I have a gas pool heater that has a 1/4"-18 NPT brass plug
that goes into a cast iron manifold. Over time the threads in the cast iron have deteriorated and now I can't get the plug in. I tried a new plug and one of the other plugs from another location. I checked to see if there is a helicoil for npt and they have it. I'm not sure how the helicoil works for a pipe fitting so that it doesn't leak, but I guess it must work. Problem is that so far, I can only find the insert in packs of 12 for $25, the tap is $45. Then I think you need an insertion tool? So, any other ideas? It doesn't have to be the most 100% reliable solution, ie if it drips a bit or fails, it's not the end of the world. Also, I'm not even using the pool heater, but I'm not keen on ripping it out either. The area of the plug just has warm water going through it, not super hot. So, I'm thinking to just epoxy it closed. In the Fall to winterize it I can just knock it out. Any other ideas? |
#2
Posted to alt.home.repair
|
|||
|
|||
Helicoil or other ideas for 1/4" pipe threads?
|
#3
Posted to alt.home.repair
|
|||
|
|||
Helicoil or other ideas for 1/4" pipe threads?
On Jun 9, 8:48*pm, RBM wrote:
On 6/9/2013 8:43 PM, wrote: I have a gas pool heater that has a 1/4"-18 NPT brass plug that goes into a cast iron manifold. *Over time the threads in the cast iron have deteriorated and now I can't get the plug in. *I tried a new plug and one of the other plugs from another location. I checked to see if there is a helicoil for npt and they have it. I'm not sure how the helicoil works for a pipe fitting so that it doesn't leak, but I guess it must work. *Problem is that so far, I can only find the insert in packs of 12 for $25, the tap is $45. Then I think you need an insertion tool? So, any other ideas? * It doesn't have to be the most 100% reliable solution, ie if it drips a bit or fails, it's not the end of the world. * Also, I'm not even using the pool heater, but I'm not keen on ripping it out either. * The area of the plug just has warm water going through it, not super hot. *So, I'm thinking to just epoxy it closed. *In the Fall to winterize it I can just knock it out. * Any other ideas? can you get a tap and just try chasing the threads?- Hide quoted text - - Show quoted text - Yes, that is a good idea. I had thought of doing that, but I didn't have all my tools available here. And then I guess I got so excited by A - finding out they they do make a helicoil for npt B - finding out how much it costs! that I forgot about just trying a tap. I'm going to see if I have a 1/4" tap tomorrow. Thanks Even if I don't I can probably get a standard one cheap enough. |
#4
Posted to alt.home.repair
|
|||
|
|||
Helicoil or other ideas for 1/4" pipe threads?
|
#5
Posted to alt.home.repair
|
|||
|
|||
Helicoil or other ideas for 1/4" pipe threads?
|
#6
Posted to alt.home.repair
|
|||
|
|||
Helicoil or other ideas for 1/4" pipe threads?
|
#7
|
|||
|
|||
I'd clean the theads with a 1/4 inch NPT tap and then screw a 1/4 inch NPT nipple (with plenty of teflon tape on it) and a 1/4 inch NPT ball valve into what you have.
From then on, you can simply connect to the brand new brass treads on the 1/4 inch ball valve. And, if those threads eventually wear out in time, just replace the 1/4 inch ball valve with a new one. You should not have any problem finding 1/4 inch ball valves. I installed 1/8 inch ball valves on the NPT threads in my upstairs laundry room radiators. I purchased those 1/8 inch ball valves from my local Fairview Fittings distributor. If you look under "Hoses and Fittings" in your local yellow pages phone directory, at least one of the companies listed there will stock and sell you a 1/4 inch ball valve. Every plumbing wholesaler in our city or town will sell you a 1/4 inch ball valve if you pay cash too. |
#8
Posted to alt.home.repair
|
|||
|
|||
Helicoil or other ideas for 1/4" pipe threads?
