Default Using external wall cavity to carry 2.5mm T&E cable

Hi
I think the subject explains most of what I'm looking to do.
I need to add a double socket and the best place for the cable is the
wall cavity. The socket is on an exernal wall on the ground floor which
has floorboards. The wall cavity is insulated but not with polystyrene
balls.
Apart from the various rules saying it's an undesirable situation, are
there any tips to accomplish said task? Was going to drill at a downward
angle into the cavity from where the socket will be, and hope to pick up
the cable into a hole into the cavity under floorboard level. I was
intending to have a bigger diameter hole under the floor and use a hook
to pull the cable through, assuming it ever feeds into the right
location! Could protect holes to avoid damaging cable when pulling through.
Any other tips? Ta.
  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,037
Default Using external wall cavity to carry 2.5mm T&E cable

On 11/11/2019 13:58, Grumps wrote:
Hi
I think the subject explains most of what I'm looking to do.
I need to add a double socket and the best place for the cable is the
wall cavity. The socket is on an exernal wall on the ground floor which
has floorboards. The wall cavity is insulated but not with polystyrene
balls.
Apart from the various rules saying it's an undesirable situation, are
there any tips to accomplish said task? Was going to drill at a downward
angle into the cavity from where the socket will be, and hope to pick up
the cable into a hole into the cavity under floorboard level. I was
intending to have a bigger diameter hole under the floor and use a hook
to pull the cable through, assuming it ever feeds into the right
location! Could protect holes to avoid damaging cable when pulling through.
Any other tips? Ta.


You can make it easier to catch the cable by pushing a doubled tape
measure into the hole so that is spreads out against the outer leaf.
  #3   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 12,364
Default Using external wall cavity to carry 2.5mm T&E cable

On Monday, 11 November 2019 13:58:55 UTC, Grumps wrote:
Hi
I think the subject explains most of what I'm looking to do.
I need to add a double socket and the best place for the cable is the
wall cavity. The socket is on an exernal wall on the ground floor which
has floorboards. The wall cavity is insulated but not with polystyrene
balls.
Apart from the various rules saying it's an undesirable situation, are
there any tips to accomplish said task? Was going to drill at a downward
angle into the cavity from where the socket will be, and hope to pick up
the cable into a hole into the cavity under floorboard level. I was
intending to have a bigger diameter hole under the floor and use a hook
to pull the cable through, assuming it ever feeds into the right
location! Could protect holes to avoid damaging cable when pulling through.
Any other tips? Ta.


It can be a pain getting hold of the cable at the lower end.
  #4   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 3,237
Default Using external wall cavity to carry 2.5mm T&E cable

Grumps wrote:

Hi
I think the subject explains most of what I'm looking to do.
I need to add a double socket and the best place for the cable is the
wall cavity. The socket is on an exernal wall on the ground floor which
has floorboards. The wall cavity is insulated but not with polystyrene
balls.
Apart from the various rules saying it's an undesirable situation, are
there any tips to accomplish said task? Was going to drill at a downward
angle into the cavity from where the socket will be, and hope to pick up
the cable into a hole into the cavity under floorboard level. I was
intending to have a bigger diameter hole under the floor and use a hook
to pull the cable through, assuming it ever feeds into the right
location! Could protect holes to avoid damaging cable when pulling through.
Any other tips? Ta.

You may need to use something like fencing partly hardened steel wire to
force it through the edge of an insulation batt if you are unlucky. It
may need derating for being insulated, an electrician will tell us if
it is ok for a 32A ring.

--

Roger Hayter
  #5   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,624
Default Using external wall cavity to carry 2.5mm T&E cable

In my daughter's new build the meter tails run approx. 3m in the cavity from the external meter box to the CU. When the houses were being built the external walls were cavity insulated with foam sheets so I presume a channel was left to feed the cables through.

Richard
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Doubled up 9.5mm PB vs 12.5mm PB Tim Watts[_3_] UK diy 11 July 19th 16 08:27 AM
lights wires 1.5mm or 2.5mm (100 amp maion fuse) george [dicegeorge] UK diy 18 January 2nd 11 03:34 PM
Cavity wall Insulation for narrow cavity [email protected] UK diy 9 April 25th 09 10:42 PM
Cavity wall insulation - cavity too large ???? [email protected] UK diy 8 October 4th 08 01:12 PM
HELP: need diagram of a stereo 2.5mm plug to a 2.5mm socket graph 1 Electronics 1 May 30th 04 10:31 PM


All times are GMT +1. The time now is 07:38 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"