Colin Docherty
 
Posts: n/a
Default Fitting whirlpool baths - Is it much more difficult?

Hi Folks,

I've fitted two baths before, but I'd like to get one of these whirlpool
baths now.

Is it a big deal to fit one? Whats involved (you can't see underneath most
of them when in the shops)? And extra things I need to buy?

And regarding electrics, my house has a global RCD, Does this mean I don't
need an RCD for the whirlpool connection? And can I take the power for the
whirlpool bath as a spur from a ring socket?

Thanks Again,
Colin.
  #2   Report Post  
Gordon Henderson
 
Posts: n/a
Default

In article ,
Colin Docherty wrote:
Hi Folks,

I've fitted two baths before, but I'd like to get one of these whirlpool
baths now.

Is it a big deal to fit one? Whats involved (you can't see underneath most
of them when in the shops)? And extra things I need to buy?


It shouldn't be a big deal. I fitted one recently - however it's the
first bath I've ever fitted, so no idea about the differences!

It sits on 4 feet which are adjustable, but I'd also secured it into
a wooden frame under the bath.

And regarding electrics, my house has a global RCD, Does this mean I don't
need an RCD for the whirlpool connection? And can I take the power for the
whirlpool bath as a spur from a ring socket?


I had a spur of the upstairs mains going into a wall mounted fan heater
in the bathroom - I took that out, but kept the cable and diverted it
to a faceplate on the wall next to the bath - I then replaced the fused
switchbox next to a double socket outside the bathroom (where the spur
originated) by a fused RCD unit.

It's a fantastic bath btw. It'll pay for itself in terms of bubble-bath
required in about ....

Seriously, start with ONE CAPFULL of bubble bath and work up or down
from there.. Don't just pour 1/4 a bottle under the taps as we used to do...

Gordon
  #3   Report Post  
Pet @ www.gymratz.co.uk
 
Posts: n/a
Default

Colin Docherty wrote:

I've fitted two baths before, but I'd like to get one of these whirlpool
baths now.


We have one.

Wouldn't bother replacing it if it broke.

Sure the novelty lasted for.... a few baths, but the droning of pumps,
rapid cooling of water due to air being pumped through, and not to
mention the vast amounts of moisture it released into the air.

Ours is anything _but_ a relaxing bath.

Of course, you don't _have_ to use the bubbles and jets, and it looks
dead posh to the comoners that haven't seen one before!

:¬)

--
http://gymratz.co.uk - Best Gym Equipment & Bodybuilding Supplements UK.
http://trade-price-supplements.co.uk - TRADE PRICED SUPPLEMENTS for ALL!
http://fitness-equipment-uk.com - UK's No.1 Fitness Equipment Suppliers.
http://gymratz.co.uk/hot-seat.htm - Live web-cam! (sometimes)
  #4   Report Post  
Chris J Dixon
 
Posts: n/a
Default

Colin Docherty wrote:

I've fitted two baths before, but I'd like to get one of these whirlpool
baths now.

Is it a big deal to fit one? Whats involved (you can't see underneath most
of them when in the shops)? And extra things I need to buy?

And regarding electrics, my house has a global RCD, Does this mean I don't
need an RCD for the whirlpool connection? And can I take the power for the
whirlpool bath as a spur from a ring socket?

Should be OK, but don't forget that this now comes under part P
(Google if you are not up to speed)

Chris
--
Chris J Dixon Nottingham UK


Have dancing shoes, will ceilidh.
  #5   Report Post  
Stefek Zaba
 
Posts: n/a
Default

Chris J Dixon wrote:


And regarding electrics, my house has a global RCD, Does this mean I don't
need an RCD for the whirlpool connection? And can I take the power for the
whirlpool bath as a spur from a ring socket?


Should be OK, but don't forget that this now comes under part P
(Google if you are not up to speed)

Depends on the rating of the whole-house RCD. If it's 30mA sensitivity,
it's OK (though not best practice to have all the lights go out when
some other circuit causes the RCD to trip). But if it's a 100mA
sensitivity trip - as needed for a TT installation, typical with a rural
overhead supply - it's not nearly sensitive enough to provide the
required protection against shock, and you'd need a 30mA RCD for the
circuit the whirlpool feeds from.
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Name of fitting? Doug Miller Home Repair 12 December 22nd 04 11:59 PM
flush fitting light in bathroom Stephen Spinks UK diy 0 November 1st 04 11:49 PM
Opinions on Maytag and Whirlpool dishwashers? Ohaya Home Repair 7 April 18th 04 01:46 PM
Whirlpool Gas Water Heater Woes mrthejab Home Repair 1 April 14th 04 09:17 AM
Old hot water tank fitting mike ring UK diy 0 August 18th 03 08:12 PM


All times are GMT +1. The time now is 10:53 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"