[email protected][_2_] June 10th 13 01:43 AM

Helicoil or other ideas for 1/4" pipe threads?
 
I have a gas pool heater that has a 1/4"-18 NPT brass plug
that goes into a cast iron manifold. Over time the threads in
the cast iron have deteriorated and now I can't get the plug
in. I tried a new plug and one of the other plugs from another
location.

I checked to see if there is a helicoil for npt and they have it.
I'm not sure how the helicoil works for a pipe fitting so that it
doesn't leak, but I guess it must work. Problem is that so far,
I can only find the insert in packs of 12 for $25, the tap is $45.
Then I think you need an insertion tool?

So, any other ideas? It doesn't have to be the most 100%
reliable solution, ie if it drips a bit or fails, it's not the end of
the world. Also, I'm not even using the pool heater, but I'm
not keen on ripping it out either. The area of the plug just
has warm water going through it, not super hot. So, I'm
thinking to just epoxy it closed. In the Fall to winterize it I
can just knock it out. Any other ideas?

RBM[_2_] June 10th 13 01:48 AM

Helicoil or other ideas for 1/4" pipe threads?
 
On 6/9/2013 8:43 PM, wrote:
I have a gas pool heater that has a 1/4"-18 NPT brass plug
that goes into a cast iron manifold. Over time the threads in
the cast iron have deteriorated and now I can't get the plug
in. I tried a new plug and one of the other plugs from another
location.

I checked to see if there is a helicoil for npt and they have it.
I'm not sure how the helicoil works for a pipe fitting so that it
doesn't leak, but I guess it must work. Problem is that so far,
I can only find the insert in packs of 12 for $25, the tap is $45.
Then I think you need an insertion tool?

So, any other ideas? It doesn't have to be the most 100%
reliable solution, ie if it drips a bit or fails, it's not the end of
the world. Also, I'm not even using the pool heater, but I'm
not keen on ripping it out either. The area of the plug just
has warm water going through it, not super hot. So, I'm
thinking to just epoxy it closed. In the Fall to winterize it I
can just knock it out. Any other ideas?

can you get a tap and just try chasing the threads?

[email protected][_2_] June 10th 13 02:03 AM

Helicoil or other ideas for 1/4" pipe threads?
 
On Jun 9, 8:48*pm, RBM wrote:
On 6/9/2013 8:43 PM, wrote:



I have a gas pool heater that has a 1/4"-18 NPT brass plug
that goes into a cast iron manifold. *Over time the threads in
the cast iron have deteriorated and now I can't get the plug
in. *I tried a new plug and one of the other plugs from another
location.


I checked to see if there is a helicoil for npt and they have it.
I'm not sure how the helicoil works for a pipe fitting so that it
doesn't leak, but I guess it must work. *Problem is that so far,
I can only find the insert in packs of 12 for $25, the tap is $45.
Then I think you need an insertion tool?


So, any other ideas? * It doesn't have to be the most 100%
reliable solution, ie if it drips a bit or fails, it's not the end of
the world. * Also, I'm not even using the pool heater, but I'm
not keen on ripping it out either. * The area of the plug just
has warm water going through it, not super hot. *So, I'm
thinking to just epoxy it closed. *In the Fall to winterize it I
can just knock it out. * Any other ideas?


can you get a tap and just try chasing the threads?- Hide quoted text -

- Show quoted text -


Yes, that is a good idea. I had thought of doing that, but I didn't
have all my tools available here. And then I guess I got so excited by
A - finding out they they do make a helicoil for npt
B - finding out how much it costs!
that I forgot about just trying a tap.

I'm going to see if I have a 1/4" tap tomorrow.

Thanks
Even if I don't I can probably get a standard one cheap enough.

RBM[_2_] June 10th 13 02:14 AM

Helicoil or other ideas for 1/4" pipe threads?
 
