I read through tons of the posts on this group, but none addressed my
specific issue. Hopefully, someone can help me figure out how to install my two new digital thermometers. (Lux ATX1500's) Anyway, the problem stems from the fact that I am replacing very old mercury Flair thermostat that has three wires connected to numbers, not letters. Therefore, I don't know how they correspond to the new thermostat. The Flair's are wired as follows: White - #6 Red - #5 Green - #4 I connected the white to RH, which came pre-jumpered to RC on the Lux. Green went to W and Red to Y. While the heat came on, it went up to 80 degrees and didn't come down as I had timed it to. I'm obviously screwing something up.(I've tried several other combinations with the same result) It's a heating only system, and I obviously don't have the cooling mechanism wired correctly. (and maybe more) The documentation doesn't help, and I can't find a thing on the Internet on Flair thermostats. Any help would be greatly appreciated. Thanks! - Adam |
#2
![]()
Posted to alt.home.repair
|
|||
|
|||
![]()
RH is the power in for the heat side (RC is power in for the cool side, but
you don't need it with a heat-only system) W is the "call for heat" terminal Y is the A/C compressor terminal, you shouldn't be using it. G is the "blower on" terminal. Assuming your furnace is wired with standard colors, I'd try Red to 'R', white to 'W' and green to 'G' -Tim "AB" wrote in message ps.com... I read through tons of the posts on this group, but none addressed my specific issue. Hopefully, someone can help me figure out how to install my two new digital thermometers. (Lux ATX1500's) Anyway, the problem stems from the fact that I am replacing very old mercury Flair thermostat that has three wires connected to numbers, not letters. Therefore, I don't know how they correspond to the new thermostat. The Flair's are wired as follows: White - #6 Red - #5 Green - #4 I connected the white to RH, which came pre-jumpered to RC on the Lux. Green went to W and Red to Y. While the heat came on, it went up to 80 degrees and didn't come down as I had timed it to. I'm obviously screwing something up.(I've tried several other combinations with the same result) It's a heating only system, and I obviously don't have the cooling mechanism wired correctly. (and maybe more) The documentation doesn't help, and I can't find a thing on the Internet on Flair thermostats. Any help would be greatly appreciated. Thanks! - Adam |
#3
![]()
Posted to alt.home.repair
|
|||
|
|||
![]()
On 26 Oct 2006 19:56:27 -0700, "AB" wrote:
I read through tons of the posts on this group, but none addressed my specific issue. Hopefully, someone can help me figure out how to install my two new digital thermometers. (Lux ATX1500's) Anyway, the problem stems from the fact that I am replacing very old mercury Flair thermostat that has three wires connected to numbers, not letters. Therefore, I don't know how they correspond to the new thermostat. The Flair's are wired as follows: White - #6 Red - #5 Green - #4 I connected the white to RH, which came pre-jumpered to RC on the Lux. Green went to W and Red to Y. While the heat came on, it went up to 80 degrees and didn't come down as I had timed it to. I'm obviously screwing something up.(I've tried several other combinations with the same result) It's a heating only system, and I obviously don't have the cooling mechanism wired correctly. (and maybe more) The documentation doesn't help, and I can't find a thing on the Internet on Flair thermostats. Any help would be greatly appreciated. Thanks! - Adam If those are the flair zone valves I think they are your new stat isn't going to work with them. you need to call a pro to check the system for you. I can't see what you have from here ![]() |
#4
![]()
Posted to alt.home.repair
|
|||
|
|||
![]()
Thanks. I had a feeling that the damn thing was compatible. There's $80
down the drain!(anyone want to buy two brand new Lux ATX 1500 digital thermostats?) Looks like I'm headed to Ebay. HVACTECH2 wrote: On 26 Oct 2006 19:56:27 -0700, "AB" wrote: I read through tons of the posts on this group, but none addressed my specific issue. Hopefully, someone can help me figure out how to install my two new digital thermometers. (Lux ATX1500's) Anyway, the problem stems from the fact that I am replacing very old mercury Flair thermostat that has three wires connected to numbers, not letters. Therefore, I don't know how they correspond to the new thermostat. The Flair's are wired as follows: White - #6 Red - #5 Green - #4 I connected the white to RH, which came pre-jumpered to RC on the Lux. Green went to W and Red to Y. While the heat came on, it went up to 80 degrees and didn't come down as I had timed it to. I'm obviously screwing something up.(I've tried several other combinations with the same result) It's a heating only system, and I obviously don't have the cooling mechanism wired correctly. (and maybe more) The documentation doesn't help, and I can't find a thing on the Internet on Flair thermostats. Any help would be greatly appreciated. Thanks! - Adam If those are the flair zone valves I think they are your new stat isn't going to work with them. you need to call a pro to check the system for you. I can't see what you have from here ![]() |
#5
![]()
Posted to alt.home.repair
|
|||
|
|||
![]()
Thus spake AB:
Thanks. I had a feeling that the damn thing was compatible. There's $80 down the drain!(anyone want to buy two brand new Lux ATX 1500 digital thermostats?) Looks like I'm headed to Ebay. Try Tim's suggestion before sending it to e-Bay: Assuming your furnace is wired with standard colors, I'd try Red to 'R', white to 'W' and green to 'G' -- DaveC This is an invalid return address Please reply in the news group |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Thermostat wiring question (Heil heatpump and White-Rodgers stat) | Home Repair | |||
To anyone sick of alt.hvac | Home Repair | |||
Troubleshooting new digital thermostat: no heat! | Home Repair | |||
Water heater thermostat "vacation" setting question | Home Repair | |||
Looking for Programable Digital Thermostat w/ short remote probe | Electronics Repair |