This could be a really stupid, obvious question, but.....

I have currently got the heating drained down to remove a couple of rads.

Can the combi still be used (safely) for hot water?

Or does draining the heating drain the primary circuit which heats the hot
water?

It's an Ocean Style FF, btw. (Destined for replacement as soon as I can
get around to it....)


thanks
Richard


--
Richard Sampson

email me at
richard at olifant d-ot co do-t uk


  #2   Report Post  
BillR
 
Posts: n/a
Default Can a combi safely be used for DHW with the heating drained?

RichardS wrote:
This could be a really stupid, obvious question, but.....

I have currently got the heating drained down to remove a couple of
rads.

Can the combi still be used (safely) for hot water?

Or does draining the heating drain the primary circuit which heats
the hot water?

It most likely will not even run in this mode... so it will be safe :-)


  #3   Report Post  
RichardS
 
Posts: n/a
Default Can a combi safely be used for DHW with the heating drained?

"BillR" wrote in message
...
RichardS wrote:
This could be a really stupid, obvious question, but.....

I have currently got the heating drained down to remove a couple of
rads.

Can the combi still be used (safely) for hot water?

Or does draining the heating drain the primary circuit which heats
the hot water?

It most likely will not even run in this mode... so it will be safe :-)



Hmmm. it fired up when the missus marched in and promptly turned the
kitchen hot tap on 30 seconds after being told that the heating was drained
down and that we shouldn't use the hot water until I got a definitive answer
or finished the job....

--
Richard Sampson

email me at
richard at olifant d-ot co do-t uk


  #4   Report Post  
BillR
 
Posts: n/a
Default Can a combi safely be used for DHW with the heating drained?

RichardS wrote:
"BillR" wrote in message
...
RichardS wrote:
This could be a really stupid, obvious question, but.....

I have currently got the heating drained down to remove a couple of
rads.

Can the combi still be used (safely) for hot water?

Or does draining the heating drain the primary circuit which heats
the hot water?

It most likely will not even run in this mode... so it will be safe
:-)



Hmmm. it fired up when the missus marched in and promptly turned the
kitchen hot tap on 30 seconds after being told that the heating was
drained down and that we shouldn't use the hot water until I got a
definitive answer or finished the job....


The two combis that I've fitted specifically said in the instructions that
they would not run if there was no pressure in the CH circuit...
To test a combi boiler without rad a loop of a few metres of pipe is often
used.


  #5   Report Post  
geoff
 
Posts: n/a
Default Can a combi safely be used for DHW with the heating drained?

In message , RichardS
writes


This could be a really stupid, obvious question, but.....

I have currently got the heating drained down to remove a couple of rads.

Can the combi still be used (safely) for hot water?

Or does draining the heating drain the primary circuit which heats the hot
water?


Yes, and there is normally a water pressure switch which won't allow the
boiler to fire up if the pressure is too low


It's an Ocean Style FF, btw. (Destined for replacement as soon as I can
get around to it....)

If you tell me exactly what boiler, I can go and check the manual

email me offlist, I have the manuals on a computer here at home
--
geoff


  #6   Report Post  
Ed Sirett
 
Posts: n/a
Default Can a combi safely be used for DHW with the heating drained?

On Tue, 06 Jan 2004 20:25:01 +0000, BillR wrote:

RichardS wrote:
"BillR" wrote in message
...
RichardS wrote:
This could be a really stupid, obvious question, but.....

I have currently got the heating drained down to remove a couple of
rads.

Can the combi still be used (safely) for hot water?

Or does draining the heating drain the primary circuit which heats
the hot water?

It most likely will not even run in this mode... so it will be safe
:-)



Hmmm. it fired up when the missus marched in and promptly turned the
kitchen hot tap on 30 seconds after being told that the heating was
drained down and that we shouldn't use the hot water until I got a
definitive answer or finished the job....


The two combis that I've fitted specifically said in the instructions that
they would not run if there was no pressure in the CH circuit...
To test a combi boiler without rad a loop of a few metres of pipe is often
used.


If the boiler has isolating valves on the primary connections you may well
get away with it provided the boiler is still filled and pressured.
If the loop is external it will be difficult to fill it.
Also the manufacturers may rely on the promary circuit being connected to
dump excess heat into after DHW mode.


--
Ed Sirett - Property maintainer and registered gas fitter.
The FAQ for uk.diy is at www.diyfaq.org.uk
Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html
Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html


  #7   Report Post  
RichardS
 
Posts: n/a
Default Can a combi safely be used for DHW with the heating drained?

"RichardS" noaccess@invalid wrote in message
. ..


This could be a really stupid, obvious question, but.....

I have currently got the heating drained down to remove a couple of rads.

Can the combi still be used (safely) for hot water?

Or does draining the heating drain the primary circuit which heats the hot
water?

It's an Ocean Style FF, btw. (Destined for replacement as soon as I can
get around to it....)


Thanks, Bill, Ed, Geoff

All back and working now, so the question of DHW doesn't arise tomorrow
morning....

It seems that the boiler firing up when SWMBO turned the hot tap on might
have been a momentary fluke due to some wierd pressurisation in the vicinity
of the pressure switch. It didn't do it again (I was curious).

At 11:30 PM when I have just managed to dislodge the compression joint on
one of the lockshields, I find myself very glad that I stopped, scratched my
head, and thought "yes, better get some just in case" when passing the 15mm
olive section of wherever I was 3 years ago!

The room ought to be a little warmer now that there is some skirting board
on the radiator wall - there were 2 air bricks that were 1/3rd above floor
level and venting straight into the room....

--
Richard Sampson

email me at
richard at olifant d-ot co do-t uk


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Combi Boiler - water heating then cuts out P Lavers UK diy 7 December 2nd 14 07:44 PM
designing a central heating and hotwater system duncan UK diy 96 November 28th 05 01:32 PM
Baxi Combi - Hot Water Whining Chris M UK diy 0 October 28th 03 08:29 PM
Pool water in central heating system Andy Hall UK diy 1 September 2nd 03 05:01 PM
Underfloor heating SC UK diy 112 August 27th 03 02:12 PM


All times are GMT +1. The time now is 05:49 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"