hello
Any ideas anyone? The central heating from our boiler stops for no
good reason. It can be on for 5 mins, 10 mins or an hour but then will
suddenly turns itself off. It is also erratic it terms of switching
between central heating and hot water. It has difficulty igniting when
shifting between one function and another. The boiler heats water like
a dream and when it is working we have no problems but we never know
when it will behave badly. British Gas have changed the expansion
chamber, the sensor, the room thermostat and various electronics
boards. Each engineer thinks he's solved it but they haven't. All ideas
grstefully received.

  #2   Report Post  
Christian McArdle
 
Posts: n/a
Default

British Gas have changed the expansion chamber, the sensor, the
room thermostat and various electronics boards. Each engineer
thinks he's solved it but they haven't.


But at no point have they replaced the diverter valve?

Seems odd, as this behaviour screams diverter at me. I don't know the
boiler, though. Perhaps it doesn't have a conventional diverter.

Christian.


  #4   Report Post  
 
Posts: n/a
Default

They may have changed the diverter valve but not told me. I will ask
the next engineer. Many thanks for the suggestion.

  #5   Report Post  
 
Posts: n/a
Default

Many thanks. Will do so.



  #6   Report Post  
Tony Bryer
 
Posts: n/a
Default

In article .com, wrote:
You could do worse than posting to
http://cgi.www.a1-gas.co.uk/cgi-bin/...cript=question
(or http://tinyurl.com/6df2u) - there's a wealth of knowledge
there and at least one Worcester engineer.


Has it never occurred to the owner of said site that having one 2.4MB
home page makes it hopeless for dial-up users (most of use are ADSL
of course), hard to find stuff and uses up his bandwith allocation
real fast?

--
Tony Bryer SDA UK 'Software to build on' http://www.sda.co.uk
Free SEDBUK boiler database browser http://www.sda.co.uk/qsedbuk.htm


  #7   Report Post  
 
Posts: n/a
Default

Tony Bryer wrote:
In article .com,

wrote:
You could do worse than posting to

http://cgi.www.a1-gas.co.uk/cgi-bin/...cript=question
(or http://tinyurl.com/6df2u) - there's a wealth of knowledge
there and at least one Worcester engineer.


Has it never occurred to the owner of said site that having one 2.4MB
home page makes it hopeless for dial-up users (most of use are ADSL
of course), hard to find stuff and uses up his bandwith allocation
real fast?


I couldn't agree more... I have a suspicion that the owner doesn't even
know how popular it is. Indeed I have yet to see a post from anyone
actually *from* the 'company'.

Furthermore, by the looks of things they seem to be shooting themselves
in the foot by promoting such an envonement whereby potential customers
are fixing their boilers themselves on a daily basis given the advice
from the board!

Mathew

  #8   Report Post  
raden
 
Posts: n/a
Default

In message , Christian
McArdle writes
British Gas have changed the expansion chamber, the sensor, the
room thermostat and various electronics boards. Each engineer
thinks he's solved it but they haven't.


But at no point have they replaced the diverter valve?

Seems odd, as this behaviour screams diverter at me. I don't know the
boiler, though. Perhaps it doesn't have a conventional diverter.


If the boards hadn't been changed, I would have suspected the relay on
the Zagas 126 (sequence) board which drives the fan - a common failure

Yes, it could also be e.g. a knacked microswitch in the diverter valve.
As to whether it's a conventional 3 port valve or not, I can't remember
offhand

--
geoff
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
new combi experience report Fred UK diy 12 December 5th 04 09:11 PM
Worcester 24i Combi boiler keeps cutting out Gareth UK diy 2 October 24th 04 09:41 PM
new Worcester Bosch install / boiler problem Colin Wilson UK diy 2 April 2nd 04 08:56 PM
Worcester Bosch 28CDi RSF Combi problem [email protected] UK diy 7 February 26th 04 07:30 PM
Worcester combi boiler not always firing Oliver Payne UK diy 4 August 31st 03 06:23 PM


All times are GMT +1. The time now is 06:36 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"