Posted to alt.home.repair
|
|||
|
|||
![]()
I need to replace a water shut-off valve below my kitchen sink. I see
that valves come made to fit on either 1/2" or 5/8" pipe. When I measure the copper intake pipe with my (not very accurate) caliper it measures .66, which is a little over 5/8". I think I read somewhere that "1/2 inch" refers to the inside diameter, and that the outside diameter is closer to 5/8. True? No? So, what do I have, 1/2" or 5/8" copper pipe? I'm thinking 1/2" because it's more common, and if it were 5/8" the outside diameter might be greater than .66". Also, Home Depot has valves with Shark Bite connectors which don't require compression fittings. Are those things reliable? |
#2
![]()
Posted to alt.home.repair
|
|||
|
|||
![]()
On Sunday, June 6, 2021 at 7:47:57 PM UTC-5, Nil wrote:
I need to replace a water shut-off valve below my kitchen sink. I see that valves come made to fit on either 1/2" or 5/8" pipe. When I measure the copper intake pipe with my (not very accurate) caliper it measures .66, which is a little over 5/8". I think I read somewhere that "1/2 inch" refers to the inside diameter, and that the outside diameter is closer to 5/8. True? No? So, what do I have, 1/2" or 5/8" copper pipe? I'm thinking 1/2" because it's more common, and if it were 5/8" the outside diameter might be greater than .66". https://www.sizes.com/materials/pipeCopper.htm Also, Home Depot has valves with Shark Bite connectors which don't require compression fittings. Are those things reliable? |
#3
![]()
Posted to alt.home.repair
|
|||
|
|||
![]()
On 6/6/2021 8:47 PM, Nil wrote:
I need to replace a water shut-off valve below my kitchen sink. I see that valves come made to fit on either 1/2" or 5/8" pipe. When I measure the copper intake pipe with my (not very accurate) caliper it measures .66, which is a little over 5/8". I think I read somewhere that "1/2 inch" refers to the inside diameter, and that the outside diameter is closer to 5/8. True? No? So, what do I have, 1/2" or 5/8" copper pipe? I'm thinking 1/2" because it's more common, and if it were 5/8" the outside diameter might be greater than .66". Also, Home Depot has valves with Shark Bite connectors which don't require compression fittings. Are those things reliable? You have 1/2" copper 1/2 OD 0.625 ID 0.545 Sharkbite fittings work well. |
#4
![]()
Posted to alt.home.repair
|
|||
|
|||
![]()
On 06 Jun 2021, Dean Hoffman wrote in
alt.home.repair: On Sunday, June 6, 2021 at 7:47:57 PM UTC-5, Nil wrote: I need to replace a water shut-off valve below my kitchen sink. I see that valves come made to fit on either 1/2" or 5/8" pipe. When I measure the copper intake pipe with my (not very accurate) caliper it measures .66, which is a little over 5/8". I think I read somewhere that "1/2 inch" refers to the inside diameter, and that the outside diameter is closer to 5/8. True? No? So, what do I have, 1/2" or 5/8" copper pipe? I'm thinking 1/2" because it's more common, and if it were 5/8" the outside diameter might be greater than .66". https://www.sizes.com/materials/pipeCopper.htm Also, Home Depot has valves with Shark Bite connectors which don't require compression fittings. Are those things reliable? Good summary, thanks. Apparently I have 1/2" L-series pipe. |
#5
![]()
Posted to alt.home.repair
|
|||
|
|||
![]()
On 06 Jun 2021, Ed Pawlowski wrote in
alt.home.repair: On 6/6/2021 8:47 PM, Nil wrote: I need to replace a water shut-off valve below my kitchen sink. I see that valves come made to fit on either 1/2" or 5/8" pipe. When I measure the copper intake pipe with my (not very accurate) caliper it measures .66, which is a little over 5/8". I think I read somewhere that "1/2 inch" refers to the inside diameter, and that the outside diameter is closer to 5/8. True? No? So, what do I have, 1/2" or 5/8" copper pipe? I'm thinking 1/2" because it's more common, and if it were 5/8" the outside diameter might be greater than .66". Also, Home Depot has valves with Shark Bite connectors which don't require compression fittings. Are those things reliable? You have 1/2" copper 1/2 OD 0.625 ID 0.545 Sharkbite fittings work well. Thank you! I was going to buy two valves and return one, but I think you're right. The Sharkbite version will save me some work and uncertainty. I'm not good with those compression ring fittings. |