On 6/9/2013 9:03 PM, wrote:
On Jun 9, 8:48 pm, RBM wrote:
On 6/9/2013 8:43 PM, wrote:



I have a gas pool heater that has a 1/4"-18 NPT brass plug
that goes into a cast iron manifold. Over time the threads in
the cast iron have deteriorated and now I can't get the plug
in. I tried a new plug and one of the other plugs from another
location.
I checked to see if there is a helicoil for npt and they have it.
I'm not sure how the helicoil works for a pipe fitting so that it
doesn't leak, but I guess it must work. Problem is that so far,
I can only find the insert in packs of 12 for $25, the tap is $45.
Then I think you need an insertion tool?
So, any other ideas? It doesn't have to be the most 100%
reliable solution, ie if it drips a bit or fails, it's not the end of
the world. Also, I'm not even using the pool heater, but I'm
not keen on ripping it out either. The area of the plug just
has warm water going through it, not super hot. So, I'm
thinking to just epoxy it closed. In the Fall to winterize it I
can just knock it out. Any other ideas?

can you get a tap and just try chasing the threads?- Hide quoted text -

- Show quoted text -

Yes, that is a good idea. I had thought of doing that, but I didn't
have all my tools available here. And then I guess I got so excited by
A - finding out they they do make a helicoil for npt
B - finding out how much it costs!
that I forgot about just trying a tap.

I'm going to see if I have a 1/4" tap tomorrow.

Thanks
Even if I don't I can probably get a standard one cheap enough.

I do repairs on cast iron underground fixture mounting boxes. (Kim J-2)
They have a cast iron thick cover with 1/2" NPT threads for the fixture
stems. Over time they get all coroded and the stems break off. I put the
cover in a vise and beat what's left of the stem out of the threads,
then chase the threads with a tap and they're practically good as new.
If anything maybe a little sloppy, so use more teflon.

Dean Hoffman[_13_] June 10th 13 03:52 AM

Helicoil or other ideas for 1/4" pipe threads?
 
On 6/9/13 8:03 PM, wrote:
On Jun 9, 8:48 pm, RBM wrote:


Yes, that is a good idea. I had thought of doing that, but I didn't
have all my tools available here. And then I guess I got so excited by
A - finding out they they do make a helicoil for npt
B - finding out how much it costs!
that I forgot about just trying a tap.

I'm going to see if I have a 1/4" tap tomorrow.

Thanks
Even if I don't I can probably get a standard one cheap enough.


Would drilling the hole out to 3/8" be an option?
A former drinkin' buddy told me the best way to start a tap. Put the
tap in a battery powered drill set to the slow speed. I've tried it
several times and it does work well.


Bob F June 10th 13 05:11 AM

Helicoil or other ideas for 1/4" pipe threads?
 
wrote:
I have a gas pool heater that has a 1/4"-18 NPT brass plug
that goes into a cast iron manifold. Over time the threads in
the cast iron have deteriorated and now I can't get the plug
in. I tried a new plug and one of the other plugs from another
location.

I checked to see if there is a helicoil for npt and they have it.
I'm not sure how the helicoil works for a pipe fitting so that it
doesn't leak, but I guess it must work. Problem is that so far,
I can only find the insert in packs of 12 for $25, the tap is $45.
Then I think you need an insertion tool?


Call a rental shop. They may sell the coils and rent the tool.




nestork June 10th 13 11:20 AM

I'd clean the theads with a 1/4 inch NPT tap and then screw a 1/4 inch NPT nipple (with plenty of teflon tape on it) and a 1/4 inch NPT ball valve into what you have.

From then on, you can simply connect to the brand new brass treads on the 1/4 inch ball valve. And, if those threads eventually wear out in time, just replace the 1/4 inch ball valve with a new one.

You should not have any problem finding 1/4 inch ball valves. I installed 1/8 inch ball valves on the NPT threads in my upstairs laundry room radiators. I purchased those 1/8 inch ball valves from my local Fairview Fittings distributor. If you look under "Hoses and Fittings" in your local yellow pages phone directory, at least one of the companies listed there will stock and sell you a 1/4 inch ball valve. Every plumbing wholesaler in our city or town will sell you a 1/4 inch ball valve if you pay cash too.

