Default Shop Vac vs. DC - Hard Evidence - maybe a ramble

Okay, I can end the debate. I had originally plumbed my gara...shop to
a Craftsman 6HP (yeah, right) shop vacuum to support one machine at
time dust collection for router table, RAS, and contractor saw with
dust panel underneath and makeshift closure of the back. It actually
worked pretty well, but it was not catching the fine dust as well as I
wanted.

So, I just upgraded to the the 2HP (at 20 amps? That math doesn't work)
Harbor Freight unit. I had anticipated this move when I put in the
plumbing and used 4" PVC for everything, including a convenience drop
in the center of the garage ceiling to vacuum the floor and cars etc.
All I had to do to install the new DC was to add a 4" port and hood it
up with flex hose. Since I like having the availability of the vac, I
left it plumbed in, but added a blast gate to both it and the DC so I
can select which one to use.

It's a perfect set up for a side by side comparison of vac vs. DC.

The results:

- As mentioned above, the shop vac is okay as a DC for one machine, but
not good enough for my wife, whose car was getting dussted regularly.
- The DC works MUCH BETTER on all machines. On the contractor saw, I
could not see anything at all escaping while ripping some Spanish
Cedar.
- The 2HP CD makes a lousy vacuum cleaner.

Okay, everyone already knew this, but it was interesting to see it
first hand.

Tom

  #2   Report Post  
CNT
 
Posts: n/a
Default

I am still using my shop-vac for all my "DC". But I want to add that the
JET air-filtration does a beautiful job of cleaning the dusts flying
around! I have the JET model (1000B).

Chuck
  #3   Report Post  
Andy
 
Posts: n/a
Default

I, too, am still using my Ridgid shop-vac for DC, and a fan pointed out
the window as an additional vent. I do have an ultra-fine filter for
the shop vac, which helps. The shopvac works well when attached
directly to my router table/bandsaw/RO sander, and I haven't had any
problems with dust flying around or building up anywhere else in the
basem... shop, as long as I have the shopvac attached directly to the
tool.
Interesting to read about them compared side-by-side, though!
Andy

  #4   Report Post  
toller
 
Posts: n/a
Default


- The DC works MUCH BETTER on all machines. On the contractor saw, I
could not see anything at all escaping while ripping some Spanish
Cedar.


How do you have it attached to your contractor's saw? I tried doing mine,
but there are so many holes that it was pretty pointless.

What is spanish cedar?


  #5   Report Post  
Patriarch
 
Posts: n/a
Default

"Andy" wrote in news:1120678938.260669.213570
@z14g2000cwz.googlegroups.com:

I, too, am still using my Ridgid shop-vac for DC, and a fan pointed out
the window as an additional vent. I do have an ultra-fine filter for
the shop vac, which helps. The shopvac works well when attached
directly to my router table/bandsaw/RO sander, and I haven't had any
problems with dust flying around or building up anywhere else in the
basem... shop, as long as I have the shopvac attached directly to the
tool.
Interesting to read about them compared side-by-side, though!
Andy


The Ridgid shop-vac I have screams like an F18 in full afterburner mode.
It gets used when it is the only available option, and then only with
hearing protection.

I'd rather use a broom.

Patriarch


  #6   Report Post  
Larry Jaques
 
Posts: n/a
Default

On Wed, 06 Jul 2005 21:12:05 GMT, the opaque "toller"
clearly wrote:


- The DC works MUCH BETTER on all machines. On the contractor saw, I
could not see anything at all escaping while ripping some Spanish
Cedar.


How do you have it attached to your contractor's saw? I tried doing mine,
but there are so many holes that it was pretty pointless.

What is spanish cedar?


Ay chihuahua! Eez $9.25 a board foot, señor. (16/4)
http://www.buckwoodcraft.com/marine_...20Price%20List

http://www.westwindhardwood.com/hard_s.html $7.92 b/f PICTURE


-
Better Living Through Denial
------------
http://diversify.com Dynamic Websites, PHP Apps, MySQL databases
  #7   Report Post  
 
Posts: n/a
Default

toller wrote:
How do you have it attached to your contractor's saw? I tried doing mine,
but there are so many holes that it was pretty pointless.

What is spanish cedar?


I just rigged some cardboard to close the back of the saw (have to
remove it to move the blade off 90 degrees) and I have one of the "dust
hoods" that closes up the bottom and provides a 4" dust port. With the
vac I had that reduced down to 2.5" for the standard hose. It worked
pretty well, but with the DC I don't get any noticeable dust off the
blade coming out the top.

Spanish Cedar is pretty soft, but officially considered a hardwood
according to the guys at the lumber yard. Why I'm using it is a long
story, but it's commonly used raw for outdoor shutters because it has
great moisture tolerance, i.e. it gets wet but dries very thouroughly
wihtout disfigurement. It's also commonly used for humidors.

