Home |
Search |
Today's Posts |
![]() |
|
UK diy (uk.d-i-y) For the discussion of all topics related to diy (do-it-yourself) in the UK. All levels of experience and proficency are welcome to join in to ask questions or offer solutions. |
|
LinkBack | Thread Tools | Display Modes |
#12
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
On Tuesday, May 11, 2021 at 5:28:58 PM UTC+1, Tim+ wrote:
This is possibly gonna sound a bit wimpish but Ive never pulled a 100 amp main fuse before but Im beginning to think that it might be worth a shot to try and reboot my smart meter which has lost its ability to communicate with my power company. Literally been waiting months for an engineers visit and thinking that a power cycle *might* sort it. Obviously theres a fair chance that it might not but if I can do it easily and safely it seems worth a shot. Tim -- Please don't feed the trolls When I replaced our consumer unit we had to do it in stages, the first was to get the meter moved out of the way as it partially covered the area in which the CU was going. The engineer from the DNO simply switched everything off MCBs and then main switch. At first he was going to use 16mm2 tails but noticed the cutout had a 100A fuse and used 25mm2 tails. He then simply pulled the main fuse after cutting the seals, the only safety measure he employed was to put a red plastic cover over the live lower spring prongs which seemed to clip in place. Having moved the meter and replaced the tails between cutout and meter he brought out 25mm2 tails from the meter and using a pair of Henly block type connectors joined the new tails from the meter to the 16mm2 tails in the CU. Having seen that the cutout was sound and not likely to disintegrate when I replaced the CU I therefore had no qualms about pulling the main fuse. First thing I did was fit a stand alone main switch so that I never had to pull the fuse again. When we had the smart meter fitted the engineer did not seem bothered that there was no seal on the main fuse but did fit one when he finished and also fitted one on the lower terminal cover on the separate main switch I had fitted. Richard |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
diff between a 250V 10A fuse and a 32V 10A glass fuse? | Home Repair | |||
plug ring circuit keeps flicking the fuse switch on fuse board | UK diy | |||
5A fuse replacement in fuse box - does not quite fit... | UK diy | |||
switch-fuse and service-fuse discrimination | UK diy | |||
Pulling the electric co's fuse... | UK diy |