#6
![]()
Posted to alt.home.repair
|
|||
|
|||
![]()
On Sun, 06 Jun 2021 20:47:52 -0400, Nil
wrote: I need to replace a water shut-off valve below my kitchen sink. I see that valves come made to fit on either 1/2" or 5/8" pipe. When I measure the copper intake pipe with my (not very accurate) caliper it measures .66, which is a little over 5/8". I think I read somewhere that "1/2 inch" refers to the inside diameter, and that the outside diameter is closer to 5/8. True? No? So, what do I have, 1/2" or 5/8" copper pipe? I'm thinking 1/2" because it's more common, and if it were 5/8" the outside diameter might be greater than .66". Also, Home Depot has valves with Shark Bite connectors which don't require compression fittings. Are those things reliable? "Pipe" is specified by the nominal ID. (the OD remains the same for each nominal size) "Tubing" is measured by the OD fairly accurately. 1/2" copper PIPE is about 5/8 OD. The ID will vary by the "schedule/type" of the pipe. Thicker walls result in a smaller ID. The OD has to be the same so the fittings work. |
#7
![]()
Posted to alt.home.repair
|
|||
|
|||
![]() |
#8
![]()
Posted to alt.home.repair
|
|||
|
|||
![]() |
#9
![]()
Posted to alt.home.repair
|
|||
|
|||
![]() On Sun, 06 Jun 2021 20:47:52 -0400, Nil posted for all of us to digest... I need to replace a water shut-off valve below my kitchen sink. I see that valves come made to fit on either 1/2" or 5/8" pipe. When I measure the copper intake pipe with my (not very accurate) caliper it measures .66, which is a little over 5/8". I think I read somewhere that "1/2 inch" refers to the inside diameter, and that the outside diameter is closer to 5/8. True? No? So, what do I have, 1/2" or 5/8" copper pipe? I'm thinking 1/2" because it's more common, and if it were 5/8" the outside diameter might be greater than .66". Also, Home Depot has valves with Shark Bite connectors which don't require compression fittings. Are those things reliable? 1/2" No, IMO I don't like them. Do you store stuff in the cabinet? Does it ever slam against the pipes? Others may disagree. -- Tekkie |
#10
![]()
Posted to alt.home.repair
|
|||
|
|||
![]()
On Tuesday, June 8, 2021 at 2:33:43 PM UTC-4, wrote:
On Sun, 06 Jun 2021 20:47:52 -0400, Nil posted for all of us to digest... I need to replace a water shut-off valve below my kitchen sink. I see that valves come made to fit on either 1/2" or 5/8" pipe. When I measure the copper intake pipe with my (not very accurate) caliper it measures .66, which is a little over 5/8". I think I read somewhere that "1/2 inch" refers to the inside diameter, and that the outside diameter is closer to 5/8. True? No? So, what do I have, 1/2" or 5/8" copper pipe? I'm thinking 1/2" because it's more common, and if it were 5/8" the outside diameter might be greater than .66". Also, Home Depot has valves with Shark Bite connectors which don't require compression fittings. Are those things reliable? 1/2" No, IMO I don't like them. Do you store stuff in the cabinet? Does it ever slam against the pipes? Others may disagree. The question was not whether or not you like them, the question was "Are those things reliable?" The answer to that is Yes, otherwise they wouldn't be approved for behind the wall use by the Uniform Plumbing Code, the International Plumbing Code and the National Plumbing Code of Canada. In addition, the International Association of Plumbing and Mechanical Officials listing states that the product €ścan be utilized in underground applications and as manufactured joints without access panels.€ť That's good enough for me. Separate question: Are you OK with stuff banging against compression fittings but not push-to-fit fittings? If so, are you aware that SharkBite fittings are designed to rotate on the pipe while a compression fitting is fixed? Given the option, I'd rather have SharkBite fittings get knocked around than compression fittings. At least they are smart enough to get out of the way. ;-) |
#11
![]()
Posted to alt.home.repair
|
|||
|
|||
![]()
On 08 Jun 2021, Marilyn Manson wrote