[email protected][_2_] June 10th 13 01:51 PM

Helicoil or other ideas for 1/4" pipe threads?
 
On Jun 10, 6:20*am, nestork wrote:
I'd clean the theads with a 1/4 inch NPT tap and then screw a 1/4 inch
NPT nipple (with plenty of teflon tape on it) and a 1/4 inch NPT ball
valve into what you have.

From then on, you can simply connect to the brand new brass treads on
the 1/4 inch ball valve. *And, if those threads eventually wear out in
time, just replace the 1/4 inch ball valve with a new one.

You should not have any problem finding 1/4 inch ball valves. *I
installed 1/8 inch ball valves on the NPT threads in my upstairs laundry
room radiators. *I purchased those 1/8 inch ball valves from my local
Fairview Fittings distributor. *If you look under "Hoses and Fittings"
in your local yellow pages phone directory, at least one of the
companies listed there will stock and sell you a 1/4 inch ball valve.
Every plumbing wholesaler in our city or town will sell you a 1/4 inch
ball valve if you pay cash too.

--
nestork



I was thinking along similar lines, ie using a nipple and a cap, so
that
if I get this straightened out, I won't have to screw with the cast
iron
part again. You would think by now they would have a pool heater
design where you could drain it through one brass valve they could
put at the low spot. Failing that, doing something like what you
suggest
on each drain, so that instead of screwing around with anything that
is cast iron, it would be only brass to brass. The way it exists now,
there
are three 1/4" brass/bronze plugs going into cast iron.

[email protected] June 10th 13 04:23 PM

Helicoil or other ideas for 1/4" pipe threads?
 
On Sun, 09 Jun 2013 20:48:04 -0400, RBM wrote:

On 6/9/2013 8:43 PM, wrote:
I have a gas pool heater that has a 1/4"-18 NPT brass plug
that goes into a cast iron manifold. Over time the threads in
the cast iron have deteriorated and now I can't get the plug
in. I tried a new plug and one of the other plugs from another
location.

I checked to see if there is a helicoil for npt and they have it.
I'm not sure how the helicoil works for a pipe fitting so that it
doesn't leak, but I guess it must work. Problem is that so far,
I can only find the insert in packs of 12 for $25, the tap is $45.
Then I think you need an insertion tool?

So, any other ideas? It doesn't have to be the most 100%
reliable solution, ie if it drips a bit or fails, it's not the end of
the world. Also, I'm not even using the pool heater, but I'm
not keen on ripping it out either. The area of the plug just
has warm water going through it, not super hot. So, I'm
thinking to just epoxy it closed. In the Fall to winterize it I
can just knock it out. Any other ideas?

can you get a tap and just try chasing the threads?

And if the threads are too far gone, drill it out and tap to 3/8 npt
and install a reducer bushing.

[email protected][_2_] June 10th 13 04:56 PM

Helicoil or other ideas for 1/4" pipe threads?
 
On Jun 10, 11:31*am, wrote:
On Mon, 10 Jun 2013 11:23:25 -0400, wrote:
On Sun, 09 Jun 2013 20:48:04 -0400, RBM wrote:


On 6/9/2013 8:43 PM, wrote:
I have a gas pool heater that has a 1/4"-18 NPT brass plug
that goes into a cast iron manifold. *Over time the threads in
the cast iron have deteriorated and now I can't get the plug
in. *I tried a new plug and one of the other plugs from another
location.


I checked to see if there is a helicoil for npt and they have it.
I'm not sure how the helicoil works for a pipe fitting so that it
doesn't leak, but I guess it must work. *Problem is that so far,
I can only find the insert in packs of 12 for $25, the tap is $45.
Then I think you need an insertion tool?


