Home |
Search |
Today's Posts |
![]() |
|
UK diy (uk.d-i-y) For the discussion of all topics related to diy (do-it-yourself) in the UK. All levels of experience and proficency are welcome to join in to ask questions or offer solutions. |
|
LinkBack | Thread Tools | Display Modes |
#1
![]()
Posted to uk.d-i-y
|
|||
|
|||
![]()
Hi
I think the subject explains most of what I'm looking to do. I need to add a double socket and the best place for the cable is the wall cavity. The socket is on an exernal wall on the ground floor which has floorboards. The wall cavity is insulated but not with polystyrene balls. Apart from the various rules saying it's an undesirable situation, are there any tips to accomplish said task? Was going to drill at a downward angle into the cavity from where the socket will be, and hope to pick up the cable into a hole into the cavity under floorboard level. I was intending to have a bigger diameter hole under the floor and use a hook to pull the cable through, assuming it ever feeds into the right location! Could protect holes to avoid damaging cable when pulling through. Any other tips? Ta. |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Doubled up 9.5mm PB vs 12.5mm PB | UK diy | |||
lights wires 1.5mm or 2.5mm (100 amp maion fuse) | UK diy | |||
Cavity wall Insulation for narrow cavity | UK diy | |||
Cavity wall insulation - cavity too large ???? | UK diy | |||
HELP: need diagram of a stereo 2.5mm plug to a 2.5mm socket | Electronics |