I have hot water heating, and removed all the baseboard heaters to refinish
living room floor. My house was built in 1951 and has old style baseboard
heaters they have two 1/2 inch copper pipes that run through them and each
section is 54 inch long and sweat soldered together...anyway about 36 ft
altogether. I made a few cuts to get it apart and now have run into a
problem trying to put back together...it seems that the 1/2 inch copper they
used in 1951 (or at least what was used in my system) is about 1/16 inch
bigger than the fittings - 1/2" elbows & couplers.....................what
to do? I have tired using emery cloth to grind down old copper a little so
the fitting will go over it, but it is not working, after much work can just
get fitting on like 1/16 inch..... I can not afford to go out and buy all
new heaters right now......I only have 2 90's and about 8 couplers to sweat
together........what to do???? any help appreciated.
  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 177
Default Plumbing question

wrote:
I have hot water heating, and removed all the baseboard heaters to refinish
living room floor. My house was built in 1951 and has old style baseboard
heaters they have two 1/2 inch copper pipes that run through them and each
section is 54 inch long and sweat soldered together...anyway about 36 ft
altogether. I made a few cuts to get it apart and now have run into a
problem trying to put back together...it seems that the 1/2 inch copper they
used in 1951 (or at least what was used in my system) is about 1/16 inch
bigger than the fittings - 1/2" elbows & couplers.....................what
to do? I have tired using emery cloth to grind down old copper a little so
the fitting will go over it, but it is not working, after much work can just
get fitting on like 1/16 inch..... I can not afford to go out and buy all
new heaters right now......I only have 2 90's and about 8 couplers to sweat
together........what to do???? any help appreciated.


Any chance those olde heaters use 5/8" pipe and not the 1/2" pipe you're
described?

You know, there is a 5/8" copper pipe standard:

http://www.engineeringtoolbox.com/as...bes-d_779.html

Have you used a vernier caliper or a micrometer to confirm the pipe's
outside diameter?

And, they do make fittings for 5/8" copper pipe:

http://www.hardwareandtools.com/invt/u102106

Good luck, let us know how you make out,

Jeff

--
Jeffry Wisnia
(W1BSV + Brass Rat '57 EE)
The speed of light is 1.8*10e12 furlongs per fortnight.
  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,473
Default Plumbing question


wrote in message
...
I have hot water heating, and removed all the baseboard heaters to
refinish
living room floor. My house was built in 1951 and has old style baseboard
heaters they have two 1/2 inch copper pipes that run through them and each
section is 54 inch long and sweat soldered together...anyway about 36 ft
altogether. I made a few cuts to get it apart and now have run into a
problem trying to put back together...it seems that the 1/2 inch copper
they
used in 1951 (or at least what was used in my system) is about 1/16 inch
bigger than the fittings - 1/2" elbows & couplers.....................what
to do? I have tired using emery cloth to grind down old copper a little
so
the fitting will go over it, but it is not working, after much work can
just
get fitting on like 1/16 inch..... I can not afford to go out and buy all
new heaters right now......I only have 2 90's and about 8 couplers to
sweat
together........what to do???? any help appreciated.



I would expect them to be 3/4", but it's possible they're 5/8" as Jeff said


  #6   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 18,538
Default Plumbing question

On Sat, 17 Oct 2009 17:25:40 -0400, jeff_wisnia
wrote:

wrote:
I have hot water heating, and removed all the baseboard heaters to refinish
living room floor. My house was built in 1951 and has old style baseboard
heaters they have two 1/2 inch copper pipes that run through them and each
section is 54 inch long and sweat soldered together...anyway about 36 ft
altogether. I made a few cuts to get it apart and now have run into a
problem trying to put back together...it seems that the 1/2 inch copper they
used in 1951 (or at least what was used in my system) is about 1/16 inch
bigger than the fittings - 1/2" elbows & couplers.....................what
to do? I have tired using emery cloth to grind down old copper a little so
the fitting will go over it, but it is not working, after much work can just
get fitting on like 1/16 inch..... I can not afford to go out and buy all
new heaters right now......I only have 2 90's and about 8 couplers to sweat
together........what to do???? any help appreciated.


Any chance those olde heaters use 5/8" pipe and not the 1/2" pipe you're
described?

You know, there is a 5/8" copper pipe standard:

http://www.engineeringtoolbox.com/as...bes-d_779.html

Have you used a vernier caliper or a micrometer to confirm the pipe's
outside diameter?

And, they do make fittings for 5/8" copper pipe:

http://www.hardwareandtools.com/invt/u102106

Good luck, let us know how you make out,

Jeff



I was going to say the same. MOST Hydronic heating systems used a lot
of 5/8" copper.
  #7   Report Post  
Posted to alt.home.repair
jim jim is offline
external usenet poster
 
Posts: 206
Default Plumbing question

On Oct 17, 8:20*pm, wrote:
On Sat, 17 Oct 2009 17:25:40 -0400, jeff_wisnia





wrote:
wrote:
I have hot water heating, and removed *all the baseboard heaters to refinish
living room floor. *My house was built in 1951 and has old style baseboard
heaters they have two 1/2 inch copper pipes that run through them and each
section is 54 inch long and sweat soldered together...anyway about 36 ft
altogether. I made a few cuts to get it apart and now have run into a
problem trying to put back together...it seems that the 1/2 inch copper they
used in 1951 (or at least what was used in my system) is about 1/16 inch
bigger than the fittings - 1/2" elbows & couplers.....................what
to do? *I have tired using emery cloth to grind down old copper a little so
the fitting will go over it, but it is not working, after much work can just
get fitting on like 1/16 inch..... I can not afford to go out and buy all
new heaters right now......I only have 2 90's and about 8 couplers to sweat
together........what to do???? any help appreciated.