The shop smells wonderful!

  #8   Report Post  
Bob G.
 
Posts: n/a
Default



The Ridgid shop-vac I have screams like an F18 in full afterburner mode.
It gets used when it is the only available option, and then only with
hearing protection.

I'd rather use a broom.

Patriarch

==================
Have to agree with the noise....But that can be fixed....!

My simply enclosing the shop vac in a box ...leaving a vent around the
bottom for air flow... and cutting a hole in the top or side for the
hose to enter... and adding a remote control X-10 device to turn it on
and off...

Been using that method for years and never had any problems at
all..noise reduction is very low...

I use the small 2 inch or so cheap clear plastic tubes and orange
little blast gates sold as a Shop Vac system by The borg...

I HOWEVER DO NOT use it as a DC system....more of a central
vaccum system for my shop... (have a dozen or so blast gates that I
can plug into around the shop so that 100 percent of my shop can be
reached by a single 8 foot shop vac hose ...

THAT SAID:

I have 2 DC's in my shop ... a 2 Hp Griz which handles all my machines
(1 at a time via Blast gates) and a 1 Hp little Penn State unit that
handles both my Horizontal & regular Router tables, my spindle sander
and my planner....also via regular 4 " PVC and blastgates...
In addition I have a Delta air filter mounted up high on one end of
the shop and a home made air filter sitting under my workbench on the
other side of the shop....

By just using the shop vac as a DC ..without the 2 in pipe
etc..hooking it up to each machine it honestly will pick up most of
the chips...but hardly any of the small airborn dust .... Lets say it
is a good CHIP VACCUM but a Pi$$ poor dust collector...

The real dust collectors on the oher hand will remove almost all the
air born small dust particles but have a hell of a time picking up the
larger chips... gets most of them but by no means all...

From My observations and simple tests...Dust Collectrors do a great
job collecting dust but make darn poor vaccums...Shop Vac on the other
had are extremely poor Dust collectors but suck up the larger chips
better... Nothing new in this observation since DC move a heck of a
lot of air with low velocity wheras a Shop vac moves much less air but
moves it at a higher velocity...

With all these (2 air filters, 2 Dust Collectors and a central vacc
system) in my shop you may think I really am a health nut ...but in
truth I installed them ONLY to have a cleaner shop in which to
relax...I honestly (at 61 years old & a smoker) was not in any way
trying to protect my lungs etc...I just like my shop to be clean ...

Bob Griffiths
  #10   Report Post  
 
Posts: n/a
Default

To summarize, you seem to have done an experiment to confirm that a
dust collector is better at dust collection and a vacuum is better at
vacuuming.


Well...yeah. But since I did the plumbing for other reasons, the
experiement only took about two minutes and I got to play with my toys
and make sawdust in the process. Woohoo!!!!



  #11   Report Post  
Clint
 
Posts: n/a
Default

So are you saying that you had your shop vac hooked up to the 4" PVC? Or
was your shop vac hooked up directly to the machines? If it was hooked up
to the 4" PVC, I think I can understand why that would suck (in a bad way).

Clint

wrote in message
oups.com...
Okay, I can end the debate. I had originally plumbed my gara...shop to
a Craftsman 6HP (yeah, right) shop vacuum to support one machine at
time dust collection for router table, RAS, and contractor saw with
dust panel underneath and makeshift closure of the back. It actually
worked pretty well, but it was not catching the fine dust as well as I
wanted.

So, I just upgraded to the the 2HP (at 20 amps? That math doesn't work)
Harbor Freight unit. I had anticipated this move when I put in the
plumbing and used 4" PVC for everything, including a convenience drop
in the center of the garage ceiling to vacuum the floor and cars etc.
All I had to do to install the new DC was to add a 4" port and hood it
up with flex hose. Since I like having the availability of the vac, I
left it plumbed in, but added a blast gate to both it and the DC so I
can select which one to use.

It's a perfect set up for a side by side comparison of vac vs. DC.

The results:

- As mentioned above, the shop vac is okay as a DC for one machine, but
not good enough for my wife, whose car was getting dussted regularly.
- The DC works MUCH BETTER on all machines. On the contractor saw, I
could not see anything at all escaping while ripping some Spanish
Cedar.
- The 2HP CD makes a lousy vacuum cleaner.

Okay, everyone already knew this, but it was interesting to see it
first hand.

Tom



  #13   Report Post  
 
Posts: n/a
Default

So are you saying that you had your shop vac hooked up to the 4" PVC? Or
was your shop vac hooked up directly to the machines? If it was hooked up
to the 4" PVC, I think I can understand why that would suck (in a bad way).


