Home Repair (alt.home.repair) For all homeowners and DIYers with many experienced tradesmen. Solve your toughest home fix-it problems.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Mike O'Donnell
 
Posts: n/a
Default Run romex along side heading duct?

I'm planning to run two new 15 amp circuits from the basement up to the
second floor of our 36 year old house. These will be used for general
outlets and a future whole house fan. I've found a first floor wall I can
run it through, but the space between the studs currently has a metal
heating duct in it. There is enough space next to the duct, but is it
acceptable (and safe) to run standard romex along side a residential, forced
air heating duct? The wire wouldn't be attached to the duct, but it would
be within an inch or two, and probably touching it in several places. I
wouldn't think the temp would be a problem; it would be nowhere near the 90C
temp rating of the wire, but I wasn't sure if there might be any long term
effects on the wire. It would be along side it for about 10 feet.



Just to make it clear, I am NOT talking about running it inside the duct.



Any information would be appreciated.



Mike O.


  #2   Report Post  
RBM
 
Posts: n/a
Default

you're perfectly fine as long as your not inside the plenum
"Mike O'Donnell" wrote in message
t...
I'm planning to run two new 15 amp circuits from the basement up to the
second floor of our 36 year old house. These will be used for general
outlets and a future whole house fan. I've found a first floor wall I can
run it through, but the space between the studs currently has a metal
heating duct in it. There is enough space next to the duct, but is it
acceptable (and safe) to run standard romex along side a residential,
forced air heating duct? The wire wouldn't be attached to the duct, but
it would be within an inch or two, and probably touching it in several
places. I wouldn't think the temp would be a problem; it would be nowhere
near the 90C temp rating of the wire, but I wasn't sure if there might be
any long term effects on the wire. It would be along side it for about 10
feet.



Just to make it clear, I am NOT talking about running it inside the duct.



Any information would be appreciated.



Mike O.




  #3   Report Post  
Mike O'Donnell
 
Posts: n/a
Default

Thanks. It's pretty much what I figured, but I just wanted to make sure I'm
not missing something. We just moved in a few years ago and are planning
to stay for a long time, and I didn't want to do something either dangerous,
or it's going to give me problems down the roadl.

- Mike O.

"RBM" rbm2(remove wrote in message
...
you're perfectly fine as long as your not inside the plenum
"Mike O'Donnell" wrote in message
t...
I'm planning to run two new 15 amp circuits from the basement up to the
second floor of our 36 year old house. These will be used for general
outlets and a future whole house fan. I've found a first floor wall I
can run it through, but the space between the studs currently has a metal
heating duct in it. There is enough space next to the duct, but is it
acceptable (and safe) to run standard romex along side a residential,
forced air heating duct? The wire wouldn't be attached to the duct, but
it would be within an inch or two, and probably touching it in several
places. I wouldn't think the temp would be a problem; it would be
nowhere near the 90C temp rating of the wire, but I wasn't sure if there
might be any long term effects on the wire. It would be along side it
for about 10 feet.



Just to make it clear, I am NOT talking about running it inside the duct.



Any information would be appreciated.



Mike O.






  #4   Report Post  
 
Posts: n/a
Default

Dont really see a problem with it, dont it myself. Just keep the wire
as far as possible
away from the duct. (dont want any sharp corners (if any) coming in
contact with the
cable.

Tom

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
hello and a question about water/moisture in ducts anita Home Repair 9 April 8th 05 06:53 PM
Duct For A Gas Dryer ? Robert11 Home Repair 8 March 21st 05 06:00 AM
Lee Valley duct tape: Red Green joke? _firstname_@lr_dot_los-gatos_dot_ca.us Woodworking 39 January 29th 05 05:00 AM
Since I don't have any plans...whatsa best way to secure desk'sback panel to side panels? (and other questions) Bay Area Dave Woodworking 6 August 28th 03 06:02 PM