On Jun 10, 6:20*am, nestork wrote:
I'd clean the theads with a 1/4 inch NPT tap and then screw a 1/4 inch NPT nipple (with plenty of teflon tape on it) and a 1/4 inch NPT ball valve into what you have. From then on, you can simply connect to the brand new brass treads on the 1/4 inch ball valve. *And, if those threads eventually wear out in time, just replace the 1/4 inch ball valve with a new one. You should not have any problem finding 1/4 inch ball valves. *I installed 1/8 inch ball valves on the NPT threads in my upstairs laundry room radiators. *I purchased those 1/8 inch ball valves from my local Fairview Fittings distributor. *If you look under "Hoses and Fittings" in your local yellow pages phone directory, at least one of the companies listed there will stock and sell you a 1/4 inch ball valve. Every plumbing wholesaler in our city or town will sell you a 1/4 inch ball valve if you pay cash too. -- nestork I was thinking along similar lines, ie using a nipple and a cap, so that if I get this straightened out, I won't have to screw with the cast iron part again. You would think by now they would have a pool heater design where you could drain it through one brass valve they could put at the low spot. Failing that, doing something like what you suggest on each drain, so that instead of screwing around with anything that is cast iron, it would be only brass to brass. The way it exists now, there are three 1/4" brass/bronze plugs going into cast iron. |
#10
Posted to alt.home.repair
|
|||
|
|||
Helicoil or other ideas for 1/4" pipe threads?
On Jun 10, 11:31*am, wrote:
On Mon, 10 Jun 2013 11:23:25 -0400, wrote: On Sun, 09 Jun 2013 20:48:04 -0400, RBM wrote: On 6/9/2013 8:43 PM, wrote: I have a gas pool heater that has a 1/4"-18 NPT brass plug that goes into a cast iron manifold. *Over time the threads in the cast iron have deteriorated and now I can't get the plug in. *I tried a new plug and one of the other plugs from another location. I checked to see if there is a helicoil for npt and they have it. I'm not sure how the helicoil works for a pipe fitting so that it doesn't leak, but I guess it must work. *Problem is that so far, I can only find the insert in packs of 12 for $25, the tap is $45. Then I think you need an insertion tool? So, any other ideas? * It doesn't have to be the most 100% reliable solution, ie if it drips a bit or fails, it's not the end of the world. * Also, I'm not even using the pool heater, but I'm not keen on ripping it out either. * The area of the plug just has warm water going through it, not super hot. *So, I'm thinking to just epoxy it closed. *In the Fall to winterize it I can just knock it out. * Any other ideas? can you get a tap and just try chasing the threads? And if the threads are too far gone, drill it out and tap to 3/8 npt and install a reducer bushing. I suppose if you don't want to invest in any taps, you could epoxy a 1/4" pipe nipple in there and put a cap on it.- Hide quoted text - - Show quoted text - I checked and I don't have a tap. But buying a regular tap isn't a problem. So, that's the plan of record right now, try using a 1/4" tap to restore the threads. If it works, I'll put in a nipple so I won;t have to screw around with that connection again. |
#11
Posted to alt.home.repair
|
|||
|
|||
Helicoil or other ideas for 1/4" pipe threads?
RBM wrote: On 6/9/2013 8:43 PM, wrote: I have a gas pool heater that has a 1/4"-18 NPT brass plug that goes into a cast iron manifold. Over time the threads in the cast iron have deteriorated and now I can't get the plug in. I tried a new plug and one of the other plugs from another location. I checked to see if there is a helicoil for npt and they have it. I'm not sure how the helicoil works for a pipe fitting so that it doesn't leak, but I guess it must work. Problem is that so far, I can only find the insert in packs of 12 for $25, the tap is $45. Then I think you need an insertion tool? So, any other ideas? It doesn't have to be the most 100% reliable solution, ie if it drips a bit or fails, it's not the end of the world. Also, I'm not even using the pool heater, but I'm not keen on ripping it out either. The area of the plug just has warm water going through it, not super hot. So, I'm thinking to just epoxy it closed. In the Fall to winterize it I can just knock it out. Any other ideas? can you get a tap and just try chasing the threads? A helicoil relies on re-drilling and re-tapping to a larger size. Can you simply re-drill and re-tap to 3/8" NPT and use a 3/8" NPT plug? That would require only ordinary drills and taps that are cheap and available singly, and of course a new plug. |
#12
Posted to alt.home.repair
|
|||
|
|||
Helicoil or other ideas for 1/4" pipe threads?