How it was:

I had a network of 4" PVC which was reduced back to 2.5 " where the vac
was attached, and at each of the machines. So even though the RAS and
table saw have 4" ports, they were connected to the network by the
smaller hose. I had blast gates at all of the machines.

How it is now:

The vac is still hooked up through it's own 2.5" hose (very short run,
hides in a cabinet) and a blast gate so it can be isolated from the
system when I run the DC. The machine hookups are now 4" DC hose with
4" blast gates, i.e. 4" all the way to the DC. The DC also has a blast
gate so I can switch in the vac for "central vac" use.

The "vac" port in the middle of the shop is still reduced to 2.5" so I
can use standard hose and attachments (it hangs from the ceiling). At
that point, there's about 20' of PVC run back to the vac. I left
another vac port near the drill press for manual cleanup after drilling
plus it can easily reach the work bench for general cleanup.

I'm not sure why you feel that the 4" PVC run would hurt the
performance of the vac?

Tom

  #14   Report Post  
Clint
 
Posts: n/a
Default

AFAIK, moving the dust depends on maintaining a air flow velocity (feet per
minute). If the airflow falls too low, the dust can settle, all you end up
with at the dust collector/shop vac end is a slow stream of clean air.

When you expand the size of the hose from the 2.5" diameter to 4" diameter
hose, the velocity of the 4" section will about 40% of the velocity of the
2.5" section. Unless you've got enough airflow from the shop vac, it would
be likely that it won't have the umph to get the dust all the way from the
tool to the vac.

NOTE: This is all theoretical, as I'm using a shop vac for dust collection,
and haven't played with larger hoses because of this. I thought about
running some PVC or metal runs, but I don't want to do it twice (once for
shop vac, once for the dust collector I know I need).

Clint

wrote in message
oups.com...
So are you saying that you had your shop vac hooked up to the 4" PVC? Or
was your shop vac hooked up directly to the machines? If it was hooked

up
to the 4" PVC, I think I can understand why that would suck (in a bad

way).

How it was:

I had a network of 4" PVC which was reduced back to 2.5 " where the vac
was attached, and at each of the machines. So even though the RAS and
table saw have 4" ports, they were connected to the network by the
smaller hose. I had blast gates at all of the machines.

How it is now:

The vac is still hooked up through it's own 2.5" hose (very short run,
hides in a cabinet) and a blast gate so it can be isolated from the
system when I run the DC. The machine hookups are now 4" DC hose with
4" blast gates, i.e. 4" all the way to the DC. The DC also has a blast
gate so I can switch in the vac for "central vac" use.

The "vac" port in the middle of the shop is still reduced to 2.5" so I
can use standard hose and attachments (it hangs from the ceiling). At
that point, there's about 20' of PVC run back to the vac. I left
another vac port near the drill press for manual cleanup after drilling
plus it can easily reach the work bench for general cleanup.

I'm not sure why you feel that the 4" PVC run would hurt the
performance of the vac?

Tom



  #15   Report Post  
 
Posts: n/a
Default

In my situation, since the hose to the machine was down to 2.5" again,
the air velocity at the tool was essentially unnaffected by the 4" pipe
(air in = air out). That's why the vac sucks just about as well through
the big pipe with normal 2.5" implements attached. It's actually a lot
better than a long run of smaller pipe because there is less friction
loss.

You're right about the slower velocity in the larger pipe, though, and
it's possible that I was getting some accumulation of sawdust in the 4"
sections. That's why I used a 5 gal. separator (2.5") right at the
table saw before entering the PVC. The RAS port is actually very close
to the vac tie-in which minimized the problem. It's a big vac, which
still moves enough air such that the open hose would suck light sawdust
in from at least 3" away. It's reasonable to assume that it could keep
the same light sawdust moving through an enclosed 4" pipe. Larger chips
would be a different matter. It's academic now because I have the DC.

If I was in a dedicated shop, I probably would have stayed with the vac
because I was pretty happy with the results, but I really hated the
fine dust all over the cars and my mechanics tools. (Like many others
on the rec, I'm a car person too). Depending on how the new setup
works, I still may end up getting an air filtration unit.

If I could just get these dang shutters finished I could bet back to
car work...



  #16   Report Post  
 
Posts: n/a
Default

Very effective exhaust silencers have been available for Shop-vacs for
years now. (Unfortunately not available for my Hitachi TS.) :') So I
still use "ear-muffs" at times, but torture neighbors, and cat, much
less.

HTH,
J

  #17   Report Post  
 
Posts: n/a
Default

Details, details: GoreTex filter in vac is _much_ better (IMHO) at
trapping fines than DC- those sub-micron fines are the stuff that gets
down into your lungs. (USCG has investigated this for years re
shipboard engineering repair safety.)

