Woodworking (rec.woodworking) Discussion forum covering all aspects of working with wood. All levels of expertise are encouraged to particiapte.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 783
Default Cheap labor...

http://www.hudsonvalleysportsman.com...c,16047.0.html

....wonder if they survived?
  #2   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 2,804
Default Cheap labor...

Well, hell, one guy is holding the ladder. Isn't that safe enough?

Used scaffolds, on Craigslist, go for around $50-$80, around here. A used set of 6" or 8" wheels go for about $150. Can't beat that kind of insurance.

Sonny
  #3   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 10,043
Default Cheap labor...

On 5/30/2015 9:38 AM, John Grossbohlin wrote:
http://www.hudsonvalleysportsman.com...c,16047.0.html

...wonder if they survived?


Ever see a cornice crew working on the third story? I close my eyes,
drive off, and don't open them for a block.

See this kind of stuff on construction sites all the time.

One of my favorites:

I always supply one 240v receptacle at the T-pole. Problem is equipment
plugs vary in configuration.

Hell, just clip off the plug, strip the insulation back an inch or two,
and stick the two hot wires straight into the hot leg holes of the
receptacle ... don't need no steenking ground.

No problemo ...

--
eWoodShop: www.eWoodShop.com
Wood Shop: www.e-WoodShop.net
https://www.google.com/+eWoodShop
https://plus.google.com/+KarlCaillouet/posts
http://www.custommade.com/by/ewoodshop/
KarlCaillouet@ (the obvious)
  #4   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 2,559
Default Cheap labor...

Swingman wrote in
:


Ever see a cornice crew working on the third story? I close my eyes,
drive off, and don't open them for a block.


*snip*

That's ok when you're floating down the river that used to be a street. I
was just telling my sister that we've gotten about an inch of rain here but
Houston's gotten a mile. You know the old adage. :-)

Puckdropper
--
Make it to fit, don't make it fit.
  #5   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 3,287
Default Cheap labor...

On Saturday, May 30, 2015 at 10:44:25 AM UTC-5, Swingman wrote:

Ever see a cornice crew working on the third story? I close my eyes,
drive off, and don't open them for a block.

See this kind of stuff on construction sites all the time.


I do too, and it makes me cringe. What could come of these guys possibly be thinking of? I see extension ladders fully extended (talking about the lightweight type) across to step ladders used as a scaffold board constantly..

For that matter, I see broken ladders being used constantly. Missing steps, pieces of 2x4 screwed across the sides to "repair" broken steps, etc.

I recently went by a friend's job to check it out before lunch, and his painter was working on the very top of a 32' extension ladder, fully extended while painting the inside eave of the gable. While touring the jobsite, we walked by the ladder and I couldn't help but feel my rear clinch.

One side of the ladder's last six inches was badly bent and damaged, and the foot didn't make good contact with the ground. To fix that small detail, they put a piece of 1x4 under the foot with some other site debris under it to get that side more balanced.


One of my favorites:

I always supply one 240v receptacle at the T-pole. Problem is equipment
plugs vary in configuration.

Hell, just clip off the plug, strip the insulation back an inch or two,
and stick the two hot wires straight into the hot leg holes of the
receptacle ... don't need no steenking ground.

No problemo ...


Hey...

Back in the time before time, we were MUCH safer than that. I was framing full time and they put a temp pole behind every other house for misc. power needs. We had a big SpeedAire 220V compressor that ran all the guns on the job.

We had a box with a plug to match our compressor's, and the other end was stripped ten gauge wire as you described. We thought we were safer because we used 10ga wire, and carefully flattened the copper ends a bit so they would fit in the temp plug. How stupid was that?

I actually found out just how stupid one misty day when plugging in one hot wire leg and saw it arc, them it blew out the plug on the pole. I wasn't hurt, but felt like I lost about 10 years off my life!

Ahhhh....

to be young,
dumb,
and full of....

stupid.

