Kitchen Vent / Roof Issues
I want to add a roof type kitchen vent. I have a GE NoiseMaker microwave
mounted on top of my gas cooking range. It can vent out. I have decided to put in ducting going out through the sheetrock ceiling and then out of the roof. Two holes have to be made: 6inch round duct beng used. 1. 6inch hole in the sheet rock ceiling. (piece of cake .. easy) 2. a hole in the roof directly (about 10 feet) above the ceiling. Roof is 5/8ich plywood with roofing felt with standard 3-tab asphalt shingles. Here a vent has to be installed with damper. Can anyone provide some tips for the 2nd step to prevent leaking after the vent is installed. Any links to good damper and flashing systems. Any instruction of how to cut the shngles and any overlapping methods for the flashing on the vent. Any glues and caulks? THis vill be done by a contractor.. he is good but he does not have experience with cutting through the roof and making a vent hole or hanlding shingles. But with enough care and reading I am sure we can do it. Its hard to find contractors here that will just handle this as oppsed to redoing the wole kitchen. Any help appreciated!! |
#2
Posted to alt.home.repair
|
|||
|
|||
Kitchen Vent / Roof Issues
"PHPguy" wrote in message ... I want to add a roof type kitchen vent. I have a GE NoiseMaker microwave mounted on top of my gas cooking range. It can vent out. I have decided to put in ducting going out through the sheetrock ceiling and then out of the roof. Two holes have to be made: 6inch round duct beng used. 1. 6inch hole in the sheet rock ceiling. (piece of cake .. easy) 2. a hole in the roof directly (about 10 feet) above the ceiling. Roof is 5/8ich plywood with roofing felt with standard 3-tab asphalt shingles. Here a vent has to be installed with damper. Can anyone provide some tips for the 2nd step to prevent leaking after the vent is installed. Any links to good damper and flashing systems. Any instruction of how to cut the shngles and any overlapping methods for the flashing on the vent. Any glues and caulks? THis vill be done by a contractor.. he is good but he does not have experience with cutting through the roof and making a vent hole or hanlding shingles. But with enough care and reading I am sure we can do it. Its hard to find contractors here that will just handle this as oppsed to redoing the wole kitchen. Any help appreciated!! I have waited until the roof was warm and then gently pried up the shingles that will not be removed. Cut the hole and tar liberally. I have a sheet metal guy that makes flashings that slide over the pipe. Like a big roof jack. Tar liberally. Depending on where this goes through the roof a upstream flashing might be a good idea. I once installed 8 ceiling fans through a friends flat roof. I had refused to do the job unit he was ready to do a re-roof. 4 leaked 4 did not. Best part was one that leaked was on his side of the bed. His wife and I got a kick out of that. |
#3
Posted to alt.home.repair
|
|||
|
|||
Kitchen Vent / Roof Issues
"SQLit" wrote in message ... "PHPguy" wrote in message ... I want to add a roof type kitchen vent. I have a GE NoiseMaker microwave mounted on top of my gas cooking range. It can vent out. I have decided to put in ducting going out through the sheetrock ceiling and then out of the roof. Two holes have to be made: 6inch round duct beng used. 1. 6inch hole in the sheet rock ceiling. (piece of cake .. easy) 2. a hole in the roof directly (about 10 feet) above the ceiling. Roof is 5/8ich plywood with roofing felt with standard 3-tab asphalt shingles. Here a vent has to be installed with damper. Can anyone provide some tips for the 2nd step to prevent leaking after the vent is installed. Any links to good damper and flashing systems. Any instruction of how to cut the shngles and any overlapping methods for the flashing on the vent. Any glues and caulks? THis vill be done by a contractor.. he is good but he does not have experience with cutting through the roof and making a vent hole or hanlding shingles. But with enough care and reading I am sure we can do it. Its hard to find contractors here that will just handle this as oppsed to redoing the wole kitchen. Any help appreciated!! I have waited until the roof was warm and then gently pried up the shingles that will not be removed. Cut the hole and tar liberally. I have a sheet metal guy that makes flashings that slide over the pipe. Like a big roof jack. Tar liberally. Depending on where this goes through the roof a upstream flashing might be a good idea. I once installed 8 ceiling fans through a friends flat roof. I had refused to do the job unit he was ready to do a re-roof. 4 leaked 4 did not. Best part was one that leaked was on his side of the bed. His wife and I got a kick out of that. Silicone caulk, silicone caulk and more silicone caulk. |
