Hello, all.
Here's what I have: - 8 HP Briggs & Stratton IC engine - Haldex/Barnes 16 GPM direct drive hydraulic pump - Prince "Logsplitter" vavlve (like can be seen he http://www.northerntool.com/webapp/wcs/stores/servlet/product_6970_472_472?cm_sp=Customer%20driven-_-Recently%20Viewed-_-Product%20Page" - 4 inch bore, 30 inch stroke cylinder - 3.5 inch bore, 36 inch stroke cylinder What works: The engine, hydraulic pump, valve, and 4x30 cylinder are used as a log splitter. Work great. No problems. What does't work: I disconnected the 4x30 cylinder and connected a 3.5 x 36 bore cylinder for another project (with about 10 feet of hydraulic hose I can use the logsplitter as a power supply for other hydraulic projects, which is what I'm doing). Whereas on the logsplitter ram- speed is not a concern, my current project is sensitive to ram speed. When I move the handle of the spool slightly to move the ram at low speed the ram moves very slowly, no problem, until it hits the load and then the engine bogs and dies. However, when I move the handle to full-open against the load the ram moves just fine, but way too fast for my needs and control. The problem is that I need to be able to control the speed of the hydraulic ram in my current project but when I try to move the handle of the vavle slightly, to move the ram slowly, it bogs the engine and will kill it, under load. It's got to be the valve or the pump, but I don't know enough about these things to be sure which it is. I would guess the valve is the problem, maybe restricting the fluid too much on partial engagement....but I don't really understand the inner workings of these things well enough to even form a theory. Any help would be appreciated. Thank you. --HC |
#2
![]()
Posted to rec.crafts.metalworking
|
|||
|
|||
![]()
id try more rotating mass on the engine side.
|
#3
![]()
Posted to rec.crafts.metalworking
|
|||
|
|||
![]()
HC wrote:
Hello, all. Here's what I have: - 8 HP Briggs & Stratton IC engine - Haldex/Barnes 16 GPM direct drive hydraulic pump - Prince "Logsplitter" vavlve (like can be seen he http://www.northerntool.com/webapp/wcs/stores/servlet/product_6970_472_472?cm_sp=Customer%20driven-_-Recently%20Viewed-_-Product%20Page" - 4 inch bore, 30 inch stroke cylinder - 3.5 inch bore, 36 inch stroke cylinder What works: The engine, hydraulic pump, valve, and 4x30 cylinder are used as a log splitter. Work great. No problems. What does't work: I disconnected the 4x30 cylinder and connected a 3.5 x 36 bore cylinder for another project (with about 10 feet of hydraulic hose I can use the logsplitter as a power supply for other hydraulic projects, which is what I'm doing). Whereas on the logsplitter ram- speed is not a concern, my current project is sensitive to ram speed. When I move the handle of the spool slightly to move the ram at low speed the ram moves very slowly, no problem, until it hits the load and then the engine bogs and dies. However, when I move the handle to full-open against the load the ram moves just fine, but way too fast for my needs and control. The problem is that I need to be able to control the speed of the hydraulic ram in my current project but when I try to move the handle of the vavle slightly, to move the ram slowly, it bogs the engine and will kill it, under load. It's got to be the valve or the pump, but I don't know enough about these things to be sure which it is. I would guess the valve is the problem, maybe restricting the fluid too much on partial engagement....but I don't really understand the inner workings of these things well enough to even form a theory. Any help would be appreciated. Thank you. --HC Log splitter valves are cheap n nasty and have no real need to be able to feathered, ie used to choke the flow. A solution and quite cheap, would be a Prince adjustable flow control valve in your system: http://tinyurl.com/23btm3 Tom |
#4
![]()
Posted to rec.crafts.metalworking
|
|||
|
|||
![]()
On Aug 6, 1:47 am, Tom wrote:
HC wrote: Hello, all. Here's what I have: - 8 HP Briggs & Stratton IC engine - Haldex/Barnes 16 GPM direct drive hydraulic pump - Prince "Logsplitter" vavlve (like can be seen he http://www.northerntool.com/webapp/wcs/stores/servlet/product_6970_47..." - 4 inch bore, 30 inch stroke cylinder - 3.5 inch bore, 36 inch stroke cylinder What works: The engine, hydraulic pump, valve, and 4x30 cylinder are used as a log splitter. Work great. No problems. What does't work: I disconnected the 4x30 cylinder and connected a 3.5 x 36 bore cylinder for another project (with about 10 feet of hydraulic hose I can use the logsplitter as a power supply for other hydraulic projects, which is what I'm doing). Whereas on the logsplitter ram- speed is not a concern, my current project is sensitive to ram speed. When I move the handle of the spool slightly to move the ram at low speed the ram moves very slowly, no problem, until it hits the load and then the engine bogs and dies. However, when I move the handle to full-open against the load the ram moves just fine, but way too fast for my needs and control. The problem is that I need to be able to control the speed of the hydraulic ram in my current project but when I try to move the handle of the vavle slightly, to move the ram slowly, it bogs the engine and will kill it, under load. It's got to be the valve or the pump, but I don't know enough about these things to be sure which it is. I would guess the valve is the problem, maybe restricting the fluid too much on partial engagement....but I don't really understand the inner workings of these things well enough to even form a theory. Any help would be appreciated. Thank you. --HC Log splitter valves are cheap n nasty and have no real need to be able to feathered, ie used to choke the flow. A solution and quite cheap, would be a Prince adjustable flow control valve in your system:http://tinyurl.com/23btm3 Tom- Hide quoted text - - Show quoted text - Thank you Tom for your reply, that might be the trick. After several readings I'm going to attempt to adjust the bypass valve and see if that makes a difference. I doubt it will since the engine doesn't die when I have it against the end of the hydraulic cylinder travel, fully stopped but with the valve fully open so the bypass must be working. but it's a quick and cheap attempt to fix the problem. I have a pressure gauge on the system so I can see where I set it. The frustrating part is that, and I need to verify this, the pressure was only a few hundred pounds when the valve was barely open and it was killing the engine. Who knows. I need to verify my data by doing it again and paying more attention. Thank you for your suggestion. --HC |
#5
![]()
Posted to rec.crafts.metalworking
|
|||
|
|||
![]()
On Aug 6, 1:14 am, HC wrote:
Hello, all. ... - ... Prince "Logsplitter" vavlve (like can be seen hehttp://www.northerntool.com/webapp/wcs/stores/servlet/product_6970_47..." ...when I try to move the handle of the vavle slightly, to move the ram slowly, it bogs the engine and will kill it, under load... --HC There is an adjustable pressure relief valve under the hex cap beside the control handle shaft. Put a *hydraulic pressure rated* tee and a glycerin-filled 5000Lb pressure gauge at the pump outlet so you can see what you're doing as you adjust it. The lowest pressure that moves the load should give you the most control. I don't know the max safe setting on your system. Jim Wilkins |
#6
![]()
Posted to rec.crafts.metalworking
|
|||
|
|||
![]()
On Aug 6, 5:54 am, Jim Wilkins wrote:
On Aug 6, 1:14 am, HC wrote: Hello, all. ... - ... Prince "Logsplitter" vavlve (like can be seen hehttp://www.northerntool.com/webapp/wcs/stores/servlet/product_6970_47..." ...when I try to move the handle of the vavle slightly, to move the ram slowly, it bogs the engine and will kill it, under load... --HC There is an adjustable pressure relief valve under the hex cap beside the control handle shaft. Put a *hydraulic pressure rated* tee and a glycerin-filled 5000Lb pressure gauge at the pump outlet so you can see what you're doing as you adjust it. The lowest pressure that moves the load should give you the most control. I don't know the max safe setting on your system. Jim Wilkins Thanks, Jim, for your reply. I have a 5k glycerin filled gauge on the pump output line currently and will attempt the adjustment of the bypass. --HC |
#7
![]()
Posted to rec.crafts.metalworking
|
|||
|
|||
![]()
HC wrote:
Hello, all. Here's what I have: - 8 HP Briggs & Stratton IC engine - Haldex/Barnes 16 GPM direct drive hydraulic pump - Prince "Logsplitter" vavlve (like can be seen he http://www.northerntool.com/webapp/wcs/stores/servlet/product_6970_472_472?cm_sp=Customer%20driven-_-Recently%20Viewed-_-Product%20Page" - 4 inch bore, 30 inch stroke cylinder - 3.5 inch bore, 36 inch stroke cylinder What works: The engine, hydraulic pump, valve, and 4x30 cylinder are used as a log splitter. Work great. No problems. What does't work: I disconnected the 4x30 cylinder and connected a 3.5 x 36 bore cylinder for another project (with about 10 feet of hydraulic hose I can use the logsplitter as a power supply for other hydraulic projects, which is what I'm doing). Whereas on the logsplitter ram- speed is not a concern, my current project is sensitive to ram speed. When I move the handle of the spool slightly to move the ram at low speed the ram moves very slowly, no problem, until it hits the load and then the engine bogs and dies. However, when I move the handle to full-open against the load the ram moves just fine, but way too fast for my needs and control. The problem is that I need to be able to control the speed of the hydraulic ram in my current project but when I try to move the handle of the vavle slightly, to move the ram slowly, it bogs the engine and will kill it, under load. It's got to be the valve or the pump, but I don't know enough about these things to be sure which it is. I would guess the valve is the problem, maybe restricting the fluid too much on partial engagement....but I don't really understand the inner workings of these things well enough to even form a theory. Any help would be appreciated. Thank you. --HC I suspect the valve is not set up for partial flows. Cheap fix. An adjustable resrtictor. If it causes the valve to kick off. you may need to plumb in a bypass that allows some fluid to be tapped off for work, with the rest recirculating. More expensive, you may find it best to aquire a more suitable valve, and plumb it in for use with external hookups. Splitters, pretty much, don't require a lot of fine control. Cheers Trevor Jones |
#8
![]()
Posted to rec.crafts.metalworking
|
|||
|
|||
![]()
On Aug 6, 9:41 am, Trevor Jones wrote:
HC wrote: Hello, all. Here's what I have: - 8 HP Briggs & Stratton IC engine - Haldex/Barnes 16 GPM direct drive hydraulic pump - Prince "Logsplitter" vavlve (like can be seen he http://www.northerntool.com/webapp/wcs/stores/servlet/product_6970_47..." - 4 inch bore, 30 inch stroke cylinder - 3.5 inch bore, 36 inch stroke cylinder What works: The engine, hydraulic pump, valve, and 4x30 cylinder are used as a log splitter. Work great. No problems. What does't work: I disconnected the 4x30 cylinder and connected a 3.5 x 36 bore cylinder for another project (with about 10 feet of hydraulic hose I can use the logsplitter as a power supply for other hydraulic projects, which is what I'm doing). Whereas on the logsplitter ram- speed is not a concern, my current project is sensitive to ram speed. When I move the handle of the spool slightly to move the ram at low speed the ram moves very slowly, no problem, until it hits the load and then the engine bogs and dies. However, when I move the handle to full-open against the load the ram moves just fine, but way too fast for my needs and control. The problem is that I need to be able to control the speed of the hydraulic ram in my current project but when I try to move the handle of the vavle slightly, to move the ram slowly, it bogs the engine and will kill it, under load. It's got to be the valve or the pump, but I don't know enough about these things to be sure which it is. I would guess the valve is the problem, maybe restricting the fluid too much on partial engagement....but I don't really understand the inner workings of these things well enough to even form a theory. Any help would be appreciated. Thank you. --HC I suspect the valve is not set up for partial flows. Cheap fix. An adjustable resrtictor. If it causes the valve to kick off. you may need to plumb in a bypass that allows some fluid to be tapped off for work, with the rest recirculating. More expensive, you may find it best to aquire a more suitable valve, and plumb it in for use with external hookups. Splitters, pretty much, don't require a lot of fine control. Cheers Trevor Jones- Hide quoted text - - Show quoted text - Thank you, Trevor, someone else has suggested something similar and I'm going to try that after I try the adjustment of the bypass. I may see if I can lower the "shift" pressure on the two-stage pump, maybe having it "down-shift" at a lower pressure would help. --HC |