Robert



  #6   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 161
Default Cheap labor...

On 5/30/2015 11:44 AM, Swingman wrote:
On 5/30/2015 9:38 AM, John Grossbohlin wrote:
http://www.hudsonvalleysportsman.com...c,16047.0.html

...wonder if they survived?


Ever see a cornice crew working on the third story? I close my eyes, drive
off, and don't open them for a block.

See this kind of stuff on construction sites all the time.

One of my favorites:

I always supply one 240v receptacle at the T-pole. Problem is equipment
plugs vary in configuration.

Hell, just clip off the plug, strip the insulation back an inch or two, and
stick the two hot wires straight into the hot leg holes of the receptacle
... don't need no steenking ground.

No problemo ...


Yeah. I had a spray-foam crew come in and do the ceiling in the downstairs
garages before I sheetrocked everything. When they showed up I showed them
where the 240V appliance-style receptacles where in the half that serves as
my shop and told them that they should power up there. I even offered the
use of a spare plug in case theirs weren't compatible. Two receptacles that
power my larger WW equipment were all of 20' from their equipment trailer.
What I found later was that they ran a 100' extension cord around the house
and hot-wired it into the 200A service panel at the far end of the house.
Just the hots--no ground. I wonder if my homeowner's insurance covers fried
workers.
  #7   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 11,640
Default Cheap labor...

On 5/30/2015 10:38 AM, John Grossbohlin wrote:
http://www.hudsonvalleysportsman.com...c,16047.0.html

...wonder if they survived?



Ever see how chimney workers set up ladders? We had guys doing this on
the building where I work

http://www.liveleak.com/view?i=2b5_1...358&comments=1


http://en.wikipedia.org/wiki/Steeple...n_1960_arp.jpg
  #8   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 5,710
Default Cheap labor...

Ed Pawlowski wrote:

On 5/30/2015 10:38 AM, John Grossbohlin wrote:
http://www.hudsonvalleysportsman.com...c,16047.0.html

...wonder if they survived?



Ever see how chimney workers set up ladders? We had guys doing this
on the building where I work

http://www.liveleak.com/view?i=2b5_1...358&comments=1


http://en.wikipedia.org/wiki/Steeple...n_1960_arp.jpg



Geezus - that stuff puckers my butt just watching it on my laptop.

--

-Mike-



  #9   Report Post  
Posted to rec.woodworking
external usenet poster
 
Posts: 12,155
Default Cheap labor...

On 5/30/2015 10:44 AM, Swingman wrote:
On 5/30/2015 9:38 AM, John Grossbohlin wrote:
http://www.hudsonvalleysportsman.com...c,16047.0.html

...wonder if they survived?


Ever see a cornice crew working on the third story? I close my eyes,
drive off, and don't open them for a block.

See this kind of stuff on construction sites all the time.

One of my favorites:

I always supply one 240v receptacle at the T-pole. Problem is equipment
plugs vary in configuration.

Hell, just clip off the plug, strip the insulation back an inch or two,
and stick the two hot wires straight into the hot leg holes of the
receptacle ... don't need no steenking ground.

No problemo ...


I'll never forget the guy that was sanding the floors for Sara's house.
IIRC he used Romex, bare ended, for his the extension cord to his
floor sander. He did practice electrical safety though, the twisted
bare ended splices were pointed in different directions.
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Cheap Volunteer labor [email protected] Metalworking 3 June 14th 15 12:04 PM
Labor Day Guv Bob Home Repair 26 September 5th 14 10:13 PM
O/T: Free Labor Lew Hodgett[_6_] Woodworking 9 June 24th 11 07:12 PM
cheap labor Millwright Ron[_2_] Metalworking 1 March 7th 08 05:02 AM
Labor Cost for .... Mo Thanku UK diy 9 October 16th 04 10:36 PM


All times are GMT +1. The time now is 07:22 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 