So, any other ideas? * It doesn't have to be the most 100%
reliable solution, ie if it drips a bit or fails, it's not the end of
the world. * Also, I'm not even using the pool heater, but I'm
not keen on ripping it out either. * The area of the plug just
has warm water going through it, not super hot. *So, I'm
thinking to just epoxy it closed. *In the Fall to winterize it I
can just knock it out. * Any other ideas?
can you get a tap and just try chasing the threads?

And if the threads are too far gone, drill it out and tap to 3/8 npt
and install a reducer bushing.


I suppose if you don't want to invest in any taps, you could epoxy a
1/4" pipe nipple in there and put a cap on it.- Hide quoted text -

- Show quoted text -


I checked and I don't have a tap. But buying a regular tap isn't a
problem. So, that's the plan of record right now, try using a 1/4"
tap to restore the threads. If it works, I'll put in a nipple so I
won;t
have to screw around with that connection again.

Pete C.[_3_] June 10th 13 08:22 PM

Helicoil or other ideas for 1/4" pipe threads?
 

RBM wrote:

On 6/9/2013 8:43 PM, wrote:
I have a gas pool heater that has a 1/4"-18 NPT brass plug
that goes into a cast iron manifold. Over time the threads in
the cast iron have deteriorated and now I can't get the plug
in. I tried a new plug and one of the other plugs from another
location.

I checked to see if there is a helicoil for npt and they have it.
I'm not sure how the helicoil works for a pipe fitting so that it
doesn't leak, but I guess it must work. Problem is that so far,
I can only find the insert in packs of 12 for $25, the tap is $45.
Then I think you need an insertion tool?

So, any other ideas? It doesn't have to be the most 100%
reliable solution, ie if it drips a bit or fails, it's not the end of
the world. Also, I'm not even using the pool heater, but I'm
not keen on ripping it out either. The area of the plug just
has warm water going through it, not super hot. So, I'm
thinking to just epoxy it closed. In the Fall to winterize it I
can just knock it out. Any other ideas?

can you get a tap and just try chasing the threads?


A helicoil relies on re-drilling and re-tapping to a larger size. Can
you simply re-drill and re-tap to 3/8" NPT and use a 3/8" NPT plug? That
would require only ordinary drills and taps that are cheap and available
singly, and of course a new plug.

[email protected] June 10th 13 08:58 PM

Helicoil or other ideas for 1/4" pipe threads?
 
On Sunday, June 9, 2013 8:43:05 PM UTC-4, wrote:
Any other ideas?


The cost of the helicoil certainly has to exceed the cost of a new manifold.

I know you're "not keen" on fixing it right, but this might be a good time to reconsider that solution as a possibility.


jamesgang June 10th 13 09:10 PM

Helicoil or other ideas for 1/4" pipe threads?
 
On Sunday, June 9, 2013 8:43:05 PM UTC-4, wrote:
I have a gas pool heater that has a 1/4"-18 NPT brass plug

that goes into a cast iron manifold. Over time the threads in

the cast iron have deteriorated and now I can't get the plug

in. I tried a new plug and one of the other plugs from another

location.



I checked to see if there is a helicoil for npt and they have it.

I'm not sure how the helicoil works for a pipe fitting so that it

doesn't leak, but I guess it must work. Problem is that so far,

I can only find the insert in packs of 12 for $25, the tap is $45.

Then I think you need an insertion tool?



So, any other ideas? It doesn't have to be the most 100%

reliable solution, ie if it drips a bit or fails, it's not the end of

the world. Also, I'm not even using the pool heater, but I'm

not keen on ripping it out either. The area of the plug just

has warm water going through it, not super hot. So, I'm

thinking to just epoxy it closed. In the Fall to winterize it I

can just knock it out. Any other ideas?


Chasing with a tap has almost always fixed my problems with corroded female pipe thread. That and a little extra teflon tape. The yellow tape for gas is a lot thicker.

Larry W June 10th 13 11:54 PM

Helicoil or other ideas for 1/4" pipe threads?
 
In article ,
wrote:
I have a gas pool heater that has a 1/4"-18 NPT brass plug
that goes into a cast iron manifold. Over time the threads in
the cast iron have deteriorated and now I can't get the plug
in. I tried a new plug and one of the other plugs from another
location.

I checked to see if there is a helicoil for npt and they have it.
I'm not sure how the helicoil works for a pipe fitting so that it
doesn't leak, but I guess it must work. Problem is that so far,
I can only find the insert in packs of 12 for $25, the tap is $45.
Then I think you need an insertion tool?

So, any other ideas? It doesn't have to be the most 100%
reliable solution, ie if it drips a bit or fails, it's not the end of
the world. Also, I'm not even using the pool heater, but I'm
not keen on ripping it out either. The area of the plug just
has warm water going through it, not super hot. So, I'm
thinking to just epoxy it closed. In the Fall to winterize it I
can just knock it out. Any other ideas?


A few ideas in no particular order:

* If the cast iron manifold is thick enough, you may be able to just run
a 1/4 inch NPT tap into it and cut new threads. The plug will just
set a littledeeper than originally before getting tight.

* Again, if the CI manifold design allows, drill out the hole and tap for
3/8 inch NPT. You could use a 3/8 to 1/4 pipe bushing instead of a
3/8 plug, so the same problem doesn't develop again later.

* There are some other thread choices you could also make here, with a
plug sealed by a gasket or O ring, similar to an engine oil drain plug.

* For that matter, there are rubber oil drain plug replacements available
pretty cheaply that might be worth trying. The plugs I'm thinking of do
not thread into the hole, but expand into it after being released by the
installation tool that they are sold together with. Not sure what kind
of pressure they can take, though.

* Clean up the threads as best you can and instead of epoxying in a 1/4
inch plug, epoxy in a 1/4" to 1/8" pipe bushing. That way you'll still be
able to remove the plug for maintenance if desired.


--
Better to be stuck up in a tree than tied to one.

Larry W. - Baltimore Maryland - lwasserm(a)sdf. lonestar.org

nestork June 11th 13 02:30 AM

Yet another idea...

I know that it wasn't possible to weld cast iron years ago, but they're doing it now in cylinder and engine block rebuilding shops. Maybe you could take that manifold to a cylinder head rebuilding shop and have them weld a 1/4 inch steel nipple into the threaded opening you're having difficulty with. The wall thickness of the nipple might be too thin for welding, but I expect you can get 1/4 inch nipples in Schedule 80 and 120 for greater wall thicknesses if you special order them.

[email protected][_2_] June 11th 13 01:22 PM

Helicoil or other ideas for 1/4" pipe threads?
 
On Jun 10, 3:22*pm, "Pete C." wrote:
RBM wrote:

On 6/9/2013 8:43 PM, wrote:
I have a gas pool heater that has a 1/4"-18 NPT brass plug
that goes into a cast iron manifold. *Over time the threads in
the cast iron have deteriorated and now I can't get the plug
in. *I tried a new plug and one of the other plugs from another
location.


I checked to see if there is a helicoil for npt and they have it.
I'm not sure how the helicoil works for a pipe fitting so that it
doesn't leak, but I guess it must work. *Problem is that so far,
I can only find the insert in packs of 12 for $25, the tap is $45.
Then I think you need an insertion tool?


So, any other ideas? * It doesn't have to be the most 100%
reliable solution, ie if it drips a bit or fails, it's not the end of
the world. * Also, I'm not even using the pool heater, but I'm
not keen on ripping it out either. * The area of the plug just
has warm water going through it, not super hot. *So, I'm
thinking to just epoxy it closed. *In the Fall to winterize it I
can just knock it out. * Any other ideas?

can you get a tap and just try chasing the threads?


