Home Repair (alt.home.repair) For all homeowners and DIYers with many experienced tradesmen. Solve your toughest home fix-it problems.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 199
Default Copper Water Line Gages, And Usage ?

Hello,

Live in a 35 year old house outside of Boston.

Had a leak in a Copper water pipe that the plumber finally found.

Unfortunately, I forgot to ask him if it was in a hot or cold line, as this
might, perhaps, be meaningful ?

Anyway, what surprised me was that it was pinhole leak in the middle of a
run.
Not at a joint or fitting, etc. Right in the middle of a line.

Apparently they used the thinnest Copper they could find when they built the
place.
I used a caliper on it, and found it to be 0.028, which I guess is a grade M
(outside diameter of 5/8 inch)

But, it still should take the household pressure without any problem, I
would think.
True ?

The plumber replaced it with heavier wall stuff of approx. 0.038, which is
probably
Type L

Questions:

a. What might make a pinhole leake in the middle of a clear run ?
I guess the pinhole can be considered as a corrosion type of breakthrough.

b. How common is something like this is the thinwall Type M tubing ?
What causes ?

c. 35 years ago, was this (Type M) a common Copper gage they used for
household
hot and cold water lines ?

d. Is it still allowed, or the Code prohibits it now all over ?

Any thoughts on this would be most appreciated.

Thanks,
Bob.



  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 6,199
Default Copper Water Line Gages, And Usage ?

On Aug 13, 7:42�am, "Robert11" wrote:
Hello,

Live in a 35 year old house outside of Boston.

Had a leak in a Copper water pipe that the plumber finally found.

Unfortunately, I forgot to ask him if it was in a hot or cold line, as this
might, perhaps, be meaningful ?

Anyway, what surprised me was that it was pinhole leak in the middle of a
run.
Not at a joint or fitting, etc. �Right in the middle of a line.

Apparently they used the thinnest Copper they could find when they built the
place.
I used a caliper on it, and found it to be 0.028, which I guess is a grade M
(outside diameter of 5/8 inch)

But, it still should take the household pressure without any problem, I
would think.
True ?

The plumber replaced it with heavier wall stuff of approx. 0.038, which is
probably
Type L

Questions:

a. �What might make a pinhole leake in the middle of a clear run ?
I guess the pinhole can be considered as a corrosion type of breakthrough..

b. �How common is something like this is the thinwall Type M tubing ?
What causes ?

c. �35 years ago, was this (Type M) a common Copper gage they used for
household
hot and cold water lines ?

d. �Is it still allowed, or the Code prohibits it now all over ?

Any thoughts on this would be most appreciated.

Thanks,
Bob.


might have been bad from day one, a weakness in the origiinal copper
that ook 35 years to fail.

I wouldnt worry about it...

any chance a fastner like screw rubbed it?
  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 15
Default Copper Water Line Gages, And Usage ?

Robert11 wrote:
Hello,

Live in a 35 year old house outside of Boston.

Had a leak in a Copper water pipe that the plumber finally found.

Unfortunately, I forgot to ask him if it was in a hot or cold line, as this
might, perhaps, be meaningful ?

Anyway, what surprised me was that it was pinhole leak in the middle of a
run.
Not at a joint or fitting, etc. Right in the middle of a line.

Apparently they used the thinnest Copper they could find when they built the
place.
I used a caliper on it, and found it to be 0.028, which I guess is a grade M
(outside diameter of 5/8 inch)

But, it still should take the household pressure without any problem, I
would think.
True ?

The plumber replaced it with heavier wall stuff of approx. 0.038, which is
probably
Type L

Questions:

a. What might make a pinhole leake in the middle of a clear run ?
I guess the pinhole can be considered as a corrosion type of breakthrough.

b. How common is something like this is the thinwall Type M tubing ?
What causes ?

c. 35 years ago, was this (Type M) a common Copper gage they used for
household
hot and cold water lines ?

d. Is it still allowed, or the Code prohibits it now all over ?

Any thoughts on this would be most appreciated.

Thanks,
Bob.



had a house that started on and I was fixing pinholes for years.
finally tore out the copper and replaced it w cpvc. should have done
that from the beginning and saved a lot of aggravation. once they
started they kept on springing leaks all over that dam copper. we was
on a well.
  #4   Report Post  
Posted to alt.home.repair
dpb dpb is offline
external usenet poster
 
Posts: 12,595
Default Copper Water Line Gages, And Usage ?

Robert11 wrote:
....
a. What might make a pinhole leake in the middle of a clear run ?
I guess the pinhole can be considered as a corrosion type of breakthrough.

b. How common is something like this is the thinwall Type M tubing ?
What causes ?

c. 35 years ago, was this (Type M) a common Copper gage they used for
household
hot and cold water lines ?

d. Is it still allowed, or the Code prohibits it now all over ?

