UK diy (uk.d-i-y) For the discussion of all topics related to diy (do-it-yourself) in the UK. All levels of experience and proficency are welcome to join in to ask questions or offer solutions.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to uk.d-i-y
Mark
 
Posts: n/a
Default Halogen down lighters - spacing for kitchen

Hi

I was wondering if there are any guidelines as to how close together
these need to be for a kitchen where we will have an approx. 4m run of
work top in an L shape with no wall cupboards.

I am considering the mains voltage 50W type, and want a bright working
area.

TIA
--
Mark
  #2   Report Post  
Posted to uk.d-i-y
Andrew Gabriel
 
Posts: n/a
Default Halogen down lighters - spacing for kitchen

In article ,
Mark writes:
Hi

I was wondering if there are any guidelines as to how close together
these need to be for a kitchen where we will have an approx. 4m run of
work top in an L shape with no wall cupboards.

I am considering the mains voltage 50W type, and want a bright working
area.


Oh dear.
I suggest you read back through earlier threads on halogen
downlighters before going that route ;-)

--
Andrew Gabriel
  #3   Report Post  
Posted to uk.d-i-y
 
Posts: n/a
Default Halogen down lighters - spacing for kitchen

Mark wrote:
Hi

I was wondering if there are any guidelines as to how close together
these need to be for a kitchen where we will have an approx. 4m run of
work top in an L shape with no wall cupboards.

I am considering the mains voltage 50W type, and want a bright working
area.

TIA


If I may suggest, these arent one of the best possible choices. If you
want the look of halogen downlights you'd do better to use 20w
halogens, and make up the remaining light level with CFLs.

As Andrew said, google, groups, uk.d-i-y for the problems with them.


NT

  #4   Report Post  
Posted to uk.d-i-y
The Natural Philosopher
 
Posts: n/a
Default Halogen down lighters - spacing for kitchen

On Sun, 08 Jan 2006 19:45:31 GMT, Mark wrote:

Hi

I was wondering if there are any guidelines as to how close together
these need to be for a kitchen where we will have an approx. 4m run of
work top in an L shape with no wall cupboards.

I am considering the mains voltage 50W type, and want a bright working
area.

TIA


For gods sake get LV and save yourself from expensive bulb replacements
every fortnight. Every person I know with mains halogens hates the bloody
things and has ripped them out - when you end up with half the lights blown
every two months...so will you.

How does 4 years average lifetime in a busy are grab you on my 50W LV
spots? And bulb price less than half the mains ones?


I would put about 1 every meter frankly. Over the worktop. For general
lighting 2-5 square meters per bulb, and get wide angle ones. Eyeball
firttings enable you to use a bit less, by allowing you to set where the
bright patches are.

  #5   Report Post  
Posted to uk.d-i-y
The Natural Philosopher
 
Posts: n/a
Default Halogen down lighters - spacing for kitchen

On 8 Jan 2006 12:48:47 -0800, wrote:

Mark wrote:
Hi

I was wondering if there are any guidelines as to how close together
these need to be for a kitchen where we will have an approx. 4m run of
work top in an L shape with no wall cupboards.

I am considering the mains voltage 50W type, and want a bright working
area.

TIA


If I may suggest, these arent one of the best possible choices. If you
want the look of halogen downlights you'd do better to use 20w
halogens, and make up the remaining light level with CFLs.

As Andrew said, google, groups, uk.d-i-y for the problems with them.

NT


I have only two problems with mine, and they are electricity consumption,
and I didn;t put enough in perhaps.

Everyone who has used mains ones I know wishes they hadn't, but I am well
chuffed with the LV ones.

Compared with Her mood lighting wall mounted candle bulbs, which blow a
bulb a week, I am replacing LV spots in similar illumination areas at the
rate of 3 or 4 a year only. I reaplaced 6 40W candles last month
alone...and so far they have blown two dimmers (now uprated )and have a 75%
sucess rate in triping a 6A MCB when they blow...

If you are mean and green, use CFL's - but if you want the best lighting
quality and accurate illumination, LV halogens are very very good. Mine
even dim bless them.Do your sums on electricoity consumption, capital cost
and MTBF and make up your own mind.




  #6   Report Post  
Posted to uk.d-i-y
Tony Bryer
 
Posts: n/a
Default Halogen down lighters - spacing for kitchen

On Tue, 10 Jan 2006 02:19:10 +0000 The Natural Philosopher wrote :
If you are mean and green, use CFL's - but if you want the best
lighting quality and accurate illumination, LV halogens are very very
good. Mine even dim bless them.Do your sums on electricoity
consumption, capital cost and MTBF and make up your own mind.


I guess I'm mean and green but think these halogen spots (mains or LV) to
be a stupid affectation. The more so since my mother had the bright idea
of getting the 2 x 4' fluorescents in her kitchen changed to 2 x 4 x 50W
mains halogen spots and I'm the one who gets to change the bulbs. Nasty
light with hard shadows in front of you just where you are working (of
course due to the fittings being centre ceiling) and costing five times
as much in energy and lamp replacements.

--
Tony Bryer SDA UK 'Software to build on' http://www.sda.co.uk
Free SEDBUK boiler database browser http://www.sda.co.uk/qsedbuk.htm
[Latest version QSEDBUK 1.12 released 8 Dec 2005]


  #7   Report Post  
Posted to uk.d-i-y
 
Posts: n/a
Default Halogen down lighters - spacing for kitchen

Just fitted 6 times 50W LV recessed lights last weekend. Very pleased
with result.
Spacing about 1m

  #9   Report Post  
Posted to uk.d-i-y
mitchd
 
Posts: n/a
Default Halogen down lighters - spacing for kitchen

The Natural Philosopher wrote:
On Sun, 08 Jan 2006 19:45:31 GMT, Mark wrote:


Hi

I was wondering if there are any guidelines as to how close together
these need to be for a kitchen where we will have an approx. 4m run of
work top in an L shape with no wall cupboards.

I am considering the mains voltage 50W type, and want a bright working
area.

TIA



For gods sake get LV and save yourself from expensive bulb replacements
every fortnight. Every person I know with mains halogens hates the bloody
things and has ripped them out - when you end up with half the lights blown
every two months...so will you.

How does 4 years average lifetime in a busy are grab you on my 50W LV
spots? And bulb price less than half the mains ones?


I would put about 1 every meter frankly. Over the worktop. For general
lighting 2-5 square meters per bulb, and get wide angle ones. Eyeball
firttings enable you to use a bit less, by allowing you to set where the
bright patches are.


I use 1.2 to 1.5m spacing, i have fitted loads of mains voltage halogen
on diff jobs, 50w lamps cost £2 each last app 1 year in my own kitchen
7 lights for 6x3m floor area, I use "task lighting" for worktop areas,
linkable striplights screwfix No 98307, don't like lv downlights 50/50
chance transformer or lamp wiil blow first

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
HELP: halogen vs energy-saving light bulb.... woes :S KevinGPO UK diy 32 January 16th 06 12:58 PM
Light output of dimmed lamps CJT Home Repair 67 December 30th 05 01:21 AM
spindle spacing [email protected] Woodworking 3 September 9th 05 06:49 PM
Railing Baluster Spacing Zimmer Woodworking 8 July 6th 05 03:25 AM
Crap B&Q Mains Halogen Spots Mr Angry UK diy 37 March 24th 04 04:29 PM


All times are GMT +1. The time now is 12:07 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 