  #1   Report Post  
Junior Member
 
Posts: 1
Default Blown fuse

I have a New World Stowaway 411/1 back boiler which was in our house when we bought it 30 years ago, up until Sunday we had not had a single problem with it. On Sunday the 1 amp boiler fuse blew and at the moment we have neither heating nor hot water. I have tried everywhere to get a replacement fuse but have been told that the boiler is now obsolete. The fuse is bigger than today's fuses therefore I wondering if anyone has an idea where I would possibly get a replacement, if anywhere. Any ideas? Thanks
  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 9,560
Default Blown fuse

On Tuesday, February 24, 2015 at 8:17:03 PM UTC, Terryokeefe wrote:
I have a New World Stowaway 411/1 back boiler which was in our house
when we bought it 30 years ago, up until Sunday we had not had a single
problem with it. On Sunday the 1 amp boiler fuse blew and at the moment
we have neither heating nor hot water. I have tried everywhere to get a
replacement fuse but have been told that the boiler is now obsolete. The
fuse is bigger than today's fuses therefore I wondering if anyone has an
idea where I would possibly get a replacement, if anywhere. Any ideas?
Thanks


If you dont tell us the fuse dims, how would we know? Is it by any chance 32mm long glass tubular fuse?


NT
  #3   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 553
Default Blown fuse

Terryokeefe wrote:

I have a New World Stowaway 411/1 back boiler which was in our house
when we bought it 30 years ago, up until Sunday we had not had a single
problem with it. On Sunday the 1 amp boiler fuse blew ...


Wherabouts was this fuse - inside the boiler (where?), or in a control unit,
or what?

Even if you replace the fuse a bigger problem will be whether it just
disintegrated due to age or if something else in the boiler (or a pump or
valve which I assume are physically separate from the boiler itself) expired
and the fuse blew as a consequence. Even if you do the fuse yourself are
you able to diagnose/repair other bits?

--
Jeremy C B Nicoll - my opinions are my own.

Email sent to my from-address will be deleted. Instead, please reply
to replacing "aaa" by "284".
  #4   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 3,155
Default Blown fuse

In article ,
wrote:
On Tuesday, February 24, 2015 at 8:17:03 PM UTC, Terryokeefe wrote:
I have a New World Stowaway 411/1 back boiler which was in our house
when we bought it 30 years ago, up until Sunday we had not had a single
problem with it. On Sunday the 1 amp boiler fuse blew and at the moment
we have neither heating nor hot water. I have tried everywhere to get a
replacement fuse but have been told that the boiler is now obsolete.
The fuse is bigger than today's fuses therefore I wondering if anyone
has an idea where I would possibly get a replacement, if anywhere. Any
ideas? Thanks


If you dont tell us the fuse dims, how would we know? Is it by any chance
32mm long glass tubular fuse?



originally known as 1¼"

--
From KT24 in Surrey

Using a RISC OS computer running v5.18

  #5   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 2,701
Default Blown fuse

On 24/02/2015 20:12, Terryokeefe wrote:

I have a New World Stowaway 411/1 back boiler which was in our house
when we bought it 30 years ago, up until Sunday we had not had a single
problem with it. On Sunday the 1 amp boiler fuse blew and at the moment
we have neither heating nor hot water. I have tried everywhere to get a
replacement fuse but have been told that the boiler is now obsolete. The
fuse is bigger than today's fuses therefore I wondering if anyone has an
idea where I would possibly get a replacement, if anywhere. Any ideas?


If you mentioned some numerical dimensions and a voltage rating it would
be a heck of a lot easier to make some sensible suggestions.

Mind reading is exceptionally difficult over the internet!

Rapidonline would be the first place I looked followed by RS/Farnell.