#4
Posted to alt.home.repair
|
|||
|
|||
Kitchen Vent / Roof Issues
"PHPguy" wrote in message ... I want to add a roof type kitchen vent. I have a GE NoiseMaker microwave mounted on top of my gas cooking range. It can vent out. I have decided to put in ducting going out through the sheetrock ceiling and then out of the roof. Two holes have to be made: 6inch round duct beng used. 1. 6inch hole in the sheet rock ceiling. (piece of cake .. easy) 2. a hole in the roof directly (about 10 feet) above the ceiling. Roof is 5/8ich plywood with roofing felt with standard 3-tab asphalt shingles. Here a vent has to be installed with damper. Can anyone provide some tips for the 2nd step to prevent leaking after the vent is installed. Any links to good damper and flashing systems. Any instruction of how to cut the shngles and any overlapping methods for the flashing on the vent. Any glues and caulks? THis vill be done by a contractor.. he is good but he does not have experience with cutting through the roof and making a vent hole or hanlding shingles. But with enough care and reading I am sure we can do it. Its hard to find contractors here that will just handle this as oppsed to redoing the wole kitchen. Any help appreciated!! It not that hard of a job any decent roofer can make the penetration water tight. Think about it they Roof around vents every day. The other option if its a outside wall go out the wall don't even go threw the roof. You just need a seat metal guy to make you a eyebrow.They could the install most likely |
#6
Posted to alt.home.repair
|
|||
|
|||
Kitchen Vent / Roof Issues
On Sun, 18 Dec 2005 11:36:22 -0500, PHPguy wrote:
I want to add a roof type kitchen vent. I have a GE NoiseMaker microwave "Noisemaker"? You're kidding, right? 2. a hole in the roof directly (about 10 feet) above the ceiling. Roof is 5/8ich plywood with roofing felt with standard 3-tab asphalt shingles. Here a vent has to be installed with damper. Can anyone provide some tips for the 2nd step to prevent leaking after the vent is installed. Any links to good damper and flashing systems. Any instruction of how to cut the shngles and any overlapping methods for the flashing on the vent. Any glues and caulks? When I put in my roof fan, I followed the instructions that came with it. It said to cut a hole in the shingles and paper and drill a hole in the plywood, and gave a template, the same template for each cut, bigger than the hole you would need. Then it had me take the fan, with housing and flashing attached, and slide it up under the shingles that were above the center line of the fan. (I guess I had to take out a couple roofing nails. The lower half of the fan went atop the shingles, and I suppose I put in a few roofing nails and covered the heads with "black tar" caulk. Maybe I caulked beside the edges as well. Now I do have some mist on the floor in the attic when it rains, but you won't. I have mist when the rain hits the roof and bounces into the screen that is part of the fan housing. Some of it goes through the holes, or hits the screen and part of that splatters inside. It' s barely moist inside. But you won't have a screen. I can't find the instructions right now, but I would just see what fans for sale in the store now say. THis vill be done by a contractor.. he is good but he does not have experience with cutting through the roof and making a vent hole or hanlding shingles. But with enough care and reading I am sure we can do it. Its hard to find contractors here that will just handle this as oppsed to redoing the wole kitchen. Any help appreciated!! Remove NOPSAM to email me. Please let me know if you have posted also. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Under Kitchen Cabinet Lighting . Space Issues? | Home Repair | |||
Vent that does not need to go thru the roof? | Home Repair | |||
3 Bathroom Vents - One Roof Vent | Home Repair | |||
Pitch and gravel roof? | UK diy | |||
Pitch and gravel roof? | Home Repair |