Electronics Repair (sci.electronics.repair) Discussion of repairing electronic equipment. Topics include requests for assistance, where to obtain servicing information and parts, techniques for diagnosis and repair, and annecdotes about success, failures and problems.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to alt.home.repair,sci.engr.heat-vent-ac,sci.engr.control,sci.electronics.repair
external usenet poster
 
Posts: 350
Default Humidity Detecting Switch

I've seen $250 humidity detecting fans (Broan?). I have a timer on my bath
fans, and motion detectors on my hallway lights (installed when my dad was
dying), so I can't believe they can't make a wall switch which detects
humidity. ANyone see one? Couldn't find one with google. Besides the
bathrooms, I'd wonder if I can't have one for the house when I'm away and
don't want to have the heat or cool on just to prevent mildew. I hadn't used
cooling in years and the upstairs duct perspired onto my ceiling.

- = -
Vasos Panagiotopoulos, Columbia'81+, Reagan, Mozart, Pindus, BioStrategist
http://www.panix.com/~vjp2/vasos.htm http://www.facebook.com/vasjpan2
---{Nothing herein constitutes advice. Everything fully disclaimed.}---
[Homeland Security means private firearms not lazy obstructive guards]
[Urb sprawl confounds terror] [Phooey on GUI: Windows for subprime Bimbos]

  #5   Report Post  
Posted to alt.home.repair,sci.engr.heat-vent-ac,sci.engr.control,sci.electronics.repair
external usenet poster
 
Posts: 4,926
Default Humidity Detecting Switch

On Jun 10, 7:15*am, wrote:
I've seen $250 humidity detecting fans (Broan?). I have a timer on my bath
fans, and motion detectors on my hallway lights (installed when my dad was
dying), so I can't believe they can't make a wall switch which detects
humidity. ANyone see one? Couldn't find one with google. *Besides the
bathrooms, I'd wonder if I can't have one for the house when I'm away and
don't want to have the heat or cool on just to prevent mildew. I hadn't used
cooling in years and the upstairs duct perspired onto my ceiling.

* * * * * * * * * * * * * * * * * * - = -
*Vasos Panagiotopoulos, Columbia'81+, Reagan, Mozart, Pindus, BioStrategist
* *http://www.panix.com/~vjp2/vasos.htm...k.com/vasjpan2
* ---{Nothing herein constitutes advice. *Everything fully disclaimed..}---
* *[Homeland Security means private firearms not lazy obstructive guards]
*[Urb sprawl confounds terror] [Phooey on GUI: Windows for subprime Bimbos]


Mold in a shower is normal and easily killed by laundry bleach, mild
elsewhere is caused by water, either leaks or condensation in winter.
A humidity fan wont fix what you think it will and will trigger on a
rainy day bringing in more humidity.


  #6   Report Post  
Posted to alt.home.repair,sci.engr.heat-vent-ac,sci.engr.control,sci.electronics.repair
external usenet poster
 
Posts: 43,017
Default Humidity Detecting Switch

In article ,
wrote:
I've seen $250 humidity detecting fans (Broan?). I have a timer on my
bath fans, and motion detectors on my hallway lights (installed when my
dad was dying), so I can't believe they can't make a wall switch which
detects humidity. ANyone see one? Couldn't find one with google.
Besides the bathrooms, I'd wonder if I can't have one for the house when
I'm away and don't want to have the heat or cool on just to prevent
mildew. I hadn't used cooling in years and the upstairs duct perspired
onto my ceiling.


Google on Humidistat.

--
*Change is inevitable, except from a vending machine*

Dave Plowman London SW
To e-mail, change noise into sound.
  #7   Report Post  
Posted to alt.home.repair,sci.engr.heat-vent-ac,sci.engr.control,sci.electronics.repair
external usenet poster
 
Posts: 350
Default Humidity Detecting Switch


*+-Google on Humidistat.

Thanks!


