Hi all

As the subject really. Is there any reason why I shouldn't pipe an overflow
from the side of a cistern down and under said cistern and tee into flush
pipe?
If so, is there a reducing tee type fitting that would take 22mm overflow
pipe into the side of 38mm flush pipe?
The current overflow goes into a room soon to be a kitchen (hopefully).
I want to keep the existing cistern, box it in and fit a back to wall pan.
This way I have one toilet in the house that gives a decent flush volume
(unlike the flush three times 6Litre models currently on the market).


TIA

Phil


  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 113
Default Low Level Cistern - Connect Overflow to Flush Pipe

On Tue, 6 Mar 2007 14:47:00 -0000, "TheScullster"
wrote:

Hi all

As the subject really. Is there any reason why I shouldn't pipe an overflow
from the side of a cistern down and under said cistern and tee into flush
pipe?
If so, is there a reducing tee type fitting that would take 22mm overflow
pipe into the side of 38mm flush pipe?
The current overflow goes into a room soon to be a kitchen (hopefully).
I want to keep the existing cistern, box it in and fit a back to wall pan.
This way I have one toilet in the house that gives a decent flush volume
(unlike the flush three times 6Litre models currently on the market).


TIA

Phil


So long as the flush pipe doesn't get blocked furth of the overflow
connection and the cistern doesn't overflow at the same time ...bit
unlikely I admit ...suppose it's the same with syphons with builtin
overflow arrangements ....did you consider changing to one of them ?
  #3   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 85
Default Low Level Cistern - Connect Overflow to Flush Pipe


"TheScullster" wrote in message
...
Hi all

As the subject really. Is there any reason why I shouldn't pipe an
overflow from the side of a cistern down and under said cistern and tee
into flush pipe?
If so, is there a reducing tee type fitting that would take 22mm overflow
pipe into the side of 38mm flush pipe?
The current overflow goes into a room soon to be a kitchen (hopefully).
I want to keep the existing cistern, box it in and fit a back to wall pan.
This way I have one toilet in the house that gives a decent flush volume
(unlike the flush three times 6Litre models currently on the market).


TIA

Phil

Call me a cowboy - but here goes ..................
When I fitted my cloakroom out a few years ago, the only option I had for
the overflow was to run it about 8 metres through my lounge.
I ended up drilling a hole in the top of the soil pipe and feeding the
overflow, incorporating a u-bend directly into this and sealing with
silicone - topping up the u-bend with water to create an air lock.
Afterwards I thought that the water in the u-bend would soon dry up and I
would forever be smelling the contents of the drain through the cistern but
we've never smelt anything and I've only topped the trap up once !


  #4   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,982
Default Low Level Cistern - Connect Overflow to Flush Pipe

On Tue, 06 Mar 2007 15:57:34 +0000, Franko wrote:

When I fitted my cloakroom out a few years ago, the only option I had for
the overflow was to run it about 8 metres through my lounge.
I ended up drilling a hole in the top of the soil pipe and feeding the
overflow, incorporating a u-bend directly into this and sealing with
silicone - topping up the u-bend with water to create an air lock.
Afterwards I thought that the water in the u-bend would soon dry up and I
would forever be smelling the contents of the drain through the cistern but
we've never smelt anything and I've only topped the trap up once !


Maybe you've got an overflow that's keeping it topped up and because you
haven't fitted a tundish you can't see it!

Call me a cowboy - but here goes ..................


yeee - haaah!
  #5   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,982
Default Low Level Cistern - Connect Overflow to Flush Pipe

On Tue, 06 Mar 2007 14:47:00 +0000, TheScullster wrote:

Hi all

As the subject really. Is there any reason why I shouldn't pipe an overflow
from the side of a cistern down and under said cistern and tee into flush
pipe?
If so, is there a reducing tee type fitting that would take 22mm overflow
pipe into the side of 38mm flush pipe?
The current overflow goes into a room soon to be a kitchen (hopefully).
I want to keep the existing cistern, box it in and fit a back to wall pan.
This way I have one toilet in the house that gives a decent flush volume
(unlike the flush three times 6Litre models currently on the market).


