Default Sump Pump Replacement


RANDY ALEXANDER
-------------------------------------

I have a frozen discharge line on my Sump system. I caused this by
extending the discharge line into the ditch last summer to make my lawn
look better. We had a thaw & refreezing last week and my discharge line is
now frozen solid.
I initially thought it was a pump problem and replaced the pump. My old
one was 4/10 hp and looks about 25-30 years old. I am going to now cut the
discharge line 6" from the outside wall & conn a temp line till spring
then reconnect. I am replacing with a 1/4 hp submersible pump.
Now my questions, I think the 1/4 hp is enough it has to pump up 6' then
the discharge line is a slight downhill grade all the way to the ditch but
would appreciate any comments. The old pump system has a brass chk valve
on the horizontal section 6" up but no relief hole in line, it always
worked fine. All instructions for new pumps say to drill 1/8" relief hole
above pump but below water line. I did do this and it stirs up the water
in the Sump pit as it has a soft bottom nd I'm worried it will clog the
pump. Is this reief hole neccesary? Any other suggestions, Thx


##-----------------------------------------------##
Delivered via http://www.thestuccocompany.com/
Building Construction and Maintenance Forum
Web and RSS access to your favorite newsgroup -
alt.home.repair - 337443 messages and counting!
##-----------------------------------------------##
  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 4,500
Default Sump Pump Replacement

On Jan 28, 12:21*pm, (Randy
Alexander) wrote:
RANDY ALEXANDER
-------------------------------------

I have a frozen discharge line on my Sump system. I caused this by
extending the discharge line into the ditch last summer to make my lawn
look better. We had a thaw & refreezing last week and my discharge line is
now frozen solid.
I initially thought it was a pump problem and replaced the pump. My old
one was 4/10 hp and looks about 25-30 years old. I am going to now cut the
discharge line 6" from the outside wall & conn a temp line till spring
then reconnect. I am replacing with a 1/4 hp submersible pump.
Now my questions, I think the 1/4 hp is enough it has to pump up 6' then
the discharge line is a slight downhill grade all the way to the ditch but
would appreciate any comments. The old pump system has a brass chk valve
on the horizontal section 6" up but no relief hole in line, it always
worked fine. All instructions for new pumps say to drill 1/8" relief hole
above pump but below water line. I did do this and it stirs up the water
in the Sump pit as it has a soft bottom nd I'm worried it will clog the
pump. Is this reief hole neccesary? Any other suggestions, Thx

##-----------------------------------------------##
Delivered via *http://www.thestuccocompany.com/
Building Construction and Maintenance Forum
Web and RSS access to your favorite newsgroup -
alt.home.repair - 337443 messages and counting!
##-----------------------------------------------##


I've also seen sump pumps installations that did not have a relief
hole and worked fine. It probably depends to some extent on the
design of the pump. The hole is there to prevent the pump from
becoming air-locked. That could occur if the sump pump goes dry and
all the water is gone. When the pump starts, it may be full of air
and not able to clear itself. The hole provides a way for the air to
escape and water to enter.

If stirring up muck is an issue, you can fashion something to clamp on
to the pipe in front of the hole for the water to hit and difuse. A z
shaped strip of metal should work.


  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 333
Default Sump Pump Replacement

On Jan 28, 12:21�pm, (Randy
Alexander) wrote:
RANDY ALEXANDER
-------------------------------------

I have a frozen discharge line on my Sump system. I caused this by
extending the discharge line into the ditch last summer to make my lawn
look better. We had a thaw & refreezing last week and my discharge line is
now frozen solid.
I initially thought it was a pump problem and replaced the pump. My old
one was 4/10 hp and looks about 25-30 years old. I am going to now cut the
discharge line 6" from the outside wall & conn a temp line till spring
then reconnect. I am replacing with a 1/4 hp submersible pump.
Now my questions, I think the 1/4 hp is enough it has to pump up 6' then
the discharge line is a slight downhill grade all the way to the ditch but
would appreciate any comments. The old pump system has a brass chk valve
on the horizontal section 6" up but no relief hole in line, it always
worked fine. All instructions for new pumps say to drill 1/8" relief hole
above pump but below water line. I did do this and it stirs up the water
in the Sump pit as it has a soft bottom nd I'm worried it will clog the
pump. Is this reief hole neccesary? Any other suggestions, Thx

##-----------------------------------------------##
Delivered via �http://www.thestuccocompany.com/
Building Construction and Maintenance Forum
Web and RSS access to your favorite newsgroup -
alt.home.repair - 337443 messages and counting!
##-----------------------------------------------##


The only reason I can think of for a relief hole is so that if your
switch sticks in such a way that the motor keeps running. The relief
hole will circulate a small amount of water to keep the pump cool.
Personally, I would take the chance that the switch won't stick if I
had a soft bottom sump like yours. If I had a sump container, then I
might drill the hole.

Another reason is it could be an anti siphon hole. If the end of your
pipe (in the ditch) is lower than your sump and it is water tight. it
will siphon after the line fills with water.

Keep the check valve in place, you'll need that. Your 1/4 HP pump
sounds like enough pump up 6 foot without a problem.

Hank
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Where can I find a 22" by 2" replacement floor grate for a sump pump? Robert Green Home Repair 8 June 2nd 08 07:11 PM
Sump Pump Clunk After Backup Pump Install [email protected] Home Repair 6 April 19th 07 05:18 PM
Sump pump replacement gerry gardiner Home Repair 6 November 19th 06 12:29 PM
Sump Pump vs. No Sump Pump (Questions) BroJack Home Repair 4 September 5th 04 06:56 PM
Specify/Install Sump Pit and Sump Pump Puddin' Man Home Repair 4 November 26th 03 03:59 PM


All times are GMT +1. The time now is 01:48 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"