--
Regards,
Martin Brown


  #6   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 9,560
Default Blown fuse

On Tuesday, February 24, 2015 at 8:19:50 PM UTC, wrote:
On Tuesday, February 24, 2015 at 8:17:03 PM UTC, Terryokeefe wrote:
I have a New World Stowaway 411/1 back boiler which was in our house
when we bought it 30 years ago, up until Sunday we had not had a single
problem with it. On Sunday the 1 amp boiler fuse blew and at the moment
we have neither heating nor hot water. I have tried everywhere to get a
replacement fuse but have been told that the boiler is now obsolete. The
fuse is bigger than today's fuses therefore I wondering if anyone has an
idea where I would possibly get a replacement, if anywhere. Any ideas?
Thanks


If you dont tell us the fuse dims, how would we know? Is it by any chance 32mm long glass tubular fuse?


1A do blow in time for no reason. 3A is the lowest that doesnt.


NT
  #8   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 3,155
Default Blown fuse

In article ,
wrote:
On Tuesday, February 24, 2015 at 8:19:50 PM UTC, wrote:
On Tuesday, February 24, 2015 at 8:17:03 PM UTC, Terryokeefe wrote:
I have a New World Stowaway 411/1 back boiler which was in our house
when we bought it 30 years ago, up until Sunday we had not had a
single problem with it. On Sunday the 1 amp boiler fuse blew and at
the moment we have neither heating nor hot water. I have tried
everywhere to get a replacement fuse but have been told that the
boiler is now obsolete. The fuse is bigger than today's fuses
therefore I wondering if anyone has an idea where I would possibly
get a replacement, if anywhere. Any ideas? Thanks


If you dont tell us the fuse dims, how would we know? Is it by any
chance 32mm long glass tubular fuse?


1A do blow in time for no reason. 3A is the lowest that doesnt.


perhasp the old 1A one was an antisurge one and you arec fitting a "quick
blow". Beside !A written on the cao, are there any other letters?

--
From KT24 in Surrey

Using a RISC OS computer running v5.18

  #9   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 600
Default Blown fuse

Terryokeefe wrote:

I have a New World Stowaway 411/1 back boiler which was in our house
when we bought it 30 years ago, up until Sunday we had not had a single
problem with it. On Sunday the 1 amp boiler fuse blew and at the moment
we have neither heating nor hot water. I have tried everywhere to get a
replacement fuse but have been told that the boiler is now obsolete. The
fuse is bigger than today's fuses therefore I wondering if anyone has an
idea where I would possibly get a replacement, if anywhere. Any ideas?
Thanks

It's probably what I know as a 1.25" fuse, easily available from CPC
and such, or even Maplin possibly.

--
Chris Green
·
  #10   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 2,569
Default Blown fuse

Graham. wrote:

I'm going to have to wash my mouth out with water


That's the best thing for washing things out.

Bill


  #11   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 4,339
Default Blown fuse


"Terryokeefe" wrote in message
...

I have a New World Stowaway 411/1 back boiler which was in our house
when we bought it 30 years ago, up until Sunday we had not had a single
problem with it. On Sunday the 1 amp boiler fuse blew and at the moment
we have neither heating nor hot water. I have tried everywhere to get a
replacement fuse but have been told that the boiler is now obsolete. The
fuse is bigger than today's fuses therefore I wondering if anyone has an
idea where I would possibly get a replacement, if anywhere. Any ideas?
Thanks


If you are absolutely stuck, drill the end caps of the fuse and solder in
some wire.
You can strip down some flex to get a thin copper wire strand.

It is about a five amp rating BTW, so you have to be sure there is no actual
fault in this case.
On the other hand, the damage may already be done.


  #12   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 9,560
Default Blown fuse

On Wednesday, February 25, 2015 at 7:21:48 AM UTC, harry wrote:
"Terryokeefe" wrote in message
...

I have a New World Stowaway 411/1 back boiler which was in our house
when we bought it 30 years ago, up until Sunday we had not had a single
problem with it. On Sunday the 1 amp boiler fuse blew and at the moment
we have neither heating nor hot water. I have tried everywhere to get a
replacement fuse but have been told that the boiler is now obsolete. The
fuse is bigger than today's fuses therefore I wondering if anyone has an
idea where I would possibly get a replacement, if anywhere. Any ideas?
Thanks


If you are absolutely stuck, drill the end caps of the fuse and solder in
some wire.
You can strip down some flex to get a thin copper wire strand.

