diagram. There are also DIY books on the subject. Studying the diagram should make it obvious what you've done which is about the most common mistake people make when first playing around with electricity. It should act as a good lesson - to understand what you're doing before doing it. Mains electricity isn't a toy. -- *Procrastination is the art of keeping up with yesterday. Dave Plowman London SW 12 RIP Acorn |
#4
|
|||
|
|||
lighting rose driving me nuts arrrr help!!!!!!!!!
Many ceiling roses from a DIY store include a wiring diagram. There are
also DIY books on the subject. Studying the diagram should make it obvious what you've done which is about the most common mistake people make when first playing around with electricity. *Procrastination is the art of keeping up with yesterday. Dave Plowman London SW 12 RIP Acorn Or have a look a nice web page such as http://www.userview.net/loop1.html Adam |
#5
|
|||
|
|||
lighting rose driving me nuts arrrr help!!!!!!!!!
"ARWadsworth" wrote in message ... Many ceiling roses from a DIY store include a wiring diagram. There are also DIY books on the subject. Studying the diagram should make it obvious what you've done which is about the most common mistake people make when first playing around with electricity. *Procrastination is the art of keeping up with yesterday. Dave Plowman London SW 12 RIP Acorn Or have a look a nice web page such as http://www.userview.net/loop1.html Adam Or call in one of the over paid, under-qualified chimps that are slated on here from time to time....is that the smell of more cream heading in the direction of a sparky? Richard. |
#6
|
|||
|
|||
lighting rose driving me nuts arrrr help!!!!!!!!!
"ARWadsworth" wrote in
: Or have a look a nice web page such as http://www.userview.net/loop1.html Adam Thasser nice site Mike R |
#7
|
|||
|
|||
lighting rose driving me nuts arrrr help!!!!!!!!!
In article ,
Frisket wrote: Or call in one of the over paid, under-qualified chimps that are slated on here from time to time....is that the smell of more cream heading in the direction of a sparky? Not at all. But you really should read up about doing this sort of job before starting. Or even ask here *before* it all goes pear shaped. -- *How many roads must a man travel down before he admits he is lost? * Dave Plowman London SW 12 RIP Acorn |
#8
|
|||
|
|||
lighting rose driving me nuts arrrr help!!!!!!!!!
"ARWadsworth" wrote in
: Or have a look a nice web page such as http://www.userview.net/loop1.html Adam And/or follow this advice (assuming you have a loop in ceiling rose). 1. Switch off the power. 2. Use some form of continuity tester to discover which cable goes to the switch. 3. Connect all the other blacks together via the N terminal. 4. Connect all the other reds together via the L terminal. 5. Connect all the green & Yellows together via the E (or funny earth symbol terminal 6. Take the black from the switch wire and either put some red sleeve or a bit of red insulating tape on it and connect it to the remaining terminal. 7. Connect the fitting brown wire to the L terminal 8. Connect the fitting blue wire to the N terminal 9. Connect the fitting green & yellow (if present) to the E terminal. |
#9
|
|||
|
|||
lighting rose driving me nuts arrrr help!!!!!!!!!
Rule no.1 - always note the connections before you remove the old
rose! :-) From what you have said, I would deduce the following: The black wire wound round the dark grey wire is neutral. The 2 red wires wound together are live. The black wire on its own is switched live. Use a test screwdriver/ multimeter to deduce which wire is going to your wall switch and open the switch as well to see what type/colour of flex is present there. |
#10
|
|||
|
|||
lighting rose driving me nuts arrrr help!!!!!!!!!
ARWadsworth wrote:
Many ceiling roses from a DIY store include a wiring diagram. There are also DIY books on the subject. Studying the diagram should make it obvious what you've done which is about the most common mistake people make when first playing around with electricity. *Procrastination is the art of keeping up with yesterday. Dave Plowman London SW 12 RIP Acorn Or have a look a nice web page such as http://www.userview.net/loop1.html Wish I knew about that before. Daughter did same thing, ripped out old rose to fit Ikea rubbish and realised she didn't know how to rewire. I had to email her a sketch and then remotely diagnose what was what. She only had neon screwdriver. It took 3 goes to get it right, no shorts or bangs on the way though. |
#11
|
|||
|
|||
lighting rose driving me nuts arrrr help!!!!!!!!!
I would have looked in the switch first, but there are 5 wires, as he
describes, 2 switch and 3 feed, and what worries me is did the last occupier use an earth for carrying current ie switch wire |
#12
|
|||
|
|||
lighting rose driving me nuts arrrr help!!!!!!!!!
"Mike Ring" wrote in message
52.50... "ARWadsworth" wrote Or have a look a nice web page such as http://www.userview.net/loop1.html Thasser nice site Pretty pictures, but see how many mistakes you can spot on the page about fuses at http://www.userview.net/consumerunit_fuses.html. -- Andy |
#13
|
|||
|
|||
lighting rose driving me nuts arrrr help!!!!!!!!!
"Andy Wade" wrote in
: Pretty pictures, but see how many mistakes you can spot on the page about fuses at http://www.userview.net/consumerunit_fuses.html. -- Andy You've got me there, I must confess I went straight from fusewire to MCBs. So I guess it's not such a nice site Mike R |
#14
|
|||
|
|||
lighting rose driving me nuts arrrr help!!!!!!!!!
"Mike Ring" wrote in message 52.50... "Andy Wade" wrote in : Pretty pictures, but see how many mistakes you can spot on the page about fuses at http://www.userview.net/consumerunit_fuses.html. -- Andy You've got me there, I must confess I went straight from fusewire to MCBs. So I guess it's not such a nice site Mike R I never looked further than the lighting page. I see the mistakes but I still believe the lighting pictures are ok. A picture is worth a thousand words. Adam |
#15
|
|||
|
|||
lighting rose driving me nuts arrrr help!!!!!!!!!
"Mike Ring" wrote in message
52.50... You've got me there, I must confess I went straight from fusewire to MCBs. Well this is what I sent to them via their feedback form: There are several mistakes on your page about fuses at: http://www.userview.net/consumerunit_fuses.html 1. The standard is BS 1361 not BS 1362 (1362 is for plug top fuses). 2. For immersion heater you meant to say 15 or 20 amp, not 5 or 20 amp! 3. For radial circuits the allowable floor areas were increased some years ago: 50m^2 for the 20A circuit and 75m^2 for the 30A circuit. 4. Many showers (over about 7kW) will require a 45A fuse, not 30A as stated. 5. On this page about fuses, the picture shows a consumer unit with MCB's!" I could have gone on: how often will a domestic immersion or storage heater circuit require a 20A fuse? Anyway, I received a very polite reply saying that they welcome the feedback and will continue "to continuously improve" (sic.) the site. Oh, and could I check all the wiring digrams for them! I think I'll send them a quotation for doing that... So I guess it's not such a nice site I hadn't come across it before. The pictures are nice, most of the electrical information is OK, but, like everything on the Web, there are traps for the unwary novice. -- Andy |
#16
|
|||
|
|||
lighting rose driving me nuts arrrr help!!!!!!!!!
Martin Angove wrote in message ...
Because I know you didn't mean it :-)... shouldn't it be: Yes, should learn to put my brain in gear before engaging my typing fingers! |
#17
|
|||
|
|||
lighting rose driving me nuts arrrr help!!!!!!!!!
Martin Angove wrote in message ...
Because I know you didn't mean it :-)... shouldn't it be: Yes, should learn to put my brain in gear before engaging my typing fingers! |
#18
|
|||
|
|||
lighting rose driving me nuts arrrr help!!!!!!!!!
|
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|