- = -
Vasos Panagiotopoulos, Columbia'81+, Reagan, Mozart, Pindus, BioStrategist
http://www.panix.com/~vjp2/vasos.htm http://www.facebook.com/vasjpan2
---{Nothing herein constitutes advice. Everything fully disclaimed.}---
[Homeland Security means private firearms not lazy obstructive guards]
[Urb sprawl confounds terror] [Phooey on GUI: Windows for subprime Bimbos]



  #9   Report Post  
Posted to alt.home.repair,sci.engr.heat-vent-ac,sci.engr.control,sci.electronics.repair
external usenet poster
 
Posts: 14,845
Default Humidity Detecting Switch

On Jun 10, 8:15*am, wrote:
I've seen $250 humidity detecting fans (Broan?). I have a timer on my bath
fans, and motion detectors on my hallway lights (installed when my dad was
dying), so I can't believe they can't make a wall switch which detects
humidity. ANyone see one? Couldn't find one with google. *Besides the
bathrooms, I'd wonder if I can't have one for the house when I'm away and
don't want to have the heat or cool on just to prevent mildew. I hadn't used
cooling in years and the upstairs duct perspired onto my ceiling.

* * * * * * * * * * * * * * * * * * - = -
*Vasos Panagiotopoulos, Columbia'81+, Reagan, Mozart, Pindus, BioStrategist
* *http://www.panix.com/~vjp2/vasos.htm...k.com/vasjpan2
* ---{Nothing herein constitutes advice. *Everything fully disclaimed..}---
* *[Homeland Security means private firearms not lazy obstructive guards]
*[Urb sprawl confounds terror] [Phooey on GUI: Windows for subprime Bimbos]


Order this one:

http://www.ontimemall.com/nortec-115...midistat..html

It's on sale for $930 but you won't have to spend $250 on a new fan.
  #10   Report Post  
Posted to alt.home.repair,sci.engr.heat-vent-ac,sci.engr.control,sci.electronics.repair
external usenet poster
 
Posts: 350
Default Humidity Detecting Switch

Understood. Most of my mold problems are nowhere near the shower.
(Pointing, siding shingles and duct perspiration might be implicated.) When
my mom was alive, we never had mold in the house. After my dad also died, it
blossomed. I stopped using heat and cool because I essentially "borrowed" it
form my godparents upstairs. I had by heat at 57F and cool at 87F and it
almost never turned on. I also kept the rooms locked up because I was rarely
home.

In fact, I have learned over the past six months, when I sudeenly found
myself spending more time working from home, to push the temperature duing
rain so as to trigger more ventillation.

I live where the East and FLushing rivers empty into Long Island sound,
and I am at 45ft elevation on a hill that peaks at 150, but zero elevation is
on the other side of my block, probably swamp landfill. Last year, was
especially humid, our local beaches were closed, dark green from storm drain
overflow.

*+-Mold in a shower is normal and easily killed by laundry bleach, mild
*+-elsewhere is caused by water, either leaks or condensation in winter.
*+-A humidity fan wont fix what you think it will and will trigger on a
*+-rainy day bringing in more humidity.



- = -
Vasos Panagiotopoulos, Columbia'81+, Reagan, Mozart, Pindus, BioStrategist
http://www.panix.com/~vjp2/vasos.htm http://www.facebook.com/vasjpan2
---{Nothing herein constitutes advice. Everything fully disclaimed.}---
[Homeland Security means private firearms not lazy obstructive guards]
[Urb sprawl confounds terror] [Phooey on GUI: Windows for subprime Bimbos]





  #11   Report Post  
Posted to alt.home.repair,sci.engr.heat-vent-ac,sci.engr.control,sci.electronics.repair
external usenet poster
 
Posts: 350
Default Humidity Detecting Switch

way cool!



- = -
Vasos Panagiotopoulos, Columbia'81+, Reagan, Mozart, Pindus, BioStrategist
http://www.panix.com/~vjp2/vasos.htm http://www.facebook.com/vasjpan2
---{Nothing herein constitutes advice. Everything fully disclaimed.}---
[Homeland Security means private firearms not lazy obstructive guards]
[Urb sprawl confounds terror] [Phooey on GUI: Windows for subprime Bimbos]



  #12   Report Post  
Posted to alt.home.repair,sci.engr.heat-vent-ac,sci.engr.control,sci.electronics.repair
external usenet poster
 
Posts: 3,236
Default Humidity Detecting Switch

On Jun 10, 7:15*am, wrote:
I've seen $250 humidity detecting fans (Broan?). I have a timer on my bath
fans, and motion detectors on my hallway lights (installed when my dad was
dying), so I can't believe they can't make a wall switch which detects
humidity. ANyone see one? Couldn't find one with google. *Besides the
bathrooms, I'd wonder if I can't have one for the house when I'm away and
don't want to have the heat or cool on just to prevent mildew. I hadn't used
cooling in years and the upstairs duct perspired onto my ceiling.