It is about a five amp rating BTW, so you have to be sure there is no actual
fault in this case.
On the other hand, the damage may already be done.


The OP doesnt know where to get a fuse, or what sort of fuse it is. They're not very likely to ascertain the absence of a fault plus assess the safety of abandoning the 1A fuse and relying on what might or might not be a 5A fuse.

It might well work, or it might trash something or set fire to something.


NT
  #13   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,631
Default Blown fuse

However one needs to suspect it might just be there is a real fault in the
circuit, so don't just buy one.
Are these fuses really obsolete, or is it just from the boiler spares
people?
I'm sure I've noted them inside hi fi equipment of fairly recent vintage as
a last line of defence as it were.

Besides, one could, I imagine fashion something up out of the blown one
with some wire, a normal fuse and some solder.. Ahem.
Brian

--
From the Sofa of Brian Gaff Reply address is active
wrote in message
...
On Tuesday, February 24, 2015 at 8:19:50 PM UTC, wrote:
On Tuesday, February 24, 2015 at 8:17:03 PM UTC, Terryokeefe wrote:
I have a New World Stowaway 411/1 back boiler which was in our house
when we bought it 30 years ago, up until Sunday we had not had a single
problem with it. On Sunday the 1 amp boiler fuse blew and at the moment
we have neither heating nor hot water. I have tried everywhere to get a
replacement fuse but have been told that the boiler is now obsolete.
The
fuse is bigger than today's fuses therefore I wondering if anyone has
an
idea where I would possibly get a replacement, if anywhere. Any ideas?
Thanks


If you dont tell us the fuse dims, how would we know? Is it by any chance
32mm long glass tubular fuse?


1A do blow in time for no reason. 3A is the lowest that doesnt.


NT



  #14   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,389
Default Blown fuse

In message , Brian Gaff
writes
However one needs to suspect it might just be there is a real fault in the
circuit, so don't just buy one.
Are these fuses really obsolete, or is it just from the boiler spares
people?
I'm sure I've noted them inside hi fi equipment of fairly recent vintage as
a last line of defence as it were.


No, I doubt the fuse is obsolete, just that the OP probably didn't know
of the best places to look (cpc, maplins etc.) - though they never said
where 'everywhere' was that they looked.
--
Chris French

  #15   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 630
Default Blown fuse

On Wed, 25 Feb 2015 07:19:57 -0000, "harryagain"
wrote:


"Terryokeefe" wrote in message
...

I have a New World Stowaway 411/1 back boiler which was in our house
when we bought it 30 years ago, up until Sunday we had not had a single
problem with it. On Sunday the 1 amp boiler fuse blew and at the moment
we have neither heating nor hot water. I have tried everywhere to get a
replacement fuse but have been told that the boiler is now obsolete. The
fuse is bigger than today's fuses therefore I wondering if anyone has an
idea where I would possibly get a replacement, if anywhere. Any ideas?
Thanks


If you are absolutely stuck, drill the end caps of the fuse and solder in
some wire.
You can strip down some flex to get a thin copper wire strand.

It is about a five amp rating BTW, so you have to be sure there is no actual
fault in this case.
On the other hand, the damage may already be done.


If the endcaps are not already drilled then heat them with a soldering
iron and flick them off, they are secured with some sort of hot-melt
glue.

Insert a strand of wire into the glass tube and fold over the edge,
then place the endcap back on while heating it with the iron again to
re-melt the glue. Perhaps suprisingly, the wire always makes good
contact.
I must have made hundreds of these "last resort" repairs over the
years.

--

Graham.

%Profound_observation%
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Fuse: fast blown vs slow blown Man-wai Chang Electronics Repair 66 June 4th 11 08:46 PM
Cause of blown fuse. Sjouke Burry[_2_] Electronics Repair 7 August 13th 10 12:27 AM
Have I blown a fuse, or what? [email protected] Home Repair 5 March 10th 08 08:07 PM
Blown fuse R. Gregg Reed Home Repair 45 December 14th 05 12:11 PM
Blown Fuse C Electronics Repair 5 February 7th 05 01:24 AM