in alt.home.repair: On Tuesday, June 8, 2021 at 2:33:43 PM UTC-4, wrote: 1/2" No, IMO I don't like them. Do you store stuff in the cabinet? Does it ever slam against the pipes? Others may disagree. The question was not whether or not you like them, the question was "Are those things reliable?" The answer to that is Yes, otherwise they wouldn't be approved for behind the wall use by the Uniform Plumbing Code, the International Plumbing Code and the National Plumbing Code of Canada. In addition, the International Association of Plumbing and Mechanical Officials listing states that the product €ścan be utilized in underground applications and as manufactured joints without access panels.€ť That's good enough for me. Separate question: Are you OK with stuff banging against compression fittings but not push-to-fit fittings? If so, are you aware that SharkBite fittings are designed to rotate on the pipe while a compression fitting is fixed? Given the option, I'd rather have SharkBite fittings get knocked around than compression fittings. At least they are smart enough to get out of the way. ;-) The cabinet has enough space in it that stuff doesn't usually knock against the pipes, although it could happen, of course. I didn't realize that the Sharkbite fittings were still rotatable after installation. I did notice in the one video I watched that it seemed to move a little, but I guess I figured that it would stay in place once everything was settled in. I kind of like the idea of the valve being firmly fixed in place, but in practice, once I install it it's not likely to move unless I'm turning the handle. |
#12
![]()
Posted to alt.home.repair
|
|||
|
|||
![]()
On Tue, 8 Jun 2021 13:05:35 -0700 (PDT), Marilyn Manson
wrote: On Tuesday, June 8, 2021 at 2:33:43 PM UTC-4, wrote: On Sun, 06 Jun 2021 20:47:52 -0400, Nil posted for all of us to digest... I need to replace a water shut-off valve below my kitchen sink. I see that valves come made to fit on either 1/2" or 5/8" pipe. When I measure the copper intake pipe with my (not very accurate) caliper it measures .66, which is a little over 5/8". I think I read somewhere that "1/2 inch" refers to the inside diameter, and that the outside diameter is closer to 5/8. True? No? So, what do I have, 1/2" or 5/8" copper pipe? I'm thinking 1/2" because it's more common, and if it were 5/8" the outside diameter might be greater than .66". Also, Home Depot has valves with Shark Bite connectors which don't require compression fittings. Are those things reliable? 1/2" No, IMO I don't like them. Do you store stuff in the cabinet? Does it ever slam against the pipes? Others may disagree. The question was not whether or not you like them, the question was "Are those things reliable?" The answer to that is Yes, otherwise they wouldn't be approved for behind the wall use by the Uniform Plumbing Code, the International Plumbing Code and the National Plumbing Code of Canada. In addition, the International Association of Plumbing and Mechanical Officials listing states that the product €ścan be utilized in underground applications and as manufactured joints without access panels.€ť That's good enough for me. Separate question: Are you OK with stuff banging against compression fittings but not push-to-fit fittings? If so, are you aware that SharkBite fittings are designed to rotate on the pipe while a compression fitting is fixed? Given the option, I'd rather have SharkBite fittings get knocked around than compression fittings. At least they are smart enough to get out of the way. ;-) Sharkbites are good as long as you expect to have an O ring last. If you have ever seen one get hard and brittle, think about that inside a wall. Just the fact that it is code legal doesn't really mean much. 1350 alloy Aluminum wire was legal in the wall for 30 years. Then it wasn't. |
#13
![]()
Posted to alt.home.repair
|
|||
|
|||
![]()
On Tuesday, June 8, 2021 at 6:19:19 PM UTC-4, wrote:
On Tue, 8 Jun 2021 13:05:35 -0700 (PDT), Marilyn Manson wrote: On Tuesday, June 8, 2021 at 2:33:43 PM UTC-4, wrote: On Sun, 06 Jun 2021 20:47:52 -0400, Nil posted for all of us to digest.... I need to replace a water shut-off valve below my kitchen sink. I see that valves come made to fit on either 1/2" or 5/8" pipe. When I measure the copper intake pipe with my (not very accurate) caliper it measures .66, which is a little over 5/8". I think I read somewhere that "1/2 inch" refers to the inside diameter, and that the outside diameter is closer to 5/8. True? No? So, what do I have, 1/2" or 5/8" copper pipe? I'm thinking 1/2" because it's more common, and if it were 5/8" the outside diameter might be greater than .66". Also, Home Depot has valves with Shark Bite connectors which don't require compression fittings. Are those things reliable? 1/2" No, IMO I don't like them. Do you store stuff in the cabinet? Does it ever slam against the pipes? Others may disagree. The question was not whether or not you like them, the question was "Are those things reliable?" The answer to that is Yes, otherwise they wouldn't be approved for behind the wall use by the Uniform Plumbing Code, the International Plumbing Code and the National Plumbing Code of Canada. In addition, the International Association of Plumbing and Mechanical Officials listing states that the product €ścan be utilized in underground applications and as manufactured joints without access panels.€ť That's good enough for me. Separate question: Are you OK with stuff banging against compression fittings but not push-to-fit fittings? If so, are you aware that SharkBite fittings are designed to rotate on the pipe while a compression fitting is fixed? Given the option, I'd rather have SharkBite fittings get knocked around than compression fittings. At least they are smart enough to get out of the way. ;-) Sharkbites are good as long as you expect to have an O ring last. If you have ever seen one get hard and brittle, think about that inside a wall. Just the fact that it is code legal doesn't really mean much. 1350 alloy Aluminum wire was legal in the wall for 30 years. Then it wasn't. Why was 1350 de-coded, so to speak? |
#14
![]()
Posted to alt.home.repair
|
|||
|
|||
![]()
On Tuesday, June 8, 2021 at 6:19:19 PM UTC-4, wrote:
On Tue, 8 Jun 2021 13:05:35 -0700 (PDT), Marilyn Manson wrote: On Tuesday, June 8, 2021 at 2:33:43 PM UTC-4, wrote: On Sun, 06 Jun 2021 20:47:52 -0400, Nil posted for all of us to digest.... I need to replace a water shut-off valve below my kitchen sink. I see that valves come made to fit on either 1/2" or 5/8" pipe. When I measure the copper intake pipe with my (not very accurate) caliper it measures .66, which is a little over 5/8". I think I read somewhere that "1/2 inch" refers to the inside diameter, and that the outside diameter is closer to 5/8. True? No? So, what do I have, 1/2" or 5/8" copper pipe? I'm thinking 1/2" because it's more common, and if it were 5/8" the outside diameter might be greater than .66". Also, Home Depot has valves with Shark Bite connectors which don't require compression fittings. Are those things reliable? 1/2" No, IMO I don't like them. Do you store stuff in the cabinet? Does it ever slam against the pipes? Others may disagree. The question was not whether or not you like them, the question was "Are those things reliable?" The answer to that is Yes, otherwise they wouldn't be approved for behind the wall use by the Uniform Plumbing Code, the International Plumbing Code and the National Plumbing Code of Canada. In addition, the International Association of Plumbing and Mechanical Officials listing states that the product €ścan be utilized in underground applications and as manufactured joints without access panels.€ť That's good enough for me. Separate question: Are you OK with stuff banging against compression fittings but not push-to-fit fittings? If so, are you aware that SharkBite fittings are designed to rotate on the pipe while a compression fitting is fixed? Given the option, I'd rather have SharkBite fittings get knocked around than compression fittings. At least they are smart enough to get out of the way. ;-) Sharkbites are good as long as you expect to have an O ring last. If you have ever seen one get hard and brittle, think about that inside a wall. Forgot to mention: Not all O-rings are created equal. Forgot to ask: What is your actual personal opinion of using SharkBite fittings inside a wall (or underground)? Just the fact that it is code legal doesn't really mean much. 1350 alloy Aluminum wire was legal in the wall for 30 years. Then it wasn't. |
#15
![]()
Posted to alt.home.repair
|
|||
|
|||
![]()
On Tuesday, June 8, 2021 at 6:17:06 PM UTC-4, Nil wrote:
On 08 Jun 2021, Marilyn Manson wrote in alt.home.repair: On Tuesday, June 8, 2021 at 2:33:43 PM UTC-4, wrote: 1/2" No, IMO I don't like them. Do you store stuff in the cabinet? Does it ever slam against the pipes? Others may disagree. The question was not whether or not you like them, the question was "Are those things reliable?" The answer to that is Yes, otherwise they wouldn't be approved for behind the wall use by the Uniform Plumbing Code, the International Plumbing Code and the National Plumbing Code of Canada. In addition, the International Association of Plumbing and Mechanical Officials listing states that the product €ścan be utilized in underground applications and as manufactured joints without access panels.€ť That's good enough for me. Separate question: Are you OK with stuff banging against compression fittings but not push-to-fit fittings? If so, are you aware that SharkBite fittings are designed to rotate on the pipe while a compression fitting is fixed? Given the option, I'd rather have SharkBite fittings get knocked around than compression fittings. At least they are smart enough to get out of the way. ;-) The cabinet has enough space in it that stuff doesn't usually knock against the pipes, although it could happen, of course. I didn't realize that the Sharkbite fittings were still rotatable after installation. I did notice in the one video I watched that it seemed to move a little, but I guess I figured that it would stay in place once everything was settled in. I kind of like the idea of the valve being firmly fixed in place, but in practice, once I install it it's not likely to move unless I'm turning the handle. The rotation of the fittings is actually a very convenient feature. There is no need to line up your elbows, tees, shutoffs, etc. during installation. Just pop them on and rotate them until they point in the direction that you need them to. Granted, they are more expensive, so I sweat where I can and use SharkBites mostly in tight spots, like inside a cabinet or up in a joist bay. I'd rather sweat than use compression fittings but if sweating is inconvenient, I'll use SharkBites without hesitation. |
#16
![]()
Posted to alt.home.repair
|
|||
|
|||
![]() |
#17
![]()
Posted to alt.home.repair
|
|||
|
|||
![]()
On Tue, 8 Jun 2021 15:59:48 -0700 (PDT), Marilyn Manson
wrote: On Tuesday, June 8, 2021 at 6:19:19 PM UTC-4, wrote: On Tue, 8 Jun 2021 13:05:35 -0700 (PDT), Marilyn Manson wrote: On Tuesday, June 8, 2021 at 2:33:43 PM UTC-4, wrote: On Sun, 06 Jun 2021 20:47:52 -0400, Nil posted for all of us to digest... I need to replace a water shut-off valve below my kitchen sink. I see that valves come made to fit on either 1/2" or 5/8" pipe. When I measure the copper intake pipe with my (not very accurate) caliper it measures .66, which is a little over 5/8". I think I read somewhere that "1/2 inch" refers to the inside diameter, and that the outside diameter is closer to 5/8. True? No? So, what do I have, 1/2" or 5/8" copper pipe? I'm thinking 1/2" because it's more common, and if it were 5/8" the outside diameter might be greater than .66". Also, Home Depot has valves with Shark Bite connectors which don't require compression fittings. Are those things reliable? 1/2" No, IMO I don't like them. Do you store stuff in the cabinet? Does it ever slam against the pipes? Others may disagree. The question was not whether or not you like them, the question was "Are those things reliable?" The answer to that is Yes, otherwise they wouldn't be approved for behind the wall use by the Uniform Plumbing Code, the International Plumbing Code and the National Plumbing Code of Canada. In addition, the International Association of Plumbing and Mechanical Officials listing states that the product €ścan be utilized in underground applications and as manufactured joints without access panels.€ť That's good enough for me. Separate question: Are you OK with stuff banging against compression fittings but not push-to-fit fittings? If so, are you aware that SharkBite fittings are designed to rotate on the pipe while a compression fitting is fixed? Given the option, I'd rather have SharkBite fittings get knocked around than compression fittings. At least they are smart enough to get out of the way. ;-) Sharkbites are good as long as you expect to have an O ring last. If you have ever seen one get hard and brittle, think about that inside a wall. Just the fact that it is code legal doesn't really mean much. 1350 alloy Aluminum wire was legal in the wall for 30 years. Then it wasn't. Why was 1350 de-coded, so to speak? That was the infamous "aluminum wire" that got so much scary press in the 70s. It was originally developed for overhead service, distribution and transmission. It turned out to have to much expansion and it was too brittle to use in small conductors. When they started using more malleable AA8800 alloys and devices that can deal with that expansion rate the code reflected that change (1975), in effect outlawing the 1350 wire. |