A helicoil relies on re-drilling and re-tapping to a larger size. Can
you simply re-drill and re-tap to 3/8" NPT and use a 3/8" NPT plug? That
would require only ordinary drills and taps that are cheap and available
singly, and of course a new plug.- Hide quoted text -

- Show quoted text -


That's a good point too. You're right. If you have to drill it for
a helicoil, might as well just re-tap it to 3/8". I've never tapped
cast iron, but I guess it can be done, as the threads got there
somehow to begin with.

So, first plan is to try running a 1/4" tap through it to clean up
the threads. I found a tap yesterday, that wasn't easy. HD
had some tap, but no NPT. Lowes had no taps at all. Tried
Autozone parts store, I figured they probably would not have
NPT either. Not only didn't they have any NPT, they hardly
had any taps at all!

But the Autozone guy suggested trying a old hardware store
just up the street. I didn't even know that store existed. It
looked like it was out of the 60's. But the guy was sitting there,
waiting for me. Told him what I wanted, he walked behind the
counter and in 30 secs I had it for $8.

So, I'll let you know how I make out....

[email protected][_2_] June 11th 13 01:24 PM

Helicoil or other ideas for 1/4" pipe threads?
 
On Jun 11, 8:22*am, "
wrote:
On Jun 10, 3:22*pm, "Pete C." wrote:





RBM wrote:


On 6/9/2013 8:43 PM, wrote:
I have a gas pool heater that has a 1/4"-18 NPT brass plug
that goes into a cast iron manifold. *Over time the threads in
the cast iron have deteriorated and now I can't get the plug
in. *I tried a new plug and one of the other plugs from another
location.


I checked to see if there is a helicoil for npt and they have it.
I'm not sure how the helicoil works for a pipe fitting so that it
doesn't leak, but I guess it must work. *Problem is that so far,
I can only find the insert in packs of 12 for $25, the tap is $45.
Then I think you need an insertion tool?


So, any other ideas? * It doesn't have to be the most 100%
reliable solution, ie if it drips a bit or fails, it's not the end of
the world. * Also, I'm not even using the pool heater, but I'm
not keen on ripping it out either. * The area of the plug just
has warm water going through it, not super hot. *So, I'm
thinking to just epoxy it closed. *In the Fall to winterize it I
can just knock it out. * Any other ideas?
can you get a tap and just try chasing the threads?


A helicoil relies on re-drilling and re-tapping to a larger size. Can
you simply re-drill and re-tap to 3/8" NPT and use a 3/8" NPT plug? That
would require only ordinary drills and taps that are cheap and available
singly, and of course a new plug.- Hide quoted text -


- Show quoted text -


That's a good point too. *You're right. *If you have to drill it for
a helicoil, might as well just re-tap it to 3/8". *I've never tapped
cast iron, but I guess it can be done, as the threads got there
somehow to begin with.

So, first plan is to try running a 1/4" tap through it to clean up
the threads. *I found a tap yesterday, that wasn't easy. *HD
had some tap, but no NPT. *Lowes had no taps at all. *Tried
Autozone parts store, I figured they probably would not have
NPT either. *Not only didn't they have any NPT, they hardly
had any taps at all!

But the Autozone guy suggested trying a old hardware store
just up the street. *I didn't even know that store existed. *It
looked like it was out of the 60's. * But the guy was sitting there,
waiting for me. *Told him what I wanted, he walked behind the
counter and in 30 secs I had it for $8.

So, I'll let you know how I make out....- Hide quoted text -

- Show quoted text -


Oh, and forgot to mention. I also got a short brass nipple and
a valve, per nestork's suggestion. Assuming I get it back together,
I won't have to take it apart again.

[email protected][_2_] June 12th 13 10:47 PM

Helicoil or other ideas for 1/4" pipe threads?
 
On Jun 11, 8:24*am, "
wrote:
On Jun 11, 8:22*am, "
wrote:





On Jun 10, 3:22*pm, "Pete C." wrote:


RBM wrote:


On 6/9/2013 8:43 PM, wrote:
I have a gas pool heater that has a 1/4"-18 NPT brass plug
that goes into a cast iron manifold. *Over time the threads in
the cast iron have deteriorated and now I can't get the plug
in. *I tried a new plug and one of the other plugs from another
location.