You can do it and IIRC BES have bits for doing so but it looks sh1t3
(unless it's all concealed). There are various alternative flush valves
with internal overflow you could use. If you have a standard size
syphon valve you can get 8" ones which are usually low enough to overflow
internally, or there are flap valves (which can use a regular-looking
handle) or push-button valves (many dual-flush) from Multiquick and Opella.


  #6   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,066
Default Low Level Cistern - Connect Overflow to Flush Pipe


"John Stumbles" wrote in message
news
On Tue, 06 Mar 2007 14:47:00 +0000, TheScullster wrote:

Hi all

As the subject really. Is there any reason why I shouldn't pipe an
overflow
from the side of a cistern down and under said cistern and tee into flush
pipe?
If so, is there a reducing tee type fitting that would take 22mm overflow
pipe into the side of 38mm flush pipe?
The current overflow goes into a room soon to be a kitchen (hopefully).
I want to keep the existing cistern, box it in and fit a back to wall
pan.
This way I have one toilet in the house that gives a decent flush volume
(unlike the flush three times 6Litre models currently on the market).


You can do it and IIRC BES have bits for doing so but it looks sh1t3
(unless it's all concealed). There are various alternative flush valves
with internal overflow you could use. If you have a standard size
syphon valve you can get 8" ones which are usually low enough to overflow
internally, or there are flap valves (which can use a regular-looking
handle) or push-button valves (many dual-flush) from Multiquick and
Opella.


Yes, it's much, much better to fit a new siphon with built in overflow. You
can go to the flush pipe but it should be via a tundish (where the pipe
ends, there's a gap and then more pipe with a flared top to catch the flow -
this gives the required air break) and it looks (as he says) sh1t. You can
get interna;l overflow siphons from B&Q (I think).


--
Bob Mannix
(anti-spam is as easy as 1-2-3 - not)


  #7   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 3,356
Default Low Level Cistern - Connect Overflow to Flush Pipe

On Tue, 6 Mar 2007 14:47:00 -0000 someone who may be "TheScullster"
wrote this:-

As the subject really. Is there any reason why I shouldn't pipe an overflow
from the side of a cistern down and under said cistern and tee into flush
pipe?


Provided it is allowed in your area.

If so, is there a reducing tee type fitting that would take 22mm overflow
pipe into the side of 38mm flush pipe?


There certainly used to be. It clamped onto the flush pipe with some
bolts and had a side connection for the overflow.

Alternatively, as has already been suggested, replace the siphon
with one with an internal overflow.



--
David Hansen, Edinburgh
I will *always* explain revoked encryption keys, unless RIP prevents me
http://www.opsi.gov.uk/acts/acts2000/00023--e.htm#54
  #8   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 229
Default Low Level Cistern - Connect Overflow to Flush Pipe

On Mar 6, 4:38 pm, "Bob Mannix" wrote:
"John Stumbles" wrote in message

news




On Tue, 06 Mar 2007 14:47:00 +0000, TheScullster wrote:


Hi all


As the subject really. Is there any reason why I shouldn't pipe an
overflow
from the side of a cistern down and under said cistern and tee into flush
pipe?
If so, is there a reducing tee type fitting that would take 22mm overflow
pipe into the side of 38mm flush pipe?
The current overflow goes into a room soon to be a kitchen (hopefully).
I want to keep the existing cistern, box it in and fit a back to wall
pan.
This way I have one toilet in the house that gives a decent flush volume
(unlike the flush three times 6Litre models currently on the market).