#18
![]()
Posted to alt.home.repair
|
|||
|
|||
![]()
On Tue, 8 Jun 2021 16:03:31 -0700 (PDT), Marilyn Manson
wrote: On Tuesday, June 8, 2021 at 6:19:19 PM UTC-4, wrote: On Tue, 8 Jun 2021 13:05:35 -0700 (PDT), Marilyn Manson wrote: On Tuesday, June 8, 2021 at 2:33:43 PM UTC-4, wrote: On Sun, 06 Jun 2021 20:47:52 -0400, Nil posted for all of us to digest... I need to replace a water shut-off valve below my kitchen sink. I see that valves come made to fit on either 1/2" or 5/8" pipe. When I measure the copper intake pipe with my (not very accurate) caliper it measures .66, which is a little over 5/8". I think I read somewhere that "1/2 inch" refers to the inside diameter, and that the outside diameter is closer to 5/8. True? No? So, what do I have, 1/2" or 5/8" copper pipe? I'm thinking 1/2" because it's more common, and if it were 5/8" the outside diameter might be greater than .66". Also, Home Depot has valves with Shark Bite connectors which don't require compression fittings. Are those things reliable? 1/2" No, IMO I don't like them. Do you store stuff in the cabinet? Does it ever slam against the pipes? Others may disagree. The question was not whether or not you like them, the question was "Are those things reliable?" The answer to that is Yes, otherwise they wouldn't be approved for behind the wall use by the Uniform Plumbing Code, the International Plumbing Code and the National Plumbing Code of Canada. In addition, the International Association of Plumbing and Mechanical Officials listing states that the product €ścan be utilized in underground applications and as manufactured joints without access panels.€ť That's good enough for me. Separate question: Are you OK with stuff banging against compression fittings but not push-to-fit fittings? If so, are you aware that SharkBite fittings are designed to rotate on the pipe while a compression fitting is fixed? Given the option, I'd rather have SharkBite fittings get knocked around than compression fittings. At least they are smart enough to get out of the way. ;-) Sharkbites are good as long as you expect to have an O ring last. If you have ever seen one get hard and brittle, think about that inside a wall. Forgot to mention: Not all O-rings are created equal. It is still an O ring. You better be sure there are no burrs on the pipe. These things remind me of Polybutylene pipe. That was all the rage, legal, easy to use and fast to install, until it started failing. Forgot to ask: What is your actual personal opinion of using SharkBite fittings inside a wall (or underground)? I wouldn't use them at all. I know how to sweat pipe. If I couldn't use a torch (fire hazard), I would use a compression fitting or a flare. Just the fact that it is code legal doesn't really mean much. 1350 alloy Aluminum wire was legal in the wall for 30 years. Then it wasn't. |
#19
![]()
Posted to alt.home.repair
|
|||
|
|||
![]()
On 08 Jun 2021, Marilyn Manson wrote
in alt.home.repair: The rotation of the fittings is actually a very convenient feature. There is no need to line up your elbows, tees, shutoffs, etc. during installation. Just pop them on and rotate them until they point in the direction that you need them to. Granted, they are more expensive, so I sweat where I can and use SharkBites mostly in tight spots, like inside a cabinet or up in a joist bay. I'd rather sweat than use compression fittings but if sweating is inconvenient, I'll use SharkBites without hesitation. It is super-cramped in this cabinet. I can't really fit my shoulders in there, which leaves me trying to do the work with arms fully extended. Very uncomfortable and fatiguing. I assume that most of the plumbing was done before they installed the cabinetry. I think Sharkbites will make the job a hell of a lot easier and faster. |
#20
![]()
Posted to alt.home.repair
|
|||
|
|||
![]()
On Tue, 8 Jun 2021 19:35:54 -0400, Ralph Mowery
wrote: In article , says... wall. Just the fact that it is code legal doesn't really mean much. 1350 alloy Aluminum wire was legal in the wall for 30 years. Then it wasn't. Why was 1350 de-coded, so to speak? From what I understand many houses were set on fire by it. The stuff has a habit of loosing up under the screws and creating hot spots. The number of actual fires that burned houses down was pretty low but the system worked in the sense that there were plenty of scary looking receptacle "close calls" where there was a fire but it was mostly contained by the box. There is still an argument that workmanship was as big a contributor as the wire itself but it was clear a steel binding screw had different thermal characteristics than aluminum wire. This is certainly not a wiring method for Harry Homeowner to be screwing with if they don't understand the issues. The Co/Alr device specified in the 75 and up code uses a different alloy screw that tracks the aluminum better. The head is bigger to accommodate the larger wire size and most have serration to give the wire a better grip. By the time they fixed the problem, aluminum had such a bad reputation it never caught on again. There never was a problem with lug type terminations see on larger wire sizes and on most large devices the lug is aluminum anyway. Studies have shown aluminum wire in an aluminum lug performs better than copper but not enough to be significant. The studies also show, anti-oxidant paste doesn't really do much but it makes people feel better. The code only requires it if the manufacturer has it in their "requirements" (not recommendations) so it really isn't going to be required very often. I still know 2 people with aluminum wired houses that are not having problems 50 years later. Their secret, it was installed well and nobody screwed with it. |
#21
![]()
Posted to alt.home.repair
|
|||
|
|||
![]()
On Tuesday, June 8, 2021 at 7:46:36 PM UTC-4, wrote:
On Tue, 8 Jun 2021 16:03:31 -0700 (PDT), Marilyn Manson wrote: On Tuesday, June 8, 2021 at 6:19:19 PM UTC-4, wrote: On Tue, 8 Jun 2021 13:05:35 -0700 (PDT), Marilyn Manson wrote: On Tuesday, June 8, 2021 at 2:33:43 PM UTC-4, wrote: On Sun, 06 Jun 2021 20:47:52 -0400, Nil posted for all of us to digest... I need to replace a water shut-off valve below my kitchen sink. I see that valves come made to fit on either 1/2" or 5/8" pipe. When I measure the copper intake pipe with my (not very accurate) caliper it measures .66, which is a little over 5/8". I think I read somewhere that "1/2 inch" refers to the inside diameter, and that the outside diameter is closer to 5/8. True? No? So, what do I have, 1/2" or 5/8" copper pipe? I'm thinking 1/2" because it's more common, and if it were 5/8" the outside diameter might be greater than .66". Also, Home Depot has valves with Shark Bite connectors which don't require compression fittings. Are those things reliable? 1/2" No, IMO I don't like them. Do you store stuff in the cabinet? Does it ever slam against the pipes? Others may disagree. The question was not whether or not you like them, the question was "Are those things reliable?" The answer to that is Yes, otherwise they wouldn't be approved for behind the wall use by the Uniform Plumbing Code, the International Plumbing Code and the National Plumbing Code of Canada. In addition, the International Association of Plumbing and Mechanical Officials listing states that the product €ścan be utilized in underground applications and as manufactured joints without access panels.€ť That's good enough for me. Separate question: Are you OK with stuff banging against compression fittings but not push-to-fit fittings? If so, are you aware that SharkBite fittings are designed to rotate on the pipe while a compression fitting is fixed? Given the option, I'd rather have SharkBite fittings get knocked around than compression fittings. At least they are smart enough to get out of the way. ;-) Sharkbites are good as long as you expect to have an O ring last. If you have ever seen one get hard and brittle, think about that inside a wall. Forgot to mention: Not all O-rings are created equal. It is still an O ring. You better be sure there are no burrs on the pipe. These things remind me of Polybutylene pipe. That was all the rage, legal, easy to use and fast to install, until it started failing. Forgot to ask: What is your actual personal opinion of using SharkBite fittings inside a wall (or underground)? I wouldn't use them at all. I know how to sweat pipe. Pretty much agree. I would only use a SB for a tough location, where soldering was too difficult or risky. So far I haven't encountered that scenario. |
#22
![]()
Posted to alt.home.repair
|
|||
|
|||
![]()
On Wednesday, June 9, 2021 at 9:20:13 AM UTC-4, trader_4 wrote:
On Tuesday, June 8, 2021 at 7:46:36 PM UTC-4, wrote: On Tue, 8 Jun 2021 16:03:31 -0700 (PDT), Marilyn Manson wrote: On Tuesday, June 8, 2021 at 6:19:19 PM UTC-4, wrote: On Tue, 8 Jun 2021 13:05:35 -0700 (PDT), Marilyn Manson wrote: On Tuesday, June 8, 2021 at 2:33:43 PM UTC-4, wrote: On Sun, 06 Jun 2021 20:47:52 -0400, Nil posted for all of us to digest... I need to replace a water shut-off valve below my kitchen sink. I see that valves come made to fit on either 1/2" or 5/8" pipe. When I measure the copper intake pipe with my (not very accurate) caliper it measures .66, which is a little over 5/8". I think I read somewhere that "1/2 inch" refers to the inside diameter, and that the outside diameter is closer to 5/8. True? No? So, what do I have, 1/2" or 5/8" copper pipe? I'm thinking 1/2" because it's more common, and if it were 5/8" the outside diameter might be greater than .66". Also, Home Depot has valves with Shark Bite connectors which don't require compression fittings. Are those things reliable? 1/2" No, IMO I don't like them. Do you store stuff in the cabinet? Does it ever slam against the pipes? Others may disagree. The question was not whether or not you like them, the question was "Are those things reliable?" The answer to that is Yes, otherwise they wouldn't be approved for behind the wall use by the Uniform Plumbing Code, the International Plumbing Code and the National Plumbing Code of Canada. In addition, the International Association of Plumbing and Mechanical Officials listing states that the product €ścan be utilized in underground applications and as manufactured joints without access panels.€ť That's good enough for me. Separate question: Are you OK with stuff banging against compression fittings but not push-to-fit fittings? If so, are you aware that SharkBite fittings are designed to rotate on the pipe while a compression fitting is fixed? Given the option, I'd rather have SharkBite fittings get knocked around than compression fittings. At least they are smart enough to get out of the way. ;-) Sharkbites are good as long as you expect to have an O ring last. If you have ever seen one get hard and brittle, think about that inside a wall. Forgot to mention: Not all O-rings are created equal. It is still an O ring. You better be sure there are no burrs on the pipe. These things remind me of Polybutylene pipe. That was all the rage, legal, easy to use and fast to install, until it started failing. Forgot to ask: What is your actual personal opinion of using SharkBite fittings inside a wall (or underground)? I wouldn't use them at all. I know how to sweat pipe. Pretty much agree. I would only use a SB for a tough location, where soldering was too difficult or risky. So far I haven't encountered that scenario. That's basically where I am at and where I have used them. I recently did some reno work in bathroom that involved removing the sink. It turned out that the 30+ YO compression shut-offs didn't hold. I have a couple of SharkBite caps, so I turned off the main, removed the old compression shutoffs, popped on the caps and turned the main back on. 10 minutes worth of work. I bought new compression shutoffs but for the life of me I could not get them to stop leaking. I tried 3 and they all leaked. 2 SharkBite shutoffs later and I was good to go. Shutoffs are too close to a finished wall to sweat. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Moving Tree Journeyman Mill - sanity check | Metalworking | |||
sanity check, please | Woodworking | |||
Sanity-check on gearing question, please? | Metalworking | |||
Wetroom Electrics Sanity Check Please! | UK diy | |||
Water softener and iron filter sanity check | Home Ownership |