Any chance those olde heaters use 5/8" pipe and not the 1/2" pipe you're
described?


You know, there is a 5/8" copper pipe standard:


http://www.engineeringtoolbox.com/as...bes-d_779.html


Have you used a vernier caliper or a micrometer to confirm the pipe's
outside diameter?


And, they do make fittings for 5/8" copper pipe:


http://www.hardwareandtools.com/invt/u102106


Good luck, let us know how you make out,


Jeff


I was going to say the same. MOST Hydronic heating systems used a lot
of 5/8" copper.- Hide quoted text -

- Show quoted text -


You have copper tubing not pipe and you should be able to get the
fittings at a wholesale not Home Depot Refridge fittings will work do
not sand the pipe thinner as it is holding some pressure in the system
  #8   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 25
Default Plumbing question

I did take a sample to ACE Hardware this afternoon, they measured and said
was about 1/16 inch larger than 1/2 inch copper......I do not believe it is
5/8....I just checked and compared with some new 1/2 inch I had in basement
and there is just slight difference in size.... pretty much, they look the
same to me.
  #9   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 11,640
Default Plumbing question


wrote in message
...
I did take a sample to ACE Hardware this afternoon, they measured and said
was about 1/16 inch larger than 1/2 inch copper......I do not believe it
is
5/8....I just checked and compared with some new 1/2 inch I had in
basement
and there is just slight difference in size.... pretty much, they look the
same to me.


That would be 11/16 then. Or very close to 17mm.
Get a micrometer and get the actual size and you may do better finding what
you really need.

Try these guys
http://www.worldwidemetric.com/fittings_coper_sol.asp

I have no idea why metric tubing would be in a US house built that year
though. It would not be common at all.


  #10   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 10,530
Default Plumbing question

HVAC tubing is typically smaller. For example, 3/4 water
copper is the same size as 7/8 HVAC tubing. But, it's
possible.

--
Christopher A. Young
Learn more about Jesus
www.lds.org
..


"Bob F" wrote in message
...

IIRC, there may be fittings used for A/C systems or
something that are slightly
different sizes than water pipe fittings. They might be what
you need.





  #11   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,473
Default Plumbing question


"Stormin Mormon" wrote in message
...
HVAC tubing is typically smaller. For example, 3/4 water
copper is the same size as 7/8 HVAC tubing. But, it's
possible.

--
Christopher A. Young
Learn more about Jesus
www.lds.org
.


"Bob F" wrote in message
...

IIRC, there may be fittings used for A/C systems or
something that are slightly
different sizes than water pipe fittings. They might be what
you need.

You need to check your numbers



  #12   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 3,761
Default Plumbing question

Stormin Mormon wrote:
HVAC tubing is typically smaller. For example, 3/4 water
copper is the same size as 7/8 HVAC tubing. But, it's
possible.


HVAC tubing is measured by OD, plumbing is measured by ID.
That's why I have calipers in my pocket.

http://www.generaltools.com/Products...er__132ME.aspx

TDD
  #13   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,227
Default Plumbing question

On Oct 17, 7:42*pm, wrote:
I did take a sample to ACE Hardware this afternoon, they measured and said
was about 1/16 inch larger than 1/2 inch copper......I do not believe it is
5/8....I just checked and compared with some new 1/2 inch I had in basement
and there is just slight difference in size.... pretty much, they look the
same to me.


What is the od measurement?

What did the ace folks measure it with? a tape?

You really don't care that is measures "about 1/16 inch larger than
1/2 inch copper", that is a pretty much useless piece of information

.......you want the actual outside diameter, measured with a caliper
to the nearest .005"

standard copper tube has the following "od's" ......... in your size
range
..5, .625 & .750

any other od's are not standard copper "tube"

ACR tube has the same od's but the size designations are
"shifted".........go figure?

I've been working with copper tube since the 60's and the sizes
haven't changed


for the spec sizes visit

http://www.copper.org/applications/p...dex_table.html

cheers
Bob



Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Plumbing question RepairNovice[_2_] Home Repair 9 July 12th 08 06:28 PM
Plumbing question dean Home Repair 3 July 15th 07 01:55 PM
Concrete question (regarding previous plumbing question) [email protected] Home Repair 2 October 17th 06 08:07 PM
Plumbing question SteveB Home Repair 1 December 23rd 04 04:21 PM
Plumbing question Art Home Repair 13 December 9th 04 10:34 PM


All times are GMT +1. The time now is 10:49 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"