You can do it and IIRC BES have bits for doing so but it looks sh1t3
(unless it's all concealed). There are various alternative flush valves
with internal overflow you could use. If you have a standard size
syphon valve you can get 8" ones which are usually low enough to overflow
internally, or there are flap valves (which can use a regular-looking
handle) or push-button valves (many dual-flush) from Multiquick and
Opella.


Yes, it's much, much better to fit a new siphon with built in overflow. You
can go to the flush pipe but it should be via a tundish (where the pipe
ends, there's a gap and then more pipe with a flared top to catch the flow -
this gives the required air break) and it looks (as he says) sh1t. You can
get interna;l overflow siphons from B&Q (I think).

--


As I udnerstand it, and I could be wrong, there's no requirement for a
visible tundish as one would be able to see the overflow flowing into
the pan. That's why the european style flappers are now allowed.

  #9   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,066
Default Low Level Cistern - Connect Overflow to Flush Pipe


"adder1969" wrote in message
oups.com...
On Mar 6, 4:38 pm, "Bob Mannix" wrote:
"John Stumbles" wrote in message

news




On Tue, 06 Mar 2007 14:47:00 +0000, TheScullster wrote:


Hi all


As the subject really. Is there any reason why I shouldn't pipe an
overflow
from the side of a cistern down and under said cistern and tee into
flush
pipe?
If so, is there a reducing tee type fitting that would take 22mm
overflow
pipe into the side of 38mm flush pipe?
The current overflow goes into a room soon to be a kitchen
(hopefully).
I want to keep the existing cistern, box it in and fit a back to wall
pan.
This way I have one toilet in the house that gives a decent flush
volume
(unlike the flush three times 6Litre models currently on the market).


You can do it and IIRC BES have bits for doing so but it looks sh1t3
(unless it's all concealed). There are various alternative flush valves
with internal overflow you could use. If you have a standard size
syphon valve you can get 8" ones which are usually low enough to
overflow
internally, or there are flap valves (which can use a regular-looking
handle) or push-button valves (many dual-flush) from Multiquick and
Opella.


Yes, it's much, much better to fit a new siphon with built in overflow.
You
can go to the flush pipe but it should be via a tundish (where the pipe
ends, there's a gap and then more pipe with a flared top to catch the
flow -
this gives the required air break) and it looks (as he says) sh1t. You
can
get interna;l overflow siphons from B&Q (I think).

--


As I udnerstand it, and I could be wrong, there's no requirement for a
visible tundish as one would be able to see the overflow flowing into
the pan. That's why the european style flappers are now allowed.


It *may* be the case that the regs have changed and the tundish is not
required (don't know) but it wasn't so you could see an overflow, it was to
provide an air break between the pan and the cistern.


--
Bob Mannix
(anti-spam is as easy as 1-2-3 - not)



  #10   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,283
Default Low Level Cistern - Connect Overflow to Flush Pipe


"David Hansen" wrote

There certainly used to be. It clamped onto the flush pipe with some
bolts and had a side connection for the overflow.

Alternatively, as has already been suggested, replace the siphon
with one with an internal overflow.

The syphons I've seen with internal overflow provision, do so with a very
small hole.
These look like they would only accomodate a slight weep of the float
valve - anything worse hitting the floor!
Are there syphons out there that can cope with overflow from a serious valve
failure?
The feed to my cistern is low pressure.

Thanks

Phil




  #11   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,066
Default Low Level Cistern - Connect Overflow to Flush Pipe


"TheScullster" wrote in message
...

"David Hansen" wrote

There certainly used to be. It clamped onto the flush pipe with some
bolts and had a side connection for the overflow.

Alternatively, as has already been suggested, replace the siphon
with one with an internal overflow.

The syphons I've seen with internal overflow provision, do so with a very
small hole.
These look like they would only accomodate a slight weep of the float
valve - anything worse hitting the floor!
Are there syphons out there that can cope with overflow from a serious
valve failure?
The feed to my cistern is low pressure.