I checked to see if there is a helicoil for npt and they have it.
I'm not sure how the helicoil works for a pipe fitting so that it
doesn't leak, but I guess it must work. *Problem is that so far,
I can only find the insert in packs of 12 for $25, the tap is $45..
Then I think you need an insertion tool?


So, any other ideas? * It doesn't have to be the most 100%
reliable solution, ie if it drips a bit or fails, it's not the end of
the world. * Also, I'm not even using the pool heater, but I'm
not keen on ripping it out either. * The area of the plug just
has warm water going through it, not super hot. *So, I'm
thinking to just epoxy it closed. *In the Fall to winterize it I
can just knock it out. * Any other ideas?
can you get a tap and just try chasing the threads?


A helicoil relies on re-drilling and re-tapping to a larger size. Can
you simply re-drill and re-tap to 3/8" NPT and use a 3/8" NPT plug? That
would require only ordinary drills and taps that are cheap and available
singly, and of course a new plug.- Hide quoted text -


- Show quoted text -


That's a good point too. *You're right. *If you have to drill it for
a helicoil, might as well just re-tap it to 3/8". *I've never tapped
cast iron, but I guess it can be done, as the threads got there
somehow to begin with.


So, first plan is to try running a 1/4" tap through it to clean up
the threads. *I found a tap yesterday, that wasn't easy. *HD
had some tap, but no NPT. *Lowes had no taps at all. *Tried
Autozone parts store, I figured they probably would not have
NPT either. *Not only didn't they have any NPT, they hardly
had any taps at all!


But the Autozone guy suggested trying a old hardware store
just up the street. *I didn't even know that store existed. *It
looked like it was out of the 60's. * But the guy was sitting there,
waiting for me. *Told him what I wanted, he walked behind the
counter and in 30 secs I had it for $8.


So, I'll let you know how I make out....- Hide quoted text -


- Show quoted text -


Oh, and forgot to mention. *I also got a short brass nipple and
a valve, per nestork's suggestion. *Assuming I get it back together,
I won't have to take it apart again.- Hide quoted text -

- Show quoted text




Update. I ran the 1/4" tap and then installed a short brass nipple
with a lot
of Teflon tape, followed by a valve. It sent in easier than it
should, didn't want
to make it up tight, so I didn't push it. But it's not leaking and
with the valve, no
need to screw with it again. IF anything, I would expect as the cast
iron rusts
some more, it may tighten itself up a bit.

Thanks to all for the suggestions!

[email protected] November 10th 14 05:16 AM

Helicoil or other ideas for 1/4" pipe threads?
 
Helicoil NPT inserts work GREAT and are very easy. Cast iron has so much carbon in it that it drills and taps like butter. There is nothing simpler to work with. Try MSC, ENCO, Grainger, or any real industrial supplier to get the Helicoli kits, They are expensive for a reason, they work. I am a machinist and tool and die maker in plastics. Do this daily

Matt[_15_] February 27th 17 12:44 PM

Helicoil or other ideas for 1/4" pipe threads?
 
replying to imnew2nm, Matt wrote:
Doubt I'll get a reply since this is an old thread.... I'm using an 1/8 NPT
helicoil thread repair kit (from grainger). How can I determine how far to tap
the hole (since the it's a pitched thread) to get the correct dept of the
insert so it's tight enough to seal? I'm taping an aluminum intake manifold
for injector nozzles that need to be set to the correct depth. They can't be
too loose and be are limited to how far you can tighten them. I can't find
info anywhere to set the proper depth! I don't want to run the STI tap in too
far and have the threads be too loose to seal the injector when bottomed out.

--
for full context, visit https://www.homeownershub.com/mainte...ds-751579-.htm




All times are GMT +1. The time now is 09:17 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004 - 2014 DIYbanter