#9
![]()
Posted to rec.crafts.metalworking
|
|||
|
|||
![]()
On Aug 6, 6:14 am, HC wrote:
Any help would be appreciated. Thank you. --HC The pump you have is especially good for log splitters. It has two pumps in one case. When the pressure needed is low, both pumps are used and you get high volume. When the pressure needed is high, only the smaller pump is used. This reduces the load on the engine. Unfortunately it sounds as if you need a low flow all the time for your second application. Without knowing what you are doing , it is a bit difficult to make the best recommendation. But you might look at some surplus catalogs and pick out a smaller constant flow pump and maybe use an electric motor. The electric motor will run slower than the gas engine so will slow down the speed of the cylinder. THe smaller pump will also make things move slower. Dan |
#10
![]()
Posted to rec.crafts.metalworking
|
|||
|
|||
![]()
On Aug 6, 10:56 am, " wrote:
On Aug 6, 6:14 am, HC wrote: Any help would be appreciated. Thank you. --HC The pump you have is especially good for log splitters. It has two pumps in one case. When the pressure needed is low, both pumps are used and you get high volume. When the pressure needed is high, only the smaller pump is used. This reduces the load on the engine. Unfortunately it sounds as if you need a low flow all the time for your second application. Without knowing what you are doing , it is a bit difficult to make the best recommendation. But you might look at some surplus catalogs and pick out a smaller constant flow pump and maybe use an electric motor. The electric motor will run slower than the gas engine so will slow down the speed of the cylinder. THe smaller pump will also make things move slower. Dan Thanks for your reply, Dan. I have looked at a smaller pump but since I don't know the displacement of my current pump, and the manufacturer's website doesn't seem to have it, I don't know how small is too small. I thought about using an electric over hydraulic system but since I have a lot of money in the log splitter, and since I don't use it, I thought I'd get some use out of it and save some money. I'm putting in steel piers under my concrete foundation to fix it. The house is built on clay and it varies elevation pretty wildly depending on the weather. I'm in north central Texas, so we get some wet times and some very dry times and it's hell on the house, cracking walls and brick and such. It's 20k to pay professionals to do it, it's about 5k of materials to do it myself. --HC |
#11
![]()
Posted to rec.crafts.metalworking
|
|||
|
|||
![]()
On Aug 6, 12:14 am, HC wrote:
Hello, all. Here's what I have: - 8 HP Briggs & Stratton IC engine - Haldex/Barnes 16 GPM direct drive hydraulic pump - Prince "Logsplitter" vavlve (like can be seen hehttp://www.northerntool.com/webapp/wcs/stores/servlet/product_6970_47..." - 4 inch bore, 30 inch stroke cylinder - 3.5 inch bore, 36 inch stroke cylinder What works: The engine, hydraulic pump, valve, and 4x30 cylinder are used as a log splitter. Work great. No problems. What does't work: I disconnected the 4x30 cylinder and connected a 3.5 x 36 bore cylinder for another project (with about 10 feet of hydraulic hose I can use the logsplitter as a power supply for other hydraulic projects, which is what I'm doing). Whereas on the logsplitter ram- speed is not a concern, my current project is sensitive to ram speed. When I move the handle of the spool slightly to move the ram at low speed the ram moves very slowly, no problem, until it hits the load and then the engine bogs and dies. However, when I move the handle to full-open against the load the ram moves just fine, but way too fast for my needs and control. The problem is that I need to be able to control the speed of the hydraulic ram in my current project but when I try to move the handle of the vavle slightly, to move the ram slowly, it bogs the engine and will kill it, under load. It's got to be the valve or the pump, but I don't