Home |
Search |
Today's Posts |
![]() |
|
Home Repair (alt.home.repair) For all homeowners and DIYers with many experienced tradesmen. Solve your toughest home fix-it problems. |
|
LinkBack | Thread Tools | Display Modes |
#26
![]() |
|||
|
|||
![]() "Choreboy" wrote in message ... Rudy wrote: A destructive transient cannot be blocked, stopped, or absorbed. Series inductance will stop the transient? Fuse will stop a transient? Does not happen. Numbers provided in the previous post make that woefully obvious. A few years back, there was a lightning storm in the neighborhood. One hit sounded really close aboard and the lights flickered a bit. Couldnt see anything that got damaged but the next day when I went into the den to work on the computer, I smelled something like plastic burning. (BTW, I dont leave my computer "on" when not in use). I tried to power it up but no luck. I looked behind the desk and found my APC surge protector had no green lights on it. I opened up the case and there was a bunch of fried circuits and melted plastic inside. Fortunately, APC warranteed the unit for 5 years so I got a new one for the cost of shipping. I "dont leave home without it" now. Now that I think about it..I'd better get one for my new Big Screen HDTV ASAP !! Rudy I was online when lightning hit a tree 25 feet from my service entrance. My phone service went dead due to a blown fuse on the telephone pole, but I had no damage. Like you, I've had good experience, but I wish I could find statistics and I wish I knew how some models are designed to be more reliable than others. Choreboy SOARS book on grounding has some easy text. Try your library. IEEE 519 (I think) says for surge protection you need to do 2 of the 3 zones. One zone is the utility so that is out. Next is the service, next is point of use. So as a user you can protect the service and point of use. I just installed a GE made surge arrestor for my GE service. Just plugs in to the buss and acts like a 2 pole breaker with a green light. http://www.geindustrial.com/cwc/prod...g&lan g=en_US incase your interested, other manufactures make them for their panels as well. I also have point of use protection. Most of the ones made today have protection levels of around 330v. Remember Metal Oxide Varsities are UL tested ONCE. Not twice. I replace all of my point of use stuff every 2 years just before the Monsoons. If your really into it test your grounding at your service. You will need to beg or borrow special equipment for this. Check out http://www.groundtesterstore.com/clamp/aemc3731.php I have used one of these many times. Especially when driving grounds for fall of potential is out of the question. Other companies make them as well. |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Electrical inspector makes up new rules during inspection | Home Repair | |||
Overhead electrical service to a storage shed | Home Repair | |||
Installing Electrical Outlet In Sink Cabinet | Home Repair | |||
Installing Ceiling Fan with Red wire on electrical box. | Home Ownership | |||
Forthcoming Building Regulations on electrical work (Part P) | UK diy |