Crunchy-dust here and there? Scoop it up.

Nasty fines down in your lungs? See what develops.

HTH,
J

  #18   Report Post  
 
Posts: n/a
Default

Details, details: GoreTex filter in vac is _much_ better (IMHO) at
trapping fines than DC- those sub-micron fines are the stuff that gets
down into your lungs. (USCG has investigated this for years re
shipboard engineering repair safety.)


Crunchy-dust here and there? Scoop it up.


Nasty fines down in your lungs? See what develops.


Yeah, but in order to get trapped by the filter or bag, the dust must
first get pulled into the system. The vac was leaving the fine dust in
the air around the machine (and me). BTW, I just ordered a one micron
bag. Spec claims that it will filter sub micron stuff once a cake
builds up on the felt. We'll see.

  #19   Report Post  
Unquestionably Confused
 
Posts: n/a
Default

on 7/7/2005 2:00 PM said the following:
In my situation, since the hose to the machine was down to 2.5" again,
the air velocity at the tool was essentially unnaffected by the 4" pipe
(air in = air out). That's why the vac sucks just about as well through
the big pipe with normal 2.5" implements attached. It's actually a lot
better than a long run of smaller pipe because there is less friction
loss.


In a perfect world, perhaps... Think about it for a moment though. We
are talking about a VACUUM. The more air that must be removed from a
given vessel until the ultimate vacuum pressure (or lack thereofg) is
created, the less effective the vacuum device is. Granted, the
difference may be small if we are considering a perfectly sealed 4" pipe
which terminates at either end into a 2½" fitting. You still must
consider the friction caused by the bends, etc. which will change the
equation depending upon whether or the number of bends in the tube and
the diameter. Ask a plumber how this affects water pressure.

Take it a step up to the point of ridiculous - just to demonstrate. How
long do you think it would take to draw away all those chips coming from
your planer if you had a 4" hose connected to the planer, which hose was
then connected to an airtight box 10' square and 8' high, to which was
then connected the intake on a 1100CFM DC? All that air can compress and
expand in the box and that's going to be a factor in your efficiency.
  #20   Report Post  
 
Posts: n/a
Default



Unquestionably Confused wrote:
on 7/7/2005 2:00 PM said the following:
In my situation, since the hose to the machine was down to 2.5" again,
the air velocity at the tool was essentially unnaffected by the 4" pipe
(air in =3D air out). That's why the vac sucks just about as well throu=

gh
the big pipe with normal 2.5" implements attached. It's actually a lot
better than a long run of smaller pipe because there is less friction
loss.


In a perfect world, perhaps... Think about it for a moment though. We
are talking about a VACUUM. The more air that must be removed from a
given vessel until the ultimate vacuum pressure (or lack thereofg) is
created, the less effective the vacuum device is. Granted, the
difference may be small if we are considering a perfectly sealed 4" pipe
which terminates at either end into a 2=BD" fitting. You still must
consider the friction caused by the bends, etc. which will change the
equation depending upon whether or the number of bends in the tube and
the diameter. Ask a plumber how this affects water pressure.

Take it a step up to the point of ridiculous - just to demonstrate. How
long do you think it would take to draw away all those chips coming from
your planer if you had a 4" hose connected to the planer, which hose was
then connected to an airtight box 10' square and 8' high, to which was
then connected the intake on a 1100CFM DC? All that air can compress and
expand in the box and that's going to be a factor in your efficiency.


Or a 55 gallon drum that's used as a separator. I think the effect
you're describing only really applies at startup. Once the steady state
is achieved in the entire system, it should flow "about" the same and
the efficiency should be about the same (ignoring the issues of
turbulence for the sake of this discussion). Otherwise, I think the big
separators would cause all kinds of problems.

My "network" consists of about 35' of 4" pipe which amounts to a pretty
large "chamber" that the vac has to suck down to negative pressure
before reaching that steady state. I can say for sure that the delay
and any degradation in performance are negligible.

Back on to turbulence, this is greatly reduced by using bigger pipe.

I guess we're beating this to death, but it's an interesting
discussion.=20

Tom

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Was Shop heat---update Andrew V Metalworking 33 March 5th 06 03:32 PM
FAQ: HAND TOOLS (Repost) Groggy Woodworking 0 January 16th 05 10:56 AM
Flourescent lights in the shop Koz Metalworking 21 December 22nd 03 09:31 PM
CLOSE CALL - SMOKE ALARM IN THE SHOP? T. Woodworking 47 December 6th 03 04:35 AM
Shop Power keith bowers Metalworking 24 August 1st 03 06:18 AM


All times are GMT +1. The time now is 04:04 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"