* * * * * * * * * * * * * * * * * * - = -
*Vasos Panagiotopoulos, Columbia'81+, Reagan, Mozart, Pindus, BioStrategist
* *http://www.panix.com/~vjp2/vasos.htm...k.com/vasjpan2
* ---{Nothing herein constitutes advice. *Everything fully disclaimed..}---
* *[Homeland Security means private firearms not lazy obstructive guards]
*[Urb sprawl confounds terror] [Phooey on GUI: Windows for subprime Bimbos]


Do you ever just run your furnace fan for air circulation, without
heating or cooling. ALso, do you do a lot of cooking to raise the
humidity that high?
  #13   Report Post  
Posted to alt.home.repair,sci.engr.heat-vent-ac,sci.engr.control,sci.electronics.repair
external usenet poster
 
Posts: 48
Default Humidity Detecting Switch

wrote:
I've seen $250 humidity detecting fans (Broan?). I have a timer on my bath
fans, and motion detectors on my hallway lights (installed when my dad was
dying), so I can't believe they can't make a wall switch which detects
humidity. ANyone see one? Couldn't find one with google. Besides the
bathrooms, I'd wonder if I can't have one for the house when I'm away and
don't want to have the heat or cool on just to prevent mildew. I hadn't used
cooling in years and the upstairs duct perspired onto my ceiling.

- = -
Vasos Panagiotopoulos, Columbia'81+, Reagan, Mozart, Pindus, BioStrategist
http://www.panix.com/~vjp2/vasos.htm http://www.facebook.com/vasjpan2
---{Nothing herein constitutes advice. Everything fully disclaimed.}---
[Homeland Security means private firearms not lazy obstructive guards]
[Urb sprawl confounds terror] [Phooey on GUI: Windows for subprime Bimbos]



Try the Granger Company. Dump the home repair NG when posting here if
you want a civil reply.
  #15   Report Post  
Posted to alt.home.repair,sci.engr.heat-vent-ac,sci.engr.control,sci.electronics.repair
external usenet poster
 
Posts: 208
Default Humidity Detecting Switch

On Fri, 11 Jun 2010 10:56:13 -0400, Tony wrote:

wrote:
I've seen $250 humidity detecting fans (Broan?). I have a timer on my bath
fans, and motion detectors on my hallway lights (installed when my dad was
dying), so I can't believe they can't make a wall switch which detects
humidity. ANyone see one? Couldn't find one with google. Besides the
bathrooms, I'd wonder if I can't have one for the house when I'm away and
don't want to have the heat or cool on just to prevent mildew. I hadn't used
cooling in years and the upstairs duct perspired onto my ceiling.


I bought 2 army surplus one years ago, high quality stuff! I used it to
totally rebuild a donut proofing box because none of the original parts
were available. (the donut proofing box circulates warm humid air
around the raw donuts so they rise without drying out). A fan, a
stainless steel container like in a salad bar with a generic water
heating element installed in it, the humidistat, and a larger container
of water to siphon water in the small "boiler". Sorry I can't recall
where I bought them.


To *measure* humidity, the easiest I've found are the HIH-4000 series
from Honeywell. Vout is very nearly linear against percent relative
humidity (a second-order fit improves it a little at the cost of some
computations). Feed it 5 VDC, read with an ADC, simple.

For a setpoint, though, the GE HS12 or HS15 are cheaper. They must be
driven by AC (no DC bias allowed) and the impedance range is over 4
decades, so it is not just a simple ADC hookup. But just to get a trip
point reading would be fairly straightforward.