know enough about these things to be sure which it is. I would guess the valve is the problem, maybe restricting the fluid too much on partial engagement....but I don't really understand the inner workings of these things well enough to even form a theory. Any help would be appreciated. Thank you. --HC I finally found that the Haldex/Barnes 2 stage pump I have (the 16 GPM model) has a large-volume pump of, I don't remember the exact figure, but it's about 0.7 cubic inches...maybe 0.756 or so. The small-volume pump is, and this I remember accurately, is 0.258 cubic inches. So, with that knowledge I bough the smallest pump that I could find from my supplier that used the same shaft, rotation, and mounting as the 16 GPM two stage. That pump has a 0.194 cubic inch displacement. I rigged it up on the engine and to my assemblies and ran it with NO problems at all, even at full pressure, 2,250 PSI. The engine did not lug or bog at all! I then adjusted the bypass on the valve to a higher pressure. Not knowing how fine the adjustment would be I attempted a half rotation on the adjustment and then applied pressure to the cylinder. It ran over 3,000 PSI and I immediately let off the valve to return to center. But the engine had no problem with that pressure. I adjusted it finally to 2,750 PSI on the bypass, 250 PSI over the max working limit of the cylinder otherwise I'd set it to 3,000 PSI, and left it there. I can run the cylinder to load and stop the cylinder, with 2,750 PSI on the gauge, and the engine runs fine. So, either going from a 0.258 CI pump to a 0.194 CI pump really makes that much difference (it's a 25% reduction in volume) OR the two stage pump wasn't properly (if it ever would or could) shutting off the large-volume pump portion. I have a hard time thinking the 0.258 CI would KILL the engine at a load of 2,250 PSI and that the 0.194 CI pump wouldn't even bog it at over 3,000 PSI. I think that two stage pump is okay for a log splitter where there is no way a log is going to be able to resist any where near 2,250 PSI on a 4 inch bore cylinder and therefore won't ever really load the engine down, but is a poor choice for where full power operation may be necessary. Thanks again for all your help and input. I hope the results above will help somebody else. --HC |
#12
![]()
Posted to rec.crafts.metalworking
|
|||
|
|||
![]()
In article . com,
HC wrote: pressure. I adjusted it finally to 2,750 PSI on the bypass, 250 PSI over the max working limit of the cylinder otherwise I'd set it to 3,000 PSI, and left it there. I can run the cylinder to load and stop the cylinder, with 2,750 PSI on the gauge Which part of "Max Working limit" are you not getting? With a 2500 PSI working limit, a bypass at 2499 PSI or less is called for... -- Cats, coffee, chocolate...vices to live by |
#13
![]()
Posted to rec.crafts.metalworking
|
|||
|
|||
![]()
On Aug 25, 11:30 am, HC wrote:
... I think that two stage pump is okay for a log splitter where there is no way a log is going to be able to resist any where near 2,250 PSI on a 4 inch bore cylinder and therefore won't ever really load the engine down, but is a poor choice for where full power operation may be necessary. Glad to hear this is working for you. Some of the red oak I burn will definitely resist my 3-1/2" splitter at 2500PSI and needs to be cut with a chainsaw. The two-stage bypass in my hydraulic pump is a spring-loaded ball valve that opens at about 600PSI. The pump wasn't too bad to open up and work on when I replaced a bearing. I suggest having someone else with clean hands photograph it during disassembly so you can reassemble the pieces in the correct order. I recently watched Jewel on Soundstage and was very impressed. Looking her up lead to Ty Murray and his ranch in Stephenville and how much he likes that part of north central Texas. Are you anywhere nearby? jw |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Off topic : hydraulic cylinder repair | Home Repair | |||
Valve,Butterfly valve,Globe valve,Check valve,Ball valve,Plug valve,Marine valve,Gate valve,Flow control valve | UK diy | |||
who wanted a smallish hydraulic cylinder? hand pump? stuff FA | Metalworking | |||
OT - Hydraulic Cylinder sources | Metalworking | |||
Hydraulic cylinder source? | Metalworking |