Im the one who mentioned the circuit breaker keeps tripping when the AC
comes on. Finally got the technician to come out and check it. He did some continuity checks and then we tried to turn on the breaker. There were sparks around the terminals of the compressor. He says its shorted which makes sense. I have a Ruud 10 SEER System with R-22 freon. He says you cant get replacements and must switch to R-410a systems. The coil in the furnace must also be replaced to match the pressure of the outside unit. He estimated total cost close to $6000 installed for a 14 SEER Rheem compressor/coil. The boss will call tomorrow with the price. Ive dealt with these people before. Theyve replaced my water heater and done some other plumbing jobs so I trust them. Does this seem like a reasonable diagnosis and cost? I live in SE Virginia. |
#2
Posted to alt.home.repair
|
|||
|
|||
compressor shot
|
#3
Posted to alt.home.repair
|
|||
|
|||
compressor shot
On Thursday, February 22, 2018 at 5:06:44 PM UTC-5, badgolferman wrote:
Im the one who mentioned the circuit breaker keeps tripping when the AC comes on. Finally got the technician to come out and check it. He did some continuity checks and then we tried to turn on the breaker. There were sparks around the terminals of the compressor. He says its shorted which makes sense. I have a Ruud 10 SEER System with R-22 freon. He says you cant get replacements and must switch to R-410a systems. The coil in the furnace must also be replaced to match the pressure of the outside unit. He estimated total cost close to $6000 installed for a 14 SEER Rheem compressor/coil. The boss will call tomorrow with the price. Ive dealt with these people before. Theyve replaced my water heater and done some other plumbing jobs so I trust them. Does this seem like a reasonable diagnosis and cost? I live in SE Virginia. Sounds high to me. How many tons? New lines or reuse the old? Permits included? You can buy that eqpt, 3 ton for under $2k. And how old is the furnace? That costs under $2k too and some of the labor is the same, if it's 15+ old and/or lower efficiency, I'd consider a whole system. And if it were me, I'd pay a little more more for a two stage ac, it's great for days when you just want to drop the humidity or cool it off a little. |
#4
Posted to alt.home.repair
|
|||
|
|||
compressor shot
On Thu, 22 Feb 2018 18:51:47 -0500, Ralph Mowery
wrote: In article , says... I?m the one who mentioned the circuit breaker keeps tripping when the AC comes on. Finally got the technician to come out and check it. He did some continuity checks and then we tried to turn on the breaker. There were sparks around the terminals of the compressor. He says it?s shorted which makes sense. I have a Ruud 10 SEER System with R-22 freon. He says you can?t get replacements and must switch to R-410a systems. The coil in the furnace must also be replaced to match the pressure of the outside unit. He estimated total cost close to $6000 installed for a 14 SEER Rheem compressor/coil. The boss will call tomorrow with the price. I?ve dealt with these people before. They?ve replaced my water heater and done some other plumbing jobs so I trust them. Does this seem like a reasonable diagnosis and cost? I live in SE Virginia. Sounds about right to me. The new r-22 systems have not been legal in the US for probably over 10 years. Study says r-22 is bad for the ozone. My info is the patten ranout on it about the same time. The newer systems run at different pressuers and every thing needs to match. If the system is old enough to be a r-22 it is probably old enough to be replaced. I had a heat pump replaced about 10 years ago and think it was around 4000 to 5000 for it. At that time I had a r-22 system put in as I could still get it. "Did it for several reasons. I had a tank of r-22 if I needed to add to it, the r-22 system has been around a long time, and the pressure is less so should be less wear on the system. You can;t buy new R22 systems, but you can still legally buy replacement parts. If the rest of the systemis still in good condition, replacing thecompressor would be "significantly" less expensive as long as R22 is still available. |
#5
Posted to alt.home.repair
|
|||
|
|||
compressor shot
"badgolferman" wrote in message news I'm the one who mentioned the circuit breaker keeps tripping when the AC comes on. Finally got the technician to come out and check it. He did some continuity checks and then we tried to turn on the breaker. There were sparks around the terminals of the compressor. He says it's shorted which makes sense. I have a Ruud 10 SEER System with R-22 freon. He says you can't get replacements and must switch to R-410a systems. The coil in the furnace must also be replaced to match the pressure of the outside unit. He estimated total cost close to $6000 installed for a 14 SEER Rheem compressor/coil. The boss will call tomorrow with the price. I've dealt with these people before. They've replaced my water heater and done some other plumbing jobs so I trust them. Does this seem like a reasonable diagnosis and cost? I live in SE Virginia. Get two other quotes and you will have your answer. |
#6
Posted to alt.home.repair
|
|||
|
|||
compressor shot
On Thursday, February 22, 2018 at 9:00:11 PM UTC-5, Clare Snyder wrote:
On Thu, 22 Feb 2018 18:51:47 -0500, Ralph Mowery wrote: In article , says... I?m the one who mentioned the circuit breaker keeps tripping when the AC comes on. Finally got the technician to come out and check it. He did some continuity checks and then we tried to turn on the breaker. There were sparks around the terminals of the compressor. He says it?s shorted which makes sense. I have a Ruud 10 SEER System with R-22 freon. He says you can?t get replacements and must switch to R-410a systems. The coil in the furnace must also be replaced to match the pressure of the outside unit. He estimated total cost close to $6000 installed for a 14 SEER Rheem compressor/coil. The boss will call tomorrow with the price. I?ve dealt with these people before. They?ve replaced my water heater and done some other plumbing jobs so I trust them. Does this seem like a reasonable diagnosis and cost? I live in SE Virginia. Sounds about right to me. The new r-22 systems have not been legal in the US for probably over 10 years. Study says r-22 is bad for the ozone. My info is the patten ranout on it about the same time. The newer systems run at different pressuers and every thing needs to match. If the system is old enough to be a r-22 it is probably old enough to be replaced. I had a heat pump replaced about 10 years ago and think it was around 4000 to 5000 for it. At that time I had a r-22 system put in as I could still get it. "Did it for several reasons. I had a tank of r-22 if I needed to add to it, the r-22 system has been around a long time, and the pressure is less so should be less wear on the system. You can;t buy new R22 systems, but you can still legally buy replacement parts. If the rest of the systemis still in good condition, replacing thecompressor would be "significantly" less expensive as long as R22 is still available. True, but he should also factor in how much it runs and what it costs to run. When I replaced my old AC which was probably rated 10 Seer with a 14, my electric bills in summer went down ~$200 a month and I'm in a shady spot and keep it at 76F. Probably because if it was once 10 Seer, it was probably less at the end of it's life. Also he should look into any rebates from the local utility, state, etc. Installers should be aware and have told him, but you never know. |
#7
Posted to alt.home.repair
|
|||
|
|||
compressor shot
On 02/22/2018 06:10 PM, trader_4 wrote:
[snip] Sounds high to me. How many tons? New lines or reuse the old? Permits included? You can buy that eqpt, 3 ton for under $2k. And how old is the furnace? That costs under $2k too and some of the labor is the same, if it's 15+ old and/or lower efficiency, I'd consider a whole system. And if it were me, I'd pay a little more more for a two stage ac, it's great for days when you just want to drop the humidity or cool it off a little. I got my system replaced about 4 years ago for a little over $7000. 3-ton A/C, new lineset, gas furnace, and thermostat. both A/C and furnace are 2 stage. BTW, the new furnace has a small fan in the exhaust. -- Mark Lloyd http://notstupid.us/ "It is not disbelief that is dangerous to our society; it is belief." [George Bernard Shaw] |
#8
Posted to alt.home.repair
|
|||
|
|||
compressor shot
badgolferman wrote:
Im the one who mentioned the circuit breaker keeps tripping when the AC comes on. Finally got the technician to come out and check it. He did some continuity checks and then we tried to turn on the breaker. There were sparks around the terminals of the compressor. He says its shorted which makes sense. I have a Ruud 10 SEER System with R-22 freon. He says you cant get replacements and must switch to R-410a systems. The coil in the furnace must also be replaced to match the pressure of the outside unit. He estimated total cost close to $6000 installed for a 14 SEER Rheem compressor/coil. The boss will call tomorrow with the price. Ive dealt with these people before. Theyve replaced my water heater and done some other plumbing jobs so I trust them. Does this seem like a reasonable diagnosis and cost? I live in SE Virginia. First quote is $5400. Waiting for two more to come through. I've asked for the furnace estimate too but that's not part of the first quote. I am planning on selling in 4-5 years. New water heater, furnace/AC may be a good selling point. |
#9
Posted to alt.home.repair
|
|||
|
|||
compressor shot
On Friday, February 23, 2018 at 12:24:11 PM UTC-5, Mark Lloyd wrote:
On 02/22/2018 06:10 PM, trader_4 wrote: [snip] Sounds high to me. How many tons? New lines or reuse the old? Permits included? You can buy that eqpt, 3 ton for under $2k. And how old is the furnace? That costs under $2k too and some of the labor is the same, if it's 15+ old and/or lower efficiency, I'd consider a whole system. And if it were me, I'd pay a little more more for a two stage ac, it's great for days when you just want to drop the humidity or cool it off a little. I got my system replaced about 4 years ago for a little over $7000. 3-ton A/C, new lineset, gas furnace, and thermostat. both A/C and furnace are 2 stage. BTW, the new furnace has a small fan in the exhaust. -- Mark Lloyd http://notstupid.us/ "It is not disbelief that is dangerous to our society; it is belief." [George Bernard Shaw] $7K for a whole 2 stage system, including furnace sounds like a good deal. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
OT(ish) 12V compressor vs. 240V compressor for tyres | UK diy | |||
Wow, this guy looks like Bush in a face shot and Schwarzenegger inprofile shot | Metalworking | |||
is a 2 tank compressor better than a 1 tank compressor? | Home Repair | |||
Long Shot. Need help with "Cabinet Vision Solid" software. | Woodworking | |||
sony cyber-shot dsc-s30 problem | Electronics Repair |