MacBain May 11th 04 03:35 AM

Prefinished hardwood flooring installation question
 
As a long time lurker and occasional contributor to this group I
realize this may not be the correct to post this message but I'm going
to do it anyway. :-)

I'm a competent amateur woodworker,
http://bmacgillivray.ott.istop.com/w.../projects.html and
have done my fair share of home renovation projects but I've never
installed hardwood flooring before. I've read up on it on a few web
sites and perused the flooring book from the Borg and in all cases
they suggest runing the flooring strips at right angles to the joists.
Esthetically, this will not work in our house.

The current subfloor is 3/4" osb and is in ok condition. I read
someplace that to install the flooring parallel to the joists an extra
1/2" plywood layer would be a good idea. Is this necessary or is is
overkill?

TIA
BMG

[email protected] May 11th 04 05:38 AM

Prefinished hardwood flooring installation question
 
On Mon, 10 May 2004 22:35:37 -0400, MacBain
wrote:

As a long time lurker and occasional contributor to this group I
realize this may not be the correct to post this message but I'm going
to do it anyway. :-)

I'm a competent amateur woodworker,
http://bmacgillivray.ott.istop.com/w.../projects.html and
have done my fair share of home renovation projects but I've never
installed hardwood flooring before. I've read up on it on a few web
sites and perused the flooring book from the Borg and in all cases
they suggest runing the flooring strips at right angles to the joists.
Esthetically, this will not work in our house.

The current subfloor is 3/4" osb and is in ok condition. I read
someplace that to install the flooring parallel to the joists an extra
1/2" plywood layer would be a good idea. Is this necessary or is is
overkill?

TIA
BMG




consider a diagonal installation?

Eric Johnson May 11th 04 12:58 PM

Prefinished hardwood flooring installation question
 
Rule of thumb I was taught is it takes an 1 1/2 inch subfloor to keep
ceramic tile from turning into dust, that said I think that even if you add
the subfloor to build up to 1 1/4 I'm betting the floor would have some
waves in it after some time. Maybe if you had access to the joists
underneath you could add some solid blocking?

EJ



Mike May 11th 04 03:37 PM

Prefinished hardwood flooring installation question
 

The current subfloor is 3/4" osb and is in ok condition. I read
someplace that to install the flooring parallel to the joists an extra
1/2" plywood layer would be a good idea. Is this necessary or is is
overkill?


OSB is an unsuitable substrate for hardwood floor; doesn't hold the
nails. An additional layer of plywoood is not only a good idea but
necessary. Screwed and glued. 3/4" would be better in your
application. Check the osb for flatness first.

Mike

rob May 11th 04 06:21 PM

Prefinished hardwood flooring installation question
 
Definitely not overkill. Even if you were installing perpendicular to
the joists, you should probably put down the extra 1/2" plywood. OSB
does not hold nails well and when I was researching installation of
flooring, all the advice I received said I needed at least an extra
1/2" of ply. I installed my pre-fin flooring at a 45 degree angle to
the joists. Other than adding some extra subfloor, the installation of
prefinished floor is a breeze.

-Rob

MacBain wrote in message . ..
As a long time lurker and occasional contributor to this group I
realize this may not be the correct to post this message but I'm going
to do it anyway. :-)

I'm a competent amateur woodworker,
http://bmacgillivray.ott.istop.com/w.../projects.html and
have done my fair share of home renovation projects but I've never
installed hardwood flooring before. I've read up on it on a few web
sites and perused the flooring book from the Borg and in all cases
they suggest runing the flooring strips at right angles to the joists.
Esthetically, this will not work in our house.

The current subfloor is 3/4" osb and is in ok condition. I read
someplace that to install the flooring parallel to the joists an extra
1/2" plywood layer would be a good idea. Is this necessary or is is
overkill?

TIA
BMG


david May 12th 04 06:43 PM

Prefinished hardwood flooring installation question
 
Look at http://www.nofma.org/installation.htm (NOFMA: The Wood Flooring
Manufacturers Association)

they state that 3/4 OSB is an acceptable subfloor. They dont
specifically say it's ok to go parallel to the joists with that, though.
I think it would be wise to add the plywood if going parallel to the
joists...

david

MacBain wrote:

As a long time lurker and occasional contributor to this group I
realize this may not be the correct to post this message but I'm going
to do it anyway. :-)

I'm a competent amateur woodworker,
http://bmacgillivray.ott.istop.com/w.../projects.html and
have done my fair share of home renovation projects but I've never
installed hardwood flooring before. I've read up on it on a few web
sites and perused the flooring book from the Borg and in all cases
they suggest runing the flooring strips at right angles to the joists.
Esthetically, this will not work in our house.

The current subfloor is 3/4" osb and is in ok condition. I read
someplace that to install the flooring parallel to the joists an extra
1/2" plywood layer would be a good idea. Is this necessary or is is
overkill?

TIA
BMG



K. B. May 13th 04 04:25 AM

Prefinished hardwood flooring installation question
 
The reason to run perpendicular is for the joist to bear the load. Is it
over kill? Wait until you unload 300 sq.feet of 3/4" flooring and get a
real feel for what is going to weight! We actually stacked some of our wood
flooring boxes PARALLEL to the joists (like your proposed installation) and
the plywood underfloor bowed and flexed! We re stacked perpendicular.
Overkill- no. Architecturally correct- yes.

--
KB

"Eric Johnson" wrote in message
...
Rule of thumb I was taught is it takes an 1 1/2 inch subfloor to keep
ceramic tile from turning into dust, that said I think that even if you

add
the subfloor to build up to 1 1/4 I'm betting the floor would have some
waves in it after some time. Maybe if you had access to the joists
underneath you could add some solid blocking?

EJ