The very small hole is to allow air to escape so the siphon fills (otherwise
it wouldn't). Once full it flushes the toilet, the small hole not being
enough to break the siphon. This empties the cistern as per normal and the
cycle repeats. It should thus be able to deal with at least a cictern
filling permanently at its normal full rate.


--
Bob Mannix
(anti-spam is as easy as 1-2-3 - not)


  #12   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 113
Default Low Level Cistern - Connect Overflow to Flush Pipe

On Wed, 7 Mar 2007 08:31:09 -0000, "Bob Mannix"
wrote:


"TheScullster" wrote in message
...

"David Hansen" wrote

There certainly used to be. It clamped onto the flush pipe with some
bolts and had a side connection for the overflow.

Alternatively, as has already been suggested, replace the siphon
with one with an internal overflow.

The syphons I've seen with internal overflow provision, do so with a very
small hole.
These look like they would only accomodate a slight weep of the float
valve - anything worse hitting the floor!
Are there syphons out there that can cope with overflow from a serious
valve failure?
The feed to my cistern is low pressure.


The very small hole is to allow air to escape so the siphon fills (otherwise
it wouldn't). Once full it flushes the toilet, the small hole not being
enough to break the siphon. This empties the cistern as per normal and the
cycle repeats. It should thus be able to deal with at least a cictern
filling permanently at its normal full rate.


Unless the waste pipe blocks at the same time in which case you are in
the S*** ....That was the advantage of seperate overflows to outside
....Unlikely I agree tho'
  #13   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 3,356
Default Low Level Cistern - Connect Overflow to Flush Pipe

On Wed, 07 Mar 2007 11:00:15 +0000 someone who may be Stuart B
wrote this:-

The very small hole is to allow air to escape so the siphon fills (otherwise
it wouldn't). Once full it flushes the toilet, the small hole not being
enough to break the siphon. This empties the cistern as per normal and the
cycle repeats. It should thus be able to deal with at least a cictern
filling permanently at its normal full rate.


Unless the waste pipe blocks at the same time in which case you are in
the S*** ....That was the advantage of seperate overflows to outside
...Unlikely I agree tho'


However, a dripping warning pipe in winter can slowly freeze solid,
with predictable results, so it is a matter of swings and
roundabouts.


--
David Hansen, Edinburgh
I will *always* explain revoked encryption keys, unless RIP prevents me
http://www.opsi.gov.uk/acts/acts2000/00023--e.htm#54
  #14   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 113
Default Low Level Cistern - Connect Overflow to Flush Pipe

On Wed, 07 Mar 2007 12:35:36 +0000, David Hansen
wrote:

On Wed, 07 Mar 2007 11:00:15 +0000 someone who may be Stuart B
wrote this:-

The very small hole is to allow air to escape so the siphon fills (otherwise
it wouldn't). Once full it flushes the toilet, the small hole not being
enough to break the siphon. This empties the cistern as per normal and the
cycle repeats. It should thus be able to deal with at least a cictern
filling permanently at its normal full rate.


Unless the waste pipe blocks at the same time in which case you are in
the S*** ....That was the advantage of seperate overflows to outside
...Unlikely I agree tho'


However, a dripping warning pipe in winter can slowly freeze solid,
with predictable results, so it is a matter of swings and
roundabouts.


Freezing winters ..Nah..That was years ago .haven't you heard of
global warming ..lol?
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Cistern Overflow [email protected] UK diy 6 September 5th 05 08:43 PM
How do I connect a 1.25" PVC-U pipe to the flush 50mm plain female water inlet of a WC pan? Peter UK diy 0 August 3rd 05 11:06 PM
High level cistern flush too powerful steve UK diy 3 February 28th 04 04:28 PM
New cistern, no overflow? Ben Blaukopf UK diy 4 February 6th 04 09:20 PM
cistern overflow dave UK diy 33 December 30th 03 12:10 PM


All times are GMT +1. The time now is 12:08 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"