--
Rich Webb Norfolk, VA


  #16   Report Post  
Posted to alt.home.repair,sci.engr.heat-vent-ac,sci.engr.control,sci.electronics.repair
external usenet poster
 
Posts: 742
Default Humidity Detecting Switch

In article , Tony wrote:
wrote:
I've seen $250 humidity detecting fans (Broan?). I have a timer on my bath
fans, and motion detectors on my hallway lights (installed when my dad was
dying), so I can't believe they can't make a wall switch which detects
humidity. ANyone see one? Couldn't find one with google. Besides the
bathrooms, I'd wonder if I can't have one for the house when I'm away and
don't want to have the heat or cool on just to prevent mildew. I hadn't used
cooling in years and the upstairs duct perspired onto my ceiling.


I bought 2 army surplus one years ago, high quality stuff! I used it to
totally rebuild a donut proofing box because none of the original parts
were available. (the donut proofing box circulates warm humid air
around the raw donuts so they rise without drying out). A fan, a
stainless steel container like in a salad bar with a generic water
heating element installed in it, the humidistat, and a larger container
of water to siphon water in the small "boiler". Sorry I can't recall
where I bought them.


Yes I probably bought the same ones years ago. Wrapped in sealed
bags. I just tried using one in my bathroom.
They are not reliable near the extremes. You cannot set it to 80 % hummidity.
The horse hair mechanism is too critical up there. I was able to set it
to about 60%, and one rainy day it just came on. i mounted it uo in the air
box which I had taken out the fan and used an in-line fan for noise control.Its
works OK with the Dew Stop condensation sensor,
but I really need more CFM.
Most mechanical sensors have the wrong connection for fan use.

greg
  #17   Report Post  
Posted to alt.home.repair,sci.engr.heat-vent-ac,sci.engr.control,sci.electronics.repair
external usenet poster
 
Posts: 82
Default Humidity Detecting Switch

In my opinion you are all wet, at temperature you have outline Humidistat
would be useless unless you have Dehumidifier run at all times,
and at 57 Deg. F not likely that you will get below 50% rh
so all you doing is wasting your time but lots luck.

"Dave Plowman (News)" wrote in message
...
In article ,
wrote:
I've seen $250 humidity detecting fans (Broan?). I have a timer on my
bath fans, and motion detectors on my hallway lights (installed when my
dad was dying), so I can't believe they can't make a wall switch which
detects humidity. ANyone see one? Couldn't find one with google.
Besides the bathrooms, I'd wonder if I can't have one for the house when
I'm away and don't want to have the heat or cool on just to prevent
mildew. I hadn't used cooling in years and the upstairs duct perspired
onto my ceiling.


Google on Humidistat.

--
*Change is inevitable, except from a vending machine*

Dave Plowman London SW
To e-mail, change noise into sound.



  #18   Report Post  
Posted to alt.home.repair,sci.engr.heat-vent-ac,sci.engr.control,sci.electronics.repair
external usenet poster
 
Posts: 21
Default Humidity Detecting Switch

On 6/11/2010 4:01 PM, GregS wrote:

...

Most mechanical sensors have the wrong connection for fan use.


I posted a link to one with a relay that sells for $40. Why won't that do?

Jerry
--
Engineering is the art of making what you want from things you can get.
ŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻ ŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻ
  #19   Report Post  
Posted to alt.home.repair,sci.engr.heat-vent-ac,sci.engr.control,sci.electronics.repair
external usenet poster
 
Posts: 3
Default Humidity Detecting Switch

On Jun 10, 8:15*am, wrote:
I've seen $250 humidity detecting fans (Broan?). I have a timer on my bath
fans, and motion detectors on my hallway lights (installed when my dad was


snip.

I have seen a humidty switch with a central AC theromstat. It was in
an older home. I am not sure if they still offer them. It was either
Broan or Honeywell.

Frank Lardino
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
detecting leaks Slain Home Repair 2 May 27th 07 04:13 PM
detecting lime mortar [email protected] UK diy 3 March 20th 06 08:28 AM
detecting sound Patt Home Repair 5 February 17th 06 07:22 PM
Detecting leaks in DC, how-to Phisherman Woodworking 7 January 14th 05 12:11 PM
Storing wood - inside humidity vs. outside humidity. Brian Phillips Woodworking 2 July 22nd 03 02:20 PM


All times are GMT +1. The time now is 09:40 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright İ2004-2024 DIYbanter.