Default Prefinished hardwood flooring installation question

As a long time lurker and occasional contributor to this group I
realize this may not be the correct to post this message but I'm going
to do it anyway. :-)

I'm a competent amateur woodworker,
http://bmacgillivray.ott.istop.com/w.../projects.html and
have done my fair share of home renovation projects but I've never
installed hardwood flooring before. I've read up on it on a few web
sites and perused the flooring book from the Borg and in all cases
they suggest runing the flooring strips at right angles to the joists.
Esthetically, this will not work in our house.

The current subfloor is 3/4" osb and is in ok condition. I read
someplace that to install the flooring parallel to the joists an extra
1/2" plywood layer would be a good idea. Is this necessary or is is
overkill?

TIA
BMG
  #2   Report Post  
 
Posts: n/a
Default Prefinished hardwood flooring installation question

On Mon, 10 May 2004 22:35:37 -0400, MacBain
wrote:

As a long time lurker and occasional contributor to this group I
realize this may not be the correct to post this message but I'm going
to do it anyway. :-)

I'm a competent amateur woodworker,
http://bmacgillivray.ott.istop.com/w.../projects.html and
have done my fair share of home renovation projects but I've never
installed hardwood flooring before. I've read up on it on a few web
sites and perused the flooring book from the Borg and in all cases
they suggest runing the flooring strips at right angles to the joists.
Esthetically, this will not work in our house.

The current subfloor is 3/4" osb and is in ok condition. I read
someplace that to install the flooring parallel to the joists an extra
1/2" plywood layer would be a good idea. Is this necessary or is is
overkill?

TIA
BMG




consider a diagonal installation?
  #3   Report Post  
Eric Johnson
 
Posts: n/a
Default Prefinished hardwood flooring installation question

Rule of thumb I was taught is it takes an 1 1/2 inch subfloor to keep
ceramic tile from turning into dust, that said I think that even if you add
the subfloor to build up to 1 1/4 I'm betting the floor would have some
waves in it after some time. Maybe if you had access to the joists
underneath you could add some solid blocking?

EJ


  #4   Report Post  
Mike
 
Posts: n/a
Default Prefinished hardwood flooring installation question


The current subfloor is 3/4" osb and is in ok condition. I read
someplace that to install the flooring parallel to the joists an extra
1/2" plywood layer would be a good idea. Is this necessary or is is
overkill?


OSB is an unsuitable substrate for hardwood floor; doesn't hold the
nails. An additional layer of plywoood is not only a good idea but
necessary. Screwed and glued. 3/4" would be better in your
application. Check the osb for flatness first.

Mike
  #5   Report Post  
rob
 
Posts: n/a
Default Prefinished hardwood flooring installation question

Definitely not overkill. Even if you were installing perpendicular to
the joists, you should probably put down the extra 1/2" plywood. OSB
does not hold nails well and when I was researching installation of
flooring, all the advice I received said I needed at least an extra
1/2" of ply. I installed my pre-fin flooring at a 45 degree angle to
the joists. Other than adding some extra subfloor, the installation of
prefinished floor is a breeze.

-Rob

MacBain wrote in message . ..
As a long time lurker and occasional contributor to this group I
realize this may not be the correct to post this message but I'm going
to do it anyway. :-)

I'm a competent amateur woodworker,
http://bmacgillivray.ott.istop.com/w.../projects.html and
have done my fair share of home renovation projects but I've never
installed hardwood flooring before. I've read up on it on a few web
sites and perused the flooring book from the Borg and in all cases
they suggest runing the flooring strips at right angles to the joists.
Esthetically, this will not work in our house.

The current subfloor is 3/4" osb and is in ok condition. I read
someplace that to install the flooring parallel to the joists an extra
1/2" plywood layer would be a good idea. Is this necessary or is is
overkill?

TIA
BMG



  #6   Report Post  
david
 
Posts: n/a
Default Prefinished hardwood flooring installation question

Look at http://www.nofma.org/installation.htm (NOFMA: The Wood Flooring
Manufacturers Association)

they state that 3/4 OSB is an acceptable subfloor. They dont
specifically say it's ok to go parallel to the joists with that, though.
I think it would be wise to add the plywood if going parallel to the
joists...

david

MacBain wrote:

As a long time lurker and occasional contributor to this group I
realize this may not be the correct to post this message but I'm going
to do it anyway. :-)

I'm a competent amateur woodworker,
http://bmacgillivray.ott.istop.com/w.../projects.html and
have done my fair share of home renovation projects but I've never
installed hardwood flooring before. I've read up on it on a few web
sites and perused the flooring book from the Borg and in all cases
they suggest runing the flooring strips at right angles to the joists.
Esthetically, this will not work in our house.

The current subfloor is 3/4" osb and is in ok condition. I read
someplace that to install the flooring parallel to the joists an extra
1/2" plywood layer would be a good idea. Is this necessary or is is
overkill?

TIA
BMG


  #7   Report Post  
K. B.
 
Posts: n/a
Default Prefinished hardwood flooring installation question

The reason to run perpendicular is for the joist to bear the load. Is it
over kill? Wait until you unload 300 sq.feet of 3/4" flooring and get a
real feel for what is going to weight! We actually stacked some of our wood
flooring boxes PARALLEL to the joists (like your proposed installation) and
the plywood underfloor bowed and flexed! We re stacked perpendicular.
Overkill- no. Architecturally correct- yes.

--
KB

"Eric Johnson" wrote in message
...
Rule of thumb I was taught is it takes an 1 1/2 inch subfloor to keep
ceramic tile from turning into dust, that said I think that even if you

add
the subfloor to build up to 1 1/4 I'm betting the floor would have some
waves in it after some time. Maybe if you had access to the joists
underneath you could add some solid blocking?

EJ





Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
3 phase question, new installation Ivan Vegvary Metalworking 17 July 28th 04 10:23 PM
diy hardwood flooring installation -- feasible? a UK diy 5 December 5th 03 09:45 AM
Oak t&g flooring installation RichardS UK diy 2 July 23rd 03 09:22 AM


All times are GMT +1. The time now is 11:39 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"