Any thoughts on this would be most appreciated.

....

Probably was pit from manufacturing process that took that long to
finally break through. While not common, it's not unheard of for a new
section to have a leak initially.

Corrosion pitting is a combination of material and water chemistry. One
possibility is as someone else noted a touching piece of other metal
such as a truss bracket, etc. that can rub or be an electrolysis potential.

M was (and is) pretty common simply for cost -- it takes less Cu to make
thinner wall (obviously) so many contractors used it--particularly
houses built "on spec" rather than on contract where there wasn't a
specific buyer to satisfy or look over the materials.

I know of nothing in the Code that would proscribe it...nor should there
be, really. Even in your case it's been 35 years which ain't too bad
annoying as it is...

--
  #5   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 102
Default Copper Water Line Gages, And Usage ?

On Aug 13, 7:42 am, "Robert11" wrote:
Hello,

Live in a 35 year old house outside of Boston.

Had a leak in a Copper water pipe that the plumber finally found.

Unfortunately, I forgot to ask him if it was in a hot or cold line, as this
might, perhaps, be meaningful ?

Anyway, what surprised me was that it was pinhole leak in the middle of a
run.
Not at a joint or fitting, etc. Right in the middle of a line.

Apparently they used the thinnest Copper they could find when they built the
place.
I used a caliper on it, and found it to be 0.028, which I guess is a grade M
(outside diameter of 5/8 inch)

But, it still should take the household pressure without any problem, I
would think.
True ?

The plumber replaced it with heavier wall stuff of approx. 0.038, which is
probably
Type L

Questions:

a. What might make a pinhole leake in the middle of a clear run ?
I guess the pinhole can be considered as a corrosion type of breakthrough.

b. How common is something like this is the thinwall Type M tubing ?
What causes ?

c. 35 years ago, was this (Type M) a common Copper gage they used for
household
hot and cold water lines ?

d. Is it still allowed, or the Code prohibits it now all over ?

Any thoughts on this would be most appreciated.

Thanks,
Bob.


This happened in my parents' house. Pinhole, middle of a run, no
damage or anything. At least decades old. Luckily all the plumbing in
the house is exposed so it was easy to spot (middle of the kitchen
ceiling) and fix. (Why don't we do it like that now?

So this is a normal failure mode. Why that spot? ... a tiny inclusion
of foreign material when the pipe was made; a scratch from the
plumber's watch fob; cosmic ray. Unknowable.

I'm pretty sure M and L are both ok by most codes for residential use
in the U.S. and Canada. One pinhole in 35 years is considered
tolerable. It's up to you to ask for the better stuff if your budget
allows.

Chip C
Toronto


  #6   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 6,199
Default Copper Water Line Gages, And Usage ?

On Aug 13, 7:19�pm, "Ralph Mowery" wrote:
"Bob" wrote in message

...

Robert11 wrote:
Hello,


had a house that started on and I was fixing pinholes for years. finally
tore out the copper and replaced it w cpvc. �should have done that from
the beginning and saved a lot of aggravation. �once they started they kept
on springing leaks all over that dam copper. �we was on a well.


One leak is not bad, but I had the same thing hapen to a 35 year old house I
had. �After about 3 leaks and then spending a lot of time under the house
trying to get the leaks stopped (fix one, another place would start) I had
it replaced with the Pex (or whatever) plastic pipe.


The OP shouldnt panic, a single leak in 35 years is nothing to get
upset about, perhaps a previous owner hung a picture there and
happened to damage the line.

now if more leaks occur then its ime for PEX.
  #7   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 4,228
Default Copper Water Line Gages, And Usage ?


"Bob" wrote in message
...
Robert11 wrote:
Hello,


had a house that started on and I was fixing pinholes for years. finally
tore out the copper and replaced it w cpvc. should have done that from
the beginning and saved a lot of aggravation. once they started they kept
on springing leaks all over that dam copper. we was on a well.


One leak is not bad, but I had the same thing hapen to a 35 year old house I
had. After about 3 leaks and then spending a lot of time under the house
trying to get the leaks stopped (fix one, another place would start) I had
it replaced with the Pex (or whatever) plastic pipe.


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
using existing 3/8" flex copper line for fridge ice/water Mikepier Home Repair 3 November 22nd 07 03:39 PM
Insulating A/C copper line outside RichK Home Repair 8 June 17th 07 06:04 PM
Re-line a copper kettle? [email protected] Metalworking 2 May 28th 06 07:44 PM
Brief bad smell from new copper water line Wayne Whitney Home Repair 3 March 12th 06 12:20 AM


All times are GMT +1. The time now is 01:06 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"