On Sunday, June 9, 2013 8:43:05 PM UTC-4, wrote:
Any other ideas? The cost of the helicoil certainly has to exceed the cost of a new manifold. I know you're "not keen" on fixing it right, but this might be a good time to reconsider that solution as a possibility. |
#13
Posted to alt.home.repair
|
|||
|
|||
Helicoil or other ideas for 1/4" pipe threads?
On Sunday, June 9, 2013 8:43:05 PM UTC-4, wrote:
I have a gas pool heater that has a 1/4"-18 NPT brass plug that goes into a cast iron manifold. Over time the threads in the cast iron have deteriorated and now I can't get the plug in. I tried a new plug and one of the other plugs from another location. I checked to see if there is a helicoil for npt and they have it. I'm not sure how the helicoil works for a pipe fitting so that it doesn't leak, but I guess it must work. Problem is that so far, I can only find the insert in packs of 12 for $25, the tap is $45. Then I think you need an insertion tool? So, any other ideas? It doesn't have to be the most 100% reliable solution, ie if it drips a bit or fails, it's not the end of the world. Also, I'm not even using the pool heater, but I'm not keen on ripping it out either. The area of the plug just has warm water going through it, not super hot. So, I'm thinking to just epoxy it closed. In the Fall to winterize it I can just knock it out. Any other ideas? Chasing with a tap has almost always fixed my problems with corroded female pipe thread. That and a little extra teflon tape. The yellow tape for gas is a lot thicker. |
#14
Posted to alt.home.repair
|
|||
|
|||
Helicoil or other ideas for 1/4" pipe threads?
|
#15
|
|||
|
|||
Yet another idea...
I know that it wasn't possible to weld cast iron years ago, but they're doing it now in cylinder and engine block rebuilding shops. Maybe you could take that manifold to a cylinder head rebuilding shop and have them weld a 1/4 inch steel nipple into the threaded opening you're having difficulty with. The wall thickness of the nipple might be too thin for welding, but I expect you can get 1/4 inch nipples in Schedule 80 and 120 for greater wall thicknesses if you special order them. |
#16
Posted to alt.home.repair
|
|||
|
|||
Helicoil or other ideas for 1/4" pipe threads?
On Jun 10, 3:22*pm, "Pete C." wrote:
RBM wrote: On 6/9/2013 8:43 PM, wrote: I have a gas pool heater that has a 1/4"-18 NPT brass plug that goes into a cast iron manifold. *Over time the threads in the cast iron have deteriorated and now I can't get the plug in. *I tried a new plug and one of the other plugs from another location. I checked to see if there is a helicoil for npt and they have it. I'm not sure how the helicoil works for a pipe fitting so that it doesn't leak, but I guess it must work. *Problem is that so far, I can only find the insert in packs of 12 for $25, the tap is $45. Then I think you need an insertion tool? So, any other ideas? * It doesn't have to be the most 100% reliable solution, ie if it drips a bit or fails, it's not the end of the world. * Also, I'm not even using the pool heater, but I'm not keen on ripping it out either. * The area of the plug just has warm water going through it, not super hot. *So, I'm thinking to just epoxy it closed. *In the Fall to winterize it I can just knock it out. * Any other ideas? can you get a tap and just try chasing the threads? A helicoil relies on re-drilling and re-tapping to a larger size. Can you simply re-drill and re-tap to 3/8" NPT and use a 3/8" NPT plug? That would require only ordinary drills and taps that are cheap and available singly, and of course a new plug.- Hide quoted text - - Show quoted text - That's a good point too. You're right. If you have to drill it for a helicoil, might as well just re-tap it to 3/8". I've never tapped cast iron, but I guess it can be done, as the threads got there somehow to begin with. So, first plan is to try running a 1/4" tap through it to clean up the threads. I found a tap yesterday, that wasn't easy. HD had some tap, but no NPT. Lowes had no taps at all. Tried Autozone parts store, I figured they probably would not have NPT either. Not only didn't they have any NPT, they hardly had any taps at all! But the Autozone guy suggested trying a old hardware store just up the street. I didn't even know that store existed. It looked like it was out of the 60's. But the guy was sitting there, waiting for me. Told him what I wanted, he walked behind the counter and in 30 secs I had it for $8. So, I'll let you know how I make out.... |
#17
Posted to alt.home.repair
|
|||
|
|||
Helicoil or other ideas for 1/4" pipe threads?
