Electronics Repair (sci.electronics.repair) Discussion of repairing electronic equipment. Topics include requests for assistance, where to obtain servicing information and parts, techniques for diagnosis and repair, and annecdotes about success, failures and problems.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 2
Default Tektronix 2430

Has anyone experienced a "no trigger" condition in a 2430. Scope fails
on diag test 9300 /trigs/repet.
  #2   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 26
Default Tektronix 2430

On 15 Jan., 04:02, Pete wrote:
Has anyone experienced a "no trigger" condition in a 2430. Scope fails
on diag test 9300 /trigs/repet.


one of the Tek specific hybrids has failed. I can't tell you right
now from memory which. But see a 2430 service manual for the repair
procedure and how to loacate the problem.

You might need a spare scope for parts or you can contact e.g. the
parts sources in the web (see other Tektronix postings).

hth,
Andreas

  #3   Report Post  
Posted to sci.electronics.repair
external usenet poster
 
Posts: 17
Default Tektronix 2430

In article , Pete wrote:
Has anyone experienced a "no trigger" condition in a 2430. Scope fails
on diag test 9300 /trigs/repet.


Yes. I have one :-(
Functionally, the trigger on mine is intermittent, sometimes it seems
to work a bit, other times no trigger whatever A or B.

Mine fails 9121 9122 9123 9221 9222 and 9300.
(i.e. A passes, B fails, Rep fails.)
It also sometimes takes hours to run the power-on test at all,
it seems to get stuck in the trigger test (test part 9).

As Andreas says, the service manual gives details on looping
failing tests and scoping what's going on. In my case one can
see the (passing) A test doing its "binary search" converging
to the correct trigger level, for both directions.
When running B however the result of every step goes the same
way, no convergence. The inputs to U370 look right to me, the
output on pin 63 wrong.

Interestingly, I found a solder whisker short under the U370
socket (pins 14-15) but removing it didn't help. :-(
Pin 14 is not shown on the schematic, so I assume it's unused.

I suspect U370, but haven't laid my hands on a replcement to
try. (Is there anyone out there near Southampton with a working
2430, willing to do a test swap of U370 and/or U150? :-)

Take care to get adequate cooling if running with the case
off. There are stories of people cooking the hybrid modules
on the main board.

Regards,
Mike.

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Tektronix TDS210 gorehound Electronics Repair 4 September 10th 06 06:09 AM
Tektronix 2430 digital scope errors Andy Cuffe Electronics Repair 3 December 10th 04 06:43 AM
Tektronix 442 pot 20k Arnold Electronics Repair 1 July 27th 04 12:52 AM
Tektronix TDS 540 and options Artem Belevich Electronics Repair 0 July 1st 04 08:24 AM
Sanyo cordless phone CLT-2430: Talk button problems Sylvain Gregoire Electronics Repair 8 September 28th 03 03:41 PM


All times are GMT +1. The time now is 07:28 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"