On Jun 11, 8:22*am, "
wrote: On Jun 10, 3:22*pm, "Pete C." wrote: RBM wrote: On 6/9/2013 8:43 PM, wrote: I have a gas pool heater that has a 1/4"-18 NPT brass plug that goes into a cast iron manifold. *Over time the threads in the cast iron have deteriorated and now I can't get the plug in. *I tried a new plug and one of the other plugs from another location. I checked to see if there is a helicoil for npt and they have it. I'm not sure how the helicoil works for a pipe fitting so that it doesn't leak, but I guess it must work. *Problem is that so far, I can only find the insert in packs of 12 for $25, the tap is $45. Then I think you need an insertion tool? So, any other ideas? * It doesn't have to be the most 100% reliable solution, ie if it drips a bit or fails, it's not the end of the world. * Also, I'm not even using the pool heater, but I'm not keen on ripping it out either. * The area of the plug just has warm water going through it, not super hot. *So, I'm thinking to just epoxy it closed. *In the Fall to winterize it I can just knock it out. * Any other ideas? can you get a tap and just try chasing the threads? A helicoil relies on re-drilling and re-tapping to a larger size. Can you simply re-drill and re-tap to 3/8" NPT and use a 3/8" NPT plug? That would require only ordinary drills and taps that are cheap and available singly, and of course a new plug.- Hide quoted text - - Show quoted text - That's a good point too. *You're right. *If you have to drill it for a helicoil, might as well just re-tap it to 3/8". *I've never tapped cast iron, but I guess it can be done, as the threads got there somehow to begin with. So, first plan is to try running a 1/4" tap through it to clean up the threads. *I found a tap yesterday, that wasn't easy. *HD had some tap, but no NPT. *Lowes had no taps at all. *Tried Autozone parts store, I figured they probably would not have NPT either. *Not only didn't they have any NPT, they hardly had any taps at all! But the Autozone guy suggested trying a old hardware store just up the street. *I didn't even know that store existed. *It looked like it was out of the 60's. * But the guy was sitting there, waiting for me. *Told him what I wanted, he walked behind the counter and in 30 secs I had it for $8. So, I'll let you know how I make out....- Hide quoted text - - Show quoted text - Oh, and forgot to mention. I also got a short brass nipple and a valve, per nestork's suggestion. Assuming I get it back together, I won't have to take it apart again. |
#18
Posted to alt.home.repair
|
|||
|
|||
Helicoil or other ideas for 1/4" pipe threads?
On Jun 11, 8:24*am, "
wrote: On Jun 11, 8:22*am, " wrote: On Jun 10, 3:22*pm, "Pete C." wrote: RBM wrote: On 6/9/2013 8:43 PM, wrote: I have a gas pool heater that has a 1/4"-18 NPT brass plug that goes into a cast iron manifold. *Over time the threads in the cast iron have deteriorated and now I can't get the plug in. *I tried a new plug and one of the other plugs from another location. I checked to see if there is a helicoil for npt and they have it. I'm not sure how the helicoil works for a pipe fitting so that it doesn't leak, but I guess it must work. *Problem is that so far, I can only find the insert in packs of 12 for $25, the tap is $45.. Then I think you need an insertion tool? So, any other ideas? * It doesn't have to be the most 100% reliable solution, ie if it drips a bit or fails, it's not the end of the world. * Also, I'm not even using the pool heater, but I'm not keen on ripping it out either. * The area of the plug just has warm water going through it, not super hot. *So, I'm thinking to just epoxy it closed. *In the Fall to winterize it I can just knock it out. * Any other ideas? can you get a tap and just try chasing the threads? A helicoil relies on re-drilling and re-tapping to a larger size. Can you simply re-drill and re-tap to 3/8" NPT and use a 3/8" NPT plug? That would require only ordinary drills and taps that are cheap and available singly, and of course a new plug.- Hide quoted text - - Show quoted text - That's a good point too. *You're right. *If you have to drill it for a helicoil, might as well just re-tap it to 3/8". *I've never tapped cast iron, but I guess it can be done, as the threads got there somehow to begin with. So, first plan is to try running a 1/4" tap through it to clean up the threads. *I found a tap yesterday, that wasn't easy. *HD had some tap, but no NPT. *Lowes had no taps at all. *Tried Autozone parts store, I figured they probably would not have NPT either. *Not only didn't they have any NPT, they hardly had any taps at all! But the Autozone guy suggested trying a old hardware store just up the street. *I didn't even know that store existed. *It looked like it was out of the 60's. * But the guy was sitting there, waiting for me. *Told him what I wanted, he walked behind the counter and in 30 secs I had it for $8. So, I'll let you know how I make out....- Hide quoted text - - Show quoted text - Oh, and forgot to mention. *I also got a short brass nipple and a valve, per nestork's suggestion. *Assuming I get it back together, I won't have to take it apart again.- Hide quoted text - - Show quoted text Update. I ran the 1/4" tap and then installed a short brass nipple with a lot of Teflon tape, followed by a valve. It sent in easier than it should, didn't want to make it up tight, so I didn't push it. But it's not leaking and with the valve, no need to screw with it again. IF anything, I would expect as the cast iron rusts some more, it may tighten itself up a bit. Thanks to all for the suggestions! |
#19
Posted to alt.home.repair
|
|||
|
|||
Helicoil or other ideas for 1/4" pipe threads?
Helicoil NPT inserts work GREAT and are very easy. Cast iron has so much carbon in it that it drills and taps like butter. There is nothing simpler to work with. Try MSC, ENCO, Grainger, or any real industrial supplier to get the Helicoli kits, They are expensive for a reason, they work. I am a machinist and tool and die maker in plastics. Do this daily
|
#20
Posted to alt.home.repair
|
|||
|
|||
Helicoil or other ideas for 1/4" pipe threads?
replying to imnew2nm, Matt wrote:
Doubt I'll get a reply since this is an old thread.... I'm using an 1/8 NPT helicoil thread repair kit (from grainger). How can I determine how far to tap the hole (since the it's a pitched thread) to get the correct dept of the insert so it's tight enough to seal? I'm taping an aluminum intake manifold for injector nozzles that need to be set to the correct depth. They can't be too loose and be are limited to how far you can tighten them. I can't find info anywhere to set the proper depth! I don't want to run the STI tap in too far and have the threads be too loose to seal the injector when bottomed out. -- for full context, visit https://www.homeownershub.com/mainte...ds-751579-.htm |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
"Helicoil" installation without the insert tool? Need advice | Metalworking | |||
How to cut threads on 3/4" metal water pipe that is in a hole in the ground. | Home Repair | |||
Cutting threads on the inside of a 3" socket end of PVC pipe | Metalworking | |||
Bright ideas for stripped threads in power socket mounting box | UK diy | |